Ontario Provincial Standards 301 St. Paul St., 2 nd Floor North St. Catharines, ON L2R 7R4 Telephone: 905-704-2258 Fax: 905-704-2051 REVISION INFORMATION SHEET ONTARIO PROVINCIAL STANDARDS FOR ROADS AND PUBLIC WORKS VOLUME 4 DRAWINGS FOR ELECTRICAL WORK MANUAL REVISION #20 NOVEMBER 2005 Each Owner is responsible for determining implementation dates and directions for use of Ontario Provincial Standards; therefore, manual holders are cautioned about immediately discarding superseded and cancelled drawings. NEW METHOD FOR PUBLISHING ONTARIO PROVINCIAL STANDARDS With this publication of the Ontario Provincial Standards comes a new method of publishing the standards, both specifications and drawings. Now the Ontario Provincial Standards are available online with free access on the Ontario Ministry of Transportation (MTO) Library site at: <https://www.raqsa.mto.gov.on.ca/techpubs/ops.nsf/opshomepage>. At this URL, you will find the latest versions of the published standards, archives of the previously published standards, Revision Information Sheets for currently and previously published standards, indexes for each OPS volume, and OPS User Notes. Hard-copy paper versions of the standards are available through Publications Ontario and may be ordered online for a nominal fee at: <http://pubont.stores.gov.on.ca/pool/english/catalogue.asp>. At this URL, you can type Ontario Provincial Standards in the search box, and all related products for the Ontario Provincial Standards will be listed, click on the item you wish to purchase, add the item to your cart, then follow the instructions to complete your order. Hard-copy versions of OPS Volumes 1 to 3 are sold as an item, and OPS Volume 4 is sold separately. Planned for December release will be OPS Volumes 1 to 4 in PDF format on CD and OPS Volumes 3 and 4 in AutoCAD format on a separate CD. Most revisions to the Ontario Provincial Standards are published at the end of November each year. There may also be a limited publishing at the end of April each year for issuing OPSS 127, Schedule Of Rental Rates For Construction Equipment, Including Model And Specification Reference; correcting errors in recently published standards; and issuing time-sensitive revised standards. The Ontario Provincial Standards for Roads and Public Works organization is working with Publications Ontario to develop a system of notifying OPS users, regardless of the source from which they purchased their hard-copy standard volumes. Every effort is being made to ensure a smooth transition from one publisher to the next so OPS users are made aware of revisions to the standards as they are published. It is our intention to keep OPS users informed of available updates to the standards. Rev. Info Sheet - OPS Volume 4: Rev. Number 20 (Date: 11/2005) Page 1
WAITING TO HEAR FROM YOU If you have a suggestion to revise a standard or you have a standard that works in your ministry, municipality, or area, send it to the Head, OPS Administration, for possible inclusion into the Ontario Provincial Standards. This manual is revised as follows: Index Pages Volume 4 Please remove the entire index and replace with the attached revised index. Standard Drawings Volume 4 Superseded/Cancelled (Remove) Revised/New (Insert) Remarks OPSD Revision OPSD Revision 2121.010 -- -- -- Cancelled ELECTRICAL HANDHOLE, URETHANE ELASTOMER The urethane elastomer electrical handhole is no longer being produced. 2200.01 -- 2200.01 1 CONCRETE FOOTING FOR BASE MOUNTED LIGHTING AND SIGNAL POLES See Summary 2200.04 -- 2200.04 1 CONCRETE FOOTING AND ANCHORAGE ASSEMBLY FOR 3.3 m BASE MOUNTED METAL POLE See Summary -- -- 2210.030 0 New Drawing HIGH MAST LIGHTING POLE, APRON 2215.02 1 2215.02 2 ANCHORAGE ASSEMBLY See Summary -- -- 2421.010 0 New Drawing LAMP WATTAGE LABEL FOR LUMINAIRE -- -- 2453.060 0 HIGH MAST LIGHTING POLE, FLOOD LIGHT LUMINAIRE MOUNTING DETAILS Supersedes 2458.01. See Summary -- -- 2453.090 0 New Drawing HIGH MAST LIGHTING POLE, LUMINAIRE SHROUD -- -- 2453.091 0 New Drawing HIGH MAST LIGHTING POLE, LUMINAIRE SHROUD DETAILS -- -- 2453.170 0 HIGH MAST LIGHTING POLE, INTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 347/600V, 3-PHASE, WIRING DIAGRAM Supersedes 2460.01. See Summary Page 2 Rev. Info Sheet - OPS Volume 4: Rev. Number 20 (Date: 11/2005)
