Analog Module D1-15P User Manual

Similar documents
Data Acquisition Modules/ Distributed IO Modules

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

Modbus communication module for TCX2: AEX-MOD

HD 48V01T... HD 4977T...

Single Channel Loop Detector

Fanuc Serial (RS232) Communications Information

Ocean Controls KT-5221 Modbus IO Module

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

The first RADIO Communication Module designed for the weighing industry

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Netbiter IO Extender 4RO 6RTD 8DIO DAIO 8AIV 8AIIS

Product Manual QD1010-USB. Description. Contents. Material List. Setup. General Use. USB Cable Use. USB to RS485 Communications Converter

Technical Manual. Standard Communication Protocol TA3840C

PROFIBUS HUB REPEATER

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

MU110-16R(K) Digital output module 16 channel. User guide

Characteristics and functioning

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

User Manual. Data Acquisition Modules/ Distributed IO Modules

USER MANUAL Z-8TC. Via Germania, Z.I. CAMIN PADOVA ITALY. Via Svizzera, Z.I. CAMIN PADOVA ITALY

WIRELESS MODBUS GATEWAY WGW410

B850 Boiler House Energy Monitor

ZCS485 User s Manual. Version ZYPEX, Inc.

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

Contents. Warranty and Disclaimer 2 Introduction 3

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Z170REG. Universal converter module with galvanic insulation between 2 analog outputs

PL420 PROGRAMMABLE LOGIC CONTROLLER

KNC-SRV-FD423 Series Servo Driver

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Table of Contents. HWIO-Gateway User Manual

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

Serial Communications RS232, RS485, RS422

K3P ENG.qxd 23/10/ Pagina 1

VersaPoint I/O Module

MU110-8R(K) Digital output module 8 channel. User guide

SMARTALPHA RF TRANSCEIVER

Liquid Level Sensors. M-Series Magnetostrictive Sensors

F4-08RTD 8-Channel RTD Input

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

The wireless alternative to expensive cabling...

MULTICONT MULTICHANNEL PROCESS CONTROLLER

TLE ANALOG WEIGHT TRANSMITTER 4 20 ma, 0 20 ma, 0 10 V, 0 5 V, V, -5 5 V

General Specifications

SRC-110 Series Zone Controllers with Modbus RTU

Four-channel Digital Electrometer for Quadrant BPM Readout

The I-2532 CAN to Fiber Converter

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

The "FISH" Quad Hand Sensor

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

User Manual Netbiter IO Extender 4RO 6RTD 8DIO DAIO 8AIx 8AIIx

CP485-4 User s Manual

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

The wireless alternative to expensive cabling...

TAS APFC Controller / Load Managers with MOD-BUS Interface

RS-232 to Current Loop Converters

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

MultiNet. Instruction Manual. Digital Energy Multilin. Serial to Ethernet Converter. Manual P/N: A2 Copyright 2009 GE Multilin

CONV232/422 SERIAL DATA CONVERTER

The wireless alternative to expensive cabling...

RSMFX-2R MULTIFUNCTIONAL

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Air flow meter For ventilation and air-conditioning Model A2G-25

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

MULTICONT OUR PROFESSION YOUR LEVEL

MultiNet Serial to Ethernet Converter

269 Troubleshooting Guide 11/4/98 1

Characteristics and functioning

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

INSTALLATION AND OPERATING MANUAL

MV110-8AS. Analog input module 8 channel. User guide

g GE POWER MANAGEMENT

Contents. Warranty and Disclaimer 2 Introduction 3

ZZxD-Nx-xR Series. Wireless Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Universal RS232/CMOS to RS422/RS485 Converter

Lecture #3 RS232 & 485 protocols

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

JNET Communication Module. JNET Communication ENGLISH

Industrial Modbus I/O Modules

RS-422/RS-485 Line Tester Model 485T

IB IL TEMP 2 UTH. Function. INTERBUS Inline Terminal With Two Analog Input Channels for Measuring Temperature. Data Sheet 5722B

