Effect of shoulders on bending moment capacity of round mortise and tenon joints

Similar documents
Withdrawal, shear, and bending moment capacities of round mortise and tenon timber framing joints

Exploratory study of high-strength, low-cost through-bolt with cross-pipe and nut connections for square and roundwood timber frame construction

Statistical Lower Tolerance Limits for Rectangular Mortise and Tenon Joints

Design and Testing of Environmentally Friendly Wooden School Chairs for Developing Countries

Withdrawal Strength of Staples

Static Front to Back Loading Capacity of Wood Chairs and Relationship between Chair Strength and Individual Joint Strength

THE EFFECT OF END DISTANCE AND NUMBER OF READY-TO- ASSEMBLE FURNITURE FASTENERS ON BENDING MOMENT RESISTANCE OF CORNER JOINTS.

Estimating Design Values for Two-Pin Moment Resisting Dowel Joints with Lower Tolerance Limit Approach

Performance tests of small barn frame constructed with round mortise and tenon joints

SIMPLIFIED DESIGN PROCEDURE FOR GLUED-LAMINATED BRIDGE DECKS

Screw Withdrawal A Means to Evaluate Densities of In-situ Wood Members

SCREW WITHDRAWAL RESISTANCE SHEET METAL SCREWS IN PARTICLEBOARD AND MEDIUM-DENSITY HARDBOARD

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

Combined stress analysis of mitered spline furniture joints under diagonal loading

TENSION STRENGTH OF FURNITURE MIDDLE JOINTS CONSTRUCTED WITH BISCUITS

EVALUATION OF METHODS OF ASSEMBLING PALLETS RESEARCH PAPER FPL U. S. DEPARTMENT OF AGRICULTURE FOREST SERVICE FOREST PRODUCTS LABORATORY

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

Dowel connections in laminated strand lumber

Building Constructed with Round Mortise and Tenon Joints from Salvage Materials and Small Diameter Timber

Lawrence A. Soltis. James K. Little

STRUCTURAL TIMBER DESIGN

ABSTRACT INTRODUCTION

COUCH ANALYSIS ARCH 614

EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS. G. Y. Jeong* J. H. Kong

DETERMINING THE BENDING AND TENSILE STRENGTH OF IMPREGNATED WITH RAPESEED OIL EUROPEAN BEECH (FAGUS SYLVATICA) WOOD JOINTS GLUED WITH

Effect of Tenon Size on Static Front to Back Loading Performance of Wooden Chairs in Comparison with Acceptable Design Loads

LATERAL LOADS OF STAPLED GLUED SURFACE-TO-SURFACE JOINTS IN ORIENTED STRANDBOARD FOR FURNITURE. Samet Demirel. Onder Tor. Xiaohong Yu* Jilei Zhang*

PERFORMANCE OF FASTENERS IN WOOD

Effect of PVAc Bonding on Finger-Joint Strength of Steamed and Unsteamed Beech Wood (Fagus sylvatica)

4.0 MECHANICAL TESTS. 4.2 Structural tests of cedar shingles

F'II'XURAI PROPERTIES. and DIiIENSIONAL STABILITIES of two ronsrsrfcions of 4 8inch,,l SOUTHERN PINE PIY WOOD. ris on m p o f I( F

Lateral Load-Bearing Capacity of Nailed Joints Based on the Yield Theory

STRENGTH OF GLUED LAMINATED SITKA SPRUCE MADE UP OF ROTARY-CUT VENEERS. R. F. LUXFORD, Senior Engineer

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

PROCEDURE FOR DESIGN OF GLUED-LAMINATED

Design Nailed and Wood Screwed Connections with Spreadsheet. Course Content

EVALUALUATION AND OPTIMIZATION OF BENDING MOMENT CAPACITY OF CORNER JOINTS WITH DIFFERENT BORING PLANS IN CABINET CONSTRUCTION

THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH

Trestle Table and Benches Materials List

Bending Moment Capacity of L-Shaped Mitered Frame Joints Constructed of MDF and Particleboard

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel

Development of Wooden Portal Frame Structures with Improved Columns

IMPROVING PAINT PERFORMANCE ON SOUTHERN PINE BY RELIEF OF MACHINING STRESSES AND CHROMIC ACID TREATMENT

Evaluation of the Partial Compressive Strength according to the Wood Grain Direction* 1

