Phase-sequence Phase-loss Relay

Similar documents
Model Number Structure

Single-phase Voltage Relay

Single-phase Current Relay

Phase-sequence Phase-loss Relay

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Model Number Structure

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

CSM_G7S-_-E_DS_E_7_1

Single-phase Current Relay

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

MY-GS CSM_MY-GS_DS_E_2_1

Switch Mode Power Supply

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Switch Mode Power Supply

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

Model Number Structure

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Model Number Structure

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Fluoro plastic housing for highest chemical and detergent resistance

SPST-NO SPDT DPST-NO DPDT

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

Safety Relay Unit. OFF-delay time

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

E8EB-N0C2B E8EB-N0B2B

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Solid-state Twin Timer

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

Model Number Structure

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Multipoint Temperature Controller

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Alternate Operation Relay 61F-AN/-APN2

Model Number Structure

E3X-DRT21/SRT21/CIF11

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Solid-state Timer H3DE

Solid-state Timer H3DS

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Distance-setting Photoelectric Sensor

Solid-state Timer H3DE

LED Displacement Sensor

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

SPST-NO SPDT DPST-NO DPDT

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

FA Wireless SS Terminals

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Ultraminiature Photoelectric Switches with Self-contained Amplifier

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

NEW. Better Productivity by Standstill and Low-speed Monitoring

20 Series Power Relays

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Classification Enclosure rating Contact form Contact material

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Relays with Forcibly Guided Contacts G7SA

Zelio Control Measurement Relays

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Distance-setting Photoelectric Sensor

Details on the New G2RS

S8V-NF (Single-phase 250 V 3 A / 6 A Type)

Coaxial Switch. Ordering Information. High-frequency, High-capacity Coaxial Switch Supporting Bandwidth to 26.5 GHz. Model Number Legend:

Self-powered Counter

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Transcription:

Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive phases, reversed phases, and phase loss when power is turned ON. Voltage detection method enables application for any load current. One SPDT output relay, 6 A at 250 VAC (resistive load). Output status can be monitored using LED indicator. Model Number Structure Model Number Legend K8AB-@@ 1 2 3 1. Basic Model K8AB: Measuring and Monitoring Relays 2. Functions PH: Phase-sequence Phase-loss Relay 3. Rated Input Voltage 1: 200 to 500 VAC Ordering Information List of Models Phase-sequence Phase-loss Relay Functions Rated input voltage (See note.) Model Phase sequence and phase loss monitoring 200 to 500 VAC K8AB-PH1 Note: The power supply is shared with the rated input voltage. Cat. No. N145-E1-02 Phase-sequence Phase-loss Relay K8AB-PH 1

Ratings and Specifications Ratings Rated input voltage Input load Reversed phase and phase loss operating time Reset method Indicators Output relays Output relay ratings Ambient operating temperature Storage temperature Ambient operating humidity Storage humidity Altitude Terminal screw tightening torque Terminal wiring method Three-phase, three-wire mode, 200 to 500 VAC 15 VA max. 0.1 s max. Automatic reset Power (PWR): Green, Relay output (RY): Yellow One SPDT relay (NC operation) Rated load Resistive load 6 A at 250 VAC (cosφ = 1) 6 A at 30 VDC (L/R = 0 ms) Inductive load 1 A at 250 VAC (cosφ = 0.4) 1 A at 30 VDC (L/R = 7 ms) Maximum contact voltage: 250 VAC Maximum contact current: 6 A AC Maximum switching capacity: 1,500 VA Minimum load: 10 ma at 5 VDC Mechanical life: 10,000,000 operations Electrical life: Make: 50,000 times, Break: 30,000 times 20 to 60 C (with no condensation or icing) 40 to 70 C (with no condensation or icing) 25% to 85% (with no condensation) 25% to 85% (with no condensation) 2,000 m max. 0.49 N m Recommended wire Solid wire: 2.5 mm 2 Twisted wires: AWG16, AWG18 Note: 1. Ferrules with insulating sleeves must be used with twisted wires. 2. Two wires can be twisted together. Recommended ferrules Al 1,5-8BK (for AWG16) manufactured by Phoenix Contact Al 1-8RD (for AWG18) manufactured by Phoenix Contact Al 0,75-8GY (for AWG18) manufactured by Phoenix Contact Case color Munsell 5Y8/1 Case material ABS resin (self-extinguishing resin) UL94-V0 Weight Approx. 110 g Mounting Mounted to DIN Track or via M4 screws (tightening torque: 1.2 N m) Dimensions 22.5 (W) 90 (H) 100 (D) mm 2 Phase-sequence Phase-loss Relay K8AB-PH Cat. No. N145-E1-02

