PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

Similar documents
PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Compact dimming

LED Driver Compact fixed output

LED control gear Linear / area fixed output

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 150mA 400mA ECO lp ECO series

LED Driver Compact dimming

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO C ECO series

LED Driver Linear / area dimming

PHASED OUT. LED Driver Compact dimming. Driver LCAI 20W 350mA 900mA ECO SR ECO series

LED Driver Compact fixed output 4,5 83,5 93. Ordering data. Type

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 20W 350mA 550mA ECO lp ECO series

LED Driver Linear / area dimming. Udriver LCAI 20W 350mA 550mA ECO lp ECO series

LED Driver Linear / area fixed output

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series

LED Driver Constant voltage. Driver LC 60W 24V lp SNC ESSENCE series

LED Driver Compact fixed output

PHASED OUT. LED Driver Compact dimming. Driver LCAI 55W 900mA 1750mA ECO SR ECO series

LED Driver Compact fixed output. Udriver LC 25/30/35/40W 600/700/800/900mA fixc SC ADV ADVANCED series

LED Driver Compact fixed output

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

LED Driver Linear / area dimming

LED Driver Compact fixed output. Udriver LC 15/20/25W 350/500/700/600mA fixc C SNC ESSENCE series

LED Driver Constant voltage. Driver LC 100W 24V lp SNC ESSENCE series

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact fixed output

Emergency lighting units EM powerled

LED Driver Compact dimming

LED Driver Linear / area dimming

basicdim Wireless basicdim Wireless LED Drivers

LED control gear Compact fixed output. Uconverter LCI 20 W 350/500/700 ma TEC SR TEC series

LED Driver Constant voltage

LED Driver Constant voltage

Emergency lighting units EM powerled

LED Driver Linear / area dimming

LED Driver Constant voltage

LED Driver Constant voltage

LED Driver Constant voltage

LED Driver Compact fixed output

LED Driver Compact fixed output

PHASED OUT. LED Driver Compact fixed output. Driver LC 20W 500/700mA fixc SR SNC ESSENCE series

LED Driver Constant voltage

LED Driver Constant voltage. Driver LC 100W 24V SC SNC ESSENCE series

LED Driver Constant voltage. Udriver LCA 100W 24V one4all SC PRE PREMIUM series

LED Driver Compact dimming

LED Driver Constant voltage

LED control gear Compact dimming. Uconverter LCBI 10 W 180/350/500 ma phase-cut/1 10 V lp BASIC series

LED Driver Constant voltage

LED Driver Constant voltage

LED Driver Constant voltage. Udriver LCU 60W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED Driver Compact dimming outdoor

LED Driver Compact dimming outdoor

LED Driver Compact dimming outdoor

LED Driver Constant voltage

LED Driver Compact dimming outdoor

LED converter Linear / area dimming. Uconverter LCAI 80 W 350 ma one4all V ECO

FL ballasts Electronic dimming. PCA T8 EXCEL one4all lp Y II, W EXCEL T8

FL ballasts Electronic dimming. PCA T8 ECO lp Y II, W ECO T8

TD - Power Supply LP DALI&Switch Dim Mono PRE (CV) MM-IP20 User Manual

FL ballasts Electronic dimming. PCA T8 ECO lp Y, 3x18 W and 4x18 W ECO T8

FL ballasts Electronic dimming. PCA T5 EXCITE lp Y, 3 and 4x14/24 W EXCITE T5

LED converter Compact dimming. Uconverter LCAI 55 W 1400 ma O010 DALI ECO series Ø4,4. Ordering data

FL ballasts Electronic dimming. PCA T5 ECO lp Y, 3x14/24 W and 4x14/24 W ECO T5

PCA ECO lp Y, W T8 fluorescent lamps

LED control gear Compact fixed output. Uconverter LCI 50 W 1050 ma N020 TOP series Ø4,5. Ordering data

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

AC modules LED compact

ZITARES CCD 2 nd Generation SELV constant current control gear, 1-channel, dimm- and adjustable

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

ZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable

Tunable White LED linear / area

OT FIT 15/ /500 LT2 LP

ZITARES NCD 2 nd Generation Non-SELV, constant current control gear, 1-channel, dimmable

basicdim Wireless Casambi Ready

LC35/2-DA-iC. 35 W Dimmable two channel intelligent Colour LED driver. 35 W V 0 / Hz. Functional Description. Mains Characteristics

