Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 EMC TEST REPORT. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger

Similar documents
BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

EMC Test Report. Report Number: M030826

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

2620 Modular Measurement and Control System

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

EMC test report AU01+E04

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC Test report for LED Panel Light Models , , , , ,

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

TEST REPORT... 1 CONTENT...

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

1 SUMMARY OF STANDARDS AND RESULTS

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

TEST REPORT. Power Spout PLT V. tested to the specification

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC TEST REPORT. Report No.: CE10-LIE040101E

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

August 22, Ubiquiti Networks 91 E. Tasman San Jose, CA Dear Jennifer Sanchez,

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

Test Report GUANGDONG EAST POWER CO., LTD

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

C E R T I F I C A T I O N

ELECTRONICS TESTING CENTER(ETC), TAIWAN

r(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

TEST REPORT. EN / EN Information technology equipment Radio disturbance / Immunity characteristics Limits and methods of measurement

Declaration of Conformity.

A Comparison Between MIL-STD and Commercial EMC Requirements Part 2. By Vincent W. Greb President, EMC Integrity, Inc.

LAB engineer Milivoje Miletić

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Test and Measurement for EMC

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

PT. SARANA KARYA SOLUSINDO.

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

Global EMC Labs EMC / EMI Test Report

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

Communication Certification Laboratory

TEST REPORT. Information technology equipment

TEST REPORT EMC. 1, Mikhaila Kotzubinskogo St., Kyiv, Ukraine, IECCISPR14_1&2_IEC61000_3_2&3B

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

December 9, Ubiquiti Networks, Inc. 91 E. Tasman San Jose, CA Dear Jennifer Sanchez,

Power Sensors Ltd. PQube 3 AC Analyzer IEC Class 0,2 S Accuracy Compliance Report

SUMMARY... 1 CONTENT GENERAL INFORMATION...

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

CE-EMC TEST REPORT. Prepared for : T&T Assoociates London LTD Suite#306 CityGate House, Bussinedd Centre Stratford, Romford Road, London

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD

1. Electro-Static Discharge Test EN R Radiated Susceptibility Test EN R-2

EN v2.1.1 EN 55022: A1:2007 TEST REPORT FOR b/g/n 1x2 SISO NETWORKING DEVICE MODEL NUMBER: UNIFI AP MINI

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

March 11, Ubiquiti Networks Montague Expressway Milpitas, CA Dear Robert Pera,

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

Transcription:

Kutta Radio & charger Report Number: TRE0026-5/17 Page 1 of 27 ISERT (Pty) Ltd. Reg: 2017/186396/07 Tel: + 27 (0)12 548 0940 E-Mail: info@isert.co.za 129 Khai-Apple street Montana Pretoria 0186 EMC TEST REPORT TEST STANDARD(S) : ETSI EN 301 489-1: V2.1.1 (2017-02) DMR EMC Requirements CLIENT / APPLICANT : Advanced Comms (Pty) Ltd. TEST SAMPLE (EUT) : Kutta Medium frequency radio & Charger REPORT NUMBER : TRE0026-5/17 DATE ISSUED : 24/11/2017 REVISION : 1.0 ISERT (Pty) Ltd. Test reports apply only to the specific sample(s) tested under stated conditions. All samples tested were in good operating condition throughout the entire test program. It is the manufacturer s responsibility to ensure that additional production units of this model are manufactured with identical electrical and mechanical components. ISERT (Pty) Ltd. Shall have no liability for any deductions, inference or generalizations drawn by the client or others from ISERT (Pty) Ltd. Issued reports. This report shall not be used to claim, constitute or imply a product endorsement from ISERT (Pty) Ltd. continuous This test report was prepared by: Name: CJ Deysel Title: EMC Test Engineer This test report was reviewed by: Name: R van den Berg Title: Senior RF Engineer T0812 This test report is issued in accordance with SANAS accreditation requirements. SANAS is a signatory to the ILAC Mutual Recognition arrangement for the mutual recognition of the equivalence of testing and calibration reports

