Photometric Test Report

Similar documents
Photometric Test Report

Photometric Test Report

Photometric Test Report

Photometric Indoor Test Report

Photometric Test Report

POST TOP FIXTURE C40T

Photometric Test Report

NVLAP LAB CODE:

NVLAP LAB CODE:

Horticultural Lighting Test Report

NVLAP LAB CODE:

Photometric Test Report

NVLAP LAB CODE:

Horticultural Lighting Test Report

NVLAP LAB CODE:

AcuVivid CV Series. sirs-e.com. Flexible White LED Strips

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

Equipment Used Model No Stock No Calibration Due Date

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

NVLAP LAB CODE:

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

Client submitted the sample. Catalog number is LRH240U. Received in working and undamaged condition. No modifications were necessary.

Model No Stock No Calibration Due Date Chroma Programmable AC Source PS-AC02

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Photometric Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Number Eight Lighting Company MPT2-HI-R-6-BK/15/DIM1-M-1000

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Checked X.CAO

Photometric Test Report

REVOLUTION LIGHTING TECHNOLOGIES INC

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA 93063

Checked X.CAO

Revolution Lighting 4139 Guardian St. Simi Valley CA 93063

71332 LED Dusk To Dawn (Area Light)

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

BARTCO Lighting 5761 Research Drive, Huntington Beach, CA 92649

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

Revolution Lighting Technologies 4139 Guardian Street, Simi Valley, CA No seasoning was performed in accordance with IESNA LM-79.

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE MAXLITE 12 York Ave. West Caldwell, NJ.

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report

LM Test Report

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

QPL ID # PLG2YNJ831VZ

Morris Products 53 Carey Road, Queensbury, NY 12804

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

LM Test Report

Transcription:

Photometric Test Report Relevant Standards IES LM-79-28 ANSI C82.77-22 UL1598-28 Prepared For Simkar Corporation Andre Duljas 7 Ramona Ave Philadelphia, PA 1912 United States Catalog Number RG2LEDWR1741U1 Order Number 1846592 Test Number 111699 Test Date 215-6-25-215-6-3 Prepared By Approved By Javier Caban, Technician Carissa Samonte-cam, Project Handler The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Underwriters Laboratories. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Test Number 111699 - Page 1 of 8

Table of Contents Integrating Sphere Results Page 3 Page 4 Distribution Results Conditions / / Polar Plot / Zonal / Luminance Candela Tabulation Coefficients of Utilization Page 5 Page 5 Page 6 Page 7 In-Situ Results Page 8 Laboratory results may not be representative of field performance Ballast factors have not been applied Testing was performed in a 2-meter integrating sphere using the 4π geometry method. Absorption correction was employed for Sphere measurement Test Number 111699 - Page 2 of 8

Luminaire Description: Lamp: Mounting: Ballast/Driver: White steel housing, white steel reflector plate, no enclosure 168 white LEDs, two boards with 84 LEDs each Pendant One Eaglerise ESL15-315P Luminaire Luminaire Characteristics Luminous Length: 23. in. Luminous Width: 18. in. Luminous Flux: Efficacy: CCT: CRI (Ra): Integrating Sphere 1771 Lumens 13.1 lm/w 4151 K 83.6 Distribution Total Luminaire Output: Luminaire Efficacy: Maximum Candela: 1719 Lumens 1.7 lm/w 5733 Candela Electrical Data at 277 VAC In-Situ Test Temperature: 25.2 C LED Temperature: 9.7 C Voltage: 277. VAC Driver Temperature: 61.2 C Current:.6541 A Maximum LED Current:.1498 A Power: Power Factor: 168.7 W.931 Frequency: 6 Hz Temperature is offset to an ambient temperature of 25 C as Current THD: 17.2 % described in UL1598-28. Test Number 111699 - Page 3 of 8