PCA T8 EXCEL one4all lp Y, W T8 fluorescent lamps

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

ZITARES CC Constant current control gear, 2-channel, dimmable

LED catalogue Issue October 2013

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL series. PCA TCL EXCEL one4all lp Y, 55 W Compact and T5c fluorescent lamps

ZITARES CC Constant current control gear, 1-channel, dimmable

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

ZITARES NCS 2 nd Generation Non-SELV, Constant current control gear, 1-channel, non-dimmable

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

ZITARES LCS Non-SELV, Constant current control gear, 1-channel, non-dimmable

U LED modules, converters and systems CONVERTER. Uconverter LCAI 50 W 1050 ma N020 DALI uconverter REMOTE LCI

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ADV Modules SLE ADVANCED

OTi DALI 80/ / CH OTi DALI 50/ / CH

Lighting Controls and Connectivity basicdim. basicdim Wireless PWM CV 4CH Wireless module for basicdim

PHASED OUT. LED light engine / OLED LED linear / area. Umodule STARK INDI CLASSIC STARK INDI

OPTOTRONIC Intelligent

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Transcription:

EL Product description Fixed output built-in LED Driver Constant current LED Driver Output current settable 30 900 ma Max. output power 20 W Nominal life-time up to 100,000 h For luminaires of protection class I and protection class II -year guarantee Properties Casing: polycarbonate, white Type of protection IP20 Functions Intelligent Temperature Guard (overtemperature protection) Short-circuit proof Overload protection Suitable for emergency escapge lighting systems acc. to EN 0172 È Standards, page 4 Driver LCI 20W 30mA 900mA TOP C TOP series 47.4 tc 9 10 4.2 10 28.3 60 70 Ordering data Type Article number Packaging Packaging carton pallet Weight per pc. LCI 20W 30mA-900mA TOP C 28000191 10 pc(s). 960 pc(s). 0.120 kg www.tridonic.com 1

Technical data Rated supply voltage 220 240 V AC voltage range 198 264 V DC voltage range 176 280 V (start 198 V DC) Mains frequency Overvoltage protection Leakage current (PE) Max. input power 0 / 0 / 60 Hz 320 V AC, 48 h < 0. ma 24.7 W Efficiency (at 230 V, 0 Hz, full load) 81 8. % THD (at 230 V, 0 Hz, full load) 10 % Output current tolerance ± % Output LF current ripple (< 120 Hz) < 2 % Max. peak output current Output current + 20 % Max. output voltage Time to light (at 230 V, 0 Hz, full load) Hold on time at power failure or switch-off Switchover time (AC/DC) Burst / surge peaks output side against PE Dimensions L x W x H Specific technical data Type LCI 20W 30mA-900mA TOP C Output current 60 V < 0. s 1 s < 0. s 2 kv 10 x 70 x 28.3 mm Min. forward Max. forward Max. output Input power Input current λ tc point voltage voltage power (at 230 V, 0 Hz, (at 230 V, 0 Hz, (at 230 V, 0 Hz, full load) full load) full load) Ambient temperature ta tc/ta for 0.000 h I sel resistor value 30 ma 22 V 48.0 V 16.8 W 19.6 W 93 ma 0.92 80 C -2... +6 C 76 / 60 C open circuit 400 ma 22 V 48.0 V 19.2 W 23.3 W 108 ma 0.94 80 C -2... +6 C 76 / 60 C 66.0 kω 40 ma 20 V 44.4 V 20.0 W 23.4 W 108 ma 0.94 80 C -2... +6 C 76 / 60 C 7.60 kω 00 ma 18 V 40.0 V 20.0 W 23. W 109 ma 0.94 80 C -2... +6 C 76 / 60 C 49.90 kω 0 ma 16 V 36.4 V 20.0 W 23.7 W 110 ma 0.94 80 C -2... +6 C 76 / 60 C 42.20 kω 600 ma 1 V 33.3 V 20.0 W 23.8 W 110 ma 0.94 80 C -2... +6 C 76 / 60 C 3.70 kω 60 ma 14 V 30.8 V 20.0 W 23.9 W 111 ma 0.94 80 C -2... +60 C 74 / C 28.70 kω 700 ma 13 V 28.6 V 20.0 W 24.0 W 111 ma 0.94 80 C -2... +60 C 74 / C 22.00 kω 70 ma 12 V 26.7 V 20.0 W 24.1 W 111 ma 0.94 80 C -2... +60 C 74 / C 1.00 kω 800 ma 11 V 2.0 V 20.0 W 24.3 W 112 ma 0.94 80 C -2... +60 C 74 / C 10.00 kω 80 ma 11 V 23. V 20.0 W 24.4 W 112 ma 0.9 80 C -2... +60 C 74 / C.36 kω 900 ma 10 V 22.2 V 20.0 W 24. W 112 ma 0.9 80 C -2... +60 C 74 / C short circuit www.tridonic.com 2

