ERAcare is an integrated lighting solution for the patient room environment. It fulfills the requirements for Examination, Reading and Ambient lighting while also simplifying the day-to-day efforts of the healthcare professional and facility maintenance staff. Every aspect of the design is focused on ease of use. Patients and staff alike want the best in care and ERAcare can help meet those expectations.
c a r e f o r t h e p a t i e n t ERAcare delivers the recommended illumination levels for patient reading. The patient s visual comfort is enhanced by the soft, indirect ambient lighting. There are a variety of switching options for patient ease-of-use. Optical compartments are positioned to minimize glare. c a r e f o r t h e h e a l t h c a r e p ro f e s s i o n a l ERAcare has no moving parts that need to be flipped or rotated. From its soft form to its antimicrobial finish, ERAcare is designed to compliment infectious control efforts. The recommended illumination levels for examination are met. LED night/chart lights and switches are positioned at either end of the luminaire and can be controlled individually or together. c a r e f o r t h e f a c i l i t y s t a f f The snap-in lenses provide tool-less lamp replacement. An optional bed shut-off switch minimizes the potential for luminaire damage from motorized patient beds. A removable ballast tray provides quick access to key electrical components.
I n t e g r a t e d O p t i c a l S o l u t i o n s A Lamp Compartments A Ambient C Front Exam C B Reading D Rear Exam D B ERAcare utilizes four separate optical compartments to provide three key illumination requirements for the patient room Exam, Reading and Ambient. These varied functions are integrated into a compact cross-section and can be activated without the need to flip, rotate or mechanically move any part of the luminaire. The needs of the patient and healthcare staff are a flip of the switch away. Function Recommended Levels 1 ERAcare Levels Exam Illumination of the patient bed for examination 50-100 Avg. Footcandles 112 Avg. Footcandles 2 80 Avg. Footcandles 3 Reading Illumination of both the horizontal and angled reading planes 20-50 Avg. Footcandles 65 Avg. Footcandles (horizontal) 54 Avg. Footcandles (angled) Ambient General room illumination 5-10 Avg. Footcandles 12 Avg. Footcandles 1 Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities. 2 Achieved with utilizing the exam and reading optical compartments. 3 Achieved with utilizing the exam optical compartments only. 4
P ro d u c t D e t a i l s 5 1 4 3 3 2 The small cross-section helps ERAcare blend into the patient room environment. The soft curved form eliminates sharp corners, simplifies cleaning and reduces visual size. 5-1/2 (139.7mm) 8-15/16 (227.3mm) No flat surfaces to sit items on. The die cast end caps and extruded aluminum housing provide durability. 1 Internal linear prisms help maintain a smooth exterior surface that is easy to wipe down. ERAcare s dual exam compartments promote better uniformity across the entire patient bed surface. 3 Multiple switching options are available to meet the needs of the installation. 4 The removable socket covers conceal the lamp socket and promote a uniform appearance of the illuminated lens. 5 2 The Bed Shut-off Switch option minimizes the potential for luminaire damage from motorized patient beds by disconnecting power to the bed when ERAcare is moved. As an option, a set of integrated LED chart/night lights are located at either end of the luminaire. Healthcare staff can conveniently operate these low level lights from both sides of the patient bed. ERAcare meets the most stringent illumination recommendations for exam and reading functions. The positive snap-in lenses provide tool-less lamp replacement. A removable ballast tray provides convenient access to key electrical components. ERAcare is available in four standard finishes all with an antimicrobial additive to inhibit the growth of microbes for the life of the product. ERAcare can be complimented with the WayGlo LED Night Lights. For more information on WayGlo or other Philips Healthcare solutions, go to the website or contact your local representative. Soft White Taupe Aluminum Almond WG1H WG1V WG2H WG2V 5
