Simulation of Ferroresonance Phenomena in Power Systems

Similar documents
Ferroresonance in MV Voltage Transformers: Pragmatic experimental approach towards investigation of risk and mitigating strategy

Ferroresonance Experience in UK: Simulations and Measurements

EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION

A Study on Ferroresonance Mitigation Techniques for Power Transformer

Accurate Modeling of Core-Type Distribution Transformers for Electromagnetic Transient Studies

The Effect of Fault States of the Twelve-pulse Rectifier During the Recuperation

Capacitive Voltage Substations Ferroresonance Prevention Using Power Electronic Devices

A Special Ferro-resonance Phenomena on 3-phase 66kV VT-generation of 20Hz zero sequence continuous voltage

Identification of network models parameters for simulating transients

In power system, transients have bad impact on its

Analysis of the Disturbances in Distribution Networks using Matlab and ATP

Long lasting transients in power filter circuits

PREDICTIVE CONTROL OF INDUCTION MOTOR DRIVE USING DSPACE

Modeling Ferroresonance Phenomena on Voltage Transformer (VT)

Research Article Resistive Ferroresonance Limiter for Potential Transformers

HYBRID STATCOM SOLUTIONS IN RENEWABLE SYSTEMS

ACCURACY OF VOLTAGE TRANSFORMERS DESIGN CRITERIA AND A SURVEY ON THE PRECISION AND REPRODUCIBILITY OF A NEW MODEL-BASED CALIBRATION APPROACH

DIFFERENCE BETWEEN SWITCHING OF MOTORS & GENERATORS WITH VACUUM TECHNOLOGY

Demagnetization of Power Transformers Following a DC Resistance Testing

Tab 2 Voltage Stresses Switching Transients

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

Analysis of Transients during the Power System Restoration

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

Modeling insulation in high-voltage substations

Simulation and Analysis of Ferroresonance in Power System

Validation of a Power Transformer Model for Ferroresonance with System Tests on a 400 kv Circuit

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

of the improved scheme is presented. Index Terms Inrush current, power quality, transformer.

AORC Technical meeting 2014

Parameter Study of Ferro-Resonance with Harmonic Balance Method

TECHNICAL BULLETIN 004a Ferroresonance

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Dynamic Phasors for Small Signal Stability Analysis

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

Estimation of Re-striking Transient Overvoltages in a 3-Phase 132KV Gas insulated Substation

Electric Stresses on Surge Arrester Insulation under Standard and

ELECTRICAL POWER ENGINEERING

REDUCTION OF TRANSFORMER INRUSH CURRENT BY CONTROLLED SWITCHING METHOD. Trivandrum

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

II. RESEARCH METHODOLOGY

Innovative Science and Technology Publications

ACOUSTIC AND ELECTROMAGNETIC EMISSION FROM CRACK CREATED IN ROCK SAMPLE UNDER DEFORMATION

FERRORESONANCE SIMULATION STUDIES USING EMTP

Exercise 9. Electromagnetism and Inductors EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Magnetism, magnets, and magnetic field

Comprehensive Study on Magnetization Current Harmonics of Power Transformers due to GICs

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Efficient HF Modeling and Model Parameterization of Induction Machines for Time and Frequency Domain Simulations

ANEW, simple and low cost scheme to reduce transformer

The Impact of Connecting Distributed Generation to the Distribution System E. V. Mgaya, Z. Müller

[2007] IEEE. Reprinted, with permission, from [Jiaxin Chen, Youguang Guo, Jianguo Zhu, A General Method for Designing the Transformer of Flyback

A C. Wallner Siemens AG Berlin, (Germany)

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Discrimination between Inrush and Fault Current in Power Transformer by using Fuzzy Logic

Three-Phase/Six-Phase Conversion Autotransformers

Estimation of Re-striking Transient Over voltages in a 132KV Gas insulated Substation

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

Comparison of integrated and composed step-down converter in terms of EMC

Traction Drive with MFT - Novel Control Strategy Based on Zero Vectors Insertion

SERIES ACTIVE power filters have proved to be an interesting

Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Direct Harmonic Analysis of the Voltage Source Converter