Kutta Radio & charger Report Number: TRE0026-5/17 Page 2 of 27 COPY NO NAME ORGANISATION MASTER CONFIGURATION LIBRARY Advanced Comms (Pty) Ltd. 1 CONFIGURATION LIBRARY ISERT REV DATE COMPILED BY PAGES AFFECTED CHANGE PROPOSAL 1.0 24/11/2017 CJ Deysel All N/A DIRECTORY C:\Users\johan\Google Drive\REPORTS\Johan\DMR Requirements\TRE0026-5 - Advanced Comms - Kutta Radio and charger - ETSI EN 301 489-1 and DMR.doc FILE NAME TRE0026-5 - Advanced Comms - Kutta Radio and charger - ETSI EN 301 489-1 and DMR LIST OF EFFECTIVE PAGES 1 9 17 25 2 10 18 26 3 11 19 27 4 12 20 5 13 21 6 14 22 7 15 23 8 16 24 APPLICANT INFORMATION Name Address: Contact person: Advanced Comms (Pty) Ltd. 108 Sandler Rd Glenhazel Johannesburg 2192 Herbert Schmitz

Kutta Radio & charger Report Number: TRE0026-5/17 Page 3 of 27 ABBREVIATIONS AAN AC AM AMN AVE CDN CISPR CSIR E-Fields EFT EMC EMI ESD EUT FAR H HCP LAN MME NIST NMISA NSA OATS PC QP RGP RF SANAS UHF V VCP Asymmetric Artificial Network Associated Equipment Amplitude Modulation Artificial Mains Network Average Coupling/ Decoupling Network International special committee on radio interference Council for Scientific and Industrial Research Electric Fields Electrical Fast Transients Electromagnetic Compatibility Electromagnetic Interference Electrostatic Discharge Equipment Under Test Fully Anechoic Room Horizontal Horizontal Coupling Plane Local Area Network Multimedia Equipment National Institute of Science and Technology National Metrology Institute of South Africa Normalized Site Attenuation Open Area Test Site Personal Computer Quasi-Peak Reference Ground Plane Radio Frequency South African National Accreditation System Ultra-High Frequency Vertical Vertical Coupling Plane

Kutta Radio & charger Report Number: TRE0026-5/17 Page 4 of 27 TABLE OF CONTENTS 1. INTRODUCTION... 7 2. STANDARDS APPLIED... 7 3. SUMMARY OF TEST RESULTS... 7 4. EMISSION CLASSES AND IMMUNITY CRITERIA... 8 4.1 EMISSIONS... 8 4.2 IMMUNITY CRITERIA... 8 4.2.1 Immunity... 8 5. ENVIRONMENTAL CONDITIONS DURING ESD TEST:... 8 6. CALIBRATION OF TEST EQUIPMENT... 8 7. MEASUREMENT OF UNCERTAINTY... 9 8. EQUIPMENT UNDER TEST... 9 8.1 EUT IDENTIFICATION... 9 8.2 EUT TEST SETUP DETAIL:... 9 8.3 SETUP IMAGES... 10 9. EMISSIONS... 11 9.1 RADIATED EMISSIONS:... 11 9.2 TEST SET-UP... 11 9.3 RADIATED EMISSIONS RESULTS: RADIO... 12 9.3.1 Radiated Emission: 30 MHz 1000MHz (Horizontal)... 12 9.3.2 Radiated Emission: 30 MHz 1000MHz (Vertical)... 12 9.3.3 Conclusion... 12 9.3.4 Radiated Emission: 1000MHz 6000MHz (Horizontal)... 13 9.3.5 Radiated Emission: 1000 MHz 6000 MHz (Vertical)... 13 9.3.6 Conclusion... 13 9.4 RADIATED EMISSIONS RESULTS: CHARGER... 14 9.4.1 Radiated Emission: 30 MHz 1000MHz (Horizontal)... 14 9.4.2 Radiated Emission: 30 MHz 1000MHz (Vertical)... 14 9.4.3 Conclusion... 14 9.4.4 Radiated Emission: 1000MHz 6000MHz (Horizontal)... 15 9.4.5 Radiated Emission: 1000 MHz 6000 MHz (Vertical)... 15 9.4.6 Conclusion... 15 9.5 CONDUCTED EMISSIONS: CHARGER... 16 9.5.1 TEST SET-UP... 16 9.6 CONDUCTED EMISSIONS RESULTS... 16 9.6.1 AC Input Live... 16 9.6.2 AC Input Neutral... 17 9.6.3 Conclusion... 17 9.7 SANS / IEC 61000-3-3 VOLTAGE FLUCTUATIONS & FLICKER... 18 9.8 TEST SET-UP... 18 9.8.1 Results... 18 9.8.2 Conclusion... 18 10. IMMUNITY... 19 10.1 SANS / IEC 61000-4-2 ESD IMMUNITY... 19 10.1.1 Set-up... 19 10.1.2 Results... 19 10.1.3 Conclusion... 20 10.2 SANS / IEC 61000-4-3 RADIATED IMMUNITY... 20 10.2.1 Set-up... 20 10.2.2 Results... 21 10.2.3 Conclusion... 21 10.3 SANS / IEC 61000-4-4 FAST TRANSIENT IMMUNITY... 21 10.3.1 Set-up and levels... 21 AC Power Port... 21 10.3.2 Conclusion:... 21

