Operating Manual MU2000K

Similar documents
Operating Manual NS20K

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

27/04/2015

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

Coupling Relays and Converters

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Power supply CP-D 24/4.2 Primary switch mode power supply

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Pt 100-Temperature-Relay TR 111 V

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-D 12/2.1

Thermocouple - Transducer

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-T 48/20.0 Primary switch mode power supply

MINI-PS AC/24DC/1.3

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

JUMO Wtrans Receiver with Wireless Data Transmission

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages


Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Power supply CP-D 24/1.3

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Moeller Electric Corporation

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Power supply CP-T 24/10.0 Primary switch mode power supply

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

Type Nominal voltage (V) Code HSV V

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

Three-phase monitoring relays CM-PFE and CM-PFE.2

SEPARATOR P20G TYPE USER S MANUAL

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

DM-45 Digital Multimeter

CM-IWM.11 Insulation monitoring relay

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

CP-E range Benefits and advantages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

Type CP-S, CP-C & CP-A Switch mode

Three-phase monitoring relay CM-PVE

AC 01.2 HART Technical data Actuator controls

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

ISOMETER iso685- -B. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

MACX MCR-UI-UI-UP(-SP)(-NC)

DIGITAL PANEL METER N24 AND N25 METER SERIES

ISOMETER iso685- Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

AC 01.2 Modbus TCP/IP

N24, N25 DIGITAL PANEL METER

New Products Catalogue 2009 Safety Relays ESR5

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Primary switch mode power supplies Product group picture

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Electronic timer CT-TGD.22

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Power supply CP-E 24/0.75

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Power supply CP-E 24/2.5

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic relays. Monitoring. Monitoring

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

It s TRUE! True RMS measurement with the new AC/DC high-voltage transmitters of the VariTrans P TRMS series. Isolation Amplifiers.

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

Model Number Structure

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Electronic timer CT-SDD.22

Industrial motor controller for brushed DC motors 24 VDC

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

RMA42. Technical Information

Industrial motor controller for brushed DC motors 12 VDC

Industrial motor controller for brushed DC motors 24 VDC

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

PHOENIX CONTACT

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Transcription:

ZIEHL industrie elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching Relays and Controls Measuring Transducers Grid- and Plant Protection Operating Manual MU2000K - Universal Measuring Transducer for Voltage and Current (AC and DC) updated: 2018-03-22 /Sc MU2000K 12600-0703-04 Page 1 / 13 www.ziehl.de

Table of contents 1 Display and controls... 3 2 Factory setting... 3 3 Application and short description... 3 4 Overview of functions... 3 5 Connecting diagram... 4 6 Important Information... 4 7 Installation... 5 8 Commissioning... 5 8.1 Overview of commissioning... 5 8.2 Overview of the predefined standard ranges... 5 8.3 Setting a predefined range... 6 8.4 Diagram for setting a predefined range... 7 8.5 Overview of scaling an arbitrary range... 8 8.6 Scaling of range... 8 8.7 Diagram for scaling of range... 9 8.8 System measurement time... 9 8.9 Setting the System measurement time... 10 8.10 Checking of parameters... 11 9 Error search... 11 10 Technical data... 12 11 Housing Type K... 13 MU2000K 12600-0703-04 Page 2 / 13 www.ziehl.de