DESIGN CONSIDERATIONS FOR MORTISE AND TENON CONNECTIONS

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

Effect of finger length on fingerjoint strength in radiata pine

Nail and screw withdrawal strength of laminated veneer lumber made up hardwood and softwood layers

AMTS STANDARD WORKSHOP PRACTICE. Bond Design

The Location of the Neutral Axis in Wood Beams with Multiple Knots. An Abstract of the Thesis of

Space-frame connection for small-diameter round timber

TFEC Standard for Design of Timber Frame Structures and Commentary

PATTERN OF VARIATION OF FIBRIL ANGLE WITHIN ANNUAL RINGS OF PINUS ATTENURADIATA

Connection and Tension Member Design

EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS

Connection and performance of two-way CLT plates

RESEARCH ON WITHDRAWAL STRENGTH OF MORTISE AND TENON JOINT BY NUMERICAL AND ANALYTIC METHODS

Section Downloads. Lumber Design Values. Lumber Standard. Western Lumber Product Use Manual. Section 05: Truss Materials.

Timber Bridge Hardwood Glulam Deck Connector Evaluations under Static and Repetitive Loads

SHEAR STIFFNESS OF TWO-INCH WOOD DECKS FOR ROOF SYSTEMS U.S.D.A. FOREST

LOAD DURATION AND SEASONING EFFECTS ON MORTISE AND TENON JOINTS

Made from Visually Graded Hem-Fir Lumber

DESIGN AND TESTING OF LOW COST CHAIR WITH ROUND MORTISE AND TENON JOINTS

AN INNOVATIVE FEA METHODOLOGY FOR MODELING FASTENERS

DOWEL ACTION OF TITANIUM BARS CONNECTING MARBLE FRAGMENTS AT DIFFERENT ANGLES

PRACTICAL ENGINEERING. Strong Rail-Post Connections for Wooden Decks

Shear Capacity of Dowelled Mortise and Tenon in Tropical Timber

WITHDRAWAL AND LATERAL STRENGTH OF THREADED NAILS

B.L. Wills D.A. Bender S.G. Winistorfer 1

DESIGN EQUATION FOR MULTIPLE- FASTENER WOOD CONNECTIONS

Chapter 2 Basic Properties of Undervalued Hardwoods. John I. Zerbe Volunteer, USDA Forest Products Laboratory. Properties of Soft Maples

Strength of Material-I (CE-207)

MANDREL PENDING TESTS FOR AMMAR VENEER

Steady State Operating Curve

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Screw-holding, internal bond, and related properties of composite board products for furniture and cabinet manufacture: a survey of the literature

RlGIDITY AND STRENGTH OF WALL FRAMES BRACED WlTH METAL STRAPPING

FIFTH INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE INNOVATIONS IN FOREST INDUSTRY AND ENGINEERING DESIGN

PREDICTION OF INTERNAL BOND STRENGTH IN PARTICLEBOARD FROM SCREW WITHDRAWAL RESISTANCE MODELS

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Edgewise compressive strength of corrugated fiberboard using the Morris method (short column test)

Finite Element Analyses of Two Dimensional, Anisotropic Heat Transfer in Wood

Rejuvenate An Old Tinius Olsen Machine with Computer Data Acquisition Using Its Existing Hardware and LabVIEW

Simplified analysis of timber rivet connections

Delamination Due to Outdoor Exposure of Southern Yellow Pine Plywood

Glulam Connection Details

Dowel. Design. Performance-Based World of Concrete Official Show Issue. Lift-truck design changes require a new look at joint durability

LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

BENDING MOMENT CAPACITY OF L-TYPE FURNITURE CORNER JOINTS CONSTRUCTED OF PARTICLEBOARD PRODUCED FROM VINE PRUNING RESIDUES

Three-dimensional finite element analysis of the Japanese traditional post-and-beam connection

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

Joinery and Adhesives

Copyright WilkerDos.com Dining Table. Project Designed By April Wilkerson - Plan Created By Jay Bates (jayscustomcreations.

