Load Frequency Control of Three Different Area Interconnected Power Station using Pi Controller

Similar documents
AUTOMATIC GENERATION CONTROL OF REHEAT THERMAL GENERATING UNIT THROUGH CONVENTIONAL AND INTELLIGENT TECHNIQUE

Automatic Generation Control of Two Area using Fuzzy Logic Controller

International Journal of Scientific & Engineering Research, Volume 6, Issue 6, June-2015 ISSN

Artificial Intelligent and meta-heuristic Control Based DFIG model Considered Load Frequency Control for Multi-Area Power System

LFC in hydro thermal System Using Conventional and Fuzzy Logic Controller

Load Frequency and Voltage Control of Two Area Interconnected Power System using PID Controller. Kavita Goswami 1 and Lata Mishra 2

Automatic Generation Control of Three Area Power Systems Using Ann Controllers

TWO AREA CONTROL OF AGC USING PI & PID CONTROL BY FUZZY LOGIC

AGC in Five Area Interconnected Power System of Thermal Generating Unit Through Fuzzy Controller

Improvement in Dynamic Response of Interconnected Hydrothermal System Using Fuzzy Controller

An intelligent fuzzy logic controller applied to multi-area load frequency control

Governor with dynamics: Gg(s)= 1 Turbine with dynamics: Gt(s) = 1 Load and machine with dynamics: Gp(s) = 1

Automatic Load Frequency Control of Two Area Power System Using Proportional Integral Derivative Tuning Through Internal Model Control

NEURAL NETWORK BASED LOAD FREQUENCY CONTROL FOR RESTRUCTURING POWER INDUSTRY

AUTOMATIC VOLTAGE REGULATOR AND AUTOMATIC LOAD FREQUENCY CONTROL IN TWO-AREA POWER SYSTEM

Load Frequency Control of Multi-Area Power Systems Using PI, PID, and Fuzzy Logic Controlling Techniques

CHAPTER 4 LOAD FREQUENCY CONTROL OF INTERCONNECTED HYDRO-THERMAL SYSTEM

Load frequency control in Single area with traditional Ziegler-Nichols PID Tuning controller

1. Governor with dynamics: Gg(s)= 1 2. Turbine with dynamics: Gt(s) = 1 3. Load and machine with dynamics: Gp(s) = 1

Stability Control of an Interconnected Power System Using PID Controller

CHAPTER 1 INTRODUCTION

ROBUST TECHNIQUE LFC OF TWO-AREA POWER SYSTEM WITH DYNAMIC PERFORMANCE OF COMBINED SMES AND SSSC CONTROL

Load Frequency Control of Interconnected Hydro-Thermal Power System Using Fuzzy and Conventional PI Controller

Automatic Generation control of interconnected hydrothermal power plant Using classical and soft computing Technique

Performance Analysis of PSO Optimized Fuzzy PI/PID Controller for a Interconnected Power System

Automatic load frequency control of Three-area power System using ANN controller with Parallel Ac/Dc Link

ADVANCES in NATURAL and APPLIED SCIENCES

Load Frequency Control in an Interconnected Hydro Hydro Power System with Superconducting Magnetic Energy Storage Units

Optimal PID Tuning for AGC system using Adaptive Tabu Search

LOAD FREQUENCY CONTROL FOR TWO AREA POWER SYSTEM USING DIFFERENT CONTROLLERS

Load Frequency Control of Multi-Area Power System with PI Controller

Performance Analysis of Conventional Controllers for Automatic Voltage Regulator (AVR)

Design of PI Controller using MPRS Method for Automatic Generation Control of Hydropower System

Load Frequency Control of Multi Area Hybrid Power System Using Intelligent Controller Based on Fuzzy Logic

SSRG International Journal of Electrical and Electronics Engineering ( SSRG IJEEE ) Volume 3 Issue 1 January 2016

International Journal of Advance Engineering and Research Development. Fuzzy Logic Based Automatic Generation Control of Interconnected Power System

COMPUTATION OF STABILIZING PI/PID CONTROLLER FOR LOAD FREQUENCY CONTROL

Control of Load Frequency of Power System by PID Controller using PSO

Automatic load frequency control of multi-area power system using ANN controller and Genetic algorithm