UNDERGROUND PASSIVE MAGNETIC DETECTION SYSTEM CMS & HWS CONFIGURATION WITH ADAPTIVE SENSITIVITY TECHNICAL DESCRIPTION

RENATO DESIRĂ’ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

JUMO Wtrans Receiver with Wireless Data Transmission

IF30. User's manual. Description. Table of contents IF30

ENGLISH ENGLISH ENGLISH ENGLISH. Installation and User Manual version 1.03 TLB4 2014/30/UE EN55022:2010 EN :2005 EN :2007

IP 251 Universal Signal Converter SSI parallel RS232 parallel SSI RS232

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

Transcription:

D1-15P Manual

Analog Module D1-15P User Manual Sielco Elettronica Srl Edison Street 209 20019 Settimo Milanese (MI) - Italy http://www.sielcoelettronica.com info @ sielcoelettronica.com Tel 02 48916252 Fax 02 45329627 1 Installation 1.1 Checking the package 1.2 Dimensions 1.3 Method of attachment 1.4 Physical Description of the module 1.5 Supply 2 Operation 1.6 Inputs 1.6.1 Analog inputs for Pt100 probes 1.7 Serial communication 1.7.1 Serial link 1.7.2 Communication Protocol 1.7.3 Identification 1.7.4 Connection cable 1.8 Earth wiring and shielding 1.8.1 Grounding 1.8.2 Connecting Pt100 probes 2.1 Application A List of ports

1 Installation 1. 1 Check the Box D1-15P Before installing, verify that the contents of the package conforms to your requirement.inside the package are: - No. 1 D1-15P - n 1 instruction manual Check that the model number corresponds to the number ordered and the manual edition corresponding to the year of purchase. The models are: 6 inputs Pt100 two-or three-wire with automatic compensation of cable resistance. The inputs for Pt100 probes have the following characteristics: - Temperature range: -199.9 to +500.0 C (standard model) - Accuracy: ± 0.05% full scale - Resolution: 15 bits - Max resistance connection cables: 20 ohm The D1 series modules are covered by a one year warranty except for damages caused by tampering or wrong wiring. For the purchase date The label on the back of the modules. 1. 2 Dimensions The dimensions of the modules D1-15P are shown in figure 1.1.

Figure 1. 1 - Size of D1-15P 1. 3 Method of attachment All products in the D1 series are equipped with a plastic holder for fixing on rail DIN EN normalized by a shielding screen-printed. On the cover there are schematic mounting indications; gray areas are shown in the interface circuits inside the module, in yellow the sensors and actuators used to be connected externally. The cover serigraph provides only a general wiring diagram and can not show all the possible connection cases, it is therefore necessary, before activating the module, carefully read this manual. Do not exert excessive pressure on the cover and remove the module from the rail.also remember to do these operations with power off. 1. 4 Physical module description

Figure 1. 2 - Diagram D1-15P

Description [C1] Connector for connecting serial RS422/485 [C2] +24 Vdcpowerconnector [M1] Terminal inputs Pt100 probes DIPSW Selection dipswitch and device address of the communication protocol Led LA Supply led Led LM Led by self- Led TX Led data transmitted over the serial RX LED Led Received data 422485 Jumper selection for RS422 or RS485 line 3/2 WIRES Jumper for Pt100 3 (with automatic compensation of line resistance) or 2-wire [C1] - Connector for connecting serial RS422/485 RS422 1 RX- 1 NC 2 RX + 2 NC RS485 3 TX- 3 TX-/RX- 4 TX + 4 TX + / RX + [C2] - Connector for power supply 24 VDC ALIM 1 +24 VDC 2 FIELD GND 3 MECH.GND 1. 5 Power Supply The module must be supplied with a DC power supply 24 V DC (18V <Vcc<36V) via the [C2] and absorb a maximum current Icc = 70 ma at 24 Vdc. The negative power supply must be connected to pin 2 of [C2]. After supplying the power, check that the LA led is lit. 1. 6 Inputs 1. 6.1 Analog inputs for Pt100 probes For the D1-15P series modules can be connected sensors Pt100 2 or 3 wires.