Kutta Radio & charger Report Number: TRE0026-5/17 Page 5 of 27 10.4 SANS / IEC 61000-4-5 SURGES... 22 10.4.1 Set-up and Test Levels... 22 AC Power Port... 22 10.4.2 Conclusion... 22 10.5 SANS / IEC 61000-4-6 CONDUCTED IMMUNITY... 23 10.5.1 Set-up and Test Levels... 23 10.5.2 Results... 23 10.5.3 Conclusion... 23 10.6 SANS / IEC 61000-4-8 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST... 24 10.6.1 Set-up... 24 10.6.2 Results... 24 10.6.3 Conclusion... 24 10.7 SANS / IEC 61000-4-9 PULSE MAGNETIC FIELD IMMUNITY TEST... 25 10.7.1 Set-up... 25 10.7.2 Results... 25 10.7.3 Conclusion... 25 10.8 SANS / IEC 61000-4-11 VOLTAGE DIPS AND INTERRUPTIONS... 26 10.8.1 Set-up and Test Levels... 26 10.8.2 Results... 26 10.8.3 Conclusion... 26 11. CONCLUSION... 27 11.1 COMPLIANCE STATEMENT... 27

Kutta Radio & charger Report Number: TRE0026-5/17 Page 6 of 27 LIST OF TABLES Table 3.1-1: Emissions results... 7 Table 3.1-2: Immunity results... 7 Table 9.2-1: Test equipment used for Radiated emission measurements... 11 Table 9.5-1: Test equipment used for Conducted emission measurements... 16 Table 9.7-1 Test equipment used for Voltage Fluctuations & Flicker test results... 18 Table 10.1-1 Test equipment used for ESD... 19 Table 10.1-2 Results of ESD Contact discharge... 19 Table 10.1-3 Results of ESD Air discharge... 20 Table 10.2-1 Test equipment used for Radiated Immunity.... 20 Table 10.3-1 Test equipment used for Electrical Fast Transients... 21 Table 10.4-1 Test equipment used for Surges... 22 Table 10.5-1 Test equipment used for Conducted Immunity.... 23 Table 10.6-1 Test equipment used for Power frequency magnetic Immunity.... 24 Table 10.7-1 Test equipment used for Pulse magnetic field Immunity.... 25 Table 10.8-1 Test equipment used for Voltage Dips and Interruptions... 26

Kutta Radio & charger Report Number: TRE0026-5/17 Page 7 of 27 1. INTRODUCTION This report details the results of tests performed on the Kutta Medium frequency radio & charger, henceforth referred to as Equipment Under Test (EUT). The EUT was tested between 20 24 November 2017 according to the following standards: 2. STANDARDS APPLIED DMR requirements for safety critical equipment as listed in Government Gazette 32885 of January 22, 2010 ETSI EN 301 489-1 V2.1.1 (2017-02) Electromagnetic compatibility and Radio Spectrum Matters (ERM) SANS 211 (2011) / CISPR 11 (2010 +A1:2010): Industrial, scientific and Medical (ISM) radiofrequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement 3. SUMMARY OF TEST RESULTS Table 4.1-1: Emissions results EMISSIONS: Standard Test Type Results Radiated emissions Pass SANS 211 / CISPR 11 Conducted emissions input power Pass SANS / IEC 61000-3-2 Harmonic current emissions Less than 75W - N/A SANS / IEC 61000-3-3 Voltage fluctuation & flicker Pass Table 4.1-2: Immunity results IMMUNITY: Standard Test Type DMR ETSI EN 301 489-1 SANS / IEC 61000-4-2 Electrostatic discharge immunity test Pass Pass SANS / IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test SANS / IEC 61000-4-4 Immunity to Electrical Fast Transient Pass Pass SANS / IEC 61000-4-5 Immunity to Surges Pass Pass SANS / IEC 61000-4-6 Immunity to Conducted Disturbances Pass Pass SANS / IEC 61000-4-8 Power frequency magnetic immunity test Pass N/A SANS / IEC 61000-4-9 Pulse magnetic field immunity test Pass N/A SANS / IEC 61000-4-11 Voltage dips Pass Pass SANS / IEC 61000-4-11 Voltage interruptions Pass Pass Pass Pass The EUT meets all the requirements of the standards applied