Generation of Voltage Reference Signal in Closed-Loop Control of STATCOM

VALIDATION THROUGH REAL TIME SIMULATION OF A CONTROL AND PROTECTION SYSTEM APPLIED TO A RESONANT EARTHED NEUTRAL NETWORK

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

Active Elimination of Low-Frequency Harmonics of Traction Current-Source Active Rectifier

DC current interruption tests with HV mechanical DC circuit breaker

SUPPRESSION METHODS FOR VERY FAST TRANSIENT OVER- VOLTAGES ON EQUIPMENT OF GIS

CHAPTER-III MODELING AND IMPLEMENTATION OF PMBLDC MOTOR DRIVE

DIGITAL SIMULATION OF MULTILEVEL INVERTER BASED STATCOM

Power Quality Improvement in Distribution System Using D-STATCOM

INVESTIGATION INTO THE HARMONIC BEHAVIOUR OF MULTIPULSE CONVERTER SYSTEMS IN AN ALUMINIUM SMELTER

Demagnetization of instrument transformers before calibration

Power Systems Modelling and Fault Analysis

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Digital Simulation of Thyristor Controlled Interphase Power Control Technology (TC- IPC) to limit the fault currents

Reducing the magnetizing inrush current by means of controlled energization and de-energization of large power transformers

Simulation Results of a Shunt Active Power Filter with Control Based on p-q Theory

Conventional Paper-II-2013

University of Pittsburgh

A NEW DESIGN METHOD OF OUTPUT FILTER FOR SPACE VECTOR PWM FED INDUCTION MOTOR

CONTENTS. 1. Introduction Generating Stations 9 40

Volume I Issue VI 2012 September-2012 ISSN

Short-Circuit Analysis IEC Standard Operation Technology, Inc. Workshop Notes: Short-Circuit IEC

Simulation of characteristics of impulse voltage generator for testing of equipment using MATLAB Simulink

Keywords: No-opto flyback, synchronous flyback converter, peak current mode controller

, answer the next six questions.

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Pre-insertion Resistor of Switching Shunt Capacitor Banks

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

MUCH research work has been recently focused on the

PARALLELING of converter power stages is a wellknown

ANALITICAL ANALYSIS OF TRANSFORMER INRUSH CURRENT AND SOME NEW TECHNIQUES FOR ITS REDDUCTION

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Accurate Current Measurement Transducer for Relaying Purpose

Mitigation of an Inrush Current of Power Transformer by using PWM-Inverter based Series Voltage Compensator

TECHNICAL REPORT. Insulation co-ordination

Transcription:

Proc. of the 5th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 68, 5 (pp37377) Simulation of Ferroresonance Phenomena in Power Systems JIŘÍ DRÁPELA, PETR TOMAN, JAROSLAVA ORSÁGOVÁ, MILAN KRÁTKÝ Department of Electrical Power Engineering, FEEC Brno University of Technology Technická 848/8, 66 Brno CZECH REPUBLIC drapela@feec.vutbr.cz, toman@feec.vutbr.cz, http://www.ueen.feec.vutbr.cz Abstract: The paper deals with a comparison of two published approaches to modelling the properties of magnetic circuits leading to a dynamic description of hysteresis characteristic. The comparison of the two methods is carried out both theoretically and in practical measurements on instrument voltage transformer. The paper also deals with the possibility of employing the models for ferroresonance simulations in power systems. Key-Words: Ferroresonance Phenomena, Power Systems, Modelling, Instrument Voltage Transformer Introduction In the simulation of transient phenomena in powers systems it is necessary to use models of elements which have electrical properties corresponding with real elements of power systems. Just the model of transformer which respect real hysteresis loop has been a subject of miscellaneous researches for a long time. For determining of exact model of hysteresis loop it is necessary to know a lot of parameters of magnetic circuit or to have a measurement behind knee of magnetization curve. Next it is possible to use calculated model in simulation of transient phenomena. Measurement on Instrument Voltage Transformer Prior to creating a faithful transformer model it was necessary to perform a series of measurements for different operating points. In view of the requirement to model a measuring voltage transformer, a transformer was chosen that can currently be found in HF power networks, namely the TJC4 transformer with a nominal / 3 transformer ratio of =. The measurement / 3 was performed in two stages. In the first stage, magnetic characteristic was measured on the lower-voltage side. Voltage on the higher-voltage side was detected using a HV probe. The voltage and current waveforms were recorded using an analyser with a sampling frequency of khz. In the second stage, a check measurement of magnetization characteristic was performed in a HV laboratory, with direct measurement of primary current using a milliammeter. Fig. gives a comparison of the magnetization characteristics obtained from both measurements. U [V] 8 6 4 U - recalculated measurement on the lower-voltage side U - measurement on the high-voltage side 4 6 8 4 I [ma] Fig. Magnetization characteristic of the TJC4 transformer In this measurement, a total of operating points were measured over the whole range of magnetization characteristic for the sake of additional verification of model functionality. Fig. gives the development of hysteresis loops for individual operating points. 5 4 3-4 -5 -. -.5.5. Fig. Hysteresis loops for the operating points measured

