Safety Monitoring Relays

Similar documents
Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

CSM_G7S-_-E_DS_E_7_1

SPST-NO SPDT DPST-NO DPDT

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Relays with Forcibly Guided Contacts G7SA

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Classification Enclosure rating Contact form Contact material

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

SPST-NO SPDT DPST-NO DPDT

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

3. Contact Form A: SPST-NO

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

MY-GS CSM_MY-GS_DS_E_2_1

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

OMRON MK-I / -S RELAY

Model Number Structure

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

Safety Relay Unit. OFF-delay time

Surface-mounting Relay

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

General-purpose Relay

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

Slim compact safety relay

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Model Number Structure

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

G2RV-SL Slim I/O Relay will be discontinued February 2019

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

SLIM COMPACT SAFETY RELAY

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

General-purpose Relay

Details on the New G2RS

Technical Information General Purpose Relays. Glossary. Maximum switching power [W(VA)] Switching current (A) Switching voltage (V) Contact Symbols

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

General-purpose Relay

Ordering Information. Ratchet Relay G4Q. Model Number Legend

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Compact Relay Family with Forcibly Guided Contacts

Ratings Ratings SPST-NO SPDT DPST-NO DPDT

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

RU Series Universal Relays

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

1a/1c/2a/2c/5A/10A power relays for power supply

PCB relay for DC voltage, polarized, monostable or bistable

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

1a 8A, 1a1b/2a 5A small polarized power relays

Features. Insulation system F 835-1A-F-C 835-1A-F-S L-1A-C 835L-1A-S F 835L-1A-F-C 835L-1A-F-S NL-1A-C 835NL-1A-S

Compliant with European standards 1a/1c 6A Slim power relays

1a 8A, 1a1b/2a 5A small polarized power relays

Relays & Sockets. General-purpose electromechanical relays and sockets

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

Transistor drive 2c/4c 5A slim power relays

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

1a/1c/2a/2c/5A/10A power relays for power supply

Tactile Switch. Ordering Information. A Wide Range of Models: 6 6 mm, mm, Side-operated, High-force, and Gold-plated.

RJ Series Slim Power Relays

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Technical Information General Purpose Relays

1a/1c 5A/10A small power relays

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

Class Sealing Fully sealed Contact configuration Rated coil voltage Model Basic Type SPDT 4.5 VDC G6Y-1 5 VDC 9 VDC 12 VDC 24 VDC

UNIQUELY DESIGNED RELAY FEATURES

Transcription:

Safety Monitoring Relays Contents Selection Guide I-2 Safety Monitoring Relays G9SA I-6 SR0A I-2 SR03AM I-3 SR04P I-7 SR05E I-7 SR06ED I-2 SR08AD & SR09AD I-8 SR20MP I-2 SR25SMS45 I-22 SR3A I-25 SR20A I-25 SR203M & SR203AM I-26 SR208AD & SR209AD I-26 SR223SMT I-27 SR23A I-27 Flexible Safety Units/Dedicated Function G9SX I-28 G9SX-GS I-38 G9SX-SM I-48 Force-guided Relays G7SA I-49 G7S- -E I-55 Power Contactor with Mirror Contacts J7KNA-AR I-58 G7Z I-62 I-