Specifications Input voltage range Input frequency range Overload capacity Temperature influence Humidity influence Influence of power supply voltage Influence of power supply frequency Influence of input frequency Applicable Conforming standards standards EMC Safety standards Insulation resistance Dielectric strength 200 to 500 VAC 45 to 65 Hz Continuous input: 115% of maximum input, 10 s max.: 125% of maximum input Operating time Fluctuation based on measured value at standard temperature: 20 C to standard temperature: ±10% max. Standard temperature to 60 C: ±10% max. (Humidity: 25% to 80%) Operating time Based on ambient room humidity 25% to 80%: ±10% max. Operating time: ±10% max. Note: The error in the operating value and operating time under standard conditions. Operating time: ±10% max. (at 45 to 65 Hz) Note: The error in the operating value and operating time under standard conditions. At 45 to 65 Hz Operating time: ±10% max. Note: The error in the operating value and operating time under standard conditions. EN60255-5 and EN60255-6 Installation environment (Pollution Degree 2, Overvoltage Category III) EN61326 UL508 20 MΩ min. Between external terminals and case Between input terminals and output terminals 2,000 VAC for one minute Between external terminals and case Between input terminals and output terminals Noise immunity 1,500 V power supply terminal common/normal mode Square-wave noise of ±1 µs/100 ns pulse width with 1-ns rise time Vibration resistance Frequency 10 to 55 Hz, 0.35-mm single amplitude, acceleration 50 m/s 2 10 sweeps of 5 min each in X, Y, and Z directions Shock resistance 100 m/s 2, 3 times each in 6 directions along three axes (up/down, left/right, forward/backward) Degree of protection Terminal section: Finger protection Connections Wiring Diagram Phase Sequence and Phase Loss Operation Diagram Input Relay Phase Loss Operation Phase Sequence Operation Note: 1. Motor load phase loss cannot be detected. To detect motor load phase loss, use the K8AB-PM or K8AB-PA. 2. The K8AB-PH output relay is normally operative. 3. and function both as the power supply terminals and as input terminals. If the voltage drops below the minimum input voltage (60%), then the Relay will not operate due to an undervoltage. 4. Phase loss is detected based on the phase sequence, so phase loss cannot be detected for loads that generate inductive power, e.g., due to monitoring during operation. 5. Phase loss is detected based on voltage, so phase loss cannot be detected on the load side. Load Voltage input 14 Signal output 12 Relay signal output 11 Cat. No. N145-E1-02 Phase-sequence Phase-loss Relay K8AB-PH 3

Nomenclature Front Terminal block (See notes 1 and 2.) Indicators Item Power indicator (PWR: Green) Relay status indicator (RY: Yellow) Meaning Lit when power is being supplied (see note). Lit when relay is operating (normally lit). Power indicator Relay status indicator Note: 1. The input across and is used for the internal power supply. Therefore, the power indicator will not be lit if there is no input across and. 2. Use either a solid wire of 2.5 mm 2 maximum or a ferrule with insulating sleeve for the terminal connection. The length of the exposed current-carrying part inserted into the terminal must be 8 mm or less to maintain dielectric strength after connection. For 2.5 mm 2 or smaller solid wires For ferrules with insulating sleeves 8 mm max. 8 mm max. Recommended ferrules Phoenix Contact Al 1,5-8BK (for AWG16) Al 1-8RD (for AWG18) Al 0,75-8GY (for AWG18) 3. Tightening torque Recommended: 0.49 N m Maximum: 0.54 N m Operation and Setting Methods Connections 1. Input Connect using,, and. Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. 2. Outputs Terminals 11, 12, and 14 are output terminals for SPDT. Voltage input 14 Signal output 12 Relay signal output 11 Dimensions Load (Unit: mm) Phase-sequence, Phase-loss Relays K8AB-PH1 22.5 100 5 90 72 5 4 Phase-sequence Phase-loss Relay K8AB-PH Cat. No. N145-E1-02