Spectral Flux (mw/nm) Color Quality - Integrating Sphere Integrating Sphere Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 25.6 C 12. VAC 1.438 A 171.8 W.995 6 Hz 5.2 % Total Output: Efficacy: CCT: CRI (Ra): CRI (R9): Chromaticity (x): Chromaticity (y): Chromaticity (u): Chromaticity (v): Chromaticity (u'): Chromaticity (v'): Duv: 1771 Lumens 13.1 lm/w 4151 K 83.6 12.4.374.3731.2223.3327.2223.499.2 Insert Chromaticity Diagram Color Rendering Index Detail Ra (CRI) R1 R2 R3 R4 R5 R6 R7 R8 R9 R1 R11 R12 R13 R14 83.6 81.8 9.3 95.4 81.3 81.8 86. 86.4 66. 12.4 76.4 79.4 64.7 84. 97.7 35. Flux vs Wavelength 3. 25. 2. 15. 1. 5.. 35 4 45 5 55 6 65 7 75 8 85 Wavelength (nm) Test Number 111699 - Page 4 of 8

Distribution - Goniophotometer Distribution Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 25.1 C 12. VAC 1.429 A 17.7 W.995 6 Hz 4.94 % Spacing Criteria Total Lumen Output: -18: 1.28 Luminaire Efficacy: 9-27: 1.28 Maximum Candela: 1719 Lumens 1.7 lm/w 5733 Candela Polar Plot 15 12 135 15 18 15 135 12 15 9 9 75 75 15 6 6 3 45 45 45 6 3 15 15 3 18 Deg. Plane 27 Deg. Plane Deg. Plane 9 Deg. Plane Zonal Lumen Summary Zone Lumens % of Luminaire Zone Lumens % of Luminaire Zone Lumens % of Luminaire -5 136.8% 6-65 1216 7.1% 12-125 5-1 45 2.4% 65-7 111 5.9% 125-13 1-15 663 3.9% 7-75 761 4.4% 13-135 15-2 2-25 91 1112 5.2% 6.5% 75-8 8-85 492 23 2.9% 1.2% 135-14 14-145 25-3 1291 7.5% 85-9 32.2% 145-15 3-35 1429 8.3% 9-95 15-155 35-4 4-45 45-5 5-55 55-6 1524 157 1564 1496 1381 8.9% 9.1% 9.1% 8.7% 8.% 95-1 1-15 15-11 11-115 115-12 155-16 16-165 165-17 17-175 175-18 Zone Lumens % of Luminaire -4-6 -9 9-18 7461 13472 17187 43.4% 78.4% 1 Test Number 111699 - Page 5 of 8

Vertical Angle (Degrees) Vertical Angle (Degrees) Candela Tabulation Horizontal Angle (Degrees) 22.5 45 67.5 9 112.5 135 157.5 18 22.5 225 247.5 27 292.5 315 337.5 5714 5714 5714 5714 5714 5714 5714 5714 5714 5714 5714 5714 5714 5714 5714 5714 5 5651 5716 574 5689 5697 5689 574 5716 5651 5716 574 5689 5697 5689 574 5716 1 5592 5657 5645 5631 5638 5631 5645 5657 5592 5657 5645 5631 5638 5631 5645 5657 15 5491 5558 5545 5532 5535 5532 5545 5558 5491 5558 5545 5532 5535 5532 5545 5558 2 5349 5418 543 5391 5391 5391 543 5418 5349 5418 543 5391 5391 5391 543 5418 25 5162 5232 5219 521 525 521 5219 5232 5162 5232 5219 521 525 521 5219 5232 3 4936 57 4994 4986 498 4986 4994 57 4936 57 4994 4986 498 4986 4994 57 35 4671 4739 4727 472 4713 472 4727 4739 4671 4739 4727 472 4713 472 4727 4739 4 4365 4428 442 4414 447 4414 442 4428 4365 4428 442 4414 447 4414 442 4428 45 417 478 473 466 459 466 473 478 417 478 473 466 459 466 473 478 5 3587 3687 3684 3675 3669 3675 3684 3687 3587 3687 3684 3675 3669 3675 3684 3687 55 3125 3179 3258 3249 3244 3249 3258 3179 3125 3179 3258 3249 3244 3249 3258 3179 6 2681 2726 2756 2787 2781 2787 2756 2726 2681 2726 2756 2787 2781 2787 2756 2726 65 222 2241 2241 2291 2284 2291 2241 2241 222 2241 2241 2291 2284 2291 2241 2241 7 1687 1729 173 1768 1756 1768 173 1729 1687 1729 173 1768 1756 1768 173 1729 75 1123 1142 1215 1212 1226 1212 1215 1142 1123 1142 1215 1212 1226 1212 1215 1142 8 615 629 673 671 616 671 673 629 615 629 673 671 616 671 673 629 85 26 26 133 122 12 122 133 26 26 26 133 122 12 122 133 26 9 95 1 15 11 115 12 125 13 135 14 145 15 155 16 165 17 175 18 Average Luminance (cd/m 2 ) Horizontal Angle (Degrees) 45 9 2139 2139 2139 45 2127 2156 2149 55 24 2127 2117 65 1951 1986 223 75 1625 1757 1774 85 885 5714 5148 Test Number 111699 - Page 6 of 8