Product description Ready-for-use resistor to set output current value Compatible with LED Driver series TOP and ECO Resistor is base isolated Resistor power 0.2 W Resistor value tolerance ± 1 % ACCES- SORIES I-SELECT PLUG TOP / ECO Ordering data 9, 3, Type Article number Colour Marking Resistor value Packaging bag Weight per pc. I-SELECT PLUG 400mA GN 2800041 Green 0400 66.0 kω 10 pc(s). 0.001 kg I-SELECT PLUG 40mA GN 2800042 Green 040 7.60 kω 10 pc(s). 0.001 kg I-SELECT PLUG 00mA GN 28000277 Green 000 49.90 kω 10 pc(s). 0.001 kg I-SELECT PLUG 0mA GN 2800043 Green 00 42.20 kω 10 pc(s). 0.001 kg I-SELECT PLUG 600mA GN 2800044 Green 0600 3.70 kω 10 pc(s). 0.001 kg I-SELECT PLUG 60mA GN 280004 Green 060 28.70 kω 10 pc(s). 0.001 kg I-SELECT PLUG 700mA GN 28000278 Green 0700 22.00 kω 10 pc(s). 0.001 kg I-SELECT PLUG 70mA GN 2800046 Green 070 1.00 kω 10 pc(s). 0.001 kg I-SELECT PLUG 800mA GN 2800047 Green 0800 10.00 kω 10 pc(s). 0.001 kg I-SELECT PLUG 80mA GN 2800048 Green 080.36 kω 10 pc(s). 0.001 kg I-SELECT PLUG MAX GR 28000274 Grey MAX 0 Ω 10 pc(s). 0.001 kg xxxx 3, 6 13, www.tridonic.com 3

Standards EN 01 EN 61000-3-2 EN 61000-3-3 EN 61347-2-13 EN 62384 EN 6147 According to EN 0172 for use in central battery systems According to EN 6098-2-22 suitable for emergency lighting installations Output current setting Output current can be set by connecting a resistor between the 2 I sel terminals. Relationship between output current and resistor value can be found at the table Specific technical data. Resistor values specified from standardised resistor value ranges. Resistor value tolerance has to be 1 %. Resistor power has to be 0.1 W. If the resistor is connected with wires a max. wire length of 2 m may not be exceeded and possible interferences have to be avoided. Resistor detection at each start. Change of the resistor value during the operation will be not considered. Resistors for the main output current values can be ordered from Tridonic (see accessories). DC emergency operation The LED Driver is designed for operation on DC voltage and pulsed DC voltage. Light output level in DC operation (EOFx): 100 % (cannot be adjusted) The voltage-dependent input current of Driver incl. LED module is depending on the used load. The voltage-dependent no-load current of Driver (without or defect LED module) is for: AC: < 23 ma DC: < 8 ma Overload protection LED Driver will switch off at overload operation. Mains reset is required to restart the LED Driver. Underload operation LED Driver will switch off at underload operation. Mains reset is required to restart the LED Driver. Overtemperature protection The LED Driver will reduce output current at temporary thermal over-heating (exceeding max. tc point). On DC operation this function is deactivated to fulfill emergency requirements. Conditions of use and storage Humidity: % up to max. 8 %, not condensed (max. 6 days/year at 8 %) Storage temperature: -40 C up to max. +80 C Expected life-time Type Output current ta 40 C 0 C C 60 C 6 C tc 6 C 66 C 71 C 76 C 80 C 30 600 ma LCI 20W 30mA-900mA Life-time > 100,000 h 100,000 h 7,000 h 0,000 h 30,000 h TOP C tc 9 C 69 C 74 C 80 C x 60 900 ma Life-time > 100,000 h 7,000 h 0,000 h 30,000 h x x = not permitted Short-circuit behaviour LED Driver will switch off in case of short-circuit of LED output. Mains reset is required to restart the LED Driver. No-load operation or load loss during operation LED Driver will detect a load loss during operation. In this case and no-load operation the max. output voltage can apply at the LED output for max. s before LED Driver shuts down. Mains reset is required to restart the LED Driver. Hot plug-in Hot plug-in is not recommend within s after shutdown due to output voltage of > 0 V. Mains reset is required to restart the LED Driver if LED module is connected to the LED Driver after these s. The devices have to be within the specified temperature range (ta) before they can be operated. Glow-wire test according to EN 61347-1 with increased temperature of 960 C passed. Temperature range The LED Driver life duration is related to the ambient temperature ta. The relation of tc to ta temperature depends also on the luminaire design. If the measured tc temperature is approx. K below tc max. or higher, ta temperature should be checked and eventually critical components (e.g. ELCAP) measured. Detailed information on request. The LED Driver is designed for a life-time stated above under reference conditions and with a failure probability of less than 10 %. Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C20 B10 B13 B16 B20 Inrush current Installation Ø 1, mm 2 1, mm 2 2, mm 2 2, mm 2 1, mm 2 1, mm 2 2, mm 2 2, mm 2 I max time LCI 20W 30mA-900mA TOP C 6 8 11 130 6 8 11 130 4 A 40 μs Harmonic distortion in the mains supply (at 230 V / 0 Hz and full load) in % THD 3.. 7. 9. 11. LCI 20W 30mA-900mA TOP C 10 8 3 2 2 2 www.tridonic.com 4