Kutta Radio & charger Report Number: TRE0026-5/17 Page 8 of 27 4. EMISSION CLASSES AND IMMUNITY CRITERIA 4.1 EMISSIONS CISPR 11 Separation into groups Group 1 equipment: group 1 contains all equipment in the scope of this standard which is not classified as group 2 equipment. Group 2 equipment: group 2 equipment contains all ISM RF equipment in which radio-frequency energy in the frequency range 9 khz to 400 GHz is intentionally generated and used or only used, in the form of electromagnetic radiation, inductive and / or capacitive coupling, for the treatment of material or inspection / analysis purposes Division into classes Class A ISM equipment is equipment suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Class A equipment shall meet class A limits. Warning: This equipment is compliant with Class A of SANS 211 / CISPR 11. In a residential environment this equipment may cause interference Class B ISM equipment is equipment suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Class B equipment shall meet class B limits. 4.2 IMMUNITY CRITERIA 4.2.1 Immunity The Criteria set-out above are defined as follows: Criteria A: normal performance within limits specified by the manufacturer, requestor or purchaser; Criteria B: temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment under test recovers its normal performance, without operator intervention; Criteria C: temporary loss of function or degradation of performance, the correction of which requires operator intervention; 5. ENVIRONMENTAL CONDITIONS DURING ESD TEST: Temperature: 22-23C Relative Humidity: 45-53% 6. CALIBRATION OF TEST EQUIPMENT The computer controlled EMI Measuring system is checked for amplitude and frequency accuracy with a signal generator (calibrated by a SANAS accredited laboratory and is traceable to the national standards maintained by NMISA) on a monthly basis. The calibration of the equipment is performed by Coral-I, Precision Measurements and Enterprise, University of Pretoria. All equipment Calibration Certificates are available on request.

Kutta Radio & charger Report Number: TRE0026-5/17 Page 9 of 27 7. MEASUREMENT OF UNCERTAINTY ISO / IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions results be included in the test report. The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor of k = 2) Measurement Uncertainty Test Item Frequency Uncertainty Conducted Emissions from the AC mains power ports 150kHz 30MHz ±3.40 Radiated emissions 30 1GHz ±5.16 Above 1GHz ±4.06 8. EQUIPMENT UNDER TEST 8.1 EUT IDENTIFICATION EUT name: Kutta Medium frequency radio Serial number: - Model number: DRUM 100 RCP 8.2 EUT TEST SETUP DETAIL: The specific test methodology will be discussed under each relevant test if different to the general set-up guidelines below. The EUT was switched on and operated in accordance with the manufacturer instructions. Tests were performed while the device was fully operational. A second Kutta radio was used to verify continuous operation and voice quality. The EUT was connected to a Drum rod antenna Deviations from the above set-up will be noted in each specific case.

Kutta Radio & charger Report Number: TRE0026-5/17 Page 10 of 27 8.3 SETUP IMAGES SANS / IEC 61000-4-2: ESD immunity test set-up SANS / IEC 61000-4-3: Radiated immunity test set-up SANS / IEC 61000-4-8: Power frequency magnetic immunity test set-up

Kutta Radio & charger Report Number: TRE0026-5/17 Page 11 of 27 9. EMISSIONS 9.1 RADIATED EMISSIONS: Method: Measurements were made in an 8-meter fully anechoic chamber that complies to CISPR 16. Preliminary (peak) measurements were performed at an antenna to EUT separation distance of 3 meters. The limit line was adjusted accordingly. The EUT was rotated 360 about its azimuth with the receive antenna located at a fixed height in horizontal and vertical polarities. Final measurements (quasi-peak) were then performed by rotating the EUT 360. All frequencies within 6 db of the limit were investigated in both horizontal and vertical antenna polarity, where applicable. 9.2 TEST SET-UP The EUT was switched on and operated in accordance with the manufacturer instructions. Automated scans in the frequency band 30MHz to 6000MHz (radiated emissions) were done in order to determine compliance emission results for the EUT. Table 9.2-1: Test equipment used for Radiated emission measurements EQUIPMENT SERIAL NUMBERS Agilent E7405AEMC Spectrum analyser MY45116923 Combilog Antenna AC-200 061128 AH Systems SAS-571 2455

