RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Similar documents
SEPARATOR P20G TYPE USER S MANUAL

TEMPERATURE CONTROLLER RE21 TYPE

DIGITAL PANEL METER N24 AND N25 METER SERIES

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

PROGRAMMABLE TRANSDUCER OF DC CURRENT AND DC VOLTAGE SIGNALS P20H TYPE

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

N24, N25 DIGITAL PANEL METER

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

THREE-PHASE POWER CONTROLLER RP3 Type

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

TEMPERATURE CONTROLLER. MOUNTED ON A 35 mm RAIL RE60 TYPE USER S MANUAL

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

4-CHANNEL MODULE OF ANALOG INPUTS SM2 TYPE

High power radio transmission module MR03 type

a * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD

ND40 V V. Ethernet www/ ftp / smtp. Ethernet TCP IP RS-485 USB HOST /SD CARD.

POWER NETWORK PARAMETER METER N13 SERVICE MANUAL

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

POWER CONTROLLER RP1 type

Operating Manual MU2000K

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

N E W functions! Modbus. Wireless transmission - SM ma TCP IP ma. NA5 meter with bargraph. k *

HAWK5000 Operators Manual

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

N30P DIGITAL PANEL METER

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

MINI-PS AC/24DC/1.3

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

TRANSDUCER OF NETWORK PARAMETERS P43 TYPE

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Zelio Control Measurement Relays

Installation and Operating Instructions for Phase Demodulator Type _.2

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Power supply CP-E 24/2.5

Power supply CP-T 48/5.0 Primary switch mode power supply

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

Power supply CP-E 24/20.0

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Installation and Operational Instructions for ROBA -switch Type 017._00.2

High precision measurement system for current and voltage IHC-A/B-RM01/03

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Power supply CP-T 24/10.0 Primary switch mode power supply

MAVOWATT 4 Multifunction Power Meter

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

Power supply CP-T 24/40.0 Primary switch mode power supply

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

TEMPERATURE CONTROLLER RE55 TYPE USER S MANUAL

new! nd40 example of application MeaSUreMent and ViSUalization of power network parameters Ethernet www/ ftp / smtp Ethernet TCP IP RS-485

MINI-PS AC/2X15DC/1

I Pr I P I OUT R L. Applications. Standards

Power supply CP-E 24/0.75

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

METERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

DM-45 Digital Multimeter

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

SINEAX U 553 Transducer for AC Voltage

QUINT-PS/ 3AC/24DC/10

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

AC/DC Current Oscilloscope Probe Model SL261

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

QUINT-PS AC/24DC/40

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

RMO500 M I C R O O H M M E T E R

MS2030 CAT III 600 V A V AUTO RS232

Power supply CP-D 12/2.1

BENNING. CM7 Electrical Tester. Service Information

METRAClip87 and 88 Clamp Multimeters

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

USER S MANUAL. Rail-mounted temperature transmitter ATL

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Transcription:

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1

Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External connection diagram...11 5. HANDLING... 12 6. TECHNICAL DATA... 13 7. ORDER CODES... 16

1. ApplicAtion N27D meters are designed for direct a.c. measurement: voltage, current, frequency and active power. The design allows for installation of the meter for modular switchgear in accordance with EN 62208 (meter has a width of 3 modules) on 35 mm rail. The current is measured through current transformer (CT). Measured values are displayed on 4 -digit readout field. Switching between measured values is realized by pressing a button. Fig.1. View of the N27D meter. 5

2. METER SET The meter set includes: - N27D meter... 1 pc - user s manual... 1 pc - warranty certificate... 1 pc 3. BASIC REQUIREMENTS, OPERATIONAL SAFETY Symbols located in this service manual mean: WARNING! Warning of potential, hazardous situations. Especially important, one must acquaint with this before connecting the module. The nonobservance of notices marked by these symbols can occasion severe injuries of the personnel and the damage of the module. CAUTION! Designates a general useful note. If you observe it, handling of the meter is made easier. One must take note of this, when the meter is working inconsistently to the expectations. Possible consequences if disregarded!

In the security scope, the meter fulfills the requirements of the EEC Low-Voltage Directive (EN 61010-1 issued by CENELEC). Remarks concerning the operator safety: 1. General The N27D meter is designed to be installed in measuring systems. Non-authorized removal of the required housing, inappropriate use, incorrect installation or operation creates the risk of injury to personnel or damage to equipment. For more detailed information please study the user s manual. All operations concerning transport, installation, and commissioning as well as maintenance must be carried out by qualified, skilled personnel and national regulations for the prevention of accidents must be observed. According to this basic safety information, qualified, skilled personnel are persons who are familiar with the installation, assembly, commissioning, and operation of the product and who have qualifications necessary for their occupation. 2. Transport, storage Please observe the notes on transport, storage and appropriate handling. Observe the climatic conditions given in Technical Data. 3. Installation The meter must be installed according to the regulation and instructions given in this User s Manual. Ensure proper handling and avoid mechanical stress. Do not bend any components and do not change any insulation distances.

Do not touch any electronic components and contacts. Meters may contain electrostatic sensitive components, which can easily be damaged by inappropriate handling. Do not damage or destroy any electrical components since this might endanger your health! Wire cross-sections must be chosen such to assure the protection of the cable in case of a short-circuit, by means of an installation cut-off. Requirements concerning the mains supply are described in the EN 61010-1 standard. A cut-out or a circuit-breaker should be installed in the building and be easily accessible for the operator. 4. Electrical connection Before switching the meter on, one must check the correctness of connection to the mains supply. In case of the protection terminal connection with a separate lead, one must remember to connect it before the connection of the meter to the mains. When working on live meters, the applicable national regulations for the prevention of accidents must be observed. The electrical installation must be carried out according to the appropriate regulations (cable cross-sections, fuses, PE connection). Additional information can be obtained from the user s manual. The documentation contains information about installation in compliance with EMC (shielding, grounding, filters and cables). These notes must be observed for all CE-marked products. The manufacturer of the measuring system or installed devices is responsible for the compliance with the required limit values demanded by the EMC and LVDlegislation.