CAUTION:Make sure that the sensors used correspond to IEC 751In the choice of the sensor to verify that the wires that depart from the sensor is electrically isolated from the metal of the sensor itself.leakage currents to the housing of the sensor may affect the accuracy of the reading.pt100 sensors can be 2 or 3-wire, for connection see Figure 1.3. Figure 1.3 - Connection 3-wire PT100 The choice of the type of sensor is performed by placing the appropriate jumper on the left (3-wire) or right (2-wire) The total loop resistance of the connecting cable must be less than 20 ohm (measurement taken between terminal arrival and departure of the loop with the Pt100 short-circuited). We recommend the use of a cable, twisted pair (the first wire must be twisted with the second) with shielding and insulation fire retardant. Do not connect the wires Pt100 through individual not belonging to the same cable, the resistance of the wire round (first wire connected to the first terminal of the triad) must be equal to the resistance of the return wire (second wire connected to the second terminal of the triad). 1. 7 Serial communication 1. 7. 1 Serial connection To connect to D1 modules, you must use the serial interface RS422/485 that usually are not standard equipment in personal computers.as an alternative to serial cards internal converters can be used for external serial interface. SIELCO produces C1-25 model, a serial interface converter RS232- RS422/485 with triple optical isolation.to use it you simply connect it by cable to the RS232 serial port of the PC (COM) and connect it to the [C1] D1-15 according to Table 1.1.

C1-25 D1-15P N N RS-422 RS-422 1 GND GND 2 C2 2 RX- TX- 3 C1 3 RX + TX + 4 C1 4 TX- RX- 1 C1 5 TX + RX + 2 C1 6 0 V 7 +24 V C1-25 D1-15P N N RS-485 RS-485 1 GND GND 2 C2 2 nc nc 1 C1 3 nc nc 2 C1 4 TX-/RX- TX-/RX- 3 C1 5 TX + / RX + TX + / RX + 4 C1 6 0 V 7 +24 V Table 1. 1 - Connecting C1-25 - D1-15 (RS 422/485) The modules D1-15P are provided with configurable serial interface RS422/485, normally configured as RS485.To change the configuration, you simply move the jumper 422/485 in the top left corner on the card. 1. 7. 2 Communication Protocol The communication protocol software is realized according to Modbus ASCII or RTU: protocol selection is via the selector of dipswitch n 2 (RTU = ON, OFF = ASCII). The baud rate selection is made by the # 1 selector dip switch (ON = 19200, 9600 = OFF). ASCII protocol Baud rate 9600/19200 Data bits 7 Parity bit even Stop bit 1 RTU protocol features

Baud rate 9600/19200 Data bits 8 Parity bit none Stop bit 1 NOTE Power on, the module waits for about 4 seconds to communicate. 1. 7. 3 Identification The device may be assigned an identification address between 1 and 63, specified, according to the binary notation, using selector from 3 to 8 of dipswitch (Table 1.2). ADDRESS 1 2 3 4 5 6 7 8 BAUD PROT. 2 5 2 4 2 3 2 2 21 2 0 ON 19200 RTU OFF 9600 ASCII NOTES The address 0 isreserved. 1. 7. 4 connection cable Table 1. 2 - configurationusingdipswitch Use a shielded cable with one (RS-485) or two (RS-422) twisted pair in compliance with EIA RS-485, EIA RS-422, using the shield for ground. Cable Type:Belden 9841 (RS-485), 9842 (RS-422) Maximum attenuation of line:6 db Maximum capacity of line:100 nf Maximum length:1200 m Line Impedance:between 100 and 120 ohms 1. 8 Earth wiring and shielding 1. 8. 1 Grounding For correct operation it is advisable to make the following ground: - the mechanical ground (pin # 3 of connector [C2]) goes directly to the ground;

