Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Bulletin 800H mm Mounting Hole Type 4/4X/13 Corrosion-Resistant/ Watertight/Oiltight Heavy Industrial Stations and Operators TABLE OF CONTENTS

1.3. Pushbuttons and Indicating Lights.

Bulletin 800MR/800MB Push Buttons

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

TWTD Series: Heavy duty switches built to last

Bulletin 800MR/800MB Push Buttons

Round Indicator Lights Mounting Hole Page

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

A W - A 2A R - 24D - 1

Accessories. Accessories

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

Pendant control stations 6

Local control stations for Zone 1 and Zone 21. Features. Description

STOP. V00029AC Rev. 04 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID TOOL LIST. NET-ACCESS S-Type Network Cabinets

OPERATING USER MANUAL for PRESSURE RECORDERS

SB 50 Connectors - up to 120 amps

Control Stations ø 22

Actuators Series 8602/3

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes

5570M Series Intercom Installation and Operation Guide

**MOUNTING YOUR MONITOR

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

MODEL: 47LV. Digital Panel Meters 47 Series

Complete units: Selector switches ø 22mm

model tsa-sa48 Sliding Crosscut Table installation guide

INSTRUCTION BOOK EASILY REMOVEABLE DIES FOR YOUR BINDING NEEDS OD 4012 SHOWN WITH THE OPTIONAL PALM SWITCH FOR THE OD 4012

Complete units: Push-buttons ø 22mm

Precision made in Germany. As per DIN The heart of a system, versatile and expandable.

Complete units: Mushroom heads ø 22mm

Sorenson Lighted Controls

Elderfield & Hall, Inc., Kama Bandsaw AD 105S. Instruction Manual: Introduction to the Manual. General Precautions. Equipment. Machine.

MINIATURE RELAY FOR WIDER APPLICATIONS

Detecting Devices. 8/2 Introduction

Installation Instructions

General Specifications

Model Number Structure

LAN Locker Adjustable Shelves

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

J-BOX. 3-O or 4-0 MUD RING J-BOX BRACKET BAR CABLE GRIPPER/ CANOPY MOUNTING STUD 8-32 BRACKET BAR SCREWS CANOPY STRAIN RELIEF POWER CORD CANOPY

SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES

SEALED, ILLUMINATED ROCKER SWITCHES

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

Switches & Pilot Devices

Assembly Instructions

Operator Heads: ø 22mm

19-in. Mini-Rack Cabinet, Type 1

Explosion-roof ilot Devices Nema Type 4, 4, 7 9 ilot ights igtail Saddle Clamp Transformer Illuminated.. ush-to-test ini ush uttons Flush Extended Dua

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

NCR-80. BinMaster Price Book binmaster.com Subject to change without notice 1

Preference Collection and Treatment Console INSTALLATION GUIDE

CM340B STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINET FROM SKID

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

4 BAY Low Profile WALL MOUNT CABINET

Position switches FM series

SBS Connectors - up to 110 amps

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Solenoid Data Book 1425 Lake Avenue Woodstock, IL Phone: (815) Toll Free: Sales Fax: (815)

600G2 Internal Sliding Adapter Panel Shelf Instructions

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

SLIDING DOOR LOCKS MISCELLANEOUS

Pow-R-Feed Systems Service Manual

DEUTSCH Instructional Manual for HDP-400 Power Crimper (TE CONNECTIVITY PN )

FSK1VDRA 1G Al DPLX RCPT CVR

INSTALLATION INSTRUCTIONS

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

OMRON MK-I / -S RELAY

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

Specifications. Safety Ratings. Standards. Safety Classification

VERTICAL PLATFORM LIFT

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE

General Purpose Relays Types K, R, N, and C

LOGIC Component Technology VOLTAGE SENSOR SENSORS & DETECTORS Voltage Sensor Data Sheet: DS-VS-14

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

Series 80 In-Line Mounted Centrifugal Pumps

HANDHOLE SEAT GRINDER

1.8. Panic Exit Devices. ED22 Series, ED2227 Series, ED22M Series, Accessories and Parts. Mechanics

30AUTO Speed Lathe Manual

Senior Swing. Caution

INSTALLATION INSTRUCTIONS LARGE FLAT PANEL IN WALL ENCLOSURE Model: PAC-500

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series

Custom Wood Frame Overlay for Glass Doors Installation Instructions

XXXX e. X d.. X X X a

Transcription:

10 ulletin 800H Hazardous Locations Push uttons and Stations Classes I, II & III Divisions 1 & 2 3/4" - 14 NPSM arrel Type7&9 Explosion-Proof perators 0 TLE F CNTENTS Page Page Specifications...10-113 Complete ssembled Stations...10-114 Push uttons, Non-Illuminated MomentaryContact...10-116 Dual Units...10-116 Push uttons, Illuminated MomentaryContact...10-118 Potentiometer...10-118 Push-Pull, Non-Illuminated 2-Position...10-120 3-Position...10-120 Push-Pull, Illuminated 2-Position...10-122 3-Position...10-122 Selector Switches 2-Position...10-124 3-Position...10-126 4-Position...10-128 Pilot Lights Standard...10-130 Push-to-Test...10-130 Pigtail...10-130 Typical Pilot Light Wiring Diagrams...10-130 Enclosures...10-132 Stations rdering Information....10-133 Covers, Lever Type ctuator...10-134 Covers, Component Type utton....10-134 ssembled ases (Field ssembly or Custom Stations)..10-135 ases for Multi-Gang Stations...10-136 Modifications and ccessories Contactlocks...10-137 Caps,Knobsanduttons...10-138 ootsandootedknobs...10-139 Guards...10-139 ClosingPlugs,Coupler,ConduitEntryPlug...10-140 Padlockingttachments...10-140 FlangeSeals...10-141 Miscellaneous...10-141 Legend Plates...10-142 pproximate Dimensions...10-144 10-112 llen-radley Spares

