SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENIRONMENT OTHERS NOTE DC OLTAGE RATED CURRENT CURRENT RANGE RATED POWER OLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) OLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OERLOAD OER OLTAGE OER TEMPERATURE ILIARY POWER() REMOTE ON/OFF ALARM SIGNAL OUTPUT OUTPUT OLTAGE TRIM CURRENT SHARING WORKING TEMP. Note.5 WORKING HUMIDITY STORAGE TEMP., HUMIDITY RSP-3000-12 12 0A 0 ~ 0A 20W RIPPLE NOISE (max.) Note.2 150mp-p OLTAGE TOLERANCE Note.3 POWER FACTOR (Typ.) 10.8 ~ 13.2 1.0% 0.5% 0.5% 0ms, ms at full load 10ms at full load 1 ~ 264AC 254 ~ 370DC 47 ~ 63Hz 0.95/230AC at full load 86% A/1AC A/230AC <2.0mA / 2AC 16A/230AC ~ 110% rated output power Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover 13.8 ~ 16.8 28.8 ~ 33.6 Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 12@0.1A(Only for Remote ON/OFF control) 2.4 ~ 13.2 4.8 ~ 28 - ~ +70 (Refer to output load derating curve) ~90% RH non-condensing - ~ +85, 10 ~ 95% RH RSP-3000-24 24 125A 0 ~ 125A 3000W 150mp-p 22 ~ 28 TEMP. COEFFICIENT 0.05%/ (0 ~ 50 ) IBRATION 10 ~ 500Hz, 2G 10min./1cycle, min. each along X, Y, Z axes SAFETY STANDARDS UL950-1, TU EN950-1 approved WITHSTAND OLTAGE I/P-O/P:3KAC I/P-FG:1.5KAC O/P-FG:0.5KAC SAFETY ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:M Ohms / 500DC / 25 / 70% RH EMC EMI CONDUCTION RADIATION Compliance to EN55022 (CISPR22) (Note 4) HARMONIC CURRENT Compliance to EN60-3-2,-3 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 89% 90% RSP-3000-48 0mp-p 43 ~ 56 57.6 ~ 67.2 9.6 ~ 56 EMS IMMUNITY Compliance to EN60-4-2,3,4,5,6,8,11; EN504, EN55024, light industry level, criteria A MTBF 104.5K hrs min. MIL-HDBK-217F (25 ) DIMENSION 278*177.8*63.5mm (L*W*H) PACKING 4Kg; 4pcs/16Kg/1.89CUFT 48 62.5A 0 ~ 62.5A 3000W 90 5 (12), 110 5 (24), 105 5 (48) (T1: detect on heatsink of power transistor) 90 5 (12), 85 5 (24), 75 5 (48) (T2 : detect on heatsink of o/p diode) File Name:RSP-3000PEC 08-12-09
+ 3000W Single Output Power Supply Mechanical Specification 278 236.3 27 Case No.982B Unit:mm 38 12.5 63.5 8-M4(Both Sides) L=5mm 236.3 27 4-M4 L=5mm 7.9 OUTPUT 4 LED SR CN1 CN2 CN3 8 6 4 2 8 6 4 2 10 8 6 4 2 7 5 3 1 7 5 3 1 9 7 5 3 1 Air flow direction 162 177.8 INPUT TB1 13 10 1 2 3 16max. Block Diagram I/P AC Input Terminal Assignment 1 2 3 Assignment FG Assignment Assignment Assignment Assignment 1 P OK GND 4 P OK2 7 G 10 OLD 2 P OK 5 G 8 3 P OK GND2 6 9 OLP P OK GND: Power OK Ground P OK: Power OK Signal G: Remote ON/OFF Ground EMI ACTIE INRUSH CURRENT LIMITING G: Auxiliary Ground : Remote ON/OFF : Auxiliary Output PFC PFC O.T.P. POWER 1 2 3 4 PWM LOAD SHARING Assignment G P PS OLP: OLP Signal OLD: OLP Shutdown Signal POWER ITCHING O.L.P. FAN 5,7 6 8 G: Remote ON/OFF Ground : Remote ON/OFF P :Output oltage External Control PS : Reference oltage Terminal Control Assignment(CN3) : HRS DF11-10DP-2DS or equivalent Control Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent Assignment Mating Housing Terminal (Current Share) HRS DF11-8DS HRS DF11-**SC or equivalent or equivalent O..P. DETECTION CIUIT REMOTE : -Remote Sensing : Load Share : +Remote Sensing Mating Housing HRS DF11-10DS or equivalent Terminal HRS DF11-**SC or equivalent PFC fosc : 88KHz PWM fosc : KHz P OK POWER (12/0.1A) File Name:RSP-3000PEC 08-12-09