Safety Monitoring Relays/Force-guided Relays G7SA S353 Compact, Slim Relays Conforming to EN Standards Relays with forcibly guided contacts (EN50205 Class A, certified by VDE) Supports the CE marking of machinery (Machinery Directive) Helps avoid hazardous machine status when used as part of an interlocking circuit Four-pole and six-pole Relays are available The relay s terminal arrangement simplifies PWB pattern design Reinforced insulation between inputs and outputs. Reinforced insulation between some poles of different polarity. I C US Specifications Ratings Coil Rated Voltage Rated Current (ma) Coil Resistance (Ω) Must Operate Must Release Max. Power Consumption (mw) 4 poles: 5 6 poles: 20.8 4 poles:,600 6 poles:,52 75% max. 0% min. 0% 4 poles: Approx. 360 6 poles: Approx. 500. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of ±5%. 2. Performance characteristics are based on a coil temperature of 23 C. 3. The maximum voltage is based on an ambient operating temperature of 23 C maximum. Contacts Resistive Load Rated load 6 A at 250 VAC, 6 A at 30 VDC Rated carry current 6 A Max. switching voltage 250 VAC, 25 VDC Max. switching current 6 A Max. drop-out time* 0 ms *The drop-out time is the time it takes for the N/O contacts to open after the coil voltage is turned OFF. Certified Standards EN Standards, VDE Certified EN680- (Electromechanical non-specified time all-or-nothing relays) EN50205 (Relays with forcibly guided (linked) contacts) UL standard UL508 Industrial Control Devices CSA standard CSA C22.2 No. 4 Industrial Control Devices Forcibly-Guided Contacts (from EN50205) If an NO contact becomes welded, all NC contacts will maintain a minimum distance of mm when the coil is not energized. Likewise if an NC contact becomes welded, all NO contacts will maintain a minimum distance of mm when the coil is energized. Characteristics of Sockets Model Continuous Current Dielectric Strength Insulation Resistance P7SA- 6 A * 2,500 VAC for min. between poles,000 MΩ min. *2 Use the P7SA- F-ND in the ambient temperature range of -20 to 70 C. Use the P7SA- F and P7SA- F-ND in the ambient humidity range of 45 to 85%. *. When operating the P7SA- F at a temperature between 55 and 85 C, reduce the continuous current (6 A at 55 C or less) by 0. A for each degree above 55 C. When operating the P7SA- F-ND at a temperature between 50 and 70 C, reduce the continuous current (6 A at 50 C or less) by 0.3 A for each degree above 50 C. *2. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. I-49

G7SA Safety Monitoring Relays/Force-guided Relays Specifications (continued) Contact resistance * Operating time *2 Response time *3 Release time *2 Must operate voltage 00 mω max. 20 ms max. 0 ms max. 20 ms max. 75% max. Must release voltage 0% min. Maximum operating Mechanical 36,000 operation/h frequency Rated load,800 operation/h Insulation resistance *4,000 MΩ min. Dielectric strength *5 *6 Between coil contacts/different poles (except for poles 3-4 in 4-pole relays and poles 3-5, 4-6, and 5-6 in 6-pole relays): 4,000 VAC, 50/60 Hz for min. Between different poles (poles 3-4 in 4-pole relays and poles 3-5, 4-6, and 5-6 in 6-pole relays): 2,500 VAC, 50/60 Hz for min. Between contacts of same polarity:,500 VAC, 50/60 Hz for min. Vibration resistance 0 to 55 to 0 Hz, 0.75 mm single amplitude (.5 mm double amplitude) Shock resistance Destruction,000 m/s 2 Malfunction 00 m/s 2 Durability *7 Mechanical 0,000,000 operations min. (at approx. 36,000 operations/h) Electrical 00,000 operations min. (at the rated load and approx.,800 operations/h) Inductive load switching capability *8 (IEC60947-5-) Failure rate (P level) (reference value *9) Ambient operating temperature *0 AC5 AC250V 2A DC3 DC24V A 5 VDC, ma 2 to 48 VDC: -40 to 85 C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight 4 poles: Approx. 22 g 6 poles: Approx. 25 g Specifications are subject to change without notice.. The above values are initial values. 2. Performance characteristics are based on coil temperature of 23 C. *. The contact resistance was measured with A at 5 VDC using the voltage-drop method. *2. These times were measured at the rated voltage and an ambient temperature of 23 C. Contact bounce time is not included. *3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF. Contact bounce time is included. Measurement conditions: Rated voltage operation, Ambient temperature: 23 C. *4. The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *5. Pole 3 refers to terminals 3-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64. *6. When using a P7SA Socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for min. *7 The durability is for an ambient temperature of 5 to 35 C and an ambient humidity of 25% to 75%. For the durability performance to the load refer to the Durability Curve. *8. AC5: cosø = 0.3, DC4: L/R = 48 ms. *9. The failure rate is based on an operating frequency of 300 operations/min. *0. 2 to 48 VDC: When operating between 70 to 85 C, reduce the rated current of 6 A by 0. A for each degree above 70 C. I-50

