MBC DG GUI MBC INTERFACE

Similar documents
EULAMBIA ADVANCED TECHNOLOGIES LTD. User Manual EAT-EOM-CTL-2. Alexandros Fragkos

USB Line Camera 8M. Coptonix GmbH

PWM P108. Programming Instructions v 3.2 PWM Controller Software

MINIMUM SYSTEM REQUIREMENTS

Digital Microscope. User Manual

DMMDRV 2017 Software User Manual. Version: A1324 / December 2017 Manual Code: DSFEN A

IB Nov User s Manual. KFM Series Application Software. FCTester. Ver. 1.1

Mars-Energo. Volt/mA Calibrator CALMAR-S. User s manual Edition 3.1

PC: A. Place the Microtek CD-ROM into the CD- ROM drive. B. Follow the on-screen instructions to install the driver and software.

DMMDRV Software User Manual. Version: A10 50 / December 2015 Manual Code: DSFEN A

ModBox Pulse Generation Unit

5008 Dual Synthesizer Configuration Manager User s Guide (admin Version) Version valontechnology.com

ROTATING SYSTEM T-12, T-20, T-50, T- 150 USER MANUAL

CAD-MF. PC-Based Multi-Format ANI & Emergency ANI Display Decoder. Manual Revision: Covers Firmware Revisions: CAD-MF: 1.

Analog Discovery Arbitrary Function Generator for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

Quick Start Guide for the PULSE PROFILING APPLICATION

PHOTLINE. Technologies. LiNbO3 Modulators MMIC Amplifiers Instrumentations. Hervé Gouraud November 2009

M-16DX 16-Channel Digital Mixer

S100 Webcam. User s Manual

Agilent N7509A Waveform Generation Toolbox Application Program

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

GXCapture 8.1 Instruction Manual

Magic Wand Portable Scanner with Auto-Feed Dock. PDSDK-ST470-VP-BX2 User Manual

Mach 5 100,000 PPS Energy Meter Operating Instructions

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Scanner Utility for Microsoft Windows Version 9.6. User's Guide

User s Guide. DDS-3005 USB Operation Manual

Optika ISview. Image acquisition and processing software. Instruction Manual

S101v2 Webcam with adjustable focus

USER MANUAL. ScanFlex AUTOMATED SCANNING DEVICE SCANFLEX Rev 5.0

MIDLAND PROGRAMING G14

TOSHIBA MACHINE CO., LTD.

DigiScope II v3 TM Aperture Scope User s Manual

Brightness and Contrast Control Reference Guide

SDI. Table of Contents

Radio Link Starter Kit

FUJITSU TWAIN 32 Scanner Driver. Scanner Utility for Microsoft Windows Version User's Guide

APPLICATION NOTE. Computer Controlled Variable Attenuator for Lasers. Technology and Applications Center Newport Corporation

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

USB Multifunction Arbitrary Waveform Generator AWG2300. User Guide

The CO2 Sensor Calibration Kit

Audio Analyzer R&S UPV. Up to the limits

Veterinary Digital X-Ray System Quick Start Guide

IX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x

Happy Link Software INSTRUCTION MANUAL

IVCAD VNA Base Load Pull with Active/Hybrid Tuning. Getting Started v3.5

Issue No: MG025 Date: 05 June McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ Update procedure

NOVA. Getting started

Focusrite Saffire 6 USB. User Guide

USER S MANUAL PSO-120 V1.0.0

Installation & User Manual Micro-Image Capture 7

English QT V01 CANON INC PRINTED IN CHINA

MMS TESTER FG320 OPERATING INSTRUCTIONS. valid from 11/2017. Machine Monitoring Systems

TracQ. Basic Data Acquisition and Spectroscopy Software

K-DT1 Portable Radar Doppler Target User Manual

ScanGear CS-U 5.6. for CanoScan FB1210U Color Scanner. User s Guide

USB PWM Motor 8810-D. Manual. Date : July, 2013 Version :1.0

The Discussion of this exercise covers the following points: Differential-pressure transmitter. Differential-pressure transmitter