Installation instructions Circuit diagram Wiring type and cross section The wiring can be in stranded wires with ferrules or solid with a cross section of 0. 1. mm² for mains wires and 0.2 1. mm² for secondary wires. Strip 9. mm of insulation from the cables to ensure perfect operation of the push-wire terminals. Use one wire for each terminal connector only. wire preparation: 0.2 1. mm² 8. 9. mm Release of the wiring Press down the push button and remove the cable from front. Mounting of device Max. torque for fixing: 0. Nm/M4 Wiring guidelines All connections must be kept as short as possible to ensure good EMI behaviour. Earthing is not required for the device to operate but will improve the EMI behaviour. If LCI TOP C will be earthed protection earth (PE) has to be used. Mains leads should be kept apart from LED Driver and other leads (ideally 10 cm distance) Max. length of output and I sel wires is 2 m. Secondary switching is not permitted. Incorrect wiring can demage LED modules. The wiring must be protected against short circuits to earth (sharp edged metal parts, metal cable clips, louver, etc.). Earth connection The earth connection is conducted as protection earth (PE). If the LED driver will be earthed, protection earth (PE) has to be used. There is no earth connection required for the functionality of the LED Driver. Earth connection is recommended to improve following behaviour. 220 240 V 0/0/60 Hz L N PRI SEC + LED LED I sel 1 I sel 2 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 6098-1 Annex Q (informative only!) or ENEC 303-Annex A, each luminaire should be submitted to an isolation test with 00 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 6098-1 Annex Q describes a test of the electrical strength with 100 V AC (or 1.414 x 100 V DC). To avoid damage to the electronic devices this test must not be conducted. Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Electromagnetic interferences (EMI) Transmission of mains transients to the LED output In general it is recommended to earth the LED Driver if the LED module is mounted on earthed luminaire parts respectively heat sinks and thereby representing a high capacity against earth. Life-time declarations are informative and represent no warranty claim. No warranty if device was opened. R www.tridonic.com

Diagrams LCI 20W 30mA-900mA TOP C Efficiency vs load Power factor vs load Efficiency [%] Input power [W] THD 8 80 7 70 30 2 20 1 10 30 2 20 1 10 Input power vs load 0 THD vs load 0 Power factor Input current [ma] 1,00 0,98 0,96 0,94 0,92 0,90 0,88 0,86 0,84 0,82 0,80 120 100 80 60 40 20 30 ma 00 ma 700 ma 900 ma Input current vs load 0 www.tridonic.com 6