AT Current Instrument Transformer Instructions for installation, use and maintenance

Similar documents
MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

Medium Voltage Products. KECA 80 C85 Indoor current sensor

Current and Voltage (potential) Instrument transformers Instruction for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors for Cellpack separable connectors

KEVA B Indoor voltage sensor

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

KEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors

MEDIUM-VOLTAGE MEASURING VOLTAGE TRANSFORMERS USER MANUAL

Content. 1. Dimensiong of CT s. 2. Error definitions. 3. General design aspects. 4. Linear cores. Certified acc. to ISO 9001/14001, SN EN 45001

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

Subject to changes 11/2003 Page 1/7

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Section 2 Outdoor Voltage Transformers

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

Outdoor Instrument Transformers. Application Guide

Three-phase monitoring relay CM-PFS

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Reactor and inductor are names used interchangeably for this circuit device.

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

Earthing of Electrical Devices and Safety

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

3. COMBINED TRANSFORMERS Oil-paper insulation

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

Distribution transformers Part 2 Ground mounted transformers not closecoupled

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Your safety first! This is the reason why our manual begins with the following guidelines:

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Liquid level monitoring relay CM-ENS.2x

Instruction Manual MSC710 MSC710-U MSC710-I

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

CUSTOMER SUPPLIED HIGH VOLTAGE METERING UNIT SPECIFICATION FOR 11, 22 & 33 kv

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

Oil-immersed Transformers

page 2 of 86 Report reference No:

Back to the Basics Current Transformer (CT) Testing

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Installation and Operational Instructions for ROBA -switch Type 017._00.2

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

FMG90 Series Electromagnetic Flow Meter

Three-phase monitoring relay CM-PVE

Top spin Nr /

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications

PCT200 SERIES CT/PT TEST SYSTEM USER MANUAL

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

W DATA SHEET Current Transformer 40 x 10, A

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Austin AUSTIN ISOLATION TRANSFORMER (DUAL WINDING SERIES) Installation Instructions for

Enhanced Quality with a Touch of Style

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

ULTRA-K Series 600K - he

LED Driver Constant voltage

Accessories. Accessories

OIL-IMMERSED ARC-SUPPRESSION COILS

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Capacitor Switching Contactors

Three-phase monitoring relay

Three-phase monitoring relay CM-PBE

vacon nx installation manual ac drives fr7 ip54 kit

Liquid level monitors and controls

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Phase-sequence Phase-loss Relay

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

Power supply CP-D 12/2.1

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Safety switches with slotted hole lever

Australian Standard. Instrument transformers. Part 1: Current transformers (IEC Ed.1.2 (2003) MOD) AS AS

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Transcription:

Products for High Voltage Application AT Current Instrument Transformer Instructions for installation, use and maintenance 1. Service conditions 2 2. Technical details 2 3. Instruction for installation 3 General information 3 Safety instructions 3 Mounting 3 Connection of transformer primary side 3 Connetion of the transformer secondary side 3 4. Instructions for use 3 Routine test report 4 5. Maintenance instructions before installation 4 6. Transport & Storage 4 7. Disposal 4 8. Handling 4 9. Normative references 4 10. Dimensions 5 11. Lifetime 5 12. Service 5 Appendix 1 6 Examples of outlets 6 Appendix 2 7 Dimensional drawings AT35 and AT41 7 Dimensional drawings AT38 7

