IN-LLT-C. Submersible Level Transmitter. 1.1 Description. 2.1 Specifications.

Similar documents
MPM480 Piezoresistive Pressure Transmitter

ED701 General Industry Pressure Transmitter

Features. Introduction. Specification. MPM480 Piezoresistive Pressure Transmitter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For oils and fuels Model LF-1

MANUAL HYDROBAR. Manufactured by: Fax: H/US/Hydrobar/ /00 Klay Instruments Page 1

bar, Type 413xA..., 414xA... Technical Data (based on Tref = 25 C; power supply 1 ma constant) Type 413xA... 0,2... 0,

Modus M Series. General Eastern Differential Pressure Transmitters. GE Sensing

Pressure Transducer Handbook

Submersible pressure sensor For superior applications Model LF-1

General Specification

PAD - Heavy Duty Differential Pressure Trasmitter

Manostar Electronic Low Differential Pressure Measurement System

MODEL AT-10 ANALOG TRANSMITTER

Series T. General Eastern Differential Pressure Transmitters. GE Sensing. Description

Freescale Semiconductor Data Sheet: Technical Data

Features. Picture. Specifications

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

XPC10 High temperature miniature pressure sensor

PA-850 PRESSURE TRANSDUCERS WITH AMP. PA R - N R2 FEATURES MODEL NUMBER DESIGNATION

MANUAL HYDROBAR. Manufactured by: 7991 CZ DWINGELOO 7990 AA DWINGELOO The Netherlands

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Non-Submersible Industrial Pressure Transducer

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

DPharp OVERVIEW PRESSURE SENSORS INTRODUCTION FEATURES. Resonant silicon sensor

DTM.OCS.S/N - Modbus Level Transmitter

HD 9408T BARO - HD 9408TR BARO HD 9908T BARO - HD 9408PS 50

PT-510 and PT-510W Series User Manual ma APG. Doc # Rev A, 02/2017

Pressure transmitter for general industrial applications Model A-10

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Pressure transmitter for general industrial applications Model A-10

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

High Pressure OEM Sensor RHU50

PTG series Smart Pressure Transmitter

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Flush pressure transmitter For viscous and solids-containing media Model S-11

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Model Sono-Trak Transit Time

ph or ORP Transmitter

December 2014 Ed 21. Testing and Recalibration

VARIABLE FREQUENCY DRIVE SPECIFICATION

Tank contents transmitter

Screw-in resistance thermometers with plug connector

General Specifications

Wind Direction Transmitter - compact

Series T. Amphenol Advanced Sensors. Differential Pressure Transmitters

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Type EXT with cable, probe sold

Monocrystalline silicon smart differential pressure transmitter. High stability. Benefits. application DRS

For clean water and sewage water NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Pressure transmitter For general industrial applications Model A-10

GasSense NDIR INFRARED TRANSMITTER

up to 200 C, 4007B... Technical Data 4007B, General Measuring range bar Overload bar Power supply ma* 1 Output signal (FS

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Relative Humidity & Temperature Transmitters

Pressure transmitter For general industrial applications Model A-10

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

Smart Displacer Level (Interface) Transmitter DLT100 Series

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

A Higher Level of Performance. Data Sheet. Hydrobar. Level Transmitters. For more information, please visit >

Ult r a s o n i c le v e l me t e r s ULM 55

Screw-in resistance thermometers with terminal head Form B

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

MICROMACHINED SILICON MODULAR PRESSURE SENSOR

Wind Direction Transmitter - compact - with Poti Output xx.712

4-20mA, 0-10V and general process measuring bargraph displays

KING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834

Installation and Operating Manual

FOR CLEAN WATER AND SEWAGE WATER HYDROSTATIC LEVEL TRANSMITTERS

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

Materials (other materials see WIKA diaphragm seal program) Model S-10

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Open Channel Flowmeter 713

Miniature pressure sensor

DRS390 High stability, flange mounting

DL.WMS/GPRS/R/SDI-12. Watermanager solution CUSTOMER BENEFITS

5. Transducers Definition and General Concept of Transducer Classification of Transducers

Water Cooled Absolute Pressure Sensor

Electromagnetic Flow Transmitter

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Thru-beam Sensors. Model SM800 Series. Ideal for small object detection

Datalogger DL/N 70 Version:

Water Cooled Absolute Pressure Sensor

Smart ALTJ3000 Immersion-type Liquid-Level Transmitter. Model: JTL220/230/221/231/222/232. User s Manual

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Freescale Semiconductor

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Photometer Maintenance Guide

WINTERS ( ) DI Digital Indicator HT Series Homogenizer Transmitter PTD Differential Transmitter PT Series

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure Transmitter SIL

Transcription:

IN-LLT-C Submersible Level Transmitter 1.1 Description. The Intech IN-LLT-C hydrostatic level transmitter is a fully sealed submersible pressure instrument. It is designed for liquid level measurement. The sensor and electronics are housed within a stainless steel IP68 housing and provide end users with an Industrial 4~20mA loop powered signal. The transducer diaphragm is mechanically protected by a steel cap that is designed to allow water / product free access to the diaphragm perform the measurement. Signal cable is sealed to the housing and contains the atmospheric pressure reference tube. IN-LLT-C units are designed for long term submersible operation. The IN-LLT-C piezo-resistive level transmitter has advantages of small size, light weight and long-term stability; it can be applied to measure and control in the petrochemical, medical, metallurgy, power station, mines, city water supply, drainage and hydrology survey and various other industries. 2.1 Specifications. Range (FS): m H 2 O 1 2 5 10 20 50 100 200 Overpressure: 2 times FS Accuracy: 0.5% FS Stability: range>20m H 2 O, 0.2% FS range<20m H 2 O, 20mm H 2 O Thermal drift: Zero Span range>10m H 2 O 0.02% FS/ C 0.05% FS/ C range>10m H 2 O 0.05% FS/ C 0.05% FS/ C Application temp. range: -10~80 C Storage temp. range: -40~100 C Output signal: 4~20mA (2-wire, Loop Powered) Power supply (U T ): 12~28Vdc Load (Ω): <(U T -12)/0.02 Product Liability. This information describes our products. It does not constitute guaranteed properties and is not intended to affirm the suitability of a product for a particular application. Due to ongoing research and development, designs, specifications, and documentation are subject to change without notification. Regrettably, omissions and exceptions cannot be completely ruled out. No liability will be accepted for errors, omissions or amendments to this specification. Technical data are always specified by their average values and are based on Standard Calibration Units at 25C, unless otherwise specified. Each product is subject to the Conditions of Sale. Warning: These products are not designed for use in, and should not be used for patient connected applications. In any critical installation an independent fail-safe back-up system must always be implemented.

3.1 Operation Principle. The measuring element of transmitter is a piezoresistive sensor, which transfers the pressure into electric signal by semiconductor silicon material s piezo-resistive effect. The measured pressure acts on stainless steel diaphragm, and then be transferred onto sensitive chip by silicon oil which is filled between the stainless steel diaphragm and sensitive chip (see figure 1). The sensitive chip is connected with transmitter special amplifying circuit by wires (see figure 2). Due to the good linearity relationship between the electric signal of Wheatstone bridge on the sensitive chip and the measured pressure, the pressure can be measured accurately. Blue Black Red Figure 1 Figure 2 White Yellow The basic principle of level measurement is that the liquid static pressure, proportioned with the liquid depth, is transferred into current (or voltage) signal output. The linearity corresponding relationship between electric signal output and the liquid depth is established to measure level or the liquid depth. See figure 3 for the level measurement principle Figure 3 P = γ. h. P is the liquid static pressure at the measuring point; γ is the liquid specific gravity; h is the depth from the measuring point to the liquid surface, or level. 3.2 Calculation Examples. Using a level transmitter with pressure range 10mH 2 O, 2-wire, 4~20mADC output to measure the level of some pool, the water gravity is 1.0. If the output is 10mA, what is the measured level? Solution:I = 4 + K P.. Put formula P = γ h into formula : I = 4 + K h γ I is the output current value, the unit is ma; 4 is the zero output of transmitter, 4mA; K is the transmitter sensitivity, or the ratio of transmitter FS output(this example is 20-4 = 16mA) to range(this example is 10mH 2 O. For this example, 16mA/10mH 2 O = 1.6 (ma/mh 2 O). This value has been given in product qualify certificate. h is the level,the unit is m; γ is the liquid gravity, this example is 1.0; From formula, we get: I 4 h =.. K γ I 4 12 4 8 Put all the values into formula, we have h = = = =5(m) K γ 1.6 x 1 1.6 The measuring result is five meters. 2

4. Construction and Outline Dimension 4.1 Construction Material Housing:Stainless Steel 1Cr18Ni9Ti O -Ring:Fluorine-rubber Rubber Bushing:Nitrile Butadiene Rubber Cable:φ7.5mm Polyethylene Special Cable Diaphragm:Stainless Steel 316L : Casting Aluminum (ZL102) 4.2 Construction 98 68?16?26 Figure 4 4.3 Outline and Dimension See figure 4 for dimensions. Cable Length: assembled according to customers options; longest cable could be 500 meters. : Please specify if a connection box is to be connected to the IN-LLT-C when ordering. Indicator: only for transmitter with 2-wire, 4~20mAdc output and connection box A, indicator could be provided according to the options. A Figure 5 B 5. Unpacking, Storage and Shipment Enclosed 5.1 Unpacking. Attention: 1. Avoid knocking violently when opening to prevent damaging instruments or accessories. Please be careful to prevent the housing and rubber casing of transmitter cable from damage. 3