Proc. of the 5th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 68, 5 (pp37377). Calculation of transformer model The Mathematica program environment was used in the calculations. Numerical voltage integration was performed for all the operating points measured. For the model, which depends on the current derivative, numerical differentiation was performed again for all the operating points measured. Thus in addition to the measured voltage waveforms u(t) and current waveforms i(t) the waveforms of conjugate magnetic flux Ψ(t) and current derivative i (t) were obtained. These waveforms were sampled at a frequency of 5 khz. Subsequently, the coefficients of individual models were calculated using the Lavemberk-Marquart method. We now have at our disposal all the data necessary for transformer modelling. In [9] a basic overview of published models is given, which will be applied to the above measurement... Model This model of hysteresis loop starts from [4] and is formed by the function dψ i Ψ = f Ψ + g Ψ () ODD EVEN dt where 3 5 7 9 fodd( Ψ) = aψ + a3ψ + a5ψ + a7ψ + a9ψ + aψ +... 4 6 8 geven( Ψ) = b + bψ + b4ψ + b6ψ + b8ψ + bψ +... Ψ = Ψ t () u () t q Ψ() t q i ( t) + q3 i ( t) + q4 Ψ( t) q6 q i() t + q Ψ t = + (3) + q ( ())8 5 7 A comparison of the model with the measurement for the last operating point is given in Fig. 5. Fig.4 Hysteresis loops If in order to obtain the model coefficients we apply the same procedure as in the preceding cases, we obtain an equation of the model. For the operating point being measured, this model (in red) exhibits a perfect agreement between the model and the measurement (in blue) the curves are almost identical, see Figs.3 and 4. Fig.5 Current waveforms and hysteresis loops Fig.3 The waveforms of current.. Model This model starts from [] and is formed by the function ( i() t, i () t, Ψ() t, Ψ () t ) = F () and it is possible write this function (equation ) in next form (equation 3). For the solution of the model it is necessary to solve a first-order differential equation. In the experiments, some problems with the convergence of numerical solution were encountered. 3 Simulation of Simple Ferroresonance cicrcuit Fig.6 gives the block arrangement of a series ferroresonance circuit in the Matlab Simulink environment. The circuit consists of an ideal ac supply source, its internal resistance and reactance (Ri, Xi), a