Safety Precautions Precautions for Safe Use Make sure to follow the instructions below to ensure safety. 1. Do not use or keep this product in the following environments. Outdoors, or places subject to direct sunlight or wearing weather. Places where dust, iron powder, or corrosive gases (in particular, sulfuric or ammonia gas) exist. Places subject to static electricity or inductive noise. Places where water or oil come in contact with the product. 2. Make sure to install this product in the correct direction. 3. There is a remote risk of electric shock. Do not touch terminals while electricity is being supplied. 4. Make sure to thoroughly understand all instructions in the Instructions Manual before handling this product. 5. Make sure to confirm terminal makings and polarity for correct wiring. 6. Tighten terminal screws firmly using the following torque. Recommended tightening torque: 0.49 N m Maximum tightening torque: 0.54 N m max. 7. Operating ambient temperature and humidity for this product must be within the indicated rating when using this product. 8. There is a remote risk of explosion. Do not use this product where flammable or explosive gas exists. 9. Make sure that no weight rests on the product after installation. 10.To enable an operator to turn off this product easily, install switches or circuit breakers that conform to relevant requirements of IEC60947-1 and IEC60947-3, and label them appropriately. Precautions for Correct Use For Proper Use 1. Do not use the product in the following locations. Places subject to radiant heat from heat generating devices. Places subject to vibrations or physical shocks. 2. Make sure to use setting values appropriate for the controlled object. Failure to do so can cause unintended operation, and may result in accident or corruption of the product. 3. Do not use thinner or similar solvent for cleaning. Use commercial alcohol. 4. When discarding, properly dispose of the product as industrial waste. 5. Only use this product within a board whose structure allows no possibility for fire to escape. About Installation 1. When wiring, use only recommended crimp terminals. 2. Do not block areas around the product for proper dissipation of heat. (If you do not secure space for heat dissipation, life cycle of the product will be compromised.) 3. To avoid electrical shocks, make sure that power is not supplied to the product while wiring. 4. To avoid electrical shocks, make sure that power is not supplied to the product when performing DIP switch settings. Noise Countermeasures 1. Do not install the product near devices generating strong high frequency waves or surges. 2. When using a noise filter, check the voltage and current and install it as close to the product as possible. 3. In order to prevent inductive noise, wire the lines connected to the product separately from power lines carrying high voltages or currents. Do not wire in parallel with or on the same cable as power lines. Other measures for reducing noise include running lines along separate ducts and using shield lines. To avoid faulty operations, malfunctions, or failure, observe the following operating instructions. 1. When turning on the power, make sure to realize rated voltage within 1 second from the time of first supply of electricity. 2. Make sure to use power supply for operations, inputs, and transformer with the appropriate capacity and rated burden. 3. Maintenance and handling of this product may only be performed by qualified personnel. 4. Distortion ratio of input wave forms must be 30% or less. Use of this product with circuits that have large distortion in wave forms may result in unwanted operations. 5. Using this product for thyristor controls or inverters will result in errors. 6. When setting the volume, adjust the control from the minimum side to the maximum side. Cat. No. N145-E1-02 Phase-sequence Phase-loss Relay K8AB-PH 5

Questions and Answers Q Checking Operation Q Motor Load Phase Loss during Operation Phase Sequence Switch the wiring, as shown by the dotted lines in the connection diagram, to reverse the phase sequence and check that the K8AB operates. Phase Loss Create a phase loss for any input phase and check that the K8AB operates. Connection Diagram 3φ, 200 VAC Motor load phase loss cannot be detected during operation. It can be used to detect phase loss at startup. Normally, three-phase motors will continue to rotate even if one phase is open. The three-phase voltage will be induced at the motor terminals. The diagram shows voltage induction at the motor terminals when phase R has been lost with a load applied to a three-phase motor. The horizontal axis shows the motor load as a percentage of the rated load, and the vertical axis shows voltage as a percentage of the rated voltage. The lines in the graph show the voltage induced at the motor terminals for each load when phase loss occurs during operation. As the graph shows, voltage is induced at the motor terminals even if there is phase loss for a motor load, so the K8AB-PH1 cannot detect phase loss for motor loads during operation. Use the K8AB-PH1 to detect phase loss at startup. Q Can phase loss be detected on the load side? In principle, phase loss cannot be detected on the load side because the K8AB-PH1 measures three-phase voltage to determine phase loss. Characteristic Curve Diagram Voltage (as a percentage of rated voltage) Note: This characteristic curve shows the approximate values only. 100 95 90 85 80 75 70 65 60 55 50 45 0 10 20 30 40 50 60 70 80 90 100 110 Motor load (as a percentage of rated load) Note: For phase loss of phase R. VST, VTR, and VRS indicate the motor terminal voltage at phase loss. VST VTR VRS 6 Phase-sequence Phase-loss Relay K8AB-PH Cat. No. N145-E1-02

Cat. No. N145-E1-02 Phase-sequence Phase-loss Relay K8AB-PH 7

Warranty and Application Considerations Read and Understand this Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. N145-E1-02 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. Control Devices Division H.Q. Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7109/Fax: (81)75-344-7149 Printed in Japan 0706-0.7M (0505) (C)