Instruction for installation, use and maintenance for current instrument transformers These installation, use and maintenance instructions apply for current instrument transformers intended for outdoor operation. The instructions refer to current instrument transformers of the following types: AT41 up to 10 000 A; up to 1.2/6/- kv 40 ka(1s) and 100 ka AT35 up to 5 000 A; up to 1.2/6/- kv 100 ka(1s) and 120 ka AT38 up to 5 000 A; up to 1.2/6/- kv 100 ka(1s) and 120 ka 1. Service conditions 2. Technical details The transformers need to be installed in indoor conditions where the ambient air is not significantly polluted by dust, smoke, corrosive gases, vapor or salts. The transformers are designed for standard ambient temperatures between -20 C and +105 C and altitudes below 1000 m above sea level. The transformers can also be operated at higher or lower ambient air temperatures and higher installation altitudes if such are agreed with the manufacturer. Technical parameters and specifications of each of the transformers are shown on a rating plate fixed to the transformer body. It is not allowed to operate the transformer at values exceeding the rating plate data. Dimensional drawing of AT transformer is shown in Appendix 1. Dimensions of the transformer may vary and depend on required parameters and the application they are intended for. This is why the customer is required to specify the highest or lowest dimensions, in line with the dimensional drawing in Appendix 1. CURRENT TRANSFORMER Type: AT41-1055/670 1 IEC 60044-1 2 1,2/6/- kv Ith:30(1s) ka 3 Idyn:75 ka 4 50 Hz 5 1S1-1S2 6 3 000/1A 7 ext.120% 8 3 VA 9 cl.tpy 10 Rb=3 Ohm, Kssc=10, Tp=100 ms C-O-C-O t -t al-tfr-t -t al=100-60-500-100-60 ms Rct=10 Ohm, Ts=1,00 s, Ktd=27,2 2014 11 Serial:1VLTS114000007 12 Fig. 1. Example of rating plate Where: 1) type code of transformer 2) corresponding standard 3) rated short-time thermal current 4) rated dynamic current 5) rated frequency 6) terminal marking for tap of transformer 7) rated transformer ratio 8) extended current 9) rated output (burden) 10) accuracy classes 11) year of manufacture 12) serial number Tab. 1. Label abbreviation definitions 2 AT Current Instrument Transformer Instructions for installation, use and maintenance

3. Instruction for installation General information Instrument transformer is an electrical equipment and the electrical installation of the instrument transformer can be done by skilled personnel, only. The level of experience, age and eligibility criteria for persons working with, on or near electric installations is governed by national legislation. If no such eligibility legislation is available the corresponding requirements can be found in EN 50110-1 standard. Safety instructions 1. Always consider the transformer as a part of electric circuit which it is connected to. Don t touch incoming connectors and terminals, or any other parts of the transformer, except you know for sure these are earthed. 2. Ground always the metallic base of the instrument transformer. 3. Connect always one terminal of each secondary winding of the transformer to the earth. When the secondary of transformer is interconnected, there should be only one grounded point to prevent accidental paralleling with system grounding wire. The AT transformer is mounted in different ways-using rings to fix the transformer directly to the bushing, using flanges, or other ways of fixation. The mounting is not a part of transformer delivery and the customer is fully responsible for installation in the right way. Tightening torques AT35 (M12) AT38 (M16) AT41 (M16) 30 Nm 30 Nm 50 Nm The producer has not any liability for incorrect mounted form or possible consequences of it. Nuts and threaded rots are delivered on customer request. Connection of transformer primary side The AT transformers don t have its own primary conductor. The primary conductor is designed as a bushing with its own insulation, or insulated cable. Connection of the transformer secondary side Secondary outlets are marked by color. Which color is assigned to which wire you can see in table below. Outlets marking test wire (measure side) test wire (earth side) black marked with M black mark with Ground 4. Always short-circuit the secondary of the current transformer, which is not currently in use, to prevent secondary voltages, which may be hazardous to personnel or damaging to the transformer s secondary. The secondary like this must be additionally grounded. Mounting Mounting points are showed on picture below Lifting points screen earth secondary wire xs1 (X1, Y1, Z1, U1, V1, W1) secondary wire xs2 (X2, Y2, Z2, U2, V2, W2) secondary wire xs3 (X3, Y3, Z3, U3, V3, W3) secondary wire xs4 (X4, Y4, Z4, U4, V4, W4) secondary wire xs5 (X5, Y5, Z5, U5, V5, W5) secondary wire xs6 (X6, Y6, Z6, U6, V6, W6) black mark with Ground black and marked with core/terminal no. red and marked with core/terminal no. yellow and marked with core/terminal no. blue and marked with core/terminal no. grey and marked with core/terminal no. brown and marked with core/terminal no. 4. Instructions for use Mounting points Current instrument transformers are used: Fig. 2. AT35/41 mouting points Mounting points to convert large currents in the primary circuit to an appropriate level for secondary circuit equipment (relays and meters); to insulate primary and secondary circuit from each other to protect the secondary equipment from the harmful effects of large current appearing during the operation (short circuits). The use of current transformer for other purpose then described above is forbidden if not agreed with the producer. Fig. 3. AT38 mounting points AT Current Instrument Transformer IInstructions for installation, use and maintenance 3