Specifications ➊ ulletin 800H Electrical Ratings Contact Ratings Refer to the Contact Ratings tables below. Dielectric Strength 2200V for one minute, 1300V for one minute (Logic Reed) Electrical Design Life Cycles 1,000,000 at max. rated load, 200,000 at max. rated load (Logic Reed) Mechanical Ratings Vibration 10 2000 Hz 1.52 mm displacement (peak-to-peak) Max./10 G Max. (except Logic Reed) Shock 1/2 cycle sine wave for 11 ms 25 G (contact fragility) and no damage at 100 G Degree of Protection Type 7 & 9 Explosion Proof (Type 3 and Type 4 ratings available with accessories) Mechanical Design Life Cycles Push uttons 250,000 minimum Potentiometers 100,000 minimum ll other devices 200,000 minimum Contact peration Shallow and Mini Contact locks: Slow double make and break Logic Reed & Sealed Switch Contact locks: Snap-action Typical perating Forces Flush, Extended, Standard Mushroom, Jumbo Mushroom: 2.9 lbs Max. perators without contact blocks: Jumbo and Extended luminum Mushroom Head: 3.95 lbs maximum Maintained Selector Switch: 4.0 in.-lbs maximum Spring Return Selector Switches: 5 in.-lbs to stop, 0.2 in.-lbs to return Illuminated Push uttons and Push-to-Test Pilot Lights 5.6 lbs maximum 2-Position Push-Pull 9 lbs maximum push or pull 3-Position Push-Pull 12 lbs maximum push to in position or pull to center position (15 lbs maximum pull to out position) 800T- 1lb Contact locks: Logic Reed 1lbmaximum Sealed Switch 3 lbs maximum at 0.205" plunger travel Stackable Sealed Switch 1lbmaximum Environment Temperature Range perating 4 +131 F ( 20 +55 C) Storage 40 +185 F ( 40 +85 C) Note: perating temperatures below freezing are based on the absence of freezing moisture and liquids. Humidity 50% at +104 F (+40 C) ➊ Performance Data See Page Important-2. Standard Contact Ratings Maximum thermal continuous current I th 10 C/2.5 DC. ulletin 800H Type 7 & 9 units with 800T- contacts have ratingsasfollows: Max. prtnl. Volts Ue Utilization Category Rated perational Currents IEC NEM Volts Ue Make reak 120 600 7200 V 720 V 72 120 60 720 V 24 28 ➋ 60 10 C 600 C-15 600 DC 600 DC-13 Q600 28 600 24 28 ➋ 69 V 2.5 ➋ For applications below 24V and 24 m, PenTUFF, Logic Reed or stackable sealed switch contacts are recommended. Sealed Switch Contact Ratings Maximum continuous current I th 2.5. Max. prtnl. Utilization Category Rated perational Currents Volts Ue IEC NEM Volts Ue Make reak 120 600 3600 V 360 V C 600 C-15 600 0 120 30 3 DC 300 DC-13 P300 24 300 0 24 138 V 5.0 Stackable Sealed Switch Contact Ratings Maximum continuous current I th 3. ulletin 800T units have control circuit ratings with sealed switch contact blocks as follows: Logic Reed Contact Ratings Maximum: 150V C, 0.15, 8 V and 30V DC, 0.06, 1.8 V. Should only be used with resistive loads. PenTUFF (Low Voltage) Contact Ratings Minimum DC: 5V, 1 m Maximum thermal continuous current I th 2.5 C/1.0 DC. ulletin 800H units with 800T-V contacts have ratings as follows: Max. pertnl. Utilization Category Rated perational Currents Volts Ue IEC NEM Volts Ue Make reak C 300 C-15 C300 120 300 1800 V 180 V 0 120 15 1.5 DC 150 DC-13 R150 24 150 28 V 0 24 1.0 pprovals Enclosures: UL Listed Devices: UL Listed Stations: CS File: File: E71673 Guide: NNNY File: E10314 Guide: NIV LR11924 1 Max. prtnl. Utilization Category Rated perational Currents Volts Ue IEC NEM Volts Ue Make reak C 300 C-15 C300 120 300 1800 V 180 V 0 120 15 1.5 DC 150 DC-13 Q150 24 150 69 V 0 24 2.5 10-113

Complete ssembled Stations (Supplied with 3/4" Dead End Conduit Entry) Photo perator Contact Symbol Legend Marking Lever Type ctuator ➊ Cat. No. Component Type uttons ➋ Cat. No. STP 800H-1H7 800H-1H7P Cat. No. 800H-1H7 (1/2 Lever Momentary) ne Push utton 1N..- 1N.C. STRT 800H-1H7 800H-1H7P JG 800H-1HJ7 800H-1HJ7P No Legend Plate supplied. 800H-1H7 800H-1H7P STRT-STP 800H-2H7 800H-2H7P Cat. No. 800H-2H7P (Full Lever Momentary) Two Push uttons Each utton 1N..- 1N.C. FR-REV 800H-2H7 800H-2H7P RISE-LWER 800H-2HD7 800H-2HD7P PEN-CLSE 800H-2HF7 800H-2HF7P No Legend Plate supplied. 800H-2H7 800H-2H7P STRT-STP 800H-2HM 7 0 (Full Lever Maintained) 2-Position Selector Switch 1N..- 1N.C. N-FF 800H-2HCM 7 800H-R2HC7 PEN-CLSE 800H-2HGM 7 800H-R2HG7 RUN-STP 800H-2HJM7 HND-UT 800H-2HLM7 800H-R2H7 Cat. No. 800H-2HM7 No Legend Plate supplied. 800H-2HM7 800H-R2H7 HND-FF-UT 800H-R3H7 3-Position Selector Switch 1N..- 1N.C. No Legend plate supplied. 800H-R3H7 Cat. No. 800H-R3H7 Dual Push utton 120V C/DC Full Volt./ STRT-STP 800H-2HD10R7 Cat. No. 800H-2HD10R7 ne Pilot light 1N..- 1N.C. Marking other than listed consult your local llen-radley Sales ffice. 800H-2HD10R7 ➊ perators have integral padlocking attachment. ➋ STP is extended red, STRT is flush green, all others are flush black. Legend Plates Page 10-142 pproximate Dimensions Page 10-144 llen-radley Spares 10-114

Complete ssembled Stations Lever Type ctuators ulletin 800H 1H 2H 3H J a No. of perators 1 perator 2 perator 3 perator b Legend Marking 1perator(1-Gang) STP STRT JG No Legend 2perator(1-Gang) STRT STP FR REV 800H 2H 7 a b c d e f D F G J K L C D F G b (cont d) Legend Marking 2perator(1-Gang) RISE LWER PEN CLSE JG STP RUN STP JG RUN HND UT No Legend 3perator(2-Gang) FR REV STP UP DWNSTP PEN CLSE STP FST SLW STP STRT JG STP No Legend c Pilot Light ption (2-Gang) R P Y V F H J No Pilot Light Required 120V Full Voltage 240V Full Voltage 480V Transformer 600V Transformer 120V Full Voltage 240V Full Voltage 480V Transformer K 600V Transformer Note: vailable with 1 or 2 operators only. ecomes a 2-Gang station. d Station Type 7 Type 7 & 9 M7 MY7 2 utton Maintained Momentary/Maintained R ➊ K ➊ S M1 M2 e Station ptions ccessories No ptions Sealing Well with Type 3 Flange Sealing Well Type 3 Flange Seal f 1-Gang Conduit ptions 3/4" Dead End 3/4" Feed Through 1" Dead End M3 1" Feed Through Multi-Gang Conduit ptions M3 1" Dead End 1" Feed Through Complete ssembled Stations Push utton Type ctuators 1H 2H 3H R2H R3H 2H J a No. of Push uttons 1 Push utton 2 Push utton 3 Push utton 2-Position Selector 3-Position Selector Dual Push utton b Legend Markings 1 Push utton (1-Gang) STP () STRT () JG No Legend 800H 2H R 7P a b c d e f D F G K C D F G C G K b (cont d) Legend Markings 2 Push uttons (1-Gang) STRT STP FR REV RISE LWER PEN CLSE JG STP JG RUN No Legend 3 Push uttons (2-Gang) FR REV STP UP DWNSTP PEN CLSE STP FST SLW STP STRT JG STP No Legend 2-Position Selector (1-Gang) HND UT FR REV FF N PEN CLSE JG RUN G D D 10R b (cont d) Legend Markings 3-Position Selector (1-Gang) HND FF UT FRWRD FF REVERSE PEN FF CLSE No Legend Dual Push utton (1-Gang) STRT STP Legend c Pilot Light ption Dual Push utton/pilot Light 120V Full Voltage 20R 240V Full Voltage 2 Push utton/pilot Light ➋ R P Y V F H G K No Pilot Light Required 120V Full Voltage 240V Full Voltage 480V Transformer 600V Transformer 120V Full Voltage 240V Full Voltage 480V Transformer 600V Transformer d Station Rating 7P Type 7 & 9 7 W R ➊ K ➊ S M1 M2 M3 Type 7 & 9 Selector Stations or Dual perator Station e Station ptions ccessories No ptions Padlocking ttachment on Stop utton Sealing Well with Type 3 Flange Standard Sealing Well Type 3 Flange Seal f Conduit ptions 3/4" Dead End 3/4" Feed Through 1" Dead End 1" Feed Through 1 ➊ Sealing wells should only be used on stations having 1" conduit entries. ➋ 2-gang station. 10-115

