VI 3 - i TABLE OF CONTENTS

Similar documents
DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

KENYA ELECTRICITY GENERATING COMPANY LTD

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

TS RES - OUTSTANDING ISSUES

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

SECTION VI TECHNICAL SCHEDULES

Electrical Description

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

GENERAL TECHNICAL SPECIFICATION (Turnkey Work)

CEYLON ELECTRICITY BOARD SRI LANKA. Procurement of Plant

TABLE OF CONTENT

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Substation Preventive Maintenance

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

I -limiter The world s fastest switching device

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

SYNCHRONISING AND VOLTAGE SELECTION

EI HIGH VOLTAGE INSULATION TESTING POLICY

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

RELEVANT ELECTRICAL STANDARDS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

MINISTRY OF ELECTRICITY

ECP HV INSULATION TESTING

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

GENERAL TECHNICAL SPECIFICATION

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

ECP HV INSULATION TESTING

Distribution/Substation Transformer

SUPPLY OF CARRIER PROTECTION COUPLER TYPE NSD-50

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

ESB National Grid Transmission Planning Criteria

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

Chapter B Connection to the MV utility distribution network

Insulation Co-ordination For HVDC Station

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

General Requirements. Technical Specification LVAC Systems

NIC Project Medium Voltage Direct Current Link Technical Specification

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

50-SDMS-01 SPECIFICATIONS FOR

Gas-Insulated Medium-Voltage Switchgear siemens.com/8dab12

Draft Kenya Standard for Balloting Not to be Cited as Kenya Standard

N. TEST TEST DESCRIPTION

Embedded Generation Connection Application Form

Protection of Electrical Networks. Christophe Prévé

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Test description for dry-type transformers chapter for special tests

Residual Current Operated Circuit-Breakers (RCCBs)

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Hamdy Faramawy Senior Application Specialist ABB Sweden

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Wind Power Facility Technical Requirements CHANGE HISTORY

Australian Standard. Switchgear assemblies and ancillary equipment for alternating voltages above 1 kv AS

ELE-CMOS-E-2001 Electrical Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS TRAINING COURSES AND CERTIFICATIONS

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Operating Manual MU2000K

Report on investigation of failure of 315 MVA Auto transformer at 400 kv Bawana Substation of Delhi Transco Ltd.(DTL)

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Stabilized Differential Relay SPAD 346. Product Guide

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Table of Contents. Introduction... 1

N. TEST TEST DESCRIPTION

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

Electronic Circuit Breaker ESS20-0..

ELECTRICAL POWER ENGINEERING

EDS FAULT LEVELS

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

7. INSPECTION AND TEST PROCEDURES

Impact Assessment Generator Form

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Electronic Circuit Breaker with reset input ESS20-1..

I Pr I P I OUT R L. Applications. Standards

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Energy Division. Bowthorpe LV/MV Surge Arresters

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

Transcription:

VI 3 - i TABLE OF CONTENTS 3 PROJECT SPECIFIC DATA... 1 3.1 DEFINITIONS... 1 3.1.1 Design Data, High and Medium Voltage... 1 3.1.2 Design Data, Low Voltage Equipment... 2 3.1.3 Phase Relationship... 3 3.1.4 Colour Coding... 3 3.1.5 Environment... 3 3.1.6 Noise... 4 3.1.7 Auxiliary Power... 4 3.1.8 Electric Service During Construction... 4 3.1.9 220 V AC Un-interrupted supply (UPS)... 5 3.1.10 Operation and Control... 5 3.1.11 Interface between Contractors and towards Employer... 6