BENDING STRENGTH PROPERTIES OF SCARF JOINTED EUROPEAN SPRUCE WOOD (Picea excelsa) Sotirios Karastergiou and George Ntalos ABSTRACT

Evaluation of service life of jointed rails

Lesson 7 Slope-Intercept Formula

Transcription:

Effect of s on bending moment capacity of round mortise and tenon joints Carl Eckelman Yusuf Erdil Eva Haviarova Abstract Tests were conducted to determine the effect of close-fitting s on the bending moment capacity of round mortise and tenon joints. Results indicate that close-fitting s can substantially increase the strength of the joints and that useful estimates of the contribution of s to the bending moment capacity of round mortise and tenon joints may be obtained by means of the following expression: F s = 0.934 2w D 1.66 F ns where F s and F ns = bending moment capacities of joints with and without s, respectively (in-lb); w = distance from the longitudinal axis of the tenon to the lower edge of the stretcher (in); and D = diameter of the tenon (in). Simple working relationships between shifts in neutral axis, which result from the use of s, and bending moment capacity were not found. Close fits can be obtained through the use of somewhat complex relationships, but these were not judged useful for practical design purposes. Performance tests of furniture constructed with round mortise and tenon joints indicate that when the s on the tenons fit closely against the walls of the members in which the tenons are inserted, the s considerably increase the bending moment capacities of the joints. Knowledge about this behavior is important not only in estimating the expected performance of existing furniture but also in designing durable furniture to meet severe end-use requirements. Overall, these performance tests tend to indicate that for square members, the increased bending moment capacity of round mortise and tenon joints with s is functionally related to the ratio of W/D where D is the diameter of the tenon and W is the width of the member in the plane of the bending moment (hereafter referred to as a stretcher ). Presumably, these increases in strength are related to the shifting of the neutral axis of the tenon owing to loading of the along with a transition in the primary mode of loading of the tenon from bending to withdrawal. Because of the potential contribution of s to bending moment capacity, an exploratory study was undertaken in order to investigate the characteristics of the effect and, if possible, to develop a practical expression for estimating the bending moment capacity of round mortise and tenon joints with s. Results of the study are given below. Description of study In general, the study consisted of comparing the bending moment capacities of round mortise and tenon joints constructed with s with the bending moment capacities of comparable joints without s (Fig. 1). Overall, the study was divided into three parts, which were carried out consecutively. The first part of the study was conducted to investigate whether a regular relationship between width and bending moment capacity could be shown to exist. Hence, specimens for this limited study were constructed with only one tenon diameter but with several square stretcher widths. To reduce variability and allow one-on-one comparisons of the bending moment capacities of joints with and without The authors are, respectively, Professor, Dept. of Forestry and Natural Resources, Purdue Univ., West Lafayette, IN (eckelmac@ purdue.edu); Associate Professor of Wood Science and Furniture Design, Mugla Univ., Kotekli, Mugla, Turkey (yziya@mu.edu.tr); and Assistant Professor, Dept. of Forestry and Natural Resources, Purdue Univ. (ehaviar@purdue.edu). This paper was received for publication in August 2004. Article No. 9920. Forest Products Society Member. Forest Products Society 2006. Forest Prod. J. 56(1):82-86. 82 JANUARY 2006