Momentary Contact Push utton Units, Non-Illuminated Flush Head Unit Cat. No. 800H-P1 Extended Head Unit Cat. No. 800H-P6 Mushroom Head Unit Cat. No. 800H-DP6 Contact Type No Contact 1N.. 1N.C. 1N..-1N.C. utton lack lack lack lack Flush Head Extended Head Mushroom Head Cat. No. Cat. No. Cat. No. 800H-P1 800H-P2 800H-P1D1 800H-P2D1 800H-P1D2 800H-P2D2 800H-P1 800H-P2 800H-P1 800H-P2 800H-P6 800H-P1D1 800H-P2D1 800H-P6D1 800H-P1D2 800H-P2D2 800H-P6D2 800H-P1 800H-P2 800H-P6 800H-DP1 800H-DP2 800H-DP6 800H-DP1D1 800H-DP2D1 800H-DP6D1 800H-DP1D2 800H-DP2D2 800H-DP6D2 800H-DP1 800H-DP2 800H-DP6 2N..-2N.C. lack 800H-P1 800H-P2 800H-P1 800H-P2 800H-P6 800H-DP1 800H-DP2 800H-DP6 0 Dual Push utton Units Dual Push utton Unit Cat. No. 800H-DPH1664 Contact rrangement Legend Marking Type Contacts Left Right 2N..-2N.C. STRT (Flush/) N (Flush/lack) PEN (Flush/lack) UP (Flush/lack) (Flush/lack) STP (Extended/) FF (Flush/lack) CLSE (Flush/lack) DWN (Flush/lack) (Flush/lack) Cat. No. 800H-DPH1664 800H-DPH2250 800H-DPH2257 800H-DPH2266 800H-DPH22 ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-116

Momentary Contact Push utton Units, Non-Illuminated ulletin 800H 800 H P 1 a b c d e H HL P P DP DP a arrel Type Standard arrel Length Long arrel b perator Type Flush Head Extended Head Mushroom Head Mushroom Head less Cap c Cap Used only when ordering perator Type DP 1 2 lack 3 range 4 Gray 6 7 lue 9 Yellow J d Special Mushroom Head No Special Head Jumbo Mushroom Head Plastic L Jumbo Mushroom Head Metal Note: Special Mushroom Head options only apply to Mushroom Head operator Type DP. D1 D2 D5 D6 2 4 H C D1V D2V V V HV CV e Contact lock(s) ➊ Standard No Contacts 1 N.. 1 N.C. 1 N.. (Mini) 1 N.C. (Mini) 2 N.. 2 N.C. 1 N.. - 1 N.C. 2 N.. - 2 N.C. 3 N.. - 3 N.C. 4 N.. - 4 N.C. PenTUFF (Low Voltage) 1 N.. 1 N.C. 1N..-1N.C. 2N..-2N.C. 3N..-3N.C. 4N..-4N.C. Dual Push utton Units 1 800 H DP H 16 64 a b c d e f H HL DP H a arrel Type Standard arrel Long arrel b perator Type Dual Push utton c Mounting Horizontal Vertical d of utton 16 Left Flush/Right Extended 22 Left lack Flush/Right lack Flush e Contact lock(s) Left utton for Horizontal Top utton for Vertical Contact rrangement Right utton for Horizontal ottom utton for Vertical 1N..-1N.C. 1N..-1N.C. 2N..-2N.C. 2N..-2N.C. f Marking Left utton for Horizontal Top utton for Vertical No Mark Specified Right utton for Horizontal ottom utton for Vertical No Mark Specified 64 STRT STP 50 N FF 51 FRWRD REVERSE 57 PEN CLSE 66 UP DWN 99 ➋ Marking Specified Marking Specified ➊ For sealed switch and Logic Reed contact blocks, refer to the 800T section, page 10-10. ➋ To order with special marking, specify marking; seven characters maximum per button, single line only. 10-117

Momentary Contact Push utton Units, Illuminated 0 Type Lamp Volts Full Voltage Transformer Full Voltage Transformer Potentiometer Units Incandescent LED 120 C 24 C/DC 120 C 120 C 24 C/DC 120 C Extended Head with Guard Cat. No. 800H-PP16R mber mber mber mber mber mber Extended Head with Guard Cat. No. 800H-QP10R 800H-QP10G 800H-QP10 800H-QP24R 800H-QP24G 800H-QP24 800H-PP16R 800H-PP16G 800H-PP16 800H-QPH10R 800H-QPH10G 800H-QPH10 800H-QPH24R 800H-QPH24G 800H-QPH24 800H-PPH16R 800H-PPH16G 800H-PPH16 Potentiometer Unit Cat. No. 800H-UP24 Potentiometer Potentiometer Resistance Resistance Cat. No. Cat. No. perator nly 2500 Ω 800H-UP19 800H-NP37 (without Resistive Element) 5000 Ω 800H-UP24 1000 Ω 800H-UP13 10 kω 800H-UP29 ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-118

Momentary Contact Push utton Units, llluminated ulletin 800H 800 H PP H 16 R a b c d e f H HL PP QP RP a perator Type Standard arrel Length Long arrel b Power Module Type Transformer (or Dual Input) Full Voltage (or Resistor) Neon ➊ F H F H D DH T TH c d e Illumination ptions Transformer Standard Pilot Light Flashing Lamp ➋ LED ➌ Full Voltage Standard Pilot Light Flashing Lamp ➋ LED ➌ Resistor No ptions Neon No ptions Dual Input Diode Type ➍ Diode Type LED ➌➍ Transformer Relay Type Transformer Relay Type LED ➌ Voltage Transformer 36 48V C 50/60 Hz 16 120V C 50/60 Hz 26 240V C 50/60 Hz 76 277V C 50/60 Hz 46 480V C 50/60 Hz 56 600V C 50/60 Hz Full Voltage 06 6V C/DC 12 12V C/DC 24 24V C/DC 32 32V C/DC ➎ 48 48V C/DC 13 130V C/DC ➎ 10 120V C/DC ➏ 20 240V C/DC ➎ Resistor 11 120V C/DC Resistor Neon 10 120V C/DC 20 240V C/DC Dual Input 16 120V C 24 24V C/DC ➐ C G R W D1 D2 2 4 D1V D2V Lens f No Lens, No Contact lock No Lens if ordering any Contact lock D1-7 mber lue Clear White Contact lock(s) Standard 1N..-1N.C. 1 N.. 1 N.C. 2 N.. 2 N.C. PenTUFF (Low Voltage) 1 N.. 1 N.C. V 1N..-1N.C. Note: For Sealed Switch and Logic Reed contact blocks, refer to the 800T Section, page 10-17. 1 ➊ Neon is only available in amber or clear. ➋ Flashing lamps are only available in 6V full voltage units and all transformer units. ➌ LEDs available in red, green, amber, blue, and white. White LEDs only available in 6V and 24V full voltage and all transformer units. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. ll LEDs except 120V have an internal shunt resistor for use with solid-state outputs. ➍ Diode type dual input provides circuit isolation via opposing diodes. Not recommended for use with solid-state outputs and neon indicators. ➎ 32V and 130V are LED only. 240V is incandescent only. ➏ 120V LED is C only and does not contain internal shunt resistor. For C/DC and internal shunt resistor, order 130V C/DC LED ( 13). ➐ Dual input diode only. 10-119