Kenya Power and Lighting Company VI 3-1 Contract A35 3 PROJECT SPECIFIC DATA 3.1 Definitions Whenever the following terms or words are found in the specifications and/or other documents, they shall have the following meaning: "High Voltage Equipment" (HV): Mostly used for equipment provided for a maximum operating voltage higher than 52.5 kv (generically also used for voltages down to 1000 V). "Medium Voltage Equipment" (MV): Equipment provided for a maximum operating voltage higher than 1000 V and up to 52.5 kv. "Low Voltage Equipment" (LV): Equipment provided for operation at 1000 V or below. (For transformers the term Low Voltage Winding is used for the side with lowest rated voltage regardless value) AC means Alternating Current, DC means Direct Current, Where protection degree IP xx is mentioned it shall generally be according to IEC 60529 Degree of Protection Provided by Enclosure. 3.1.1 Design Data, High and Medium Voltage The rating and design criteria for the HV and MV plant and equipment shall be as follows: Item Parameters SYSTEM VOLTAGE 132KV 66 kv 33kV 11 kv 1 System 50 Hz, 3 phase 2 Neutral point earthing Solid earthed 3 Nominal voltage of networks 132KV 66 kv 33 kv 11 kv 4 Highest system voltage as defined by IEC- 145KV 72.5 kv 36kV 12 kv 60038 5 Short circuit and earth fault current, 42KA 31.5 ka 25kA 25 ka symmetrical r.m.s. value (min breaking current) not less than 6 Thermal short-circuit current, 3 second not 42KA 31.5kA 25kA 25kA less than 7 Dynamic peak current (min making 80KA 80 ka 63kA 63 ka current)not less than 8 Rated current of busbars and bus coupler if 2500A 2500 A 1250A 1250 A not given in Scope of Works, for each individual substation 9 Minimum rated current of isolating switches 2000A 800 A 800A 630 A and circuit breakers if not given in Scope of Works 10 Insulation level according IEC 60071: 10a Switching surge withstand voltage Phase-to-earth N/A N/A N/A N/A Longitudinal impulse component of N/A N/A N/A N/A combined test 10b Lightning impulse withstand voltage (1.2/50 650KV 325 kv 170kV 75 kv m/s kv peak ) 10c Test voltage at power frequency 1 min dry 275KV 140 kv 70kV 28 kv

Kenya Power and Lighting Company VI 3-2 Contract A35 Item Parameters SYSTEM VOLTAGE 132KV 66 kv 33kV 11 kv and wet. To earth and between phases 11 For the design and erection of the conductors in the switchyard the following minimum distances shall be observed 11a Phase to earth [mm] 1300 700 500 500 11b Phase to phase [mm] 1600 790 435 250 11c Busbars phase to phase [mm] 3000 1250 11e Height to live parts above ground [mm] 5000 3500 2900 2900 11f Height to live parts above ground at transformer transport routes [mm] 6000 5500 12g Lowest part of insulators above ground 3500 2 500 [mm] 12 Maximum temperature rise of conductors 40 ºC above ambient temperature (40 ºC) 13 Maximum wind pressure on conductors and cylindrical objects 400 N/m 2 14 Maximum wind pressure on flat surfaces 820 N/m 2 15 Minimum nominal creepage distance as defined in IEC 60815, Table II Note 1) Ref IEC 60038) 25 mm/kv (inland area) 31 mm/kv (in coast and industrial area) Note 2) For all current carrying parts the permissible short circuit duration shall be at least 1 second. Indoor equipment shall be arch tested in accordance with IEC 60298 amendment 2. The dynamic or momentary short circuit current on which the equipment design shall be based shall be computed by multiplying the r.m.s. value of the symmetrical short circuit current by the factor 1.8 x 2. Note 3) Ref IEC 60071) High and Medium Voltage equipment shall be designed for installation at 2200 m above sea level in all areas, except areas below 700m that shall be designed for 1000m above sea level. IEC 60071 shall apply with the specified correction factor for the altitude above sea level. Note 4) The design data in the particular technical specifications takes precedence. 3.1.2 Design Data, Low Voltage Equipment Low voltage installation shall be in accordance with EMC directives. The rating and design criteria for low voltage equipment shall be as follows: AC Voltage Nominal system voltage 415/240 V -15%, +10% (+ or 6%), TN - CS System frequency 50 Hz ( + or 2%) DC System 110 V, & (48V for communication) Power frequency Test Voltage 1 min 2.5 kv Thermal rating of conductors 120 % of load Max short-circuit Current 25 ka AC LV equipment can, after the Project Manager s approval, be rated for lower short-circuit current if calculation demonstrates that lower values are applicable at