The Effect of Fuzzy Logic Controller on Power System Stability; a Comparison between Fuzzy Logic Gain Scheduling PID and Conventional PID Controller

A new approach for Tuning of PID Load Frequency Controller of an Interconnected Power System

Load Frequency Control of Three Area System using FOPID Controller

Design Of PID Controller In Automatic Voltage Regulator (AVR) System Using PSO Technique

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Modeling and Simulation of Load Frequency Control for Three Area Power System Using Proportional Integral Derivative (PID) Controller

Automatic Voltage Control For Power System Stability Using Pid And Fuzzy Logic Controller

AUTOMATIC GENERATION CONTROL OF INTERCONNECTED POWER SYSTEM WITH THE DIVERSE SOURCES USING SUPERCONDUCTING MAGNETIC ENERGY STORAGE (SMES)

International Journal of Advance Engineering and Research Development

MATLAB Simulink Based Load Frequency Control Using Conventional Techniques

Simulation and Analysis of Cascaded PID Controller Design for Boiler Pressure Control System

Frequency Control of Smart Grid - A MATLAB/SIMULINK Approach

Comparative Analysis Between Fuzzy and PID Control for Load Frequency Controlled Power

Design of GA Tuned Two-degree Freedom of PID Controller for an Interconnected Three Area Automatic Generation Control System

Effect of Non-linearities in Fuzzy Based Load Frequency Control

Tuning of PID Controller in Multi Area Interconnected Power System Using Particle Swarm Optimization

Load Frequency Controller Design for Interconnected Electric Power System

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

6545(Print), ISSN (Online) Volume 4, Issue 1, January- February (2013), IAEME & TECHNOLOGY (IJEET)

LOAD FREQUENCY CONTROL OF POWER SYSTEM

Load frequency control of interconnected system

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Performance Improvement Of AGC By ANFIS

Experiment 9. PID Controller

Transient Stability Improvement Of LFC And AVR Using Bacteria Foraging Optimization Algorithm

[Jahangir* et al., 5.(6): June, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Design of Compensator for Dynamical System

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

Review Paper on Comparison of various PID Controllers Tuning Methodologies for Heat Exchanger Model

LOAD FREQUENCY CONTROL FOR A TWO-AREA INTERCONNECTED POWER SYSTEM BY USING SLIDING MODE CONTROLLER

Design of an Intelligent Pressure Control System Based on the Fuzzy Self-tuning PID Controller

Indirect Vector Control of Induction Motor Using Pi Speed Controller and Neural Networks

An Implementation for Comparison of Various PID Controllers Tuning Methodologies for Heat Exchanger Model

PERFORMANCE COMPARISON OF POWER SYSTEM STABILIZER WITH AND WITHOUT FACTS DEVICE

CHAPTER 5 PSO AND ACO BASED PID CONTROLLER

Cohen-coon PID Tuning Method; A Better Option to Ziegler Nichols-PID Tuning Method

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

EE 742 Chapter 9: Frequency Stability and Control. Fall 2011

Comparative Study of PID and FOPID Controller Response for Automatic Voltage Regulation

Design of LFC and AVR for Single Area Power System with PID Controller Tuning By BFO and Ziegler Methods

Design of PI controller for Positive Output Super- Lift LUO Converter

INTEGRATED PID BASED INTELLIGENT CONTROL FOR THREE TANK SYSTEM

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Lecture 15 EMS Application II Automatic Generation Contol. Davood Babazadeh

ANALYSIS OF V/f CONTROL OF INDUCTION MOTOR USING CONVENTIONAL CONTROLLERS AND FUZZY LOGIC CONTROLLER

Comparison of Adaptive Neuro-Fuzzy based PSS and SSSC Controllers for Enhancing Power System Oscillation Damping

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Relay Feedback based PID Controller for Nonlinear Process

Design of Self-Tuning Fuzzy PI controller in LABVIEW for Control of a Real Time Process

Automatic Generation Control of an Interconnected Hydro-Thermal System Using Fuzzy Logic and Conventional Controller

A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators Under Test Contribute to Whole System Stability

Comparison Effectiveness of PID, Self-Tuning and Fuzzy Logic Controller in Heat Exchanger