G7SA Safety Monitoring Relays/Force-guided Relays Engineering Data Durability Curve No. of operations ( 0 4 operations),000 700 500 300 00 70 50 30 0 7 5 DC3, AC5, 240 VAC DC, AC, 240 VAC I 3 0. 0.3 0.7 3 5 7 0 Contact current (A) Dimensions (mm) G7SA-3AB G7SA-2A2B 40 max. 3 max. Terminal Arrangement/ Internal Connection Diagram G7SA-3AB Printed Circuit Board Design Diagram (±0. tolerance) Ten,.4 dia. 24 max. 3.5 G7SA-2A2B. Terminals 23-24, 33-34, and 43-44 are normally open. Terminals -2 and 2-22 are normally closed. 2. The colors of the cards inside the Relays are as follows: G7SA- 3AB: Blue and G7SA-2A2B: White. G7SA-5AB G7SA-4A2B G7SA-3A3B Terminal Arrangement/ Internal Connection Diagram G7SA-5AB Printed Circuit Board Design Diagram (±0. tolerance) Fourteen,.4 dia. 50 max. 3 max. 24 max. 3.5 G7SA-4A2B G7SA-3A3B. Terminals 23-24, 33-34, 43-44, 53-54, and 63-64 are normally open. Terminals -2, 2-22, and 3-32 are normally closed. 2. The colors of the cards inside the Relays are as follows: G7SA- 5AB: Blue, G7SA-4A2B: White, and G7SA-3A3B: Yellow. I-5

G7SA Safety Monitoring Relays/Force-guided Relays Dimensions (continued) (mm) Track-mounting Socket P7SA-0F, P7SA-0F-ND Terminal Arrangement/Internal Connection Diagram (Top View) G7SA-3AB Mounted G7SA-2A2B Mounted 44 33 34 43 24 44 33 34 43 22 23 * * 2 2 2 9 max. 5 2R 22.5 max. Ten, M3 8 6 max. 0 0 Mounting Hole Placement Diagram (Top View) Two, 4 dia. or M3.5 * This display circuit is available only for "-ND" models. Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals -2 and 2-22 are normally closed. 72 max. LED indicator 9 max. 4 dia. Note : The socket is shown with the finger cover removed. 2: Only the -ND Sockets have LED indicators (orange) Track-mounting Socket P7SA-4F, P7SA-4F-ND Terminal Arrangement/Internal Connection Diagram (Top View) G7SA-5AB Mounted G7SA-4A2B Mounted G7SA-3A3B Mounted 64 54 64 54 64 54 63 53 63 53 63 53 44 34 44 34 44 32 43 * * * 33 43 33 43 3 24 2 22 2 22 2 9 max. 5 2R 30 max. Fourteen, M3 8 6 max. 23 0 2 0 2 0 72 max. LED indicator Mounting Hole Placement Diagram (Top View) Two, 4 dia. or M3.5 * This display circuit is available only for "-ND" models. Note: Terminals 23-24, 33-34, 43-44, 53-54, and 63-64 are normally open. Terminals -2, 2-22, and 3-32 are normally closed. 9 max. 4 dia. Note : The socket is shown with the finger cover removed. 2: Only the -ND Sockets have LED indicators (orange). I-52