Kutta Radio & charger Report Number: TRE0026-5/17 Page 12 of 27 9.3 RADIATED EMISSIONS RESULTS: RADIO 9.3.1 Radiated Emission: 30 MHz 1000MHz (Horizontal) Graph 1: Represents radiated emissions measured from the EUT. Peak results were below the required limit. 9.3.2 Radiated Emission: 30 MHz 1000MHz (Vertical) Graph 2: Represents radiated emissions measured from the EUT. Peak results were below the required limit. 9.3.3 Conclusion The EUT complies with the radiated emissions requirements of SANS 211 / CISPR 11

Kutta Radio & charger Report Number: TRE0026-5/17 Page 13 of 27 9.3.4 Radiated Emission: 1000MHz 6000MHz (Horizontal) Graph 3: Represents peak and average radiated emissions measured from the EUT. 9.3.5 Radiated Emission: 1000 MHz 6000 MHz (Vertical) Graph 4: Represents peak and average radiated emissions measured from the EUT. 9.3.6 Conclusion The EUT complies with the radiated emissions requirements of SANS 222 / CISPR 22 class A

Kutta Radio & charger Report Number: TRE0026-5/17 Page 14 of 27 9.4 RADIATED EMISSIONS RESULTS: CHARGER 9.4.1 Radiated Emission: 30 MHz 1000MHz (Horizontal) Graph 5: Represents radiated emissions measured from the EUT. Peak results were below the required limit. 9.4.2 Radiated Emission: 30 MHz 1000MHz (Vertical) Graph 6: Represents radiated emissions measured from the EUT. Peak results were below the required limit. 9.4.3 Conclusion The EUT complies with the radiated emissions requirements of SANS 211 / CISPR 11

Kutta Radio & charger Report Number: TRE0026-5/17 Page 15 of 27 9.4.4 Radiated Emission: 1000MHz 6000MHz (Horizontal) Graph 7: Represents peak and average radiated emissions measured from the EUT. 9.4.5 Radiated Emission: 1000 MHz 6000 MHz (Vertical) Graph 8: Represents peak and average radiated emissions measured from the EUT. 9.4.6 Conclusion The EUT complies with the radiated emissions requirements of SANS 222 / CISPR 22 class A

Kutta Radio & charger Report Number: TRE0026-5/17 Page 16 of 27 9.5 CONDUCTED EMISSIONS: CHARGER 9.5.1 TEST SET-UP The EUT was switched on and operated in accordance with the manufacturer instructions. Automated scans in the frequency band 150kHz to 30MHz were done in order to determine compliance emissions results for the EUT. Conducted emissions were tested while supplied with and AC/DC power supply Table 9.5-1: Test equipment used for Conducted emission measurements EQUIPMENT SERIAL NUMBERS Agilent E7405A EMC Spectrum analyser MY45116923 EMCO 3810/2 single phase LISN 00069452 Impulse limiter Agilent 100732 9.6 CONDUCTED EMISSIONS RESULTS 9.6.1 AC Input Live Graph CE1: Peak and average Conducted emissions measured on the Live lead of the EUT was below the Class B quasi peak and average limit.

Kutta Radio & charger Report Number: TRE0026-5/17 Page 17 of 27 9.6.2 AC Input Neutral Graph CE2: Quasi peak and average Conducted emissions measured on the Neutral lead of the EUT was below the Class B quasi peak and average limit. 9.6.3 Conclusion The EUT complies with the conducted emissions requirements of SANS 211 / CISPR 11.

Kutta Radio & charger Report Number: TRE0026-5/17 Page 18 of 27 9.7 SANS / IEC 61000-3-3 VOLTAGE FLUCTUATIONS & FLICKER Method: The test circuit consists of a test supply voltage, reference impedance, the equipment under test and a flicker meter compliant with IEC-60868. The equipment was tested in the condition in which the manufacturer supplied it. Table 9.7-1 Test equipment used for Voltage Fluctuations & Flicker test results EQUIPMENT SERIAL NUMBERS California Instruments Model 4503L AC Power system HK50775 Thurlby Thandar HA1600A Power & harmonics analyzer 479560 9.8 TEST SET-UP The EUT was switched on and operated in accordance with the manufacturer instructions. The EUT was observed for 12 integration periods (2 hours) while operating continuously. One power cycle was performed. The unit complied with the Pst and Plt requirements. 9.8.1 Results 1. dmax 0.25% 2. pmax 6 watts 3. Power factor 0.497 9.8.2 Conclusion The EUT complies with the voltage fluctuations and flicker requirements of SANS / IEC 61000-3-3