Proc. of the 5th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 68, 5 (pp37377) series capacitor (C), a resistance and inductance representing the primary transformer winding, and a block representing the non-linear inductance of transformer with losses included. AC source Ri, Xi C Rt, Xt Nonlinear_L In Out In Fig.8 the waveforms of hysteresis loops are compared while in Fig.9 the phase plane representations are compared. The red points represent the so-called S- representation (semi-poincaré). It is obvious that for model the representation is symmetrical, i.e. a fundamental-frequency ferroresonance is concerned, while for model the representation is unsymmetrical and the trajectory of motion in the phase plane reveals the doubling of periods. On close examination of the hysteresis loop this is also evident for model. Fig.6 Simple series ferroresonance circuit Fig.7 shows a comparison of voltage waveforms for individual models; the supply voltage of the circuit has an amplitude of V and a capacitance of 6 nf. 3 x 4 model.5. 3 x 4 model.5. Fig.7 Comparison of the waveforms of both models 5 model 5 model 4 Modelling of a Real Network To verify model functionality several typical configurations susceptible to ferroresonance appearance were chosen and simulated. In addition to verifying model functionality, these simulations are to demonstrate the complexity of check calculation for ferroresonance appearance when designing a new or reconstructing an existing power engineering plant. The Matlab-Simulink software was used in the simulation. Fig. shows the connection of the line in the kv switching station in Bezdecin. This configuration belongs to configurations susceptible to ferroresonance appearance and thus needs to be examined more closely. Here the main elements of ferroresonance circuit are the non-loaded instrument voltage transformer and the control capacitance of the circuit breaker. When switching off the circuit breaker V, with the bus disconnector O switched on and the outlet disconnector O switched off, the waveforms of the voltage measured on the instrument transformer were as shown in Fig.. -5-5 -.. -.. Fig.8 Comparison of the hysteresis loops 3 x 4 model 3 x 4 model -5 5-5 5 Fig.9 Comparison of the waveforms in the phase plane and semi-poincaré representation Fig. Voltage waveforms The circuit in question is a series ferroresonance circuit, where the circuit breaker and disconnector determine the initial conditions given by the instant of connection. Other initial conditions may be given, for example, by residual magnetic flux or core premagnetization due to the dc component of voltage, etc. These conditions are not taken into consideration.

Proc. of the 5th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 68, 5 (pp37377) kv O V IVT Fig. Scheme of the outlet in the switching station 4. Disconnecting by circuit breaker V, with disconnector O connected and O disconnected As all ferroresonance circuits, this circuit, too, is very sensitive to initial conditions. The instant of disconnection, which forms the initial condition, is in this case firmly fixed by the circuit breaker, which will disconnect the circuit in current zero (Note: about current zero). Another initial condition, which we do not consider, may be the pre-magnetized core due to the dc component of voltage. In such a case the circuit is more susceptible to transferring to ferroresonance. C O appeared in the circuit. The phenomenon became steady and it will not disappear until it is damped one way or another. For damping it is possible to use, for example, a resistor in the secondary winding of instrument voltage transformer, a transformer with a higher value of nominal voltage, a circuit breaker with a lower control capacitance (Fig.4), etc. x 5 Supply voltage u=f(t).5..5..5.3.35.4.45.5 x 5 Voltage on IVT ul=f(t).5..5..5.3.35.4.45.5 Conjugate magnetic flux.5..5..5.3.35.4.45.5 Magnetizing current i=f(t). Ri, Xi Disconnector O Circuit breaker V Rt, Xt AC source In -. R3 R R IVT 45kV/V.5..5..5.3.35.4.45.5 Out Fig.3 Voltage, magnetic flux and current waveforms Fig. Schematic diagram of circuit Simulation is thus conducted from steady state, and initial conditions are regarded as defined. The circuit is then created in the Simulink environment (Fig.). The transformer block is identical with the block described above for model. When the circuit breaker contacts are disconnected, the control capacitance C comes into play. Parallel resistors are placed in the circuit because of the presence of the circuit breaker block. The circuit is solved by the method of nodal voltages, and to simulate the switching element it is necessary to define the circuit admittance matrix also without switching elements. The values of these resistors are, of course, large and have no effect on simulation results. Fig.3 gives the waveforms of voltage, current and conjugate magnetic flux for the simulation of disconnecting the outlet for capacitance C = 6pF and bus voltage amplitude 99kV. This value corresponds to the nominal value of voltage increased by the tolerance (%) for HV. This increased voltage is a common operating state switching stations operate at this value in order to respect the permissible voltage drop at the end of the line. At time t =.4 the disconnection of the circuit breaker took place. It can be seen that in the course of several periods ferroresonance with a maximum voltage of kv.5 -.5 x 5 Voltage on IVT ul=f(t).5..5..5.3.35.4.45.5 Fig.4 Voltage waveform for pf control capacitance of the circuit breaker 5 Conclusion Two models of electrical properties of transformers are presented in the paper. What is common to both models is the way they are obtained, namely from measuring in oversaturated region (as far behind the bend of magnetization characteristic as possible). Model, presented in [4], can be seen as more faithful. The concluding part deals with the simulation of disconnecting the outlet of a kv switching station, with a good agreement between the measured and the simulated voltage waveforms. Practical experience shows that a reduction of the losses in magnetic circuits of transformers is ever more frequently accompanied by the appearance of ferroresonance phenomena in power networks. It is