Figure 2. Construction of matched joints with and without s. Figure 1. Illustration of tenons with (a) and without (b) s, and positions of internal moment arm (c) and (d). s, a tenon with a was cut on one end of each stretcher and a tenon without a on the other end (Fig. 2a). The tenon on one end of the stretcher was then used to construct a joint with a and the tenon on the other end a joint without a (Fig. 2b) to form a pair of matched joints. Based on a positive result in the first part of the study, the second part was conducted to find a general relationship between tenon diameter, width, and bending moment capacity. Hence, both stretcher cross sections and tenon diameters were varied in constructing sets of matched joints. The third part of the study was conducted to determine whether the expressions developed in the first two parts of the study could satisfactorily estimate the bending moment capacities of joints used in practical furniture constructions. To examine these relationships, stretcher to post joints (with s) were cut from surplus chairs remaining from other studies and tested to determine their bending moment capacity. Estimates of the bending moment capacities of the joints were then compared to the test results. Description of specimens In the first part of the study, 2-inch-long by 0.720-inchdiameter tenons were cut on both ends of yellow-poplar stretchers that measured 0.75, 0.875, 1.0, 1.125, and 1.25 inches square. Corresponding mortises were bored in yellowpoplar members (hereafter referred to as posts) that measured 1-1/2 inches square. Tenons with s were fully inserted into the mortises so that the s of the tenons fit snugly against the walls of the posts in which the tenons were embedded (Fig. 2). Tenons on the opposite ends of the stretchers were inserted into identical posts to a depth of 1-1/2 inches so that 1/2 inch separated the s of the tenons from the walls of the posts. All of the tenons fit snugly in the mortises. Walls of the mortises were thoroughly coated with a 40 percent solids content aliphatic resin adhesive. Five specimens with s and five specimens without s were prepared for each stretcher size; thus, 25 joints were constructed with s and 25 joints without. Average moisture content (MC) of the specimens was 9.8 percent. In the second part of the study, 0.5-, 0.625-, 0.75-, 0.875-, and 1-inch diameter tenons were cut on the ends of 1-, 1.25-, 1.5-, 1.75-, and 2-inch square stretchers, as in the first part of the study (Fig. 2). Five joints were constructed for each combination for a total of 125 and 125 non- joints. Posts were constructed of 1-1/2 by 1-1/2-inch yellowpoplar material. All joints were glued as above. MC averaged 10.5 percent. Each of the stretcher to post joints used in the third part of the study consisted of a stretcher and corresponding section of a front or back post cut from surplus chairs that had been used in other studies. Tenon diameters averaged 0.715 inch. Stretcher width ranged from 0.83 inch to 0.94 inch with an average of 0.899 inch and a standard deviation (SD) of 0.03 inch. Forty specimens had yellow-poplar (Liriodendron tulipifera) stretchers and 20 had red oak (Quercus rubra) stretchers; posts were constructed of loblolly pine (Pinus taeda). MC at time of test averaged 6.8 percent. Method of test Specimens were mounted for testing in a universal testing machine as shown in Figure 3. A moment arm of 8 inches was used in all tests. Fall-off of peak machine load was used as the indicator of joint failure. Ultimate bending moment capacity was adjusted to account for the added moment resulting from weight of the stretcher and unsupported post. MC specimens were cut from the stretchers and weighed immediately after each test. Results and discussion Linear representations of the results from the first part of the study are presented in Figure 4. In this graph, the middle curve represents the bending moment capacities of the joints with s, the lower curve the capacities of joints without s, and the upper curve the values of the lower curve multiplied by W/0.72 where W refers to the width of the stretcher and 0.72 is the diameter of the tenon. The near parallel paths of the upper and middle curves indicated that simple useful relationships might exist, and that these could be used to estimate the contribution of a given to the bending capacity of a joint. Results of the second part of the study are given in Table 1. A regression expression of the form F NS = a D b (where F NS = bending moment capacity of joints without s [inlb]; D = diameter of the tenon [in]), was fitted to the results for the tenons without s in order to obtain a functional relationship between bending moment capacity and tenon diameter. The regression expression, F NS = 1197 D 2.80, was FOREST PRODUCTS JOURNAL VOL. 56, NO. 1 83