1 Display and controls - Set Button to navigate in menu - Down Button to change Parameters - LED Power Device active - LED I Current input active - LED U Voltage input active - LED AC Alternate Current / Voltage measuring active 2 Factory setting Default settings: Input: AC 5 A (AC 0 5 A) Output: DC 0 10 V, 0 20 ma Measuring time: 160 ms (8 measurements, x 20 ms measurement time) 3 Application and short description Measuring transducers MU2000K can measure DC- an AC-voltages up to 600 V and DC- and AC-currents 0-1/5 A. Preset measuring ranges can be selected. More measuring ranges (zero and full-scale) can be easily scaled. The output signals DC 0/2-10 V and 0/4-20 ma are insulated from measuring input and supply voltage. With its universal supply voltage AC/DC 24-240 V the measuring transducer can be connected to all common supply voltages. The MU2000K e.g. is suitable for measuring DC voltages and charging currents at batteries or for measuring AC voltages and currents in plants for own generation of energy. 4 Overview of functions Output signal 0-20mA and 0-10V or 4-20mA and 2-10V Rated Supply Voltage AC/DC 24-240V Insulation between inputs, outputs and supply voltage Inputs: AC/DC 0 600 V (Preset values: 0 30 V / 80 120 V / 0 150 V / 0 300 V / 0 600 V) AC/DC 0 5 A (Preset values: 0 1 A / 0 5 A) In measuring ranges for AC also DC-signals can be measured. Negative signals will be measured as positive signals. Zeros and Full Scales for more measuring-ranges can be freely selected by the user. MU2000K 12600-0703-04 Page 3 / 13 www.ziehl.de

5 Connecting diagram 6 Important Information The measuring input fulfils reinforced insulation according to DIN EN 61010-1 for overvoltage category II and pollution degree 2. Connected voltages may not exceed 300 V AC/DC to earth. DANGER! Hazardous voltage! Will cause death or serious injury. Turn off and lock out all power supplying this device before working on this device. To use the equipment flawless and safe, transport and store properly, install and start professionally and operate as directed. Only let persons work with the equipment who are familiar with installation, start and use and who have appropriate qualification corresponding to their function. They must observe the contents of the instructions manual, the information which are written on the equipment and the relevant security instructions for the setting up and the use of electrical units. The equipment are built according to DIN / EN and checked and leave the plant according to security in perfect condition. If, in any case the information in the instructions manual is not sufficient, please contact our company or the responsible representative. Instead of the industrial norms and regulations written in this instructions manual valid for Europe, you must observe out of their geographical scope the valid and relevant regulations of the corresponding country. Observe the maximum temperature permissible when installing in switching cabinet. Make sure sufficient space to other equipment or heat sources. If the cooling becomes more difficult e.g. through close proximity of apparatus with elevated surface temperature or hindrance of the cooling air, the tolerable environmental temperature is diminishing. MU2000K 12600-0703-04 Page 4 / 13 www.ziehl.de

Attention! Universal power supply The device has a universal power supply, that is suitable for DC- and AC voltages. Before connecting the device to supply-voltage make sure that the connected voltage corresponds with the voltage on the lateral type on the device. 7 Installation The unit can be installed as follows: Installation in switchgear cabinet on 35 mm mounting rail according to EN 60715 With screws M4 for installation on walls or panel. (additional latch is not included in delivery) Connection according to connection plan or type plate. 8 Commissioning 8.1 Overview of commissioning The MU2000K can be commissioned to predefined standard ranges or scaled to an arbitrary range. There are two different ways to do the settings: MU2000K setting a predefined range MU2000K scaling an arbitrary range 8.2 Overview of the predefined standard ranges Following standard ranges can be set without adjustment to the unit: Input voltage (AC / DC) Input current (AC / DC) Zero point Full scale Zero point Full scale Output 0 V 30 V 0 A 1 A 0-10 V / 0-20 ma 80 V 120 V 0 A 5 A or 0 V 150 V 2-10 V / 4-20 ma 0 V 300 V 0 V 600 V MU2000K 12600-0703-04 Page 5 / 13 www.ziehl.de

8.3 Setting a predefined range Power off the device Press Button [Set] and keep pressed Power on the device, and keep pressed the button [Set] After 5s flashes the green LED, release button [Set] Parameterization input type LED ON flashes 1x Select with button [Set] the input type displayed by LED U (DC voltage), LED AC + U (AC voltage), LED I (DC current), LED AC + I (AC current) Press button [Down] Parameterization range >> LED ON flashes 2x Select with button [Set] the range of the input Press button [Down] Number LED of flashes U AC + U I AC + I 1 x DC 0 30 V AC 0 30 V DC 0...1 A AC 0...1 A 2 x DC 80 120 V AC80 120 V DC 0...5 A AC 0...5 A 3 x DC 0 150 V AC 0 150 V 4 x DC 0 300 V AC 0 300 V 5 x DC 0 600 V AC 0 600 V Parameterization output LED Power flashes 4x Select with button [Set] the output range Number LED Of flashes U + I 1 x 0-10 V / 0-20 ma 2 x 2-10 V / 4-20 ma Press button [Down] End of parameterization, LED ON lights permanently Attention: When no button is pressed during scaling for 120 s, the process is cancelled automatically. Entered values will be discarded. When scaling is started, all parameters are reset to default. In normal operating mode the selected input is displayed with LED. MU2000K 12600-0703-04 Page 6 / 13 www.ziehl.de