G7SA Safety Monitoring Relays/Force-guided Relays Dimensions (continued) (mm) Back-mounting Socket (for PCB) P7SA-0P 50 max. 5 max. Terminal Arrangement/Internal Connection Diagram Mounting Hole Placement (±0. tolerance) I G7SA-3AB Mounted 0 2 33 34 4.5 max. 23 24 43 44 Three, 3.2 dia. (for M3 tapping screws) G7SA-2A2B Mounted 0 2 33 34 (.) 0.4 (.) 3.5 Ten,. dia. Three, 2.6 dia. (for M3 tapping screws) 2 22 43 44 4. 24.8 39.9 Note: Terminals 23-24, 33-34, and 43-44 are normally open. Terminals -2 and 2-22 are normally closed. Back-mounting Socket (for PCB) P7SA-4P 60 max. Terminal Arrangement/Internal Connection Diagram Mounting Hole Placement (±0. tolerance) 5 max. 4.5 max. G7SA-5AB Mounted 0 2 33 34 53 54 23 24 43 44 63 64 Fourteen,. dia. Three, 3.2 dia. (for M3 tapping screws) G7SA-4A2B Mounted 0 2 33 34 53 54 (.) 0.4 (.) 3.5 2 22 43 44 63 64 4. 24.8 49.9 Three, 2.6 dia. (for M3 tapping screws) G7SA-3A3B Mounted 0 2 3 32 53 54 2 22 43 44 63 64 Note: Terminals 23-24, 33-34, 43-44, 53-54, and 63-64 are normally open. Terminals -2, 2-22, and 3-32 are normally closed. I-53

G7SA Safety Monitoring Relays/Force-guided Relays Ordering Model Number Legend G7SA A B 2 NO Contact Poles 2: DPST-NO 3: 3PST-NO 4: 4PST-NO 5: 5PST-NO 2 NC Contact Poles : SPST-NC 2: DPST-NC 3: 3PST-NC Relays with Forcibly Guided Contacts Type Sealing Poles Contact Configuration Rated Voltage* Model 4 poles 3PST-NO, SPST-NC G7SA-3AB DC24 DPST-NO, DPST-NC G7SA-2A2B DC24 Standard Flux-tight 5PST-NO, SPST-NC G7SA-5AB DC24 6 poles 4PST-NO, DPST-NC G7SA-4A2B DC24 3PST-NO, 3PST-NC G7SA-3A3B DC24 *Consult your Omron representative for details on rated voltages of 2 VDC, 8 VDC, 2 VDC and 48 VDC. Sockets Type LED Indicator Poles Rated Voltage Model Track-mounting Track mounting and screw mounting possible No 4 poles P7SA-0F --- 6 poles P7SA-4F Yes 4 poles P7SA-0F-ND DC24 6 poles P7SA-4F-ND DC24 Back-mounting PCB terminals No 4 poles P7SA-0P --- 6 poles P7SA-4P Relays with Forcibly Guided Contacts and Track Mounting Sockets (assemblies) Poles Relay Specifications Contact Configuration Rated Coil Voltage Type Socket Specifications LED Indicator LED Rated Voltage Assembly Model 4 poles DPST-NO, DPST-NC Track Mounting and screw mounting possible No FGRMS22-24 4 poles 3PST-NO, SPST-NC Track Mounting and screw mounting possible No FGRMS3-24 6 poles 3PST-NO, 3PST-NC Track Mounting and screw mounting possible No FGRMS33-24 6 poles 4PST-NO, 2PST-NC Track Mounting and screw mounting possible No FGRMS42-24 6 poles 5PST-NO, SPST-NC Track Mounting and screw mounting possible No FGRMS5-24 4 poles DPST-NO, DPST-NC Track Mounting and screw mounting possible Yes FGRMS22-24-LED 4 poles 3PST-NO, SPST-NC Track Mounting and screw mounting possible Yes FGRMS3-24-LED 6 poles 3PST-NO, 3PST-NC Track Mounting and screw mounting possible Yes FGRMS33-24-LED 6 poles 4PST-NO, 2PST-NC Track Mounting and screw mounting possible Yes FGRMS42-24-LED 6 poles 5PST-NO, SPST-NC Track Mounting and screw mounting possible Yes FGRMS5-24-LED I-54