5. Operation Measuring systems including N27D meters must be equipped with protection devices according to the corresponding standard and regulations for prevention of accidents. After the instrument has been disconnected from the supply voltage, live components and power connections must not be touched immediately because capacitors can be charged. The housing must be closed during operation. 6. Maintenance and service Please observe the manufacturer s documentation. Read all product-specific safety and application notes in this user s manual. Before taking the meter out, ensure the power supply is off. The removal of the meter housing during the guarantee period may cause its cancellation The meter fulfills requirements related to electromagnetic compatibility in the industrial environment.

4. INSTALLATION 4.1. Mounting The meter is designed to be mounted on a 35 mm rail acc. to EN 60715. The meter is equipped with terminals which enable the connection of external wires with cross-sections: - input current signals: 2,5 16 mm 2 (solid wire), 4 16 mm 2 (stranded wire); - input voltage signals: 1,5 16 mm 2 (solid wire), 2,5 16 mm 2 (stranded wire); - supply: up to 2,5 mm 2. Meter dimensions are presented on the fig. 2 10 Fig. 2. Overall dimensions

Meters shouldn t be mounted on the rail in direct contact with another devices emitting heat (eg other meter N27D). You must keep a minimum 5 mm distance between the devices to allow emit heat from the housings to the ambient. Otherwise, temperature outside of meter which is in direct contact with the other device may exceed the rated operating temperature stated in operating conditions. 4.2. External connection diagram The power supply must be connected by a two-wire conductor of suitable wire cross-section ensuring its protection by an installation cut-out. Fig. 3. Electrical connections of the N27D meter 11

5. HANDLING Unit of displayed value Change displayed value Measured value Fig. 4. Front view. After connecting external signals and switching the supply on, the meter displays name N27d and software revision. Then displays default quantity voltage. One can change displayed quantity by pressing button. If button is pressed longer than 3 seconds, text save is displayed and displayed quantity is remembered as a default quantity. After switching on power supply the meter displays its default quantity. If voltage is in measured range then frequency is taken from voltage otherwise frequency is taken from current. 12

The appearance of following symbols on the display means: ---- ---- ErCA Measured value exceeds the upper value of the indication range. Measured value exceeds the lower value of the indication range. Loss of meter calibration values. In such a case, one must contact the service workshop. 6. TECHNICAL DATA Measuring range: INPUTS: Measuring range of voltage U: 0...0.01...1.2 Un - input resistance > 3 M Measuring range of current I: Voltage frequency measurement: Current frequency measurement: Active power measurement: Sustained overload: 0...0.01...1.2 In 0...2.0...500.0 Hz 0...45.0...500.0 Hz -45.4...-31.5...31.50...45.36 kw at frequency 45...65 Hz 120 % Un, 120 % In 13

Short duration overload (1 s): input voltage 2 Un (<1000 V) current input: 10 In Basic error: - voltage ± (0.5% of the range) in frequency range 40...500 Hz - current ± (0.5% of the range) in frequency range 45...65 Hz - frequency ± (0.02% of the range) - active power ± (1% of the range) in frequency range 45...65 Hz Additional errors in rated operating conditions: - from ambient temperature changes (50% of basic error/10 K) Preheating time: Measuring time: 15 minuts 0.5 s Rated operating conditions: - supply voltage: 230 V ± 10% a.c. (45...65 Hz) - input voltage Un: 500 V a.c. 0...2...40.0...500.0 Hz - input current In: 63 A a.c. 0...45.0...500.0 Hz - ambient temperature: -10...23...55 C - storage temperature: -25...+85 C - humidity: < 95% (condensation inadmissible) - work position: any - input signal: sinusoidal (THD 8%) 14

- admissible peak factor 2 Readout field: - display 4-digit LED - digit height 8.5 mm - color yellow - indication range: -1999...9999 Ensured protection grade: IP 00 acc. to EN 60529 Overall dimensions: Weight: 110 x 53 x 60 mm < 0.25 kg Power: - in supply input < 2 VA - in voltage input < 0.2 VA - in current input < 2.5 VA Test voltage: - voltage input 3.2 kv d.c. - current input 3.2 kv d.c. - power supply 2,1 kv d.c. Electromagnetic compatibility: - noise immunity acc. to EN 61000-6-2 - noise emission acc. to EN 61000-6-4 Safety requirements acc. to EN 61010-1: - isolation between circuits: basic, - installation category III up to 300 V (II for 300 600 V), - pollution grade 2, 15

- maximal phase-to-earth working voltage: - for the supply circuit 300 V, - for the measuring input 600 V cat. II (300 V cat. III) - altitude above sea level: < 2000 m. 7. ORDER CODES n27d- XX X X Version: standard 00 custom-made* XX Language: Polish P English E other* X Acceptance tests: without extra quality inspection requirements 0 with an extra quality inspection certificate 1 acc. to customer s request* X * only after agreeing with the manufacturer Example of order: The code: N27D - 00 E 0 means: 00 standard version, E English language, 0 without extra quality inspection requirements. 16

17

18

19

LUMEL S.A. ul. Słubicka 1, 65-127 Zielona Góra, Poland Tel.: (48-68) 45 75 100 Fax: (48-68) 45 75 508 e-mail:lumel@lumel.com.pl http://www.lumel.com.pl Export Department: Tel.: (48-68) 45 75 139/305/321/368 Fax: (48-68) 32 54 091 e-mail: export@lumel.com.pl 20 N27D-09A