- the negative power supply (pin # 2 of connector [C2]) must be connected to a local earth. It 'important that the masses are brought to the ground in an independent manner and in any case is to avoid the sharing of traits grounding with power devices. 1. 8. 2 Connecting Pt100 probes The temperature reading is entrusted to the detection of signals from Pt100, of low intensity.eddy currents on the shields can induce disturbances that sensor reading. Follow these shielding rules particularly in disturbed environments by power devices (driver for dc motors, power contact, etc.).. - use shielded and twisted cables for connection with Pt100; - always keep the connection cables as short as possible; - it is preferable to carry out a separate channel between Pt100 signals and signal conductors power; - connect all cable metal shields connection with Pt100 upon arrival on the form, leaving disconnected departing on Pt100; - Connect all shields to pin # 3 of connector [C2]. - 1.8.3 Choice of sensor PT-100 The D1-15P has a jumper for configuring the input channels 3-wire PT100 or 2 wires. The configuration applies to all 6 channels. - In the 3-wire configuration, The module autonomously performs two readings 1st - 2nd line and 1st - 3rd wire.then calculates the resistance of the line (in the hypothesis that the resistance of the Wire way: 1st wire is equal to resistance of the return wire: 2nd wire), performs the compensation and returns the value of the temperature in numerical data Modbus to the supervisor. - In the 2-wire configuration, the module reads 1-2 and returns the temperature to the supervisor increased of the share due to line resistance, The compensation must be carried out in software at supervisor or HMI level for each channel, knowing what is the error due to line resistance, ( which is a constant and that will be subtracted from all measurements made).the

advantage of this last solution is that it is possible to employ a sensor PT 100 of lower cost for the same quality and that it simplifies the plant wiring.. 2 OPERATION 2. 1 Application The D1-15P is equipped with 6 input channels for the detection of temperatures The temperatures are measured by Pt100 2 or 3-wire with automatic compensation of the resistance of the connecting cable, the temperature values are recorded in tenths of a degree on a scale from -2000 to +4000, eg., The value 275 indicates a temperature of 27.5 C.The recorded values are made available through the doors numeric reading T1, T2, T3, T4, T5 and T6 The ports of error signal the presence of an alarm in the reading of the input signals and in case of error Pt100 proceed disconnecting the Pt100 and verifying that there is not some short to ground. The door "number of restart" is only for diagnostic use and gives an indication of the presence of electrical noise.

A List of ports A. 1 Numeric gates (Holding Registers) FunctionalDoors Address Description ID Byte Limits R / W 00 Restartnumber Rs 1 0: 255 R / W 01 Pt100 temperature 1 T1 2-2000: +4000 R 02 Temperature Pt100 2 T2 2-2000: +4000 R 03 Temperature Pt100 3 T3 2-2000: +4000 R 04 Temperature Pt100 4 T4 2-2000: +4000 R 05 Pt100 temperature 5 T5 2-2000: +4000 R 06 Pt100 Temperature 6 T6 2-2000: +4000 R 07 Errors Pt100 et 2 00h: 1FFh R

Diagnosticport (port 7, 2 bytes) Errors Pt100 - et (For each bit: 0 = OK / KO = 1) bit 0 low sample bit 1 high sample bit 2 numerical Pt100 resistance 1 bit 3 numerical line Pt100 1 bit 4 numericalstrength Pt100 2 bit 5 numerical line Pt100 2 bit 6 numericalstrength Pt100 3 bit 7 numerical line Pt100 3 8-bit numericalstrength Pt100 4 bit 9 numerical line Pt100 4 10-bit numericalstrength Pt100 # 5 11-bit numerical line Pt100 # 5 12-bit numerical Pt100 resistance 6 13-bit numerical line 6 Pt100 Note: An error in the bit 0 or bit 1 indicates a fault in the device. An error in bits 2... 13 may be due to failures of sensors PT100, or interconnection with sensors. 1