ModBox-1310nm-1550nm-NRZ 1310nm & 1550 nm, 28 Gb/s, 44 Gb/s Reference Transmitters

Exercise 4. Angle Tracking Techniques EXERCISE OBJECTIVE

SKF TKTI. Thermal Camera Software. Instructions for use

TC LV-Series Temperature Controllers V1.01

Multiple Instrument Station Module

ScanGear CS-U 6.0. for CanoScan D646U Color Scanner. User s Guide

EULAMBIA ADVANCED TECHNOLOGIES LTD. Datasheet EAT-EOM-CTL-1. Alexandros Fragos

Quick Start Guide. Setup and Scanning. Try the Additional Features. English

Virtual Flight Academy - Quick Start Guide

Quick Start Guide. Setup and Scanning. Try the Additional Features. English

Welcome to Polaroid PhotoMAX FUN!

APPLICATION NOTE. Computer Controlled Variable Attenuator for Tunable Lasers. Technology and Applications Center Newport Corporation

Getting Started with EAA Virtual Flight Academy

IC-400pro - RADIOAFICION.COM

NOVA. Getting started

DDS-3005 USB Arbitrary Waveform Generator and. Frequency Counter. Operation Manual V1.9

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

2012 Monitored Rehab Systems E1201 Manual Kneelax. Installation and user manual

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

inphoto ID PS Automatic ID photography With Canon PowerShot camera User Guide

Line 6 GearBox Version 2.0 Release Notes

MADEinUSA OPERATOR S MANUAL. RS232 Interface Rev. A

User s Guide Wide Format Scanners. Models: IQ Quattro series

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

WPE 48N USER MANUAL Version1.1

Antenna and Propagation

PROGRAMMING MANUAL PCCONFIGURE SOFTWARE. December 2004 Part No

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

LM-QPSK-R. Lightwave Modulator for QPSK/ QAM. Features. Applications. Functional Diagram

Combo Scanner. User Manual

Table of Contents. Introduction...2. What s in the Box?...2. Fast Track USB Features...2. System Requirements...2. Windows...2. Macintosh...

Radio Link Starter Kit

Field Device Manager Express

AIT2000 CLASS B AIS TRANSPONDER

Quick Start Guide. Setup and Scanning. Try the Additional Features. English

Calibration check of dosimeters measuring whole body vibrations. Calibration check bench user manual

BB60C Spectrum Analyzer User Manual

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

Before using the Device. Using your Drifta. Connecting to a PC

The new Minolta DiMAGE Scan Elite 5400 film scanner

Transcription:

MBC DG GUI MBC INTERFACE User Manual Version 2.6

Table des matières Interface - Introduction... 3 Interface - Setup... 3 Minimum Computer Requirements... 3 Software installation... 3 Hardware Setup... 3 Interface - Operation... 4 General considerations... 4 Setting bias control parameters... 6 Saving and loading bias control parameters... 8 Bias monitoring... 9 Bias data recording... 10 Manual mode... 12 Diagnostic... 13 ANNEXE:... 15

Interface - Introduction Photline proposes a graphical user interface to simplify bias control management for the ModBox and MBC products family. Based on a RS232 serial communication and a Visual Basic interface, bias parameters are strictly similar also whole bias control are tunable and could be saved and loaded. Interface - Setup Minimum Computer Requirements Processor 1 GHz with 512MB RAM Disk space (minimum) 32-bit : 600 MB 64-bit: 1.5 GB Windows XP Professional SP3 One USB port for each MBC to drive. Software installation 1/ Log on with an administrator account. 2/ Insert the Photline CD-ROM into the CD drive or plug the USB key. 3/ Install setup.exe (system restart maybe required) 4/ Install USB MBC Drivers (if needed) 5/ Run MBC DG Control.exe file Hardware Setup 1. Connect USB cable to the controller rear panel and the PC 2. Plug the power cable and switch on the device. 3. USB MBC connexion will be seen as COM peripheral by your PC

Interface - Operation General considerations One needs to choose the COM port. To proceed, click on the down arrow of the list box and select the COM port connected to the controller. After selecting your port, click on Connect to obtain your S/N number and activate the rest of the interface.