ADVANCED DC-DC CONVERTER CONTROLLED SPEED REGULATION OF INDUCTION MOTOR USING PI CONTROLLER

Fuzzy Logic Controller on DC/DC Boost Converter

Fuzzy Adapting PID Based Boiler Drum Water Level Controller

Design and Implementation of Self-Tuning Fuzzy-PID Controller for Process Liquid Level Control

Comparative Analysis of Air Conditioning System Using PID and Neural Network Controller

Chapter 10: Compensation of Power Transmission Systems

Transcription:

Load Frequency Control of Three Different Area Interconnected Power Station using Pi Controller 1 Mr Tejas Gandhi, Prof. JugalLotiya M.Tech Student, Electrical EngineeringDepartment, Indus University, Ahmedabad, Gujarat,India Assistant Professor, Electrical Engineering Department, Indus University, Ahmedabad, Gujarat,India Abstract : This paper present analysis on dynamic performance of Load Frequency Control (LFC) of three area interconnected thermal-hudro-nuclear power station by the use of PI Controller. In this paper area-1, area-2 and area-3 consists of hydro, nuclear power plants whereas area-3 consists of thermal power plant. In this proposed scheme, the combination of most complicated system like thermal, hydro plant and nuclear plant are interconnected which increases the nonlinearity of the system. The performances of the controllers are simulated using MATLAB/SIMULINK package. The simulation results also tabulated as a comparative performance in view of frequency deviation by three different interconnected power plants. Keywords: Load Frequency Control (LFC), Tie line Control, PI controller, MATLAB / SIMULINK. I. INTRODUCTION Automatic Load Frequency Control (ALFC) is a very important issue in power system operation and control for supplying sufficient and reliable electric power with good quality. ALFC is a feedback control system adjusting a generator output power to remain defined frequency[1]. The interconnected power system is divided into three control areas, all generators are assumed to form a coherent group (Grass Getal, 2001). Load Frequency Control (LFC) is being used for several years as part of the Automatic Generation Control (AGC) scheme in electric power systems[3.4]. One of the objectives of AGC is to maintain the system frequency at nominal value (50 hz). In the steady state operation of power system, the load demand is increased or decreased in the form of Kinetic Energy stored in generator prime mover set, which results the variation of speed and frequency accordingly. Therefore, the control of load frequency is essential to have safe operation of the power system [6] A control strategy is needed that not only maintains constancy of frequency and desired tiepower flow but also achieves zero steady state error and inadvertent interchange. Among the various types of load frequency controllers, the most widely employed is the conventional proportional integral (PI) controller. The PI controller is very simple for implementation and gives better dynamic response. In LFC pertains to interconnected system and relatively lesser attention has been devoted to the LFC of three area interconnected hydro-thermalnuclear system[3]. The PI controller offers better performance especially, in complex and nonlinearities associated system. In this paper, the performance evaluation based on PI controller for three area interconnected thermal-hydro-nuclear power plant is proposed [4]. II. MODELLING OF THREE DIFFERENT AREA INTERCONNECTED WITH TIE LINE CONTROL To illustrate LFC system behavior in a multi-area power system, consider three different interconnected control areas as shown in Figure.1. The system dynamics response following a simulations 0.01 pu load step disturbance in control areas[8]. If disturbance is given to any one of the three areas, the power to compensate the tie-line power change initially comes from all the three areas and frequency drops in all the areas and this drop of frequency is sensed by the speed governors of the three areas. However, after a few seconds (steady state), additional power against the local load changes come only from that disturbed area[10]. Figure.1 Representation of Interconnected Three Different Area with Tie line In real time power system many loads are connected to many generators located in different regions (areas). This may be assumed as extended ISSN: 2348 8379 www.internationaljournalssrg.org Page 10