Figure 3. Test set up used to evaluate bending moment capacity of joints. Figure 4. Linear representations of capacities of joints with 0.72-inch tenons, both with and without s; and values of (W/0.72) (without ). obtained with an r 2 value of 98.8 percent. Values estimated by this expression are shown as the bottom solid line in Figure 5. Regression expressions of the form: F S = a 2w D b F NS were fitted to the individual data sets for tenons with s for each stretcher width to allow for visual interpretation of the data. In this expression, w = distance from the longitudinal axis of the tenon to the lower edge of the stretcher (as shown in Figure 2, w = W/2); F S = bending moment capacity of the joints with s; and a and b = regression coefficients. Regression coefficients for these curves are given in Table 2, and plots of the values estimated by the expressions are shown in Figure 5. The regular increase in bending moment capacity of the tenons with s can be seen clearly in this figure, both with respect to tenon diameter and stretcher width. This expression also was fitted to the combined test data for all stretcher widths. The expression: F S = 0.934 2w D 1.66 F NS [1] resulted, with r 2 equal to 97.44 percent. Plots of the values estimated with this expression are shown superimposed on the previous curves in Figure 5. Finally, the above expression was fitted to the test results for the 1-inch stretcher widths alone with the regression coefficient, b, set equal to 1. The simplified expression: F S = 1.08 2w D F NS [2] was obtained, with r 2 equal to 99.95 percent. Values estimated by this expression also are shown plotted in Figure 5.Ascan be seen, these values essentially coincide with those estimated by Equation [1] for 1-inch stretchers. This specific expression was developed because it is particularly useful in treating the smaller size members commonly used as chair stretchers. It also clearly demonstrates the value of s on tenons in chair stretchers. A 1-inch stretcher with s, for example, with a 0.72-inch-diameter tenon, would have 1.08 1.0/0.72, or, 150 percent of the capacity of a similar joint without s. Average bending moment capacity of the yellow-poplar joints cut from chair frames was 713 in-lb with an SD of 109 in-lb; comparable values for the red oak joints were 906 in-lb and 65 in-lb, respectively. On average, Equation [2] overpredicted the bending capacity of the yellow-poplar joints by 1 percent and the red oak joints by 5 percent. Average for the pooled data was 1.02 percent. Tenon withdrawal internal moment arm As illustrated in Figures 1c and 1d, it appears reasonable to assume that as the width of the increases, the bending moment capacity, F s, of the joint increasingly becomes a function of the withdrawal resistance of the tenon, T, multiplied by an internal moment arm, j, i.e.: F S = T j where T = withdrawal resistance of the tenon loaded in tension (lb); j = internal moment arm measured between the longitudinal axis of the tenon and the internal resultant compressive force, C (in). An expression of this form has been shown to reliably estimate the in-plane bending moment capacity of conventional dowel joints (Eckelman 1971), but its applicability to tenons with s has not been investigated. The withdrawal resistances of the tenons could not be determined by test without destroying the joints. Thus, withdrawal capacities were estimated by means of an expression (Eckelman 1969) developed to estimate the withdrawal capacities of dowels: T = 0.834DL 0.89 0.95S 1 + S 2 A where T = withdrawal capacity (lb); L = depth of embedment of the tenon in the mortise (in); S 1 = shear strength of the post in which the tenon is embedded (psi); S 2 = shear strength of the tenon (psi); A = combined adhesive/dowel-hole clearance factor. Based on previous research, a value of 0.83 can be assumed for A when close-fitting joints are assembled with at least a 42 percent solids PVA adhesive. When an expression of the form: F S = a w T was fitted to the test results for tenons with s along with the corresponding estimated withdrawal capacities of the tenons, the following expression resulted: 84 JANUARY 2006

Table 1. Average bending moment capacities of joints with five tenon diameters by five member widths, with and without s. Tenon diameter (in) Member cross section 1 in 1.25 in 1.5 in 1.75 in 2 in All -----------------------------------------------------------(in-lb)--------------------------------------------------------------- 0.5 362 172 580 180 733 176 918 167 1,098 167 172 0.625 548 322 778 329 955 325 1,161 315 1,368 315 321 0.75 768 537 990 540 1,186 539 1,407 531 1,638 529 535 0.875 1,023 827 1,214 821 1,423 825 1,655 825 1,906 820 824 1 1,310 1,203 1,448 1,180 1,667 1,193 1,905 1,208 2,174 1,199 1,197 Table 2. Regression analyses of data for 0.5-, 0.625-, 0.75-, 0.875-, and 1.0-inch-diameter tenons. a Range of Regression coefficients Correlation coefficients member widths a b r 2 (in) (%) 1 1.082 1.0 99.99 1 1.089 0.952 100.00 1.25 0.982 1.396 100.0 1.5 0.931 1.580 100.0 1.75 0.901 1.805 100.0 2.0 0.907 1.858 100.0 1 to 2 0.934 1.656 97.44 a Regression expression: F s = a 2w D F b NS Figure 5. Bending moment capacities of 0.5-, 0.625-, 0.75-, 0.875-, and 1-inch tenons with s on 1-, 1.25-, 1.5-, 1.75-, and 2-inch stretchers. Coefficients for the top expression are given in Table 2. F S = 0.894 w T [3] with r 2 equal to 89.0 percent. Estimated bending moment capacities for the various tenon-diameter vs. stretcher-width combinations, based on Equation [3], along with the corresponding values for tenons with s (previously shown in Fig. 5) are plotted in Figure 6. As can be seen, estimates of bending moment capacities for the larger member widths agree relatively closely with test values, whereas estimates for smaller widths differ considerably. It should be noted that the vertical positions of the estimates shown in Figure 6 depend upon the calculated tenon withdrawal values so that their true vertical positions, which depend on the correctness of the withdrawal values, could differ from those shown. Nonetheless, the slopes of the curves for the larger stretcher widths do not differ greatly from those for the curves fitted to the test data. Thus, it appears that the relationship itself is valid for tenons with wide s but is dependent on valid estimates of tenon withdrawal capacities. Bending moment capacity of tenons without s Presumably, the bending moment capacities of the tenons themselves may be estimated by means of the following form of the flexure formula: F NS = 1.18 D 3 32 s 4 where s 4 = modulus of rupture (MOR) of the wood of which the tenon is constructed (psi); 1.18 = form factor for round beams (Wangaard 1950). It is interesting to note that when an expression of the form F NS = a D b was fitted to the results for tenons without s, a power coefficient of 2.8 was obtained compared to the classical value of 3 used in the flexure formula above. The MC of the yellow-poplar wood was 10.5 percent so that the MOR of the wood (FPL 1999) amounted to 10,706 psi. The corresponding calculated bending strengths of the 0.5-, 0.625-, 0.75-, 0.875- and 1-inch diameter tenons amount to 155, 303, 523, 831, and 1,240 in-lb, respectively. The overall ratio of the corresponding test values divided by these values amounts to 1.02. This result tends to indicate that the form factor of 1.18 may be used in estimating the bending moment capacity of round tenons (Newlin and Trayer 1924, Wolfe et al. 2001). Conclusions Results of the tests indicate that useful estimates of the contribution of s to the bending moment capacity of FOREST PRODUCTS JOURNAL VOL. 56, NO. 1 85