2-Position Push-Pull Units, Non-Illuminated 2-Position Push-Pull Cat. No. 800H-FP65 perator Position Contact Type Note: = Closed/ = pen N.C.L. N..- N.C.L.. N.C.L..- N.C.L.. utton Push-Pull Maintained Maintained ut In Cat. No. 800H-FP6D4 800H-FP61 800H-FP65 3-Position Push-Pull Units, Non-Illuminated 0 3-Position Push-Pull Cat. No. 800H-FPM67 perator Position Contact Type N.C.- N.C.L.. Momentary Maintained Maintained utton Push-Pull ut Center In Cat. No. 800H-FPM67 perator Position Contact Type Note: = Closed/ = pen N.C.- N.C.L.. Momentary Maintained Momentary utton Push-Pull ut Center In Cat. No. 800H-FPN67 ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-120

2-Position Push-Pull Units, Non-Illuminated ulletin 800H 800 H FP 1 1 a b c d e H HL FP J a arrel Type Standard arrel Length Long arrel b perator Type Push-Pull Unit c Head Type Mushroom Head Jumbo Mushroom Head ➊ d Cap No Cap 1 2 lack 4 Gray (Silver) 6 7 lue 9 Yellow(Gold) e Contact lock(s) perator Position Standard ut In No Contacts 1 5 1N..- 1 N.C.L.. ➊ 2 N.C.L.. ➊ D1 1 N.. D4 1 N.C.L.. ➊ PenTUFF (Low Voltage) perator Position ut In D1V 1 N.. V Note: = Closed/ = pen. 1 N.. - 1 N.C. 3-Position Push-Pull Units, Non-Illuminated 800 H FP M 1 7 a b c d e f 1 H HL FP J a arrel Type Standard arrel Length Long arrel b perator Type Push-Pull Unit c Head Type Mushroom Head Jumbo Mushroom Head ➋ d perator Function perator Position ut Center In M Momentary Maintained Maintained N Momentary Maintained Momentary e Cap No Cap 1 2 lack 4 Gray(Silver) 6 7 lue 9 Yellow(Gold) f Contact lock(s) perator Position Standard ut Ctr. In No Contacts 1N..- 1N.C. 1 7 V PenTUFF (Low Voltage) perator Position ut Ctr. In Note: = Closed/ = pen. 1N..- 1 N.C.L.. 1N.C.- 1 N.C.L.. 1N..- 1N.C. ➊ Normally closed late break contact. When button is pushed from the UT to the IN position, the mechanical detent action of the operator occurs before electrical contacts change state. When the button is pulled from the IN to the UT position, the electrical contacts change state before the mechanical detent occurs. ➋ Not valid with color cap option (no cap). 10-121

2-Position Push-Pull Units, Illuminated Type Lamp Volts Full Voltage Transformer Full Voltage Transformer Incandescent LED Note: = Closed/ = pen Illuminated 2-Position Push-Pull Cat. No. 800H-FPP16R1 perator Position Maintained Maintained Push-Pull Contacts ut In Cat. No. 120 C N.. - 800H-FPQ10R1 24 C/DC N.C.L.. 800H-FPQ24R1 120 C N.. - 800H-FPP16R1 240 C N.C.L.. 800H-FPP26R1 120 C N.. - 800H-FPQH10R1 24 C/DC N.C.L.. 800H-FPQH24R1 120 C N.. - 800H-FPPL16R1 240 C N.C.L.. 800H-FPPL26R1 0 3-Position Push-Pull Units, Illuminated Illuminated 3-Position Push-Pull Cat. No. 800H-FPMP16R7 perator Position perator Position Momentary Maintained Maintained Momentary Maintained Momentary Contacts ut Center In Contacts ut Center In N.C. - N.C.L.. N.C. - N.C.L.. Push-Pull Push-Pull Type Lamp Volts Cat. No. Cat. No. 120 C 800H-FPMQ10R7 800H-FPNQ10R7 Full Voltage Incandescent 24 C/DC 800H-FPMQ24R7 800H-FPNQ24R7 Transformer 120 C 800H-FPMP16R7 800H-FPNP16R7 120 C 800H-FPMQH10R7 800H-FPNQH10R7 Full Voltage LED 24 C/DC 800H-FPMQH24R7 800H-FPNQH24R7 Transformer 120 C 800H-FPMPL16R7 800H-FPNPL16R7 Note: = Closed/ = pen ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-122

2- and 3-Position Push-Pull Units, Illuminated ulletin 800H 800 H FP PH 16 R 1 a b c d e f g H HL FP a arrel Type Standard arrel Length Long arrel b perator Type Push-Pull Unit c perator Function 2-Position Push-Pull T Push-Pull/Twist 3-Position perator Position ut Ctr. In M N Momentary Maintained d e f Illumination ptions Transformer P Standard Incandescent PF Flashing Lamp ➊ PH LED ➋ Full Voltage Q Standard Incandescent QF Flashing Lamp ➊ QH LED ➋ Resistor Incandescent Q Lamp Neon R Neon Lamp ➌ Dual Input D Dual Input Diode ➍ DH Dual Input Diode Type LED ➍➋ Dual Input DT Transformer Relay Dual Input Transformer DTH Relay LED ➋ Voltage Transformer 36 48V C 50/60 Hz 16 120V C 50/60 Hz 26 240V C 50/60 Hz 76 277V C 50/60 Hz 46 480V C 50/60 Hz 56 600V C 50/60 Hz Full Voltage 06 6V C/DC 12 12V C/DC 24 24V C/DC 32 32V C/DC ➏ 48 48V C/DC 13 130V C/DC ➏ 10 120V C/DC ➎ 20 240V C/DC ➏ Resistor 11 120V C/DC Resistor Neon 10 120V C/DC 20 240V C/DC Dual Input 16 120V C 24 24V C/DC ➑ C G R W Cap No Cap mber lue Clear White g Contact locks Standard No Contacts D1 1 N.. D4 1 N.C.L.. ➐ 1 N.. - 1 N.C. 1 1N..- 1 N.C.L.. ➐ 2 2 N.. 5 2 N.C.L.. 7 1N.C.- 1 N.C.L.. ➐ PenTUFF (Low Voltage) D1V 1 N.. D2V 1 N.C. V 1N..-1N.C. D1R D2R R 2R 4R Logic Reed 1 N.. 1 N.C. 1N..-1N.C. 2 N.. 2 N.C. 1 Table 1. Target Selection g, V, R 1 2 5 2-Position 3-Position Contact ut In ut Ctr. In N.. N.C. N.. N.C.L.. N.. N.. N.C.L. N.C.L. N.C. N.C.L.. g, V, R D1,D1V,D1R N.. D4 N.C.L.. 1 7 ➊ Flashing lamps are only available in 6V full voltage units and all transformer units. ➋ LEDs available in red, green, amber, blue, and white. White LEDs only available in 6V and 24V full voltage and all transformer units. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. ll LEDs except 120V have an internal shunt resistor for use with solid-state outputs. ➌ Neon is only available in amber or clear. ➍ Diode type dual input provides circuit isolation via opposing diodes. Not recommended for use with solid-state outputs and neon indicators. ➎ 120V LED is C only and does not contain internal shunt resistor. For C/DC and internal shunt resistor, order 130V C/DC LED ( 13). ➏ 32V and 130V are LED only. 240V is incandescent only. ➐ Normally closed late break contact. When button is pushed from the UT to the IN position, the mechanical detent action of the operator occurs before electrical contacts change state. When the button is pulled from the IN to the UT position, the electrical contacts change state before the mechanical detent occurs. ➑ Dual input diode only. 10-123

