MediMode Multi-Function Recessed Patient Room Light

Similar documents
WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

General Installation Instructions

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

Ambient Indoor.

SAVE THESE INSTALLATION INSTRUCTIONS

HO4 Surface Mount Installation Instructions Overview

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

5 ACCESS PANEL INSTALLATION SPACER *SLIDE TO LOCATION OF FASTENER DURING INSTALLATION OF EACH FASTENER

TrendWall Floor-To-Ceiling Panels Installation Instruction

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

======================================================================================== ( DR / DR) JK WRANGLER MOD RACK

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

INDIVIDUAL MOUNTING: T-Bar

Assembly Instructions for model: VMPR1

Lightplane 3.5 Recessed

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

GE Monogram. Installation. Instructions. Microwave Oven. Under Cabinet Installation. and. JX827 Series Built-In Kit. Models.

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

IMPORTANT SAFETY INSTRUCTIONS:

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Installation Instructions For Reveal

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

Assembly Instructions

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

Shetland Stalls Installation Instructions

Ford Pick Up Rear leaf Spring Kit Installation Instructions

Giraud Tool Company, Inc.

Pow-R-Feed Systems Service Manual

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

This instruction manual is an in-depth look and explanation of how to assemble and install the Murphy Bed properly and efficiently.

Healthcare LED TROFFER FLANGE (HSTLED Family)

Oxford Stalls Installation Instructions

Installation Instructions

P /8 Ring Diameter 90. Trim Ring Mounting Holes P /8. 393/16 Ring Diameter. Stud Minimum

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Arlink 8000 Workstation

Installation Instructions

MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS

EOS Direct/Indirect LED Pendant Luminaire

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Assembly & Installation Instructions

Mach Wall Installation Instructions

M10 x 75mm Sockethead Cap Screws. 5mm Fender Washer (12) Included - (8) Required. #10 x 2.5" PH Wood Screws. (30) Included - (24) Required

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Installation Instructions

BLUEMOTION UXP, CDP, SD

Angled Side Flush with Panel Face

RBP-1215B-RX DODGE RAM QUAD CAB RX3

`48-`56 Ford Pickup Rear leaf Spring Kit Installation Instructions Tech Line:

Track Rack. * Track Racks are not lockable

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

Desk/Wall-Mount Rack

MPA-9000 Universal Ceiling Projector Mount Kit

CEILING-MOUNTED MONORAIL ANCHOR TRACK SYSTEM Assembly and Operation Instruction Manual

EOS LED Surface Mounted Luminaire

Diva Acoustical Ceiling

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

STOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

ETC Installation Guide

Parts list continues on Page 2 HOUSE PARTS PACKED IN HOUSE BOX PARTS IN SMALL PLASTIC BAG (HARDWARE) POST PARTS PACKED IN THIS BOX (LARGE PLASTIC BAG)

Installation Instructions

S48-L12-SC AND G48-L12-GC STEEL PORTA-DOCK S82 SC 6 X 12 PLATFORM AND G82 GC 6 X 12 PLATFORM

Wall Mount Assembly and Mounting Guide (55 /84 )

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

Linear Hook- on Worksurfaces

POWER PEAK TM ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation. Version 1, Rev D P/N

Setting Up the Polycom RealPresence Group Series Media Center

INSTALLATION INSTRUCTIONS GRILLE GUARD 09-ON DODGE RAM PART #

SLOT INSTALLATION GUIDE Indoor IP20

Prepare the Fixture. Sage 37 Bath. Back Plate Installation (Horizontal) Installation Instructions for 700BCSAGW37_

Lab Style Table Frame Part No Assembly Guide Automation Technology

Riverside. Oakmont Queen Storage Bed Assembly Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

P a r k c o n s o l e s i n k a s s e m b l y i n s t r u c t i o n s

IMPORTANT: WILL NOT FIT COUNTRYMAN MODELS

TM12 ASSEMBLY INSTRUCTIONS

southpaw enterprises, inc.

The Useless Machine. Parts Only - Build Guide v0001

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

Yes 20 Charging Wall Cabinet for Tablets

Yes 20 Charging Wall Cabinet for Tablets

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

NOTE: Top section pole (Q) is packed INSIDE bottom section pole (S)

Transcription:

ISTALLATIO ISTRUCTIOS CAUTIO! READ THIS FIRST - IMPORTAT SAFETY ISTRUCTIOS Carefully read the instructions pertaining to your fixture. IF YOU HAVE AY QUESTIOS REGARDIG THE PROPER ISTALLATIO OR LOCAL CODES, COSULT A QUALIFIED ELECTRICIA. To avoid shock hazard, do not work with live electrical wires. Install the fixture only in indoor applications. Do not install outdoors or in applications other than the intended use. Install and wire the fixture in locations in compliance with the ational Electric Code and any local codes. Do not remove any protective films over the lens or reflectors until installation is complete. Do not energize the fixture without removing the protective films from the lens or reflectors. WARIG: THIS PRODUCT MUST BE ISTALLED I CORDE WITH THE APPLICABLE ISTALLATIO CODE BY A PERSO FAMILIAR WITH THE COSTRUCTIOS AD OPERATIO OF THE PRODUCT AD THE HAZARDS IVOLVED. WARIG: RISK OF FIRE, MIIMUM OF 90 C SUPPLY CODUCTOR. COSULT A QUALIFIED ELECTRICIA TO ESURE CORRECT BRH CIRCUIT CODUCTOR. WARIG: TO AVOID SHOCK HAZARD, DISCOECT THE POWER AT THE PAEL BOARD (CIRCUIT BREAKER BOX) BEFORE BEGIIG ISTALLATIO. A. GRID ISTALLATIO The MediMode luminaire can be installed into standard suspended grid ceilings with a 1 or 1½ high grid. The weight of the luminaire is supported by the grid and supplemented with direct connection to the building structure. The steps for installation are as follows: Hanger Tab 1. Inspect the ceiling grid to make sure it is supported from the building structure as recommended by the ceiling grid manufacturer s instructions. It may be necessary to add or remove grid sections to accommodate the fixture within the existing grid. 2. Angle the fixture up through the opening in the grid. Once through the opening, lower the luminaire so that its flanges are supported on the ceiling grid. 3. Locate the hanger support tab at each corner of the luminaire housing as shown in Figure 1. Use a hanger wire at all four corners to tie the luminaire to the building structure above. Use 12 gauge minimum hanger wire rated for such application. In addition, follow local building codes regarding required additional support of luminaires. 4. Proceed to section C. Figure 1: Hanger Tab

ISTALLATIO ISTRUCTIOS B. FLAGE ISTALLATIO The MediMode luminaire can be installed into a solid material ceiling when the F ceiling option is specified, or with the addition of the FK24H (FK22H for 2x2) flange kit accessory. 1. Make a ceiling cutout of 24-1/8 x 48-1/8 (24-1/8 x 24-1/8 for 2x2) in the desired location square and accurate within 1/16. It is recommended that the opening should be cut into whole pieces of ceiling material to minimize seams and joints intersecting the cut opening. This limits stress on taped joints and ensures a better fit of the fixture flange against the ceiling surface. 2. Install rigid framing (i.e. C-channel) around the cut opening with the vertical edge of the channel flush with the cut opening. Secure the ceiling material to the bottom surface of the frame. Support the rigid frame from the building structure. 3. Prepare mounting holes in the framing channel according to Figure 2. 18" (8" FOR 2X2) 18" (8" FOR 2X2) 25 1/8" YOKE MOUTIG CETER-TO-CETER 24 1/8" CEILIG CUTOUT WIDTH CEILIG SUPPORT CHAEL CEILIG MATERIAL 48 1/8" CEILIG CUTOUT LEGTH (24 1/8" FOR 2X2) Figure 2: Recommended Ceiling Cutout and Support Channel Preparation

ISTALLATIO ISTRUCTIOS B. FLAGE ISTALLATIO 4. Thread the ¼ -20 bolts through the Yokes from the top as shown in Figure 3. Tighten the ¼ -20 nuts onto the bolts from below until snug to the yoke face. 5. Secure Yokes to framing on plenum side of ceiling opening as shown in Figure 3. 6. Remove (4) 3/8 diameter knockouts on the back of the housing to align with the ¼ -20 bolts. 7. Make electrical connections as outlined below in Section C. 8. Lift fixture into ceiling opening, ensuring the (4) ¼ -20 bolts from Step 4 pass through the (4) housing holes produced in Step 6. Install rubber washers, steel washers, and ¼ -20 nuts as shown in Figure 4. 9. Tighten the (4) nuts sufficiently to draw fixture up and create full surface contact of the fixture Flange Trim to the ceiling opening. 10. CRITICAL: Ensure the nuts are fully threaded onto the bolts. Ensure the bolts protrude down from the inside surface of the fixture housing O MORE THA 1, or interference with reflector may occur. Make adjustments to the bolt positions as needed (see Step 4 above). 11. Proceed to Section C. CEILIG SUPPORT CHAEL CEILIG MATERIAL YOKE 1/4"-20 UT 1/4"-20 BOLT SECURE YOKES TO FRAMIG CHAEL. (HARDWARE SUPPLIED BY OTHERS) 1/4"-20 BOLT 1/4"-20 UT Figure 3: Yoke Mounting CEILIG SUPPORT CHAEL CEILIG MATERIAL Figure 3: Yoke Mounting YOKE 3/8" KO TYPICAL (4) PLES MediMode FIXTURE 1/4"-20 BOLT RUBBER WASHER STEEL WASHER 1/4"-20 UT FLAGE TRIM 1" MAXIMUM 1/4"-20 UT RUBBER WASHER STEEL WASHER 1/4"-20 UT Figure 4: Fixture Installation Figure 4: Fixture Into Hard Installation Ceiling Into Material Hard Ceiling Material