Kutta Radio & charger Report Number: TRE0026-5/17 Page 19 of 27 10. IMMUNITY 10.1 SANS / IEC 61000-4-2 ESD IMMUNITY Method: The test is intended to demonstrate the immunity of equipment subjected to static electricity discharges from operators directly and to adjacent objects. The table top equipment under test is placed on a wooden table, 0.8 m high, standing on the ground reference plane. A horizontal coupling plane (HCP), 1.6 x 0.8 m, is placed on the table. The EUT and the cables are isolated from the coupling plane by an insulating support 0.5 mm thick. The floor standing equipment is isolated from the ground reference plane by an insulating support about 0.1 m thick. The vertical coupling plane (VCP) of dimensions 0.5 m x 0.5 m is placed parallel to, and positioned at a distance of 0.1 m from, the EUT. Table 10.1-1 Test equipment used for ESD EQUIPMENT SERIAL NUMBER TESEQ NSG 3040 6074 TESEQ NSG 435 ESD gun 7184 Contact discharge tip None Vertical Coupling Plane None Air discharge tip None 10.1.1 Set-up The EUT was switched on and operated in accordance with the manufacturer instructions. The EUT was tested as tabletop equipment. 10 positive and 10 negative contact discharges were applied to the VCP and HCP respectively. 10 positive and 10 negative air discharges were made to the following points on the EUT. 10.1.2 Results Table 10.1-2 Results of ESD Contact discharge POSITION ON EUT VOLTAGE NUMBER OF DISCHARGES RESULT VERDICT HCP (Horizontal) 8kV 10 Not Susceptible Comply (A) VCP (Vertical) 8kV 10 Not Susceptible Comply (A) Radio C1 C4 8kV 10 Not Susceptible Comply (A) Charger C1 C4 8kV 10 Not Susceptible Comply (A)

Kutta Radio & charger Report Number: TRE0026-5/17 Page 20 of 27 Table 10.1-3 Results of ESD Air discharge POSITION ON EUT VOLTAGE NUMBER OF DISCHARGES RESULT VERDICT Radio A1 A5 15kV 10 Not Susceptible Comply (A) Charger A1 A6 15kV 10 Not Susceptible Comply (A) 10.1.3 Conclusion The EUT complies with criterion A of SANS / IEC 61000-4-2 Criterion A: normal performance within limits specified by the manufacturer, requestor or purchaser 10.2 SANS / IEC 61000-4-3 RADIATED IMMUNITY Method: The test allows estimating of the radiated immunity of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 80MHz to 6000MHz. The interference is applied on the enclosure of the equipment by using transmitting antennas. Table 10.2-1 Test equipment used for Radiated Immunity. EQUIPMENT SERIAL NUMBER ASUS Laptop with AR EMCWare software X541NA-GQ279T Agilant 83620B Signal Generator 98091 Combilog Antenna AC-200 061128 AH Systems SAS-571 2455 Narda EP-600 Electric Field probe 611WX70397 10.2.1 Set-up The EUT was switched on and operated in accordance with the manufacturer instructions. The test was performed in a full anechoic chamber in the frequency band 80 MHz to 6000 MHz with 80 % AM 1kHz, at a level of 3 and 10 V/m (un-modulated) according to SANS / IEC 61000-4-3 Clause 8 (Frequency step and dwell method). The antenna was positioned at a distance of 3 meters from the EUT. The EUT was tested in both Horizontal and Vertical polarizations.

Kutta Radio & charger Report Number: TRE0026-5/17 Page 21 of 27 10.2.2 Results Frequency Band Field level Modulation Result 80 1000MHz 10V/m 1kHz 80% AM No effect 1 6GHz 3V/m 1kHz 80% AM No effect 10.2.3 Conclusion The EUT complies with criterion A of SANS / IEC 61000-4-3 Criterion A: normal performance within limits specified by the manufacturer, requestor or purchaser 10.3 SANS / IEC 61000-4-4 FAST TRANSIENT IMMUNITY Method: Measurements were made on a ground plane that extends 1-meter minimum beyond all sides of the system under test. Mains power tests were conducted with the product connected to a Coupling/Decoupling Network (CDN). I/O lines were tested in a Capacitive Coupling Clamp. One of each unique interface was tested for a period of one (1) minute per polarity. Table 10.3-1 Test equipment used for Electrical Fast Transients EQUIPMENT SERIAL NUMBER TESEQ NSG 3040 6074 TESEQ CDN 3425 Capacitive clamp 3082 10.3.1 Set-up and levels The EUT was supplied with the required voltage and subjected to a direct injected 5 khz repetition rate 5/50nS wave interference signal. The charger was tested as table top equipment. AC Power Port Injection Method Voltage Repetition rate Result Live to Neutral +4kV 5kHz No Effect -4kV 5kHz No Effect Live and Neutral to Ground reference +4kV 5kHz No Effect -4kV 5kHz No Effect 10.3.2 Conclusion: The EUT was resilient to the applied fast transients The EUT complies with criterion A of SANS / IEC 61000-4-4 Criterion A: normal performance within limits specified by the manufacturer, requestor or purchaser