2-Position Selector Switch Units, Non-Illuminated Standard Knob perator Cat. No. 800H-HP2K6 Contact Type perator Position No Contacts 1N.. 1 N..- 1N.C. 2 N..- 2N.C. perator Type M = Maintained S = Spring Return Knob Lever perator Cat. No. 800H-HP17K6 Metal Wing Lever perator Cat. No. 800H-HP11K Standard Knob Knob Lever Wing Lever Cat. No. Cat. No. Cat. No. M M 800H-HP2K6 800H-HP17K6 800H-HP11K6 S M ➊ 800H-HP4KL8 800H-HP18KL8 800H-HP15KL8 M M 800H-HP2K6D 800H-HP17K6D 800H-HP11K6D S M ➊ 800H-HP4K6D 800H-HP18K6D 800H-HP15K6D M S 800H-HP5KL8D 800H-HP19KL8D 800H-HP16KL8D M M 800H-HP2K6 800H-HP17K6 800H-HP11K6 S M ➊ 800H-HP4KL8 800H-HP18KL8 800H-HP15KL8 M S 800H-HP5KL8 800H-HP19KL8 800H-HP16KL8 M M 800H-HP2K6 800H-HP17K6 800H-HP11K6 S M ➊ 800H-HP4KL8 800H-HP18KL8 800H-HP15KL8 M S 800H-HP5KL8 800H-HP19KL8 800H-HP16KL8 0 Note: = Closed/ = pen Contact Type Note: = Closed/ = pen perator Position No Contacts 1N.. 1 N..- 1N.C. 2 N..- 2N.C. perator Type M = Maintained S = Spring Return 2-Position Cylinder Lock perator Cat. No. 800H-HP31K6 Cylinder Lock Key Removal Left ➋ Key Removal Right ➋ Key Removal oth ➋ Cat. No. Cat. No. Cat. No. M M 800H-HP31K6 800H-HP32K6 800H-HP33K6 M S 800H-HP48KL8 M M 800H-HP31K6D 800H-HP32K6D 800H-HP33K6D S M ➊ 800H-HP42KL8D M S 800H-HP48KL8D M M 800H-HP31K6 800H-HP32K6 800H-HP33K6 S M ➊ 800H-HP42KL8 M S 800H-HP48KL8 M M 800H-HP31K6 800H-HP32K6 800H-HP33K6 S M ➊ 800H-HP42KL8 M S 800H-HP48KL8 ➊ Target tables are reversed from those shown. ➋ Key removable from maintained positions only. ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-124

2-Position Selector Switch Units, Non-Illuminated ulletin 800H 800 H HP 2 K6 (Knob/Wing Lever) a b c d e f 800 H HP 31 K6 (Cylinder Lock) a b c 1 d 1 e f arrel Type H Standard arrel Length HL Long arrel a b Number of Positions HP 2-Position Knob Insert s ➊ White C lue E Yellow F range PacketofedInserts➋ Metal Wing Lever s Gray c c 1 Key Removal Position Maintained perator Function 31 Key Removal Left 32 Key Removal Right 33 Key Removal oth Spring Return From Left perator Function 42 Key Removal Right ➌ Spring Return From Right perator Function 48 Key Removal Left d perator Type and Function Standard Knob perator Function 2 Maintained 4 Spring Return From Left ➌ 5 Spring Return From Right Knob Lever perator Function 17 Maintained 18 Spring Return From Left ➌ 19 Spring Return From Right Metal Wing Lever perator Function 11 Maintained 15 Spring Return From Left ➌ 16 Spring Return From Right DSeries Key No. d 1 ptional Keys TSeries Key No. D018 (Std. Key) 15 T112 03 D020 16 T115 04 D025 17 T324 05 D335 18 T382 06 D429 19 T404 07 D461 20 T171 08 D111 21 T484 09 D587 22 T547 10 D682 23 T569 11 D713 24 T692 12 D900 25 T752 13 D992 26 T178 14 D118 K6 KL8 Contact Configuration e Cam ption Cam for maintained operators Cam for spring return operators f Contact lock(s) Standard 2-Position No Contacts D 1 N.. E 1 N.C. M N 2 N.. 2 N.C. 1 N.. - 1 N.C. 2N..- 2N.C. PenTUFF (Low Voltage) Contact Configuration 2-Position H 1 N.. U 1 N.C. F FF 1N..-1N.C. 2N..- 2N.C. Note: = Closed/ = pen. 1 ➊ Each standard and knob lever operator is factory assembled with a white insert. ther colors are available, factory assembled, if ordered in quantities of 10 or more. ➋ Packet of colored inserts, one of each color except orange. ➌ Target tables are reversed from those shown. 10-125

3-Position Selector Switch Units, Non-Illuminated Standard Knob perator Cat. No. 800H-JP2K7 Contact Type perator Position perator Type M = Maintained S = Spring Return Knob Lever perator Cat. No. 800H-JP17K7 Metal Wing Lever perator Cat. No. 800H-JP11K7 Standard Knob Knob Lever Metal Wing Lever Cat. No. Cat. No. Cat. No. M M M 800H-JP2K7 800H-JP17K7 800H-JP11K7 No Contacts 1N..- 1 1N.C. S M M 800H-JP4K7 800H-JP18K7 800H-JP15K7 M M S 800H-JP5K7 800H-JP19K7 800H-JP16K7 S M S 800H-JP91K7 800H-JP20K7 800H-JP141K7 M M M 800H-JP2K7 800H-JP17K7 800H-JP11K7 S M M 800H-JP4K7 800H-JP18K7 800H-JP15K7 M M S 800H-JP5K7 800H-JP19K7 800H-JP16K7 S M S 800H-JP91K7 800H-JP20K7 800H-JP141K7 0 2N..- 2N.C. M M M 800H-JP2K7 800H-JP17K7 800H-JP11K7 S M M 800H-JP4K7 800H-JP18K7 800H-JP15K7 M M S 800H-JP5K7 800H-JP19K7 800H-JP16K7 S M S 800H-JP91K7 800H-JP20K7 800H-JP141K7 Note: = Closed/ = pen Contact Type No Contacts perator Position perator Type M = Maintained S = Spring Return 3-Position Cylinder Lock perator Cat. No. 800H-JP42K7 Cylinder Lock Key Removal Left Key Removal Center Key Removal ll ➊ Cat. No. Cat. No. Cat. No. M M M 800H-JP41K7 800H-JP42K7 800H-JP44K7 S M M 800H-JP50K7 800H-JP51K7 M M S 800H-JP69K7 800H-JP38K7 800H-JP73K7 S M S 800H-JP631K7 M M M 800H-JP41K7 800H-JP42K7 800H-JP44K7 S M M 800H-JP50K7 800H-JP51K7 1N..- M M S 800H-JP69K7 800H-JP38K7 800H-JP73K7 1N.C. S M S 800H-JP631K7 Note: = Closed/ = pen ➊ Key removable in maintained positions only. ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-126