Derating Curve Static Characteristics Ta=25 90 LOAD (%) 50 LOAD (%) 70-0 10 30 50 70 AMBIENT TEMPERATURE ( ) (HORIZONTAL) 1 185 190 195 0 210 2 230 2 250 264 INPUT OLTAGE () Hz Function Manual 1.Remote ON/OFF (1)Remote ON/OFF control becomes available by applying voltage in CN1 CN2 CN3 (2)Table 1.1 shows the specification of Remote ON/OFF function (3)Fig.1.2 shows the example to connect Remote ON/OFF control function Table 1.1 Specification of Remote ON/OFF Connection Method Fig. 1.2(A) Fig. 1.2(B) Fig. 1.2(C) Output on Open Open Close Logic Output off Close Close Open Fig.1.2 Examples of connecting remote ON/OFF (A)Using external voltage source (B)Using internal 12 auxiliary output 12 12 typ. G 12 typ. G G G (C)Using internal 12 auxiliary output 12 typ. G G File Name:RSP-3000PEC 08-12-09
2.Alarm Signal Output (1)Alarm signal is sent out through "P OK" "P OK GND" pins (2)An external voltage source is required for this function. The maximum applied voltage is 50 and the maximum sink current is 10mA (3)Table 2.1 explain the alarm function built-in the power supply Function Description Output of alarm(p OK) Output of alarm(p OK2) POK The signal is "Low" when the power supply is above % of the rated output voltage-power OK The signal turns to be "High" when the power supply is under % of the rated output voltage-power Fail Table 2.1 Explanation of alarm Low (0.5 max at 500mA) High or open (External applied voltage 500mA max.) Low (0.5 max at 10mA) High or open (External applied voltage 10mA max.) POK POK2 R R 0.1uF POKGND External voltage and R (The max. Sink is 500mA and 30) P OK GND2 External voltage and R (The max. Sink is 10mA and 30) Fig. 2.2 Internal circuit of P OK (Relay, total is 10W) Fig. 2.3 Internal circuit of P OK2 (Open collector method) 3.Output oltage TRIM (1)Adjustment of output voltage is possible between ~110%(Typ.) of the rated output which is shown in Fig. 3.1 (2)Connecting a resistor externally between P and on CN1 or CN2 that is shown in Fig. 3.2. 1 out OP >1% P 1~6 OUTPUT OLTAGE (%) Non-Linear OUTPUT CURRENT (%) 1 2 3 4 5 6 EXTERNAL OLTAGE (DC) Fig. 3.1 External voltage (Typ.) 1 OUTPUT OLTAGE (%) File Name:RSP-3000PEC 08-12-09
4.Current Sharing (1)Parallel operation is available by connecting the units shown as below (, and are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 2% is required (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(the rated current per unit) x (Number of unit) x 0.9 (4) In parallel operation 2 units is the maximum, please consult the manufacture for other applications (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit No.1(Master) CN1 No.2(Slave) CN2 Load CN1 CN2 File Name:RSP-3000PEC 08-12-09