A m b i e n t ERAcare Candela Distribution (1) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing ambient lamp only. Report No.: ITL60756 Model No.: ECT5HO Efficiency: 80.9% 180 165 150 1800 1200 600 135 120 105 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Ambient Illumination Level Recommended Level* 5-10 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 ERAcare 12** * Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities ** Achieved utilizing the ambient optical compartment with (1) F54 T5HO lamp. 90 LEGEND: 0-deg: 45-deg: 90-deg: Patient Room View 11.0 13.1 15.4 17.5 19.2 20.2 20.2 19.2 17.5 15.4 13.1 11.0 12.1 14.4 16.9 19.3 21.2 22.3 22.3 21.2 19.3 16.9 14.5 12.1 12.4 14.8 17.2 19.5 21.4 22.5 22.5 21.4 19.5 17.2 14.8 12.4 12.0 14.2 16.4 18.5 20.1 21.1 21.0 20.1 18.5 16.4 14.2 12.0 11.2 13.1 14.9 16.6 18.0 18.7 18.7 18.0 16.6 14.9 13.0 11.1 10.0 11.6 13.1 14.4 15.5 16.0 16.0 15.5 14.4 13.1 11.6 10.0 8.8 10.1 11.2 12.2 13.0 13.4 13.4 13.0 12.2 11.2 10.0 8.8 7.6 8.6 9.5 10.3 10.8 11.1 11.1 10.8 10.3 9.5 8.6 7.6 6.6 7.4 8.0 8.6 9.0 9.3 9.2 9.0 8.6 8.0 7.3 6.6 5.7 6.3 6.8 7.3 7.6 7.8 7.8 7.6 7.3 6.8 6.3 5.7 5.0 5.5 5.9 6.3 6.5 6.6 6.6 6.5 6.2 5.9 5.5 4.9 4.4 4.8 5.2 5.5 5.7 5.8 5.8 5.7 5.5 5.2 4.8 4.4 Illumination values calculated at 30 AFF. 6
E x a m ERAcare Candela Distribution (3) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing 3 lamps (exam and reading). Report No.: ITL60757 Model No.: ECT5HO Efficiency: 64.1% 1300 2600 90 75 60 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 Reading Illumination Level (Patient bed positioned 30 AFF) Recommended Level* 50-100 ERAcare 112** 80*** 3900 0 15 30 LEGEND: 0-deg: 45-deg: 90-deg: 45 * Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities ** Achieved utilizing the exam and reading optical compartments with (3) F54 T5HO lamps *** Achieved utilizing the exam optical compartments with (2) F54 T5HO lamps Patient Room View Detail of Exam Surface Exam Surface 156 155 183 194 186 183 219 231 168 219 194 187 204 131 194 148 168 154 97.6 148 108 131 112 70.4 108 76.5 97.7 78.8 51.3 76.6 54.8 70.5 56.1 38.6 54.8 40.6 51.4 41.3 30.0 40.6 31.7 38.6 31.7 31.3 30.1 7
H o r i z o n t a l R e a d i n g ERAcare Candela Distribution (1) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing reading lamp only. Report No.: ITL60755 Model No.: ECT5HO Efficiency: 74.8% 1300 90 75 60 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Reading Illumination Level (Horizontal Plane) Recommended Level* 20-50 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 ERAcare 65** 2600 45 * Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities ** Achieved utilizing the reading optical compartment with (1) F54 T5HO lamp. 3900 0 15 30 LEGEND: 0-deg: 45-deg: 90-deg: Patient Room View Detail of Horizontal Reading Surface Horizontal Reading Surface 73.9 86.6 91.3 86.9 68.8 72.4 59.6 48.5 43.2 74.3 69.0 50.5 59.9 43.4 48.6 8
A n g l e d R e a d i n g ERAcare Candela Distribution (1) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing reading lamp only. Report No.: ITL60755 Model No.: ECT5HO Efficiency: 74.8% 1300 90 75 60 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Reading Illumination Level (45 Plane, 47 AFF) Recommended Level* 20-50 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 ERAcare 54** 2600 45 * Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities ** Achieved utilizing the reading optical compartment with (1) F54 T5HO lamp. 3900 0 15 30 LEGEND: 0-deg: 45-deg: 90-deg: Patient Room View Detail of Angled Reading Surface 49.96 52.88 53.41 Angled Reading Surface 58.31 53.96 59.03 51.25 55.87 48.54 53.16 9