5.2 Enclosed The transmitter includes: IN-LLT-C Piezoresistive level transmitter 1 Polyethylene Special Cable(connected with transmitter) ed length (connected with cable) Indicator(in connection box A Product Operation Manual 1 Product Quality Certificate 1 Quality Tracking Card 1 Power Supply Digital Displaying Instrument 5.3 Storage The transmitter should be stored in dry and ventilative room with ambient temperature -40~120 C, relative humidity no more than 85% and the air in the room without corrosive gas. 6. Installation 6.1 Check before Installation Attention before transmitter installation: The static pressure produced by the liquid at installation place exceeds the transmitter FS or not. The measuring liquid is compatible with the transmitter construction material or not. The measuring liquid may stop up the holes on the protection cap or not. 6.2 Installation Methods The transmitter should be installed vertically down. In the flowing water, the acted surface should be parallel with the water flowing direction. 6.2.1 Installation in Static Water For installation in static water see figure 6. To prevent shaking or destroying the transmitter when pumping, the transmitter should be put away from the liquid resource. Otherwise it should be installed as per figure 7, protected by steel tube. For installation in a deep well see figure 7. A steel tube insertion method is usually used. The steel tube cannot be bent; the diameter of steel tube must be more than 30mm. Several holes should be made at different heights on the tube so as to easily raising and make water flow smoothly. If necessary, wrap steel wire around transmitter to prevent breaking the cable by lifting with the steel wire. An aerial cable or the cable passing steel tube on the ground Control House Bracket Fixed Clamp Sediment Steel Tube Figure 7 Figure 6 4

6.2.2 Installation in Flowing Water (e.g. river channel, reservoir area, etc) Water-calming equipments are required. Method one: Insert a steel tube in the water channel (see figure 8). The steel tube wall should be thicker, and several holes should be made at different heights on the tube to damp waves and clear the water pressure influence. Method two: Superficial burying is better in the sand and stone channel (see figure 9). Flow Direction Figure 8 Figure 9 Method three: see figure 10. This method can not only clear water flowing pressure and wave influence, but also filter the sand and mud. Air Pocket Damper Figure 10 6.3 Electrical Connection Wires should be connected based on terminal definitions on production quality certificate. See the following steps for the specific method. 6.3.1 Electrical Connection method with Two-wire 4~20mADC output See figure 11 (Cable connection). Transmitter Figure 11 DC Supply Black Input Red Load Amperemeter 4-20mADC Output 5

6.3.2 Electrical connection method of transmitter with connection box There is a terminal connection board in transmitter connection box, and the terminal definitions are indicated in figure 12. OV/+OUT +V GND 6.4 Reference Tube Installation 1 2 3 Figure 12 There is a plastic tube in the transmitter special cable; the back pressure cavity of gauge sensor is connected to atmosphere by this tube. In the process of installation and operation, be sure to keep the reference tube be well connected with the atmosphere. Mud or sand should not be jammed into the reference tube. Prevent water or other liquid going through the reference tube to destroy the transmitter. 7. Operation, Maintenance and Fault Diagnosis 7.1 Operation The customer could operate the transmitter without adjustment. Please be sure that the installation and electrical connection are correct or not before operation. Connect the excitation and operate. The transmitter could work at once as soon as it is connected with excitation, but the output signal could be more reliable after 30 minutes. 7.2 Maintenance The IN-LLT-C level transmitter does not need to be maintained regularly, but please pay attention to items as follow for better operating effect and reliability. Check wire connection is reliable or not, and the cable is broken and old or not. Clean the protection cap and diaphragm cavity periodically(take care!) Don t violently pull cables or poke the diaphragm with metal or other hard objects. 7.3 Fault Diagnosis The IN-LLT-C level transmitter is an integrative full-sealed construction without movable parts inside, owning advantage of long-term stability and reliability. If some failures occur, such as no output, output too big or too small and unreliable, please turn off the excitation firstly, then check the installation and wire connection conform with the operation manual or not, the excitation is correct or not and the reference tube is unobstructed or not. If unsuccessful, the transmitter may be damaged; please contact Intech Instruments. Notes: 1. In the event that IN-LLT-C units are being used with media other than water please ensure that the seals and cable will not be compromised. 2. Two kinds of cable are available; Polyethylene (PE) & Polyurethane (PUR). Polyethylene cable is the stock standard. 3. If the IN-LLT-C is prone to lightning strikes, we strongly recommend the use of the optional LPN-OVP to protect the device. 4. At standard conditions: (@4 C, g=9.80665 m/s 2 ) 1mH 2 O = 0.1kgf/cm 2 = 9.80665kPa 5. For special requirements, please feel free to contact us. www.intech.co.nz Christchurch Ph: +64 3 343 0646 Auckland Ph: 09 827 1930 Email: sales@intech.co.nz 6 IN-LLT-C 181012