Ceiling Cavity Reflectance Wall Reflectance Room Cavity Ratio (RCR) 1 2 3 4 5 6 7 8 9 1 7 8 Utilization of Lumens - Zonal Cavity Method Effective Floor Cavity Reflectance 2% 7 5 3 1 7 5 3 1 5 3 1 5 3 1 5 3 1 ** Values are expressed as Lumens delivered to the task surface ** 5 3 1 2461 2461 2461 2461 19985 19985 19985 19985 1997 1997 1997 18284 18284 18284 17538 17538 17538 17187 18688 17864 17126 1646 18218 17473 1681 16191 16741 16187 15679 1668 15616 15198 15448 1585 14745 14384 16958 15523 14335 13336 1653 15196 1414 13176 14583 13663 12867 1418 13248 12572 13495 12858 12291 11915 15427 13588 12164 113 14996 13314 11993 1929 12798 11665 1733 12321 11355 1543 11878 116 136 9979 1498 125 1472 931 13698 11774 1342 9234 11339 192 914 1935 9854 8978 1559 9626 8855 8476 12945 17 9132 7975 12578 156 932 7929 1138 8837 784 9795 865 7752 9475 8472 7667 7296 11938 9614 854 6935 1165 9449 7975 693 9136 782 6839 8843 7672 6776 8569 7529 6715 6355 1157 871 7174 614 1755 856 711 681 8292 6985 634 842 6865 5988 786 6749 5942 5596 1283 7928 6447 5429 11 787 6395 5412 7577 6293 5376 7361 6194 5342 7158 699 537 4975 96 7267 5838 4873 9353 7163 5795 4859 6964 571 4832 6777 5629 485 66 555 4779 4461 8995 6698 5323 448 8772 668 5287 4397 6435 5217 4376 6272 5148 4355 6118 582 4334 43 Cone of Light Tabulation Mounting Footcandles Diameter Height (Feet) at Nadir (Feet) 4. 357 5.18 6. 159 7.78 8. 89.3 1.4 1. 57.1 13. 12. 39.7 15.6 14. 29.2 18.1 16. 22.3 2.7 Cone of Light Plot Test Number 111699 - Page 7 of 8

In-Situ Test In-Situ Test Conditions Temperature Voltage Current Power Power Factor Frequency Current THD 23.3 C 12. VAC N/A N/A N/A 6 Hz N/A LED Temperature: Driver Temperature: Maximum LED Current: 9.7 C 61.2 C.1498 A Temperatures are offset to an ambient temperature of 25 C as described in UL1598-28 LED Temperature Location Driver Temperature Location Test Number 111699 - Page 8 of 8