Kutta Radio & charger Report Number: TRE0026-5/17 Page 22 of 27 10.4 SANS / IEC 61000-4-5 SURGES Method: Mains power tests were conducted with the product connected to a Coupling/ Decoupling Network (CDN). The test voltage was increased from the lowest indicated level up to the maximum level. Five (5) positive surges and five (5) negative surges were applied at each of phases of the AC waveform: 0, 90, 180 and 270. Each surge was applied 60 seconds after the previous surge. Where applicable signal and telecommunications ports were subject to five (5) positive and five (negative) surges applied through the appropriate Coupling/Decoupling Network (CDN). Table 10.4-1 Test equipment used for Surges EQUIPMENT SERIAL NUMBER TESEQ NSG 3040 6074 10.4.1 Set-up and Test Levels The EUT was supplied with the required voltage. The pulses were applied in the following sequence: AC Power Port Injection Method Voltage Phase Result +2kV 0, 90, 180 and 270 No Effect Live to Neutral -2kV 0, 90, 180 and 270 No Effect 10.4.2 Conclusion The EUT was resilient to the surges applied The EUT complies with Criterion A of SANS / IEC 61000-4-5 Criterion A: normal performance within limits specified by the manufacturer, requestor or purchaser

Kutta Radio & charger Report Number: TRE0026-5/17 Page 23 of 27 10.5 SANS / IEC 61000-4-6 CONDUCTED IMMUNITY Method: Measurements were made on a ground plane that extends at least 0.5-meter minimum beyond all sides of the system under test. The EUT was located 10cm above the reference ground plane and any associated I/O cables attached to the EUT were located between 30mm and 50mm above the ground plane. The indicated field was pre-calibrated prior to placement of the system under test. Table 10.5-1 Test equipment used for Conducted Immunity. EQUIPMENT SERIAL NUMBER Agilant 83620B Signal Generator 98091 RF Current Injection Probe 561383 Kalmus 757LC 75Watt Amplifier 561383 M2 & M3 CDN-M325E 521169 Telecommunications CDN-T8SE 511434 10.5.1 Set-up and Test Levels The EUT was switched on and operated in accordance with the manufacturer instructions. The test was performed in the isert laboratory in the frequency band 150kHz to 80 MHz with 80 % AM 1kHz, at a level of 10 V (un-modulated) on the input of the Kutta charger and Rod antenna cable according to SANS / IEC 61000-4-6. 10.5.2 Results Line Injection method Voltage Modulation Frequency Band Result AC / DC power input CDN (M2) 10Vrms 1kHz, 80% AM 150kHz to 80MHz No effect Drum Rod antenna cable BCI clamp 10Vrms 1kHz, 80% AM 150kHz to 80MHz No effect 10.5.3 Conclusion The EUT complies with criterion A of the relevant section of SANS / IEC 61000-4-6 Criterion A: normal performance within limits specified by the manufacturer, requestor or purchaser)

Kutta Radio & charger Report Number: TRE0026-5/17 Page 24 of 27 10.6 SANS / IEC 61000-4-8 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST Method: Measurements were made on a ground plane that extends 1-meter minimum beyond sides of the system under test. Table top EUT is located 80cm above the reference and floor-standing EUT is located 10cm above the reference ground plane. The indicated field was pre-calibrated prior to placement of the EUT under test. Table 10.6-1 Test equipment used for Power frequency magnetic Immunity. EQUIPMENT SERIAL NUMBER Variac Yokoyama Electric Works 3772 Step down transformer None Fluke 115 Multimeter 72081177 RS Clamp Meter None AC Helmholtz Coil isert001 10.6.1 Set-up The EUT was switched on and operated in accordance with the manufacturer instructions. The test was performed with a single Helmholtz Coil, at a level of 30 A/m according to SANS / IEC 61000-4-8. 10.6.2 Results Axes Field Strength (A/m) Frequency (Hz) Result X-Axis 30 50 No effect Y-Axis 30 50 No effect Z-Axis 30 50 No effect 10.6.3 Conclusion The EUT was resilient to the 50 Hz signal applied at a level of 3 A/m. Criterion A: normal performance within limits specified by the manufacturer, requestor or purchaser