8.4 Diagram for setting a predefined range Mode Normal state MU2000K 12600-0703-04 Page 7 / 13 www.ziehl.de

8.5 Overview of scaling an arbitrary range Other ranges may be set by scaling of the input signal: Range Output Input Zero point Full scale U (AC / DC) 0 600 V 0 600 V 0-10 V / 0-20 ma I (AC / DC) 0 5 A 0 5 A or 2-10 V / 4-20 ma 8.6 Scaling of range Power off the device Press Button [Down] and keep pressed Power on the device, and keep pressed the button [Down] After 5s flashes the green LED, release button [Down] Parameterization input type LED ON flashes 1x Select with button [Set] the input type displayed by LED U (DC voltage), LED AC + U (AC voltage), LED I (DC current), LED AC + I (AC current) Press button [Down] Parameterization input zero point LED ON flashes 2x Connect a signal at the input corresponding to the zero point Press button [Down] (store of value, green LED flashes 3 times quickly) Parameterization input full scale LED ON flashes 3x Connect a signal at the input corresponding to the full scale Press button [Down] (store of value, green LED flashes 3 times quickly) Parameterization output LED ON flashes 4x Select with button [Set] the output range o LEDs (U + I) 1 x flash -> output 0-10 V / 0-20 ma o LEDs (U + I) 2 x flash -> output 2-10 V / 4-20 ma Press button [Down] End of parameterization, LED ON lights permanently Attention: When no button is pressed during scaling for 120 s, the process is cancelled automatically. Entered values will be discarded. When scaling is started, all parameters are reset to default. In normal operating mode the selected input is displayed with LED. MU2000K 12600-0703-04 Page 8 / 13 www.ziehl.de

8.7 Diagram for scaling of range Mode Normal state Signal input = zero point Signal Input = full scale 8.8 System measurement time Measuring time for one measurement is 20 ms (at AC 60 Hz app. 17 ms). System measuring time is calculated by measuring time multiplied with number of measurements. Generation of measured value: new measurement measurement measurement... measurement Measured value = average of measurements oldest measurement Is deleted Measuring ranges AC: when measuring DC measuring time prolonged to 25 ms MU2000K 12600-0703-04 Page 9 / 13 www.ziehl.de

8.9 Setting the System measurement time Power off the device Keep pressed buttons [Set] and [Down] simultaneously Switch on power supply while buttons are pressed Release buttons after app. 5s when green LED starts blinking Parameterization System measurement time LED ON flashes 5x Select with button [Set] the System measurement time Number LEDs of flashes AC + U + I 1 x 20 ms (60Hz = 17 ms) 2 x 40 ms (60Hz = 33 ms) 3 x 80 ms (60Hz = 67 ms) 4 x 160 ms (60Hz = 133 ms) 5 x 320 ms (60Hz = 267 ms) 6 x 640 ms (60Hz = 533 ms) Press button [Down] End of parameterization, LED ON lights permanently MU2000K 12600-0703-04 Page 10 / 13 www.ziehl.de

8.10 Checking of parameters During operation, several parameters can be checked. Keep button [Down] pressed (5s) until green LED Power starts blinking (1x) Exit with pressing button [Down] again, Automatic exit 30s after last actuation of a button Display of selected parameter with blinking yellow LEDs. Shift with button [Set] to next parameters (green LED Power blinks accordingly) Mode Normal state 9 Error search Wrong output signal (current/voltage) OUT (terminal 1 2 3) Cause Remedy The device is not configured correctly Check commissioning 22mA at output 0/4 20 ma, 11V at output 0/2 10 V (LED Power flashes quickly) Cause Remedy Internal error of device Reset by interrupting supply voltage. If the error cannot be patched by a Reset send back to factory for repair. MU2000K 12600-0703-04 Page 11 / 13 www.ziehl.de

