Introduction. Centrado leading-edge transformer. Introduction

Similar documents
SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

OIL-IMMERSED ARC-SUPPRESSION COILS

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Basic Principles and Operation of Transformer

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Powering Your Business

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

Liquid-Filled Transformers

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Distribution and Power Transformers

POWER TRANSFORMERS CATALOGUE

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

DISTRIBUTION TRANSFORMERS

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

CAST RESIN DRY TRANSFORMER

Commissioning Manual Distribution Transformers - Three-phase Oil Filled

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

Dry-type Transformer. High Reliability Maintenance-free Environmentally Friendly

Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

K Factor Power Transformers

Power Transformers Basics

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

TMC Transformers TMC

DISTRIBUTION TRANSFORMER 11 / kv

General Electricity Company of Libya

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

POWER/DISTRIBUTION TRANSFORMER PERFORMANCE EVALUATION.

SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION THE ELECTRICITY (PEDE) SPECIFICATIONS FOR

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

On-Load Tap Changer Type M

ISSN: [IDSTM-18] Impact Factor: 5.164

Electrical Description

Line Frequency Transformer

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

HOW TO SAFE GUARD THE TRANSFORMER..???

Cast resin transformers HARMONY TM

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

Hands-On Transformer Testing and Maintenance

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

User s Manual For CT Model IMB

nical catalogue Tech

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

TIGHTENING TORQUE ON WOODEN CORE CLAMP (Nm) (STEEL FASTENER) 1 M M M M M

ECP COMPACT AND MICRO SUBSTATION COMMISSIONING PROCEDURE

SECTION TRANSFORMERS

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Oil-immersed Transformers

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

About us. Vision. To lead our field in innovation, quality and customer service.

7. INSPECTION AND TEST PROCEDURES

PPC TECHNICAL SPECIFICATION D/ NCMD / THREE-PHASE DISTRIBUTION TRANSFORMERS

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

(

Mechanical Design. Brian Brinson Mechanical Design Manager.

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Distribution Transformers

SHUNT REACTOR CORES Up to 765 kv MVAR

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

ON LOAD TAP CHANGERS RSV 5.3 TECHNICAL DATA

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

TRAFO ELECTRIC P. LTD.

Isolation Transformer Series

PRODUCTS & ACCESSORIES FOR DISTRIBUTION TRANSFORMERS.

TECHNICAL DESCRIPTION ND-387. THREE-PHASE TRANSFORMERS, 150 / 21kV, 40/50MVA AND 20/25 MVA, Dyn1

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

GREEN TRAFO PRODUCTS SHR - THREE-PHASE SHUNT REACTOR

Basic principles and operation of a transformer

EARTHING TRANSFORMER

MESP TECHNICAL SPECIFICATION FOR A 1500V DC RECTIFIER TRANSFORMER

THREE-PHASE DISTRIBUTION TRANSFORMERS

ON LOAD TAP CHANGERS RS 6.3 / RS 6 TECHNICAL DATA

DESIGNED MANUFACTURED TESTED

Transcription:

Introduction Centrado leading-edge transformer products are designed to optimize safety and produced to deliver a great electrical power experience and solution - for factory, infrastructure, home industry, business and home electricity Centrado transformers are produce with the most current machine and adopting advanced technologies to meet a high quality transformer All of the Centrado product ranges are produced using high quality cooper with enamel isolated to deliver a great performance, reliability, durability and conformance to the user Introduction http://wwwsentrapowercom

Production range DISTRIBUTION TRANSFORMER Capacity 25 KVA up to 10000 KVA Phase 3 Ph / 1 Ph Primary 20 KV Secondary 400 V Type ONAN AUTO TRANSFORMER Capacity 1 KVA up to 1000 KVA Phase 3 Ph / 1 Ph Primary 400/231 380/220 220/127 200/115 V Secondary 200/115 220/127 380/220 400/231 V Type Dry / Oil ISOLATION TRANSFORMER Capacity 1 KVA up to 1000 KVA Phase 3 Ph / 1 Ph Primary 400/231 380/220 220/127 200/115 V Secondary 200/115 220/127 380/220 400/231 V Type Dry / Oil Production Range http://wwwsentrapowercom

Production range RECTIFIER TRANSFORMER Capacity 500 Amp up to 10000 Amp Primary 220 / 380 V Secondary 0 6V 12V 20V 24V (DC) Cooling system Fan / oil STARTING TRANSFORMER Capacity 3 HP up to 1500 HP Primary 220-380 V Secondary 0% 50% - 65% - 80% - 100% Production Range http://wwwsentrapowercom

Voltage Centrado transformers are being adjusted to distributed voltage in Indonesia from 3 KV, 6 KV, 7 KV, 12 KV, 20 KV, 24 KV The tap changer are at 2,5%, 5% and 10% are operated outside tank at unloaded condition Centrado distribution transformer offers wide capacity range from 25 KVA up to 12500 KVA At low voltage with unloaded condition, centrado transformer are produced at 133V/231V (B1) and 231V/400V (B2) or can be combined with simultaneous running with nominal 75% loaded voltage on B1 and 100% on B2 Centrado transformer can handle dielectric test at high voltage (50Hz) and the impulse voltage are according to IEC standard by using magnetic core that made from grain oriented silicon steel with V shape designed to decrease iron losses, copper losses and operation noise that also reduce the size of transformer Centrado transformer can hold on short circuit and well tested with routine test, induced test, standard IEC test and quality control that give centrado transformer a new certification in ISO 9001 : 2001 Vector Group Centrado transformer are generally designed with two type of Vector such as : 25 KVA - 160 KVA : Yzn 200 KVA - 10,000 KVA : Dyn Voltage & Vector Group http://wwwsentrapowercom

Terminal Construction Coil at middle voltage are using great quality copper with enamel isolated and for the low voltage are using great quality copper foil Middle Voltage tap are using elastimould synthetic resin or porcelain bushing and for the low voltage tap are using porcelain bushing or mould cooper Distribution Transformer Accessories Included accessories High tension porcelain bushing Low tension porcelain bushing Manual of load tap changer Thermometer pocket Radiator Oil level indicator Pressure valve Drain valve Safety valve Conservator Earth terminal Rollers Hanger lugs Optional accessories RIS / DMCR Dial thermometer Elastimold Cable Box Pressure Relief Valve Pressure Vacuum Gauge Nitrogen Filling Valve Terminal Construction http://wwwsentrapowercom

Ratio test Insulation test Iron loses test Copper loses test Impedance test Resistance winding machine Dielectric test 60 KV Over voltage test 350 Hz Routine test Warranty The Centrado transformer purchased is covered by a limited warranty program for a period of a 1 year, validity starting from the date of purchase Our Additional Service Purifying Oil transfo Repair transformer Commisioning service Electrical installation Customer Support PT Sentra Power Nusantara provides an extra element of peace of mind to reliable products and service with its comprehensive customer support operation Knowledgeable support staffs are available to resolve the rare technical support issue Corporate address PT Sentra Power Nusantara Sales Operation of Centrado Transformer Office : Komplek Ruko Green Ville Blok AW No20 Jakarta Barat - 11510 - Indonesia Phone : (+6221) 5698 1101 Fax : (+6221) 5698 1102 Email Website : sales@sentrapowercom Factory : Jl Narogong Raya Km11 Bekasi - Indonesia : http://wwwsentrapowercom Warranty & Our Additional Service http://wwwsentrapowercom