Kenya Power and Lighting Company VI 3-3 Contract A35 the place of installation. DC equipment shall be adapted to the actual values at sites as shown in calculations. 3.1.3 Phase Relationship The phase relations and designations shall be in accordance with the existing system of the Employer. The phase sequences will be made known to the Contractor at a later date, but not later than 1 month from date of commencement. The standard phase colours are Red, Yellow, Blue (RYB). 3.1.4 Colour Coding All wires must have ferrules at all terminations to distinguish each signal. In addition the wires shall have the following colours: Circuit Voltage transformers Current transformers A.C. Circuit D.C. Circuit Grounding circuit Colour of Wire Red Black Yellow Blue Green with yellow stripe 3.1.5 Environment (Following coloured ferrules shall be provided on each wire in order to identify phase and polarity. Phase and Polarity Colour of ferrules A.C. First phase Red Second phase Yellow Third phase Blue Neutral Black Grounded Green with yellow stripe Auxiliary DC Supply Positive Red Negative Black Ferruling system should be submitted to the Employer for approval before commencement of works. Unless otherwise specifically stated in Particular Technical Specifications or Scope of Works, any equipment, component and assembly shall be designed for the following service conditions: Parameter Max Min Ambient air temperature Outdoor +40 C -1 C Indoor +40 C -1 C 24 hour average maximum +30 C -1 C Ambient temperature for cables in the ground +40 C -1 C Relative humidity 90% Height above sea level 2200 m Below 1000m Cooling water temperature N/A N/A EMC Class (IEC 61000) Industrial environments

Kenya Power and Lighting Company VI 3-4 Contract A35 3.1.6 Noise Seismic coefficient 0.15 Wind pressure on project area 430 N/m² 383N/m 2 of conductors and cylindrical objects Maximum wind pressure on steel members 820 N/m² on 1.5 times projected area Rainfall conditions Average 800-1700 mm/year Maximum 160mm in 24 hrs Annual mean isokeraunic level Max 180 thunderstorm days Pollution (IEC 60815) Heavy :class II Wherever any of these maximum or 24 hour average temperatures exceed the normal service condition temperatures of the IEC Recommendations for the relevant equipment, or of such other standard which is approved to be applied, the permissible temperature rises of the IEC Recommendations or the standard shall be reduced by the same amount as the difference between the above figures and the normal service condition temperatures. The Contractor shall guarantee these reduced temperature rises. All air cooled equipment shall be cooled with convection (i.e. without fans) provided other cooling methods are not explicitly allowed for in the specifications. The equipment shall as far as possible not generate undue vibrations or bothersome noise. Provided nothing else is specified the following requirements shall not be exceeded: Machine hall, workshop etc. (one meter from the machine) max 85 db(a) Office, control room, day room etc. max 50 db(a) Emergency diesel generator (7 meter from engine room) max 85 db(a) 3.1.7 Auxiliary Power 3.1.8 Electric Service During Construction Metered electric supply at 415/240V, 3-phase, 50 Hz TN-S will be available at the substation sites. The contractor shall bear the cost of connection and associated monthly bills. All tools and equipment supplied by the Contractor shall be suitable for this supply system. The Employer, while endeavouring at all times to maintain the supply, can accept no responsibility for the consequences that may arise from the failure or cessation of the electric supply. 3.1.8.1 Power Supply On HV substations the power for the auxiliary service is in general supplied from the station transformers connected to the tertiary windings of the transformers whereas on MV substations the. Power is supplied from station transformers connected to the MV busbars. The system is shown in detail on the single-line diagrams enclosed in the drawing section and further specified in Scope of Work. Less important MV substations may take the auxiliary voltage from the general surrounding grid. Equipment needing uninterrupted supply shall be fed from permanently charged station batteries. If other voltage sources or voltage levels then given below, are required they shall be included in the Bid. Such voltages shall not be brought out of the cabinet where they are used.