Once done, the MBC serial number will be displayed.

Setting bias control parameters Standard Mode: Figure 1: Bias control standard parameters Auto-Calibration button: A scan of the system is performed in order to find the right MBC parameters for the 3 most used setting points: QUAD, MIN, MAX. (see Annexe for details) Scan Restart button: The bias control routine is reinitialised. This is recommended to restart the feedback control when some parameters have been changed (Dither amplitude, Dither frequency, Photodiode gain). Refresh Screen button: Application reloads all parameters from the board. Save Config button: Current configuration is saved in one of the 3 configuration area. (Config 1-3). Load Config button: Selected configuration is loaded into MBC (Config 1-3).

Advanced Mode: Figure 2: Bias control advanced parameters Running Mode DC Bias Voltage Transfer Level Dither Frequency Dither Amplitude Photodiode Polarity Photodiode Gain : Auto / Manual : From 10 to +10V (variable step) : From 100% to +100% (0.1% step) : From 400 to 1400Hz (40Hz step) : From 10 to 1000mV (typically 10mV step) : Inverted or Non Inverted (Non Inv.) : From 1 (Low) to 127 (High) After setting a value, it has to be validated with Send button. The validation is effective only when Send button restore its initial colour.

Saving and loading bias control parameters Figure 3 : bias control parameters save and load buttons Save : All bias control parameters are saved in a file for further loading. The user specifies the file name and its path through a dialog box. Load button : All bias control parameters are loaded from a file specified by the user in a dialog box.

Bias monitoring Figure 4: bias monitoring control DC bias is always monitored, you can clear or save the graph.

Bias data recording The Records function allows saving a measure with a specific step time. It saves in a text file, time and DC bias value. Figure 5 : start recording bias values The Record button starts the bias recording procedure. First step: Set the time interval between each record with Step Time and the record duration with Total Time in hour. Total time at 0 means recording until Stop button is pressed. Second step: Press Records button and a dialog box appear to set the file name and destination folder. Third step: Press Save button in the dialog box to launch record procedure.

Figure 6 : stop recording bias values At any time it is possible to stop the record procedure by clicking on the Stop button (See Figure 6).

Manual mode figure 7 :bias control in manual mode In Manual Mode, the Bias control works as a DC voltage source. The applied bias is adjusted by decreasing / increasing the DC Bias Voltage (See Figure 7). It is also possible to change the step.

Diagnostic: Diagnostic is a function which is used by our support team. It will help us understand and see what can be your feedback loop problem. Click on Diagnostic and enter the Password: trepxe. figure 8 :bias control in manual mode

You obtain a new tab: figure 9 :bias control in manual mode Click on tab diagnostic and send an email to us with the diagnostic file.

ANNEXE: Auto calibration step: Step Quad Min / Max 1 Apply a dither of 120mV Apply a dither of 120mV 2 Do a scan to detect DC Vπ Do a scan to detect DC Vπ 3 Dither is set to 3% of Vπ Dither is set to 3% of Vπ 4 Set modulator to Quad point Set modulator to Quad point 5 Increase Photodiode Gain until obtaining a value of 2Vpp on our ADC. Photodiode Gain is limited to 120 Increase Photodiode Gain until obtaining a value of 2Vpp on our ADC Photodiode Gain is limited to 120 6 Do a Scan Set the dither to 0.25% of Vπ 7 Board is locked to Quad Point Do a Scan 8 Board is locked to Min or Max Point If the feedback loops oscillate, you can reduce the Photodiode Gain in order to stabilize the loop (reducing from 5 to 20 is generally enough).