3-Position Selector Switch Units, Non-Illuminated 800 H JP 2 K7 (Knob/Wing Lever) a b c d e f ulletin 800H 800 H JP 41 K7 (Cylinder Lock) H HL a b c 1 d 1 e f a arrel Type Standard arrel Length Long arrel b Number of Positions JP 3-Position C E F c Knob Insert s ➊ White knob insert or Cylinder Lock perator lue Yellow range Packet of ed Inserts ➋ Metal Wing Lever s Gray c 1 Cylinder Lock perators Maintained Position Locking Position 41 Left 42 Center 43 Right 44 ll 45 Left and Center 46 Right and Left 47 Right and Center Spring Return from Left Locking Position 50 Center 52 Right 51 Right and Center Spring Return from Right Locking Position 69 Left 38 Center 73 Left and Center Table 1. Selector Switch Cam Targets Spring Return from oth Locking Position 631 Center d Knob/Lever Type perators Standard Knob perator Function 2 Maintained 4 Spring Return from Left 5 Spring Return from Right 91 Spring Return from oth Knob Lever perator Function 17 Maintained 18 Spring Return from Left 19 Spring Return from Right 20 Spring Return from oth Metal Wing Lever ➌ perator Function 11 Maintained 15 Spring Return from Left 16 Spring Return from Left 141 Spring Return from oth d 1 perator Type/Function ➌ Standard Knob Key No. D018 (Standard Key) Note: Refer to page 10-125 for additional key option codes. e Cam ption Standard Cam K7 K7 (See Table 1) K1 Cam K1 (See Table 1) K7 Cam K7 (See Table 1) Note: For additional Cam descriptions, see Table 1. Contact lock ption No Contacts f 2 contact targets for a given cam as shown in the W (white side) column of Table 1. 2 contact targets for a given cam as shown in the W (white side) column of Table 1 and 2 contact targets for the same cam as shown in the (black side) column of Table 1. (1-800T- Contact lock per side. 2 Contact locks total.) 4 contact targets for a given cam as shown in the W (white side) column of Table 1 and 4 contact targets for the same cam as shown in the (black side) column of Table 1. (2-800T- Contact locks per side. 4 Contact locks total.) 1 Target K7 (std.) Cam K1 K7 KC1 KC7 KE7 ➍ KQ1 KQ7 KR1 KR7 KT1 KT7 KU7 W W W W W W W W W W W W W 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Note: W = White = lack. = Closed/ = pen. For additional targets and overlapping cams, see Publication 800T-2.8. ➊ Each standard and knob lever operator is factory assembled with a white insert. ther colors available, factory assembled, if ordered in quantities of 10 or more. ➋ Packet of colored inserts, one of each color except orange. ➌ For additional keys, see page 10-125. ➍ Wing levers are not suitable with KE7 cam code. 10-127

4-Position Selector Switch Units, Non-Illuminated Standard Knob perator Cat. No. 800H-NP2KF4 Knob Lever perator Cat. No. 800H-NP17KF4 Metal Wing Lever perator Cat. No. 800H-NP11KF4 Contact Type No Contacts perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever Metal Wing Lever Cat. No. Cat. No. Cat. No. M M M M 800H-NP2KF4 800H-NP17KF4 800H-NP11KF4 S M M M 800H-NP3KF4 800H-NP29KF4 800H-NP13KF4 M M M S 800H-NP9KF4 800H-NP30KF4 800H-NP14KF4 2N..- 2N.C. M M M M 800H-NP2KF4 800H-NP17KF4 800H-NP11KF4 S M M M 800H-NP3KF4 800H-NP29KF4 800H-NP13KF4 M M M S 800H-NP9KF4 800H-NP30KF4 800H-NP14KF4 Note: = Closed/ = pen 0 Contact Type No Contacts perator Position perator Type M = Maintained S = Spring Return Cylinder Lock perator Cat. No. 800H-NP32KF4 Cylinder Lock Key Removal Position 2 Key Removal Position 3 Key Removal ll ➊ Cat. No. Cat. No. Cat. No. M M M M 800H-NP32KF4 800H-NP33KF4 800H-NP61KF4 S M M M 800H-NP132KF4 800H-NP133KF4 800H-NP154KF4 M M M S 800H-NP232KF4 800H-NP233KF4 800H-NP251KF4 2N..- 2N.C. Note: = Closed/ = pen ➊ Key removable in maintained positions only. M M M M 800H-NP32KF4 800H-NP33KF4 800H-NP61KF4 S M M M 800H-NP132KF4 800H-NP133KF4 800H-NP154KF4 M M M S 800H-NP232KF4 800H-NP233KF4 800H-NP251KF4 ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-128

4-Position Selector Switch Units, Non-Illuminated 800 H NP 2 KF4 (Knob/Wing Lever) a b c d e f ulletin 800H 800 H NP 31 KF4 (Cylinder Lock) a b c 1 d 1 e f H HL a arrel Type Standard arrel Length Long arrel b Number of Positions NP 4-Position C E F c Knob Insert s ➊ White lue Yellow range PacketofInserts➋ Metal Wing Lever s Gray c 1 Key Removal Position and perator Function Maintained 31 32 33 perator Function Key Removal Position 1 Key Removal Position 2 Key Removal Position 3 34 Key Removal Position 4 61 Key Removal ll Positions c 1 (cont d) Key Removal Position and perator Function Spring Return From Position 1 to Position 2 perator Function 132 133 134 Key Removal Position 2 Key Removal Position 3 Key Removal Position 4 Key Removal 154 Positions 2,3, and 4 Spring Return From Position 4 to Position 3 perator Function 231 232 233 251 Key Removal Position 1 Key Removal Position 2 Key Removal Position 3 Key Removal Positions 1,2, and 3 d perator Function and Knob Type Standard Knob perator Function 2 Maintained 3 9 Table 1. Selector Switch Cam Targets Spring Return from Position 1 to Position 2 Spring Return from Position 4 to Position 3 Knob Lever perator Function 17 Maintained 29 30 Spring Return from Position 1 to Position 2 Spring Return from Position 4 to Position 3 d (cont d) perator Function and Knob Type Metal Wing Lever perator Function 11 Maintained 13 14 Spring Return from Position 1 to Position 2 Spring Return from Position 4 to Position 3 d 1 ptional Keys DSeries D018 (Standard Key) Note: Refer to page 10-125 for additional key option codes. KF4 KG4 KK4 KM4 KP4 KH4 e Cam ption F Cam (Standard) G Cam K Cam M Cam P Cam verlapping Cam Contact lock ption No Contacts f 2 contact targets for a given cam as shown in the W (white side) column of Table 1 and 2 contact targets for the same cam as shown in the (black side) column of Table 1. (1-800T- Contact lock per side. 2 Contact locks total) Cam Target KF4 KG4 KK4 KM4 KP4 KH4 ➌ Contact lock Side W W W W W W 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Note: W = White = lack. = Closed/ = pen. For additional targets and overlapping cams, see Publication 800T-2.8. f (cont d) Contact lock ption FF FFFF 4 contact targets for a given cam as shown in the W (white side) column of Table 1 and 4 contact targets for the same cam as shown in the (black side) column of Table 1. (2-800T- Contact locks per side. 4 Contact locks total.) PenTUFF (Low Voltage) 2 contact targets for a given cam as shown in the W (white side) column of Table 1 and 2 contact targets for the same cam as shown in the (black side) column of Table 1. (1-800T-V Contact lock per side. 2 Contact locks total) 4 contact targets for a given cam as shown in the W (white side) column of Table 1 and 4 contact targets for the same cam as shown in the (black side) column of Table 1. (2-800T-V Contact locks per side. 4 Contact locks total.) 1 ➊ Each standard and knob lever operator is factory assembled with a white insert. ther colors available, factory assembled, if ordered in quantities of 10 or more. ➋ Packet of colored inserts, one of each color except orange. ➌ verlapping cam. 10-129