Superseded/Cancelled (Remove) Revised/New (Insert) Remarks OPSD Revision OPSD Revision -- -- 2453.180 0 HIGH MAST LIGHTING POLE, INTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 120/240V, 1-PHASE, WIRING DIAGRAM Supersedes 2460.02. See Summary -- -- 2453.210 0 HIGH MAST LIGHTING POLE, EXTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 347/600V, 3-PHASE, WIRING DIAGRAM Supersedes 2460.01. See Summary -- -- 2453.220 0 HIGH MAST LIGHTING POLE, EXTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 120/240V, 1-PHASE, WIRING DIAGRAM Supersedes 2460.02. See Summary 2458.01 -- -- -- HIGH MAST LIGHTING LUMINAIRE SUPPORT RING ASSEMBLY Superseded by 2453.060 2460.01 -- -- -- HIGH MAST LIGHTING POLE WIRING DIAGRAM, 600/347 V, 3- PHASE Superseded by 2453.170 and 2453.210. 2460.02 -- -- -- HIGH MAST LIGHTING POLE WIRING DIAGRAM, 120/240 V, 1- PHASE Superseded by 2453.180 and 2453.220. 2521.03 -- -- -- Cancelled PROBE DETECTOR AERIAL INSTALLATION Probe detectors are no longer being used. Rev. Info Sheet - OPS Volume 4: Rev. Number 20 (Date: 11/2005) Page 3
SUMMARY OF REVISIONS TO OPSD 2200.01 November 2005 CONCRETE FOOTING FOR BASE MOUNTED LIGHTING AND SIGNAL POLES Plywood template added. Elevation Dimensions title revised to Elevation Layout. In the Elevation Layout view, rigid duct sleeve installation requirements revised. In the Elevation Reinforcement view, approved equal for fibre tubing deleted. In the Elevation Reinforcement view, labelling revised. Note 2 rewritten. Note 3 added. SUMMARY OF REVISIONS TO OPSD 2200.04 November 2005 CONCRETE FOOTING AND ANCHORAGE ASSEMBLY FOR 3.3 m BASE MOUNTED METAL POLE Plywood template added. Pole deleted. In the Concrete Footing Elevation view, duct sleeve material and installation requirements revised. In the Concrete Footing Elevation view, rock deleted. In the Concrete Footing Elevation view, labelling revised. Anchorage Assembly Plan view added. In Anchorage Assembly Elevation view, stub dimensioned. In Anchorage Assembly Elevation view, length of stud revised from 200 to 130 mm. In Anchorage Assembly Elevation view, strut requirements revised. In Anchorage Assembly Elevation view, height of base bottom above top of concrete footing revised. Note 1 rewritten. Notes 2 and 3 added. SUMMARY OF REVISIONS TO OPSD 2215.02 November 2005 ANCHORAGE ASSEMBLY In the Elevation view, labelling revised. In Detail A, plywood thickness revised from 19 to 20 mm. Page 4 Rev. Info Sheet - OPS Volume 4: Rev. Number 20 (Date: 11/2005)
SUMMARY OF REVISIONS TO OPSD 2453.060 November 2005 HIGH MAST LIGHTING POLE, FLOOD LIGHT LUMINAIRE MOUNTING DETAILS In the Plan view, dimensions deleted and labeling revised. Tenon Details deleted. In Detail A, hole locations revised. In Detail A, mounting location of the floodlight luminaire mounting pad revised. Existing Note 1 deleted. Existing Note 2 revised and renamed to Note A. Other note reordered. New Notes 1 and 2 added. SUMMARY OF REVISIONS TO OPSD 2453.170 November 2005 HIGH MAST LIGHTING POLE, INTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 347/600V, 3-PHASE, WIRING DIAGRAM OPSD 2460.01 was separated into two drawings: OPSD 2453.170 for the internal drive raising and lowering equipment and OPSD 2453.210 for the external drive raising and lowering equipment. Schematic Diagram added. Note A added. SUMMARY OF REVISIONS TO OPSD 2453.180 November 2005 HIGH MAST LIGHTING POLE, INTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 120/240V, 1-PHASE, WIRING DIAGRAM OPSD 2460.02 was separated into two drawings: OPSD 2453.180 for the internal drive raising and lowering equipment and OPSD 2453.220 for the external drive raising and lowering equipment. Schematic Diagram added. Note A added. Rev. Info Sheet - OPS Volume 4: Rev. Number 20 (Date: 11/2005) Page 5
SUMMARY OF REVISIONS TO OPSD 2453.210 November 2005 HIGH MAST LIGHTING POLE, EXTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 347/600V, 3-PHASE, WIRING DIAGRAM OPSD 2460.01 was separated into two drawings: OPSD 2453.170 for the internal drive raising and lowering equipment and OPSD 2453.210 for the external drive raising and lowering equipment. SUMMARY OF REVISIONS TO OPSD 2453.220 November 2005 HIGH MAST LIGHTING POLE, EXTERNAL DRIVE RAISING AND LOWERING EQUIPMENT, 120/240V, 1-PHASE, WIRING DIAGRAM OPSD 2460.02 was separated into two drawings: OPSD 2453.180 for the internal drive raising and lowering equipment and OPSD 2453.220 for the external drive raising and lowering equipment. Page 6 Rev. Info Sheet - OPS Volume 4: Rev. Number 20 (Date: 11/2005)