F S = 0.894 w T where T = withdrawal strength of the tenon loaded in tension (lb). Although this expression yields close estimates, the accuracy of the estimates depends upon knowledge of the quality of the adhesive bonds between the walls of the tenon and mortise. Furthermore, this expression is best-suited for joints with small tenons and large s. Simple working relationships between shifts in the neutral axis, which result from the use of s, and bending moment capacity, were not found. Close fits can be obtained through the use of somewhat complex relationships, but these were not judged useful for practical design purposes. On average, results of the tests tended to indicate that the bending moment capacity of tenons without s may be estimated by means of the following form of the flexure formula: Figure 6. Tenon withdrawal internal moment arm values shown as dashed lines; regression curves of test results are shown as solid lines. round mortise and tenon joints may be obtained by means of the expression: F S = 0.934 2w D F 1.66 NS where F S and F NS = bending moment capacities of joints with and without s, respectively (in-lb); w = distance from the longitudinal axis of the tenon to the lower edge of the stretcher (in); D = diameter of the tenon (in). Results also show that the bending moment capacity of round mortise and tenon joints with s may be estimated by means of the expression: F NS = 1.18 D 3 32 s 4 where the constant, 1.18, is a form factor used with round beams. This relationship did not hold uniformly for all tenon diameters, however. Hence, questions remain whether the form factor used for round beams can be used with round tenons in mortise and tenon joints. Literature cited Eckelman, C.A. 1969. Engineering concepts of single-pin dowel joint design. Forest Prod. J. 19(12):52-60.. 1971. Bending strength and moment rotation characteristics of two-pin moment-resisting dowel joints. Forest Prod. J. 21(3): 35-39. Newlin, J.A. and G.W. Trayer. 1924. The influence of the form of a wooden beam on its stiffness and strength, II. Form factors of beams subjected to transverse loading only. Tech. Rept. 181, Reprinted. U.S. National Advisory Committee for Aeronautics Ann. Rept. 9. pp. 375-393. USDA Forest Service, Forest Products Laboratory (FPL). 1999. Wood Handbook: Wood as an Engineering Material. Forest Prod. Soc., Madison, WI. Wangaard, F.F. 1950. The Mechanical Properties of Wood. John Wiley and Sons, New York. 377 pp. Wolfe, R.W., J. Bodig, and P.K. Lebow. 2001. Derivation of nominal strength for wood utility poles. Gen. Tech. Rept. FPL-GTR-128. USDA Forest Serv., Forest Prod. Lab., Madison, WI. 11 pp. 86 JANUARY 2006