Safety Monitoring Relays/Force-guided Relays G7S- -E S352 Lineup Now Includes 0 A Models Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery (Machinery Directive). Helps avoid hazardous machine status when used as part of an interlocking circuit. Track-mounting and Back-mounting Sockets are available. I Specifications Ratings Coil Rated Voltage Rated Current (ma) Coil Resistance (Ω) Must Operate Must Release Max. Power Consumption (W) 30 800 80% max. 0% min. 0% Approx. 0.8. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of ±5%. 2. Performance characteristics are based on a coil temperature of 23 C. 3. The maximum voltage is based on an ambient operating temperature of 23 C maximum. Contacts Rated load NO contact NC contact NO contact Rated carry current NC contact Maximum switching voltage Maximum switching NO contact current NC contact Resistive load Inductive load * 0 A at 250 VAC 0 A at 30 VDC 6 A at 250 VAC 6 A at 30 VDC 0 A 6 A 250 VAC, 30 VDC 0 A 6 A AC-5: 5 A at 240 VAC DC-3: 2 A at AC-5: 3 A at 240 VAC DC-3: 2 A at *In the above table, cosø = 0.3 for AC-5 inductive loads and L/R = 96 ms for DC-3 inductive loads. Certified Standards EN Standards, VDE Certified EN680- (Electromechanical non-specified time all-ornothing relays) EN60255-23 (Contact performance) EN50205 (Relays with forcibly guided (linked) contacts) UL standard UL508 Industrial Control Devices CSA standard CSA C22.2 No. 4 (Industrial Control Equipment) Forcibly-Guided Contacts (from EN50205) If an NO contact becomes welded, all NC contacts will maintain a minimum distance of mm when the coil is not energized. Likewise if an NC contact becomes welded, all NO contacts will maintain a minimum distance of mm when the coil is energized. Characteristics of Sockets Model Continuous Current Dielectric Strength Insulation Resistance P7S-4 0 A 2,000 VAC for min. between poles,000 MΩ min. * Use the P7SA-4F-END in the ambient temperature range of 35 to 85% *Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC. I-55

G7S- -E Safety Monitoring Relays/Force-guided Relays Dimensions (mm) G7S-4A2B-E G7S-3A3B-E 62 max. 58 22.5 max. Terminal Arrangement/Internal Connection Diagram G7S-4A2B-E 0.8 6 37 max. + 0 3 4 33 34 5 52 23 24 43 44 6 62 Mounting Hole Dimensions 6 7 0.6.5 8 5 min. G7S-3A3B-E 8±0. 4.5±0. 4.5 + 0 3 4 33 34 5 52 23 24 4 42 6 62 Fourteen,.8 dia. 7 6 2±0. 35±0. 7±0. 3 Track-mounting Socket P7S-4F-END Indicator Fourteen, M3.0 8 Terminal Arrangement/Internal Connection Diagram (Top View) 40 max. 33±0. 4 7.5 24 23 4 3 0 4 42 43 44 Mounting Hole Dimensions 52 33 34 62 6 5 37 80 max. 7 33±0. Two, M3.5- or 4.0-dia. holes 5 (5) 9 max. 3. 5.9 Back-mounting Socket (PCB Terminals) P7S-4P-E 23.5 max. 7 max. 28±0.2 Two, 6.5 dia. 8 depth Terminal Arrangement/Internal Connection Diagram With G7S-4A2B-E mounted Mounting Hole Dimensions 2.8 28±0.2 4.2 (2) (6.9) With G7S-3A3B-E mounted 4.5 8 57 max. Fourteen, 2.5 dia. 6 5 7=35 7 Two, 3.6 dia. 3.2 6 5 7=35 7 (5) 6.9 8 4.5 23.5 max. 4. I-56

G7S- -E Force-Guided Relay Ordering Model Number Legend G7S A B E 2 NO Contact Poles 3: 3PST-NO 4: 4PST-NO 2 NC Contact Poles 2: DPST-NC 3: 3PST-NC I Relays with Forcibly Guided Contacts Type Poles Contact Configuration Rated Voltage* Model Standard 6 poles 4PST-NO, DPST-NC 3PST-NO, 3PST-NC G7S-4A2B-E G7S-3A3B-E Sockets Type Rated Voltage Model Track-mounting Common for track mounting and screw mounting P7S-4F-END Back-mounting PCB terminals --- P7S-4P-E I-57