power system which can be divided into number of load frequency control areas interconnected by means of tie lines sin these areas load changes and abnormal conditions lead to mismatches in frequency and scheduled power interchanges through tie line between areas. These mismatches have to be corrected by Governor Control, which is defined as the regulation of the power output of generators within a prescribed area. The key assumptions in the classical Governor Control problem are: i. The steady state frequency error following a step load change should vanish. The transient frequency and time errors should be reduced. ii. The static change in the tie line power following a step load in any area should be zero, provided each area can accommodate its own load change. iii. Any area in need of power during an emergency should be assisted from other areas. Where (5) T ij -Tie line power between i th andj th areas. f i - Frequency of i th area. So the total tie line power change between area 1 and the other two areas can be calculated as (6) Similarly for N control areas, the total tie line power change between area 1 and other area is (as shown in Figure.2) The power transfer equation through tie line is, (1) Considering area 1 has surplus power and transfers to area 2 P 12 = Power transferred from area 1 to 2 through tie line. (2) Where δ 1, δ 2 andδ 3 = Power angles of end voltages V 1, V 2 and V 3 of equivalent machine of the three areas respectively. X 12 = reactance of tie line. shown in Figure 3. The order of the subscripts indicates that the tie line power is define positive in direction 1 to 2. For small deviation in the anglesand the tie line power changes with the amount i.e. small deviation in δ 1, δ 2 and δ 3 changes by δ1, δ2, and δ 3 Power P12 changes to P12 + P 12. Therefore, Power transferred from Area 1 to Area 2 as given in [10]] is Change in the tie line power between area 1 and 2 (7) Figure.2 Block Diagram Representation for tie-line Power Change of Control Area i in N Control Area Power System Therefore three area system can be modeled as (3) Change in the tie line power between area 1 and 3 (4) Change in the tie line power between area 2 and 3 ISSN: 2348 8379 www.internationaljournalssrg.org Page 11

high frequency response[15]. The integral term insures that the average error is driven to zero. Advantages of PI include that only two gains must be tuned, that there is no long-term error, and that the method normally provides highly responsive systems. The predominant weakness is that PI controllers often produce excessive overshoot to a step command. The PI controller is characterized by the transfer function (8) A. Proportional Gain (K p ) Larger values typically mean faster response since the larger the error, the larger the Proportional term compensation. An excessively large proportional gain will lead to process instability and oscillation. B. Integral Gain (K i ) Larger values imply steady state errors are eliminated more quickly. The trade-off is larger overshoot: any negative error integrated during transient response must be integrated away by positive error before we reach steady state. Figure 3. Simulink Model of Interconnected Three Different Area with Tie line Control III. PI CONTROL METHODOLOGY Most common controllers available commercially are the proportional integral (PI) and proportional integral derivative (PID) controller [13]. The PI controllers are used to improve the dynamic response as well as to reduce or eliminate the steady state error [14]. The derivative controller adds a finite zero to the open loop plant transfer function and improves the transient response. PI is made up of two main components i.e. proportional and integral. The PI controller is a lag compensator. It possesses a zero at s = -1/T i and a pole at s = 0. Thus, the characteristic of the PI controller is infinite gain at zero frequency. This improves the steady-state characteristics [12]. However, inclusion of the PI control action in the system increases the type number of the compensated system by 1, and this causes the compensated system to be less stable or even makes the system unstable. Therefore, the values of K p and T i must be chosen carefully to ensure a proper transient response. By properly designing the PI controller, it is possible to make the transient response to a step input exhibit relatively small or no overshoot. The speed of response, however, becomes much slower [16]. IV. SIMULATION AND RESULTS A three area system model is developed for multi-area concept. In three area system hydro system is taken as area 1 and nuclear system is taken as area 2 and thermal system is taken as area 3. This three area system is simulated for 1% disturbance in thermal system. This three area system is modeled without nonlinearities [15]. The performance offrequency deviation using PI controller is tested and compared for three area system. A three area Hydro-Nuclear-Thermal system is shown in Figure 5 [16]. Simulated and compared frequency responses of three different power plants are shown in Figure-6 to 9. Table. I show that performs frequency deviation using PI controller for different three areas. Figure 4: Block Diagram of a PI Controller. This controller is one of the most popular in industry. The proportional gain provides stability and ISSN: 2348 8379 www.internationaljournalssrg.org Page 12

A. Simulation of Three Different Interconnected Power Plant B. Analysis of Three Different Interconnected Power Plant Fig.6 Frequency Deviation for Hydro PS Fig. 5 Simulation on Three Different Area Interconnected Hydro-Nuclear-Thermal Power Station using PI Controllers Fig.7 Frequency Deviation for Nuclear PS Fig.8 Frequency Deviation for Thermal PS ISSN: 2348 8379 www.internationaljournalssrg.org Page 13