P ro d u c t S p e c i f i c a t i o n s Luminaire Construction The exterior housing consists of an extruded aluminum body and die cast end caps. The back plate and ballast tray are formed from 18 gauge galvanized steel. Finish ERAcare can be specified in one of four standard polyester powder-coat paint finishes white, taupe, aluminum or almond. Custom finishes are available upon request. A color chip, to match, needs to be provided by the customer. All standard finishes have an antimicrobial additive to inhibit the growth of microbes. Reflectors ERAcare has four separate and unique reflectors roll-formed from specular aluminum. Lens The top ambient lens (top surface) and the front exam lens are both extruded acrylic with DR additive for flexibility over the life of the product. The bottom exam/reading lens is extruded from acrylic. Internal linear prisms help maintain a smooth exterior surface. Removable extruded aluminum socket covers are provided at the ends of each aperture opening to conceal the lamp socket and to create a more uniform appearance across the illuminated lens surface. Lamps ERAcare can be specified with either F54 T5HO, F28 T5 or F32 T8 linear fluorescent lamps. Philips Alto, low mercury lamps are supplied with the luminaire. 3500K is the standard color temperature but alternative color temperatures can be specified. ECO-FRIENDLY Switching The standard switching configuration is an on/off pull cord for the reading compartment with the ambient and exam compartments controlled from a remote wall switch (by others). An optional 4-position pull cord switch (HDS) for sequential control of the ambient and reading compartments is available. The exam function is controlled from a remote wall switch. Pull switches are supplied with a plastic pull cord that is latexfree, stain-resistant, and easy to clean with standard disinfectant. An optional low voltage relay (LVC), that is compatible with industry standard bed control systems (by others), can be field wired for either separate or sequential switching of the ambient and reading compartments. ERAcare can also be specified less switch (LS) with remote switching (by others) controlling all functions. Electrical Electronic high power factor ballasts, rated for 120 and 277 volts, are used. 347 volt ballasts available for T8 lamps only. Ballasts are thermally protected and have a Class A sound rating. T5 and T5HO ballasts have end-of-life protection. Listing UL and CUL Listed. ERAcare is also IBEW labeled. Agion antimicrobial has been listed with the U.S. Food and Drug Administration (FDA), certified by the National Sanitation Foundation (NSF) and registered with the U.S. Environmental Protection Agency (EPA). Installation The back plate is mounted over the electrical junction box or to electrical wiring whip and secured to the wall structure. The housing hooks onto the back plate and is secured with two screws. Lamp replacement is performed by removing the lens and one socket cover. Warranty Limited lifetime warranty on materials and workmanship. Standard manufacturers warranty applies on lamps and ballasts. 1 0
D i m e n s i o n a l D a t a 8-15/16 (227.3mm) 5-1/2 (139.7mm) Side View Front View 38 (965.2mm) 24 (609.6mm) D A B Cross Section A. Ambient lamp compartment B. Reading lamp compartment C. Exam lamp compartment D. Rear Exam lamp compartment C Back View 16 (406.4mm) ECT5HO ECT5 ECT8 48-15/16 (1243.1mm) 48-15/16 (1243.1mm) 50-7/8 (1292.22mm) 5-1/2 (139.7mm) O r d e r i n g I n f o r m a t i o n Sample Catalog No: ECT5HO - 277 - SWH - HDS - NL NOM. LENGTH Model Number Voltage Finish (standard color is SWH) ECT5HO (4) F54 T5HO (Med. Bipin) 120 277 SWH Soft White 4 ECT5 (4) F28 T5 (Med. Bipin) 347 1 TPE Taupe AL Aluminum ECT8 (4) F32 T8 (Med. Bipin) ALM Almond CC 2 Custom Color 1 347v available for ECT8 only. 2 Customer to provide color chip to match. 3 Not available for 347v applications. 4 Not available with EM1 option. Options HDS 4-position pull cord switch for sequential control of ambient and reading compartments (120v only) LVC 3,4 Low voltage controller LS Less switch EM1 3 Emergency ballast NL 3 LED night/chart light w/dual 3-position rocker switches (120v and 277v) NL-W 3 LED night/chart light (remote switch by others), (120v and 277v) SBF Slow blow fuse BSS 3 Bed shut-off switch (120v and 277v) PC Replacement 6 plastic pull cord (non-latex) CO-W Grounded convenience outlet, white (120v only) Hg Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled Contains Mercury and/or with the symbol Hg. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org 1 1
2013 Koninklijke Philips N.V. (Royal Philips). All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires ERAcare 07/13 Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008