Pilot Light Units Transformer Type Pilot Light Cat. No. 800H-PP16R Push-to-Test Pilot Light Cat. No. 800H-PPT16R Pigtail Pilot Light Cat. No. 800H-LP24R 0 Lamp Type Volts 120 C Full Voltage mber Incandescent 24 C/DC mber Transformer 120 C mber 120 C Full Voltage mber LED 24 C/DC mber Transformer 120 C mber ➊ Includes one standard 800T- (1 N.. - 1 N.C.) contact block. Typical Pilot Light Wiring Diagrams See applicable s and Laws. Push-to-Test Pilot Light Device Schematic NRML 2 1 Pilot Light Push-to-Test➊ Pigtail Cat. No. Cat. No. Cat. No. 800H-QP10R 800H-QP10G 800H-QP10 800H-QP24R 800H-QP24G 800H-QP24 800H-PP16R 800H-PP16G 800H-PP16 800H-QPH10R 800H-QPH10G 800H-QPH10 800H-QPH24R 800H-QPH24G 800H-QPH24 800H-PPH16R 800H-PPH16G 800H-PPH16 800H-QPT10R 800H-QPT10G 800H-QPT10 800H-QPT24R 800H-QPT24G 800H-QPT24 800H-PPT16R 800H-PPT16G 800H-PPT16 800H-QPTH10R 800H-QPTH10G 800H-QPTH10 800H-QPTH24R 800H-QPTH24G 800H-QPTH24 800H-PPTH16R 800H-PPTH16G 800H-PPTH16 R 1 D1 800H-LP10R 800H-LP10G 800H-LP10 800H-LP24R 800H-LP24G 800H-LP24 Dual Input Diode Pilot Device Schematic NRML (3) TEST L 1 4 3 TEST (1) R 2 D2 L 2 (2) Dual Input Pilot Light Typical pplication Wiring Diagram TEST L1 1LS (3) (1) 1CR (2) L2 NRML (3) Dual Input Pilot Light Transformer Type Device Schematic 2LS 3CR PS (3) (1) SL (2) TEST (1) C (3) (1) (2) L 2 (2) ccessories Page 10-137 pproximate Dimensions Page 10-144 Legend Plates Page 10-142 llen-radley Spares 10-130

Pilot Light Units 800 H PP T 16 R a b c d e f H HL PP QP RP LP LPK a arrel Type Standard arrel Length Long arrel b Power Module Type Transformer (or Dual Input) Full Voltage (or Resistor) Neon ➊ Pigtail Full Voltage ➋ Pigtail Full Voltage ➋ (for Dual Push uttons) c Lamp Test ptions No Test ption T Push-to-Test D Dual Input Diode ➌ Dual Input DT Transformer Relay ➌ Note: Push-to-Test Pilot Light is supplied with a factory jumpered 800T-, 1 N. - 1 N.C Contact lock. F H F H F H d e f Transformer Voltage Lens Transformer Standard Pilot Light No Lens Flashing Lamp ➍ 36 48V C 50/60 Hz mber LED ➎ 16 120V C 50/60 Hz lue Full Voltage 26 240V C 50/60 Hz C Clear 76 277V C 50/60 Hz G Standard Pilot Light 46 480V C 50/60 Hz R Flashing Lamp ➍ 56 600V C 50/60 Hz W White LED ➎ Full Voltage Resistor 06 6V C/DC No ptions 12 12V C/DC Neon 24 24V C/DC 32 32V C/DC ➏ No ptions ➊ 48 48V C/DC Dual Input 13 130V C/DC ➏ 10 120V C/DC ➐ No ptions 20 240V C/DC ➏ Pigtail Resistor Standard Pilot Light 11 120V C/DC Resistor Flashing Lamp ➍ Neon LED ➎ 10 120V C/DC 20 240V C/DC Dual Input 1 16 120V C 24 24V C/DC ➑ Pigtail 06 6V C/DC 12 12V C/DC 24 24V C/DC 10 120V C/DC 20 240V C/DC ➊ Neon is only available in amber or clear. ➋ Lamp test options not available with pigtail. ➌ nly available with power module type code PP. ➍ Flashing lamps are only available in 6V full voltage units and all transformer units. ➎ LEDs available in red, green, amber, blue, and white. White LEDs only available in 6V and 24V full voltage and all transformer units. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. ll LEDs except 120V have an internal shunt resistor for use with solid-state outputs. ➏ 32V and 130V are LED only. 240V is incandescent only. ➐ 120V LED is C only and does not contain internal shunt resistor. For C/DC and internal shunt resistor, order 130V C/DC LED ( 13). ➑ Dual input diode only. 10-131

10n/ 0 pplication When properly mounted in a Type 7 & 9 enclosure, ulletin 800H Type 7 & 9 operators are designed to meet the requirements of the National Electrical for Class I, Divisions 1 & 2, Groups, C & D Hazardous Gas; Class II, Divisions 1 & 2, Groups E, F and G Hazardous Dust; and, Class III Hazardous Fiber Locations. In addition, the single gang shallow base, Cat. No. 800H-IHZ7, meets Class I, Group requirements. This Type 7 & 9 equipment is listed by Underwriters Laboratories, Inc. Per National Electrical : Zone 1. In Class I, Zone 1 locations, all wiring methods permitted for Class I, Division 1 locations and Class I, Zone 0 or Zone 1 locations, including requirements for sealing, shall be permitted. Zone 2. In Class I, Zone 2 locations, all wiring methods permitted for Class I, Division 2, Class I, Division 1 or Division 2, and Class I, Zone 0 or Zone 1 locations, including requirements for sealing, shall be permitted. perator Construction The llen-radley line of hazardous location devices feature copper free (less than 0.4 of 1% copper content) die cast aluminum bushings and mounting rings, Type #316 stainless steel operating shafts andan-ringsealforaddedcorrosion resistance. These components mount into a threaded hole (3/4"-14 NPSM) in a suitable enclosure. ulletin 800H Type 7 & 9 components are available in two basic formats: standard barrel (ulletin 800H) and long barrel (ulletin 800HL). Standard barrel devices are suitable for mounting in panel thickness up to 1"; Long barrel devices are suitable for mounting in panel thickness greater than 1" and no thicker than 2-1/2". oth style operators offer a unique locking bracket which provides an anti-turn feature to guard against loosening. The mounting rings in front of the panel are knurled to provide a second means of tightening each unit into the panel. utdoor Use ulletin800htype7& 9 stations and enclosures are not configured for outdoor use as standard. Type 3 rating is available, while maintaining Type 7 & 9 integrity of the enclosure, by the addition of a Type 3 sealing flange and an approved drain. The sealing flange shown below may be purchased as an option (see page 10-115) or as an accessory (see page 10-141). Type 4 rating can be achieved by using sealing nuts to seal the push button operators in addition to using the sealing flange. Sealing nuts are available as accessories (see page 10-141.) Elimination of Conduit Seal ff Requirement ulletin800htype7& 9unitsmaybe installed with a variety of sealing options. y utilizing either a sealing well or flanged sealing well, these stations may be installed without a conduit seal offin most applications (subject to applicable codes and laws). The sealing wells shown below may be purchased as an option (see page 10-115) or as an accessory (see page 10-141). Sealing wells are also available with an integral Type 3 flange seal for outdoor applications. Sealed switch contact blocks are another way to eliminate the need for conduit seal fittings in most applications (subject to applicable codes and laws). Sealed switch contact blocks may be purchased as an option on assembled stations by changing the ulletin No. from 800H to 800R. Sealed switch contact blocks can be ordered as an accessory (see page 10-141). push button station with a sealed switch contact block is shown below. Type 3 Flange Seal Sealing Wells Sealed Switch Contact locks 10-132 llen-radley Spares