ISTALLATIO ISTRUCTIOS C. MAKIG ELECTRICAL COECTIOS ote: The circuit should be shut-off at the breaker before beginning this step. 1. If Lensed Door is present, remove screws around door frame and let the door hang down by hinge or tethers. 2. Lower Lens/Reflector assembly by grasping along one side edge of reflector and pulling straight away from housing. Grasp assembly along opposite side edge and pull away from housing. Lens/Reflector assembly may temporarily rest on wire springs away from housing as shown in Figure 5. 3. Remove Lens/Reflector assembly by squeezing the legs of the wire springs together and removing the feet of the wire springs from the guide slots in the housing. CAUTIO: Do not drop Lens/Reflector assembly. 4. Secure conduit or cable (supplied by others) to the back of the housing through a knockout. ote, if Lensed Door is present, a threaded hub or equivalent fitting listed for Wet Locations must be used. Locate the leads for the Ambient, Exam, LVC, and/or ight Light loads depending on product configuration, and connect accordingly. 5. If an emergency battery backup is present, follow supplementary Installation Instruction. 6. If a Low Voltage Controller (LVC) is present, secure conduit or cable (supplied by others) to the back of the housing through a knockout. Locate the low voltage control wires of the in-fixture device and terminate to corresponding wiring of the nurse call system (Supplied by others. See Figures 6-9 in Section D for further details on LVC wiring). 7. If LVC is not present, proceed to Section E. WIRE SPRIG Figure 5 Figure 5

ISTALLATIO ISTRUCTIOS D. LOW VOLTAGE COTROLLER (LVC) WIRIG Locate the wiring diagram that matches the LVC option selected for the product being installed. 120 V APPLICATIOS / BROW PIK AMBIET/ READIG / GREE 240/277 V APPLICATIOS BROW / / PIK AMBIET/ READIG GREE Figure 6: LVC1- Independent control of ambient/reading mode with one SPST momentary switch 1 2 After power up: Off Off 1st Switch On Off 2nd Switch Off On 3rd Switch On On 4th Switch Off Off Sequential 120 V APPLICATIOS BROW / PIK / GREE AMBIET/ READIG IGHT LIGHT 240/277 V APPLICATIOS BROW / / PIK AMBIET/ READIG GREE IGHT LIGHT Figure 7: LVC2- Sequential control of two modes with one SPST momentary switch

ISTALLATIO ISTRUCTIOS MODE SELECT SWITCH STEP DIMMIG SMOOTH DIMMIG 0-10v AALOG COTROL AMBIET/ READIG COMMO PIK TO URSE CALL SYSTEM RECEPTLE O (1) MS2=O (1) MS3= MS2=O (1) MS3=O (1) O (1) BROW DIM2 0-10V DIM2 COMMO DIM1 0-10V DIM1 COMMO SWITCH COMMO SWITCH 3 SWITCH 2 SWITCH 1 LVC HOT 120-277V COMMO EARTH GROUD/CHASSIS 1 2 3 GREE HOT/LIE 120 TO 277 V COMMO EARTH GROUD LVC COTROL COECTIOS HIGH VOLTAGE SOURCE/OUTPUTS SWITCH 1 OPTIOAL WALL SWITCH(ES) Figure 8: LVCDST1 and LVCDSM1 - Independent dimming control of ambient/reading mode MODE SELECT SWITCH STEP DIMMIG SMOOTH DIMMIG 0-10v AALOG COTROL AMBIET/ READIG IGHT LIGHT COMMO COMMO PIK TO URSE CALL SYSTEM RECEPTLE O (1) MS2=O (1) MS3= O (1) MS2=O (1) MS3=O (1) BROW DIM2 0-10V DIM2 COMMO DIM1 0-10V DIM1 COMMO SWITCH COMMO SWITCH 3 SWITCH 2 SWITCH 1 LVC HOT 120-277V COMMO EARTH GROUD/CHASSIS 1 2 3 HOT/LIE 120 TO 277 V COMMO GREE EARTH GROUD LVC COTROL COECTIO S HIGH VOLTAGE SOURCE/OUTPUTS SWITCH 2 SWITCH 1 OPTIOAL WALL SWITCH(ES) Figure 9: LVCDST2 and LVCDSM2 - Independent dimming control of ambient/reading mode and independent non-dim control of night light.

ISTALLATIO ISTRUCTIOS E. FIAL ISTALLATIO STEPS 1. Reinstall the lens/reflector assembly by squeezing the wiresprings and passing them through the guide slots in the housing. Reflector assembly may rest in the lower position temporarily if needed. See Figure 5. 2. Push lens/reflector assembly up into housing. For best results, push along one side edge of reflector, then push assembly along opposite side edge. 3. Reinstall Lensed Door if present. Start each screw with manual screwdriver to avoid cross-threading. 4. If present, remove film from Lensed Door.