Kenya Power and Lighting Company VI 3-5 Contract A35 All the substations shall have an automatic change over scheme for the 415V power supply sources at the substations. 3.1.8.2 AC Auxiliary Supply Components in the AC low voltage main distribution system shall have a voltage rating of 415/240 volts, 50 Hz. The system shall be 3-phase, the transformer neutral grounded (TN-CS) For lighting, small power socket outlets, domestic appliances and other small power, 230V shall be used. 16 A sockets shall be of the British Standard type with square pins. 3.1.8.3 DC Auxiliary Supply The DC auxiliary supply shall be (unless otherwise stated in Scope of Works): For control, protection and alarm circuits 110V-IT All bulbs and any voltage sensitive relays shall be rated 125/52 V. 3.1.9 220 V AC Un-interrupted supply (UPS) Not applicable 3.1.10 Operation and Control The operations, control procedures, monitoring and protective devices for the plants are described in Particular Technical Specifications. The Contractor shall take all measures and furnish all requirements necessary for effecting the intended method of operation and control. The station functional control shall be possible in a hierarchic structure as follows: Supervisory Control from a Supervisory Control and Data Acquisition (SCADA) System. The old system is outdated and a new will be established where 33 kv and below will be connected to Regional Control Centres (RCCs) in Mombasa. All equipment and stations to be refurbished under this project shall be prepared for normal day-to-day operation from these centres. The RCCs are subordinated to the National Control Centre (NCC). The station HV and LV switchgear shall be controlled from RCC. Indications shall be available both in NCC and RCC. Local Control from the local bay control unit, control panels and from the MV switchboards. If these contains full mimic and display functions the remote control can be omitted in MV panels. Direct Control/Emergency Control from the apparatus itself. The stations shall function without interruptions even if connection to higher levels fails. A local/remote switch shall be accommodated on each control position blocking remote operation but not indication. The position of this switch shall be indicated in the higher levels of operation. The control shall include operation of all circuit breakers and motorised disconnectors. Status indication shall be available in the supervisory system for all HV and MV breakers in the system as well as busbar voltages, line and transformer load in A (plus MW and MVAr). For on-load tap changers position indication and raising/lowering of the tap changer position shall be possible

Kenya Power and Lighting Company VI 3-6 Contract A35 supervisory and remotely. MV transformers may be equipped with automatic voltage control functions and manual override shall then only be possible if the automatic function is blocked locally. Relay trips and other relevant alarms shall also be transferred. Direct control of all station switchgear at the respective switchyards/panels shall be possible. Interlocking devices and automatic change-over systems shall be incorporated in the control circuits in the quantity needed to guarantee non-interruption and correct sequence of operation of the equipment. Protective devices shall be supplied in accordance with the Particular Technical Specifications, and the particular needs of such equipment furnished with the aim of ensuring a safe and reliable operation of the plants in the event of electrical and mechanical disturbances or in case of mal-operation by the plant personnel shall be taken into consideration. The signals and command to be transmitted are given in Particular Technical Specifications All equipment, instruments and devices in the substation necessary for supervisory, remote and local control as well as for protection, signalling and indication shall be included in the Bid and hence the Contract, it being understood so that the enumeration found in Scope of Works, in this respect is indicative but not limiting. 3.1.11 Interface between Contractors and towards Employer For substations to be extended, all connections shall be made and all equipment and drawings be provided by the Contractor to ensure proper operation of the complete plants, although this should not be specifically mentioned in the Scope of Works Section. The Employer will for such stations, supply to the Contractor within one month from the date of commencement all documentation available for adaptation to the existing plant. All equipment specified under the various lots within a plant. specified in the Particular Technical Specifications and Scope of Works shall constitute a complete and functioning system together with equipments covered by any other lot even if this lot is contracted by separate contractor. The Contractor shall pay special attention to the Power Transformers. All necessary equipment and connections required to form a complete working plant and not mentioned under the Power transformer shall be included in the switchgear contract whether or not specifically mentioned in these Particular Technical Specifications. The Contractor shall supply and execute all cable connections between the control room and the transformer marshalling boxes and cabinets as well as supply all AC power for motors and DC voltage for control, indication and alarm purpose. The Contractor shall also provide all necessary connections to the control system from other sources like voltage and current transformer terminals, etc. The Contractor shall connect the transformer to the grid and supply clamps for the transformer bushing. He shall also design and construct the transformer foundations based on Transformer Contractor's specifications and drawings and

Kenya Power and Lighting Company VI 3-7 Contract A35 supply and erect LV cables from auxiliary transformer terminals to the auxiliary voltage board. For the substations to be refurbished or extended the Contractor shall provide and make drawings of the cable connections from actuators, sensors, transducers and relays to the Distributed Control Units as well as all materials required. He shall also document the adaptation to the existing plant with complete circuit diagrams, cable lists etc including proper cross references. The Contractor shall connect the switchgear to the line landing span erected by the Line Contractor.