Routine test report The routine test report of a current instrument transformer includes: a) verification of terminal markings; b) inter-turn overvoltage test; c) determination of errors. There are two rating plates available for the transformer (one glued on the transformer body, the other in the by-pack kit). On customer request the following information can be provided free of charge: 8. Handling All the manipulation has to be performed with great effort to prevent any damage risks. During manipulation with the hanging strips make sure that it was used equipment for minimalizing of forces applied to active parts (transformer coils) - cushioned hanging strips, tying direction according picture. If necessary place between the strips and coil/flanges, suitable foam distances to prevent of dangerous pressure to coil. Always check whether the last insulation layer of the coils is undamaged after manipulation. For flanges as well. theoretical current/voltage error and phase displacement values; theoretical excitation (magnetization) curves. Additional reports for supplementary charge, made available on request: test report on accuracy; excitation (magnetization) curves; additional nameplates (if more than 2 are required); verification tests for measuring cores (classes 0.2; 0.2 S; 0.5; 0.5 S). 5. Maintenance instructions Excessive dust sediments or any other type of contamination is to be removed from the transformer using a soft brush, in a way not to damage the insulation or cables taken out from the transformer. 6. Transport & Storage Permitted temperature for transport and storage ranges from -40 C to +105 C. During transport and storage the transformers have to be protected from direct impact of solar radiation. The transformers are delivered in wooden crates or fixed on transport pallets. Transported transformers must be protected to avoid any damages. Right option of transport must be wisely chosen. 7. Disposal Materials used in instrument transformers are considered as materials without environmental impact and materials are not toxic. Instrument transformers have to be disposed of in accordance with national legislation relevant to domestic waste disposal. Fig. 5. Manipulation with the hanging strips 9. Normative references IEC 61869-2 Current instrument transformers ISO 12100 Machine safety basic concepts, general principles of design EN 50110-1 Operation of electrical installations Current instrument transformers are designed, tested and manufactured in accordance with international or national standards, the customer requirements, based on an agreement between the customer and the manufacturer. The specific standard is always mentioned on the transformer rating plate (AS, BS, GOST, IEEE, etc). As an example the following standards can be mentioned: IEC 60044-1; IEC 60044-6; IEC 61869-2; AS 60044-1; ČSN EN 60044-1; ČSN EN 60044-6; IEEE Std C57.13.6-2005; ANSI C57.13-1978; CSA Std CAN3-C13-M83; BS EN 60044-1 When agreed, transformers made in accordance with other standards can also be supplied, or in accordance with other release version of the above standards. 4 AT Current Instrument Transformer Instructions for installation, use and maintenance

10. Dimensions Dimensions of the current transformers acc. appendix 2. 11. Lifetime The product s lifetime is more than 40 years. 12. Service After end of lifetime, device must be changed for new one. There is no service interventions allowed after life time. AT Current Instrument Transformer IInstructions for installation, use and maintenance 5

Appendix 1. Examples of outlets 6 AT Current Instrument Transformer Instructions for installation, use and maintenance

Appendix 2. Dimensional Drawings AT35 and AT41 AT38 1500 H 22,5 TESTING PRIMARY M16 22,5 A C A B 500 3000 SIGN VALUE A [mm] 310-880 B [mm] ACC. REQUIREMENTS C [mm] 270-840 H [mm] ACC. REQUIREMENTS AT Current Instrument Transformer IInstructions for installation, use and maintenance 7

Contact us ABB s.r.o. EPMV Brno Videnska 117, 619 00 Brno, Czech Republic Tel.: +420 547 152 082 +420 547 152 614 Fax: +420 547 152 626 E-mail: info.ejf@cz.abb.com 1VLM000656 Rev.-, en 2016.05.18 www.abb.com The data and illustrations are not binding. We reserve the right to make changes without notice in the course of technical development of the product. Copyright 2016 ABB. All rights reserved.