Fig.9 Frequency Deviation for Three Combined PS C. Tables Sr. Three Different Stations Frequency Deviation Δf No. 1 Hydro Power Station -0.022 Hz 2 Nuclear Power Station -0.012 Hz 3 Thermal Power Station -0.023 Hz Table I Results of Frequency Deviation for Three Different Power Plants V. CONCLUSION In this paper three different area thermal, hydro and nuclear systems have been modeled and these areas are simulated in Simulink environment. All these aforesaid systems are controlled with conventional PI controller [18,19]. The performance of PI controller has been compared frequency deviation of three different power plants. From table. I it is found that PI controller show the best performance of settling time less frequency deviation and minimum oscillations. [6] P. Kundur, Power System Stability & Control, Tata McGraw Hill, New Delhi, Fifth reprint 2008, pp. 581-626. [7] C.E. Fosha and O.I. Elgerd, The megawatt frequency control problem: a new approach via optimal control theory, IEEE Trans. Power Appl. System, 89 (4) (1970), pp. 563 577. [8] Anand B., Ebenezer A. Jeyakumar. 2009. Load frequency control with fuzzy logic controller considering non-linearities and boiler dynamics, ICGST-ACSE Journal, ISSN 1687-4811, Volume 8, issue 111, pp 15-20. [9] Demiroren A., Zeynelgil H.L., Sengor N. S. 2001.The Application of ANN Technique to Load-frequency Control for Three- area Power System, IEEE Porto Power Tech Conference, PPT001, 10 th -13 th September2001, Porto, Portugal. [10] George-Gross, Lee J.W. 2001. Analysis of Load Frequency Control Performance Assessment Criteria, IEEEtransaction on Power System, Vol. 16, No. 16, pp. 520-525. [11] Ha Q. P. 1998. A Fuzzy sliding mode controller for Power System Load Frequency Control. Second International Conference ofknowledge based Intelligent Electronic System, 21-23 April, Vol. 1, pp. 149-154. [12] Hykin S. 1994. Neural Network, Mac Miller NY. [13] Ibrahim, Kumar P., Kothari D.P., 2005. Recent Philosophies of Automatic GenerationControl strategies in Power systems, IEEETransaction on Power System Vol.20, No.1, pp-346-357. [14] Kumar A., Malik O.P., Hope G. S.1985. Variable-structuresystem control applied to AGC of an interconnected power System, I.E.E.E. 1EE PROCEEDINGS, Vol. 132, Pt. C, No. 1,pp. 23-29. [15] Masiala M., Ghnbi M., Kaddouri A. 2004. An Adaptive Fuzzy Controller Gain Scheduling for Power System Load- Frequency Control, IEEE International Conference on Industrial Technology, (ICIT).pp.1515-1520. [16] Mines J. N. 1997. MATLAB Supplement to Fuzzy &Neural approach in Engineering, John Wiley NY. ACKNOWLEDGMENT This work is supported by Electrical Engineering Department, Indus University, Ahmedabad, Gujarat, India. REFERENCES [1] S. Sivanagaraju, G Sreenivasan, Power System Operation andcontrol, Pearson India. [2] Adman Kakilli, YukselOguz, HuseyinCalik, The Modeling Of Electric Power Systems on the State Space and Controlling Of Optimal LQR Load Frequency, Journal of Electrical and Electronics Engineering 2009, Vol. 9, Number 2. [3] K.P.SinghParmar, S.Majhi, D.P.Khothari, Optimal load frequency control of an interconnected power system, MIT International Journal of Electrical and Instrument Engg, Vol- 1, No.1, Jan-2011. [4] Mariano, S.J.P. Ferreira L.A.F.M., Optimal control Load frequency control of a large power system, Power Electronics and Motion control conference 2008. [5] M. Aldeen and H. Trinh, Load frequency control of interconnected power systems via constrained feedback control schemes, Int. Journal Computing Elect Eng Vol. 20 (1) (1994), pp. 71 88. ISSN: 2348 8379 www.internationaljournalssrg.org Page 14