10 Technical data Rated supply voltage Us AC/DC 24 240 V 0/50 400 Hz < 3 W < 8 VA Tolerance DC 20,4-297 V AC 20-264 V Inputs / Ranges Inputresistance Maximum Input signal Error of full scale DC 30 V, 150 V, 300 V, 600 V 0,2 % > 500 kω 600 V AC 30 V, 150 V, 300 V, 600 V 0,5 % DC 1 A, 5 A 7,5 A / 4s, 0,1 % 30 mω AC 1 A, 5 A 25 A / 1s 0,5 % AC- and DC measuring possible without switching over (AC ranges only, see item 8.8) Frequency at AC- measurements 45 420 Hz measurement deviation at > 100 Hz 1% of full scale measurement deviation at > 300 Hz 2% of full scale Temperature factor < 0,02 % / K Resolution 14 Bit Output Voltage output Tolerance / Temperature factor Resolution 11,6 Bit < 3,1 mv Load 1 k Ω 2 outputs with common ground DC 0 10 V (0 10,25 V, 11 V at device error) DC 2 10 V (1,9 10,25 V, 11 V at device error) 0,3 % of full scale (from 0,1 V) / < 0,01 % / K Current output DC 0 20 ma (0 20,5 ma, 22 ma at device error) DC 4 20 ma (3,8 20,5 ma, 22 at device error) Tolerance / Temperature factor 0,3 % of full scale (from 0,1 ma) / < 0,015 % / K Resolution 11,6 Bit < 6,1 µa Load 500 Ω Error from load (250 Ω Load) / 250 Ω * 0,3 % of current Measuring principle Measuring time Averaging System measurement time Reaction time of the outputs RMS (AC), mean (DC) 20 ms (17 ms at 60 Hz) adjustable 1, 2, 4, 8, 16, 32 measurements Measuring time * Averaging < 45ms + System measurement time Test conditions EN 61010-1 Rated supply voltage Us (terminals A1, A2) Pollution degree 2 Overvoltage category III reinforced insulation Rated insulation voltage Ui 300V Input (terminals 4,5,6,7) Pollution degree 2 Overvoltage category II reinforced insulation Rated insulation voltage Ui 300 V Galvanic insulation / Test-voltage Input output DC 3820 V Us output DC 5250 V Us input DC 5250 V MU2000K 12600-0703-04 Page 12 / 13 www.ziehl.de

1945 1960 75,0 19,8 35,4 19,8 1945 1960 1045 1940 82,5 EMC immunity EN 61326-1 Industrial electromagnetic environment EMC emission EN 61000-6-3 Environmental conditions rated ambient temperature range -20 C... +50 C storage temperature -20 C... +70 C Admissible temperature for wiring -5 C... +70 C Altitude Climatic conditions Vibration resistance EN 60068-2-6 < 2000 m above sea level (MSL) 5-85% rel. humidity, no condensation 2 13,2 Hz ±1 mm 13,2... 100 Hz 1 g Housing Type K Dimension (H x W x D) 75 x 22,5 x 110 mm Line connection solid wire each 1 x 0,5 2,5 mm 2 Stranded wire with insulated ferrules each 1 x 0,14 1,5 mm 2 Torque 0.5 Nm (3,6 lb.in) Protection class housing IP 40 Protection class terminals IP 20 Mounting Snap mounting on 35 mm standard rail EN 60 715 or M4 screws Weight app. 100 g Subject to technical changes 11 Housing Type K Dimensions in mm 3 2 1 3.2 22,5 5,0 110,0 4 5 100,5 1 lower part 2 upper part 3 bar 4 screw 5 holes for screw-mount 4,2 3.1 MU2000K 12600-0703-04 Page 13 / 13 www.ziehl.de