Proc. of the 5th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 68, 5 (pp37377) obvious that it will be necessary to include the calculation of ferroresonance phenomena in the methodology of designing MV and HV facilities. Acknowledgment: This paper contains the results of research works funded from project No. GA/3/P33 of the Grant Agency of the Czech Republic and the results of research works funded from project No. MSM6356 of the Ministry of Education, Youth and Sports of the Czech Republic. References: [] BELÁŇ, A., ELESCHOVÁ, Ž, JANÍČEK, F., The Cause of False Operating of the Rotor Ground Fault Protection Based on the AC Injection Method, PowerTech 5 IEEE Conference proceedings, St. Petersburg, 5 [] BRETTSCHNEIDER, Z., KYNCL, J., ŠPETLÍK, J., The New Conception of Modelling of the Transformer in Operating Conditions (In Czech), ELEN 4, Czech Technical University in Prague, Prague, Czech Republic, ISBN 839565-8. [3] IEEE Working group: Modelling and Analysis Guidelines for Slow Transients Part III: The study of Ferroresonance, IEEE Transaction on Power Delivery,, Vol.5, No., p. 5565 [4] JAVORA, R, Analysis and Simulation of Ferroresonance phenomena in Power systems (In Czech), Brno University of Technology, Brno, Czech Republic. 73 pages, Ph.D. thesis, 4 [5] JAVORA, R., IWAHARA, M., YAMADA, S. Dynamic Hysteresis Loop and its Application to a Series Ferroresonance Circuit, Institute of Nature and Environmental Technology, Annual report No., Kanazawa University, Kanazawa, Japan,, p. 75. [6] JAVORA, R., YAMADA, S., IWAHARA, M. Simulation of Ferroresonance Occurring in Power System Containing Voltage Transformer, International Journal of the Japan Society of Applied Electromagnetics and Mechanics, 3, Vol., No., p. 37-4. [7] KYNCL, J., TLUSTÝ, J., A model of Hysteresis Loop in Transformers and Induction Heating, RUPEC [8] SAITO, Y., NAMIKI, M., HAYANO, S., TSUYA, N. Experimental verification of a Chua type magnetization model, IEEE Transaction on Magnetics, 989, Vol. MAG5, No. 4, p. 968-97. [9] TOMAN, P. Analysis of Nonstandard Overvoltages in Power Systems (In Czech), Brno University of Technology, Brno, Czech Republic, 66 pages, second doctorate thesis, 4 [] The MathWorks, Inc., 4, Using Simulink ver. 6 [] WALLING, R. A., HARTANA, R. K., RECKARD, R. M., SAMPAT, M. P., BALGIE, T.R. Performance of Metal-oxide Arresters Exposed to Ferroresonance in Padmount Transformers, IEEE Transactions on Power Delivery, 994, Vol. 9, No., p. 788-795. [] WOODFORD, D.A. Solving Ferroresonance Problem when Compensating a DC Converter Station with a Series Capacitor. IEEE Transaction on Power Systems, 996, Vol., No.3, p. 35-33