Kutta Radio & charger Report Number: TRE0026-5/17 Page 25 of 27 10.7 SANS / IEC 61000-4-9 PULSE MAGNETIC FIELD IMMUNITY TEST Method: Measurements were made on a ground plane that extends 1-meter minimum beyond sides of the system under test. Table top EUT is located 80cm above the reference and floor-standing EUT is located 10cm above the reference ground plane. The indicated field was pre-calibrated prior to placement of the EUT under test. Table 10.7-1 Test equipment used for Pulse magnetic field Immunity. EQUIPMENT SERIAL NUMBER TESEQ NSG 3040 6074 TESEQ INA 752 - AC Helmholtz Coil isert001 10.7.1 Set-up 10.7.2 Results The EUT was switched on and operated in accordance with the manufacturer instructions. The test was performed with a single Helmholtz Coil, at a level of 300 A/m according to SANS / IEC 61000-4-9. Axes Field Strength (A/m) Result X-Axis 300 No effect Y-Axis 300 No effect Z-Axis 300 No effect 10.7.3 Conclusion The EUT was resilient to the applied pulses at 300A/m Criterion A: normal performance within limits specified by the manufacturer, requestor or purchaser)

Kutta Radio & charger Report Number: TRE0026-5/17 Page 26 of 27 10.8 SANS / IEC 61000-4-11 VOLTAGE DIPS AND INTERRUPTIONS Method: The product was subjected to voltage dips and interruptions. Testing was performed with the product connected directly to a generator capable of simulating the voltage drops and interrupts as described. Table 10.8-1 Test equipment used for Voltage Dips and Interruptions EQUIPMENT SERIAL NUMBER TESEQ NSG 3040 6074 10.8.1 Set-up and Test Levels The EUT was switched on and operated in accordance with the manufacturer instructions. The EUT was subjected to the following voltage dips and interruptions applied to the AC power port of the EUT: Test Level (% Ut) Test Duration (cycles) Result 100 0.5 No effect 40 10 No effect 70 25 No effect 100 250 * Note 1 10.8.2 Results 10.8.3 Conclusion Note 1: The EUT stopped to charge during application of the 100% reduction for 250 cycles. The EUT resumed its charging operation after application of the supply reduction. The EUT complies with Criterion B of the relevant sections of SANS / IEC 61000-4-11 Criterion B: Temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment under test recovers its normal performance, without operator intervention

Kutta Radio & charger Report Number: TRE0026-5/17 Page 27 of 27 11. CONCLUSION The Kutta Medium frequency radio & charger (In the configuration tested), meets the requirements of the following standards: DMR requirements for safety critical equipment as listed in Government Gazette 32885 of January 22, 2010 ETSI EN 301 489-1 V2.1.1 (2017-02) Electromagnetic compatibility and Radio Spectrum Matters (ERM) SANS 211 (2011) / CISPR 11 (2010 +A1:2010): Industrial, scientific and Medical (ISM) radiofrequency equipment - Electromagnetic disturbance characteristics - Limits and methods of measurement SANS 222 (2009) / CISPR 22 (2008): Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement SANS 61000-3-3 (2009) / IEC 61000-3-3 (2008): Limits Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems Equipment with rated current 16 A per phase SANS 61000-4-2 (2009) / IEC 61000-4-2 (2008): Testing and measurement techniques Electrostatic discharge immunity test SANS 61000-4-3 (2008) / IEC 61000-4-3 (2010): Testing and measurement techniques Radiated, radio-frequency, electromagnetic field immunity test SANS 61000-4-4 (2011) / IEC 61000-4-4 (2011): Testing and measurement techniques Electrical Fast Transient / Burst SANS 61000-4-5 (2006) / IEC 61000-4-5 (2005): Testing and measurement techniques Surge immunity test SANS 61000-4-6 (2009) / IEC 61000-4-6 (2008): Testing and measurement techniques Immunity to conducted disturbances, induced by radio-frequency fields SANS 61000-4-8 (2009) / IEC 61000-4-8 (2009): Testing and measurement techniques- Power Frequency Electric Field Immunity Test SANS 61000-4-11 (2005) / IEC 61000-4-11(2004): Testing and measurement techniques Voltage Dips, Short Interruptions and voltage variations immunity test. 11.1 COMPLIANCE STATEMENT The EUT complies with the requirements of the specifications listed in 11 above.