rdering Information for Stations Stations ulletin800htype7& 9 stations are available as factory assembled or as components for field assembly. Factory ssembled Stations ulletin800htype7& 9 control stations are designed to meet the requirements of the National Electrical. These stations are listed by Underwriters Laboratories, Inc. for Class I, Divisions 1 & 2, Groups C & D Hazardous Gases or Vapors, Class II, Divisions 1 & 2, Groups E, F & G Hazardous Dust and Class III Hazardous Fiber Locations. In addition the single gang shallow base, Cat. No. 800H-IHZ7, meets Class I, Group requirements as defined in the National Electrical. Factory assembled stations may be ordered in three ways: Standard, factory assembled stations listed on page 10-114. Modified Standard, factory assembled stations can be selected from the configurator on page 10-115. Custom, factory assembled stations canbeorderedbyfollowingthe instructions listed on this page. Components for Field ssembled Stations Eight-gang maximum ➊. These 2- and 3-gang modules may be assembled into the multi-gang stations by installing a coupler kit between the enclosures. These separate bases, covers, or bases with covers are Underwriters Laboratories, Inc. listed when properly assembled. These enclosures meet the requirements of Class I, Division 1 & 2, Groups C & D, Class II, Divisions 1 & 2, Groups E, F & G, and Class III hazardous locations as defined in the National Electrical. ulletin 800H Type 7 & 9 components are designed for these modular enclosures and are Underwriters Laboratories, Inc. listed for this purpose. Note: Components may be assembled as multi-gang units up to an eight-gang maximum ➊. To select components for field assembly, follow the instructions for ordering a custom built station. lso,instep3youmaychoosetoselect the base as components to provide additional design flexibility, see page 10-115. ulletin 800H Instructions for rdering Custom uilt Stations 1. Select operators required from pages 10-116 through 10-131. (If lever type, select covers from page 10-134 and go to Step 3). 2. Select covers based on mounting requirements from page 10-134. 3. Select an assembled base from pages 10-135 through 10-136 in accordance with the number of covers selected in Step 2. 4. Select legend plates from pages 10-142 through 10-143 (and accessories, if required, from pages 10-137 through 10-141). 5. If a particular sequence of operators or mounting orientation (vertical versus horizontal) is required, include a rough sketch. 1 1. Push-to-test pilot lights, illuminated push buttons, push-pull units, 4-position selector switches, all operators with two contact blocks fastened along side one another or with a power module and contact block along side one another must be installed in a single hole cover. 2. Dual push button units may only be installed in a single hole cover or the specially designed two hole cover (Cat. No. 800H-NP33), which can accommodate the dual push button and the special pigtail pilot light (Cat. No. 800H-LPK10R). Station Design Guidelines (lso see pplicable s and Standards) 3. When two components are installed in one cover, contact blocks are restricted to one side of the operator. Contact blocks of each operator must face each other. 4. ne level of contact blocks is maximum in a shallow base or deep basewhenusedwithasealingwell. Contact blocks, except sealed switch type, may be mounted two deep in other bases. 5. If sealed switch contact blocks or a sealing well are used, a deep enclosure is required. 6. a. STRT push buttons should be green or black flush, installed to the left or above STP push buttons. b. EMERGENCY STP push buttons should be a red mushroom. c. STP push buttons should be red extended, installed to the right or below STRT push button. d. STP push buttons should be installed in the last position (bottom or right) of each unit when required. e. Pilot lights should be installed in the first position (top or left side) of each unit when required. ➊ Flange width is designed to comply with Underwriters Laboratories standards to enclosures with an internal free volume of up to 300 cubic inches (a maximum 8-gang assembly). 10-133

Covers, Lever Type ctuator Note:Lever type covers are furnished without contact blocks. Legend plate for half lever is STP; full lever momentary and maintained it is a STRT-STP. STRT STP STP Half Lever Double Lever Momentary Half Lever Double Lever Momentary Double Lever Maintained Double Lever Momentary/Maintained ➊ Cat. No. Cat. No. Cat. No. Cat. No. 800H-NP14 800H-NP15 800H-NP16 800H-NP34 Covers, Component Type utton 0 ne Hole ➋ Two Hole ➌ Two Hole Special ➍ Cat. No. Cat. No. Cat. No. Cat. No. 800H-NP32 800H-NP30 800H-NP31 800H-NP33 Design Guideline #4 ne level of contact blocks is maximum in a shallow base or deep base when used with a sealing well. Contact blocks, except sealed switch type, may be mounted two deep in other bases. Design Guideline #1 Push-to-test pilot lights, illuminated push buttons, push-pull units, 4-position selector switches, all operators with two contact blocks fastened along side one another or with a power module and contact block along side one another must be installed in a single hole cover. Design Guideline #3 When two components are installed in one cover, contact blocks are restricted to one side of the operator. Contact blocks of each operator must face each other. Design Guideline #2 Dual push button units may only be installed in a single hole cover or the specially designed two hole cover (Cat. No. 800H-NP33), which can accommodate the dual Push utton and the special pigtail pilot light (Cat. No. 800H-LPK10R). ➊ normally open circuit configuration is recommended for use behind this momentary lever and a late break normally closed circuit configuration is required for use behind the maintained lever to achieve proper functioning of the device. ➋ ne hole covers use a jumbo legend plate only. ➌ Two hole covers use a standard legend plate only. 10-134 ➍ This special two hole cover can accommodate the pigtail pilot light (ulletin 800H-LPK10 series), the dual push button or any non-illuminated unit. Legend plates (Cat. No. 800H-Y140J green and red split-field) and (Cat. No. 800H-Y141J gray full field), are the only legend plates suitable for use with this cover. llen-radley Spares

ssembled ases (for Field ssembly and Custom Stations) ulletin 800H Enclosure Covers See table on page 10-134 for a complete listing of covers for these bases. Special Conduit Entries For conduit entries not listed, consult your local llen-radley Sales ffice. 1-Gang Shallow ➊ 1-Gang Deep ➋ 2-Gang Horizontal ➋ Conduit Entry Cat. No. Cat. No. Cat. No. 3/4" Dead End 800H-1HZ7 800H-1HV7 3/4" Feed Through 800H-1HV7M1 1" Dead End 800H-1HV7M2 800H-2HH7 1" Feed Through 800H-1HV7M3 1 2-Gang Vertical ➋ 3-Gang Vertical ➋ 4-Gang ➋ Conduit Entry Cat. No. Cat. No. Cat. No. 1" Feed Through 800H-2HY7 800H-3HY7 800H-4HV7 6-Gang ➋ 8-Gang ➋ Conduit Entry Cat. No. Cat. No. 1" Feed Through 800H-6HV7 800H-8HV7 ➊ Shallow base cannot accommodate sealing well, sealed switched contact blocks or stacked contact blocks. Shallow base rated for Group. ➋ Deep base can accommodate sealing well, sealed switch contact blocks or up to 2 deep standard contact blocks. 10-135

ases for Multi-Gang Stations ➊ ➊ ➊ Conduit Sizes Cat. No. Cat. No. Cat. No. 3/4" Feed Through 800H-NP40C 800H-NP41C 800H-NP42 1" Feed Through 800H-NP40D 800H-NP41D 800H-NP42 ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 0 Conduit Sizes Cat. No. Cat. No. Cat. No. Cat. No. 3/4" Feed Through 800H-NP43 800H-NP44 800H-NP45 800H-NP46 1" Feed Through 800H-NP43 800H-NP44 800H-NP46 Example: 7-Gang ase with 1-inch through-feed conduit consists of: 3-Cat. No. 800H-NP42 1-Cat. No. 800H-NP43 1-Cat. No. 800H-NP44 1-Cat. No. 800H-NP45 1-Cat. No. 800H-NP46 6-Cat. No. 800H-NP7 Plus up to 4-1" plugs (Cat. No. 800H-NP11) to close unused conduit openings. Caution: Do not assemble more than 8 enclosure gangs together, to avoid exceeding the internal volume for which the flame path of these enclosures is designed. ➋ ➋ ➋ 800H-NP43 800H-NP44 800H-NP46 800H-NP45 800H-NP42 800H-NP42 ➋ ➋ 800H-NP42 ➋ ➊ When coupling modular enclosures together, a coupler kit (Cat. No. 800H-NP7) is required between enclosures. ➋ 1" conduit through-feed (all gangs). llen-radley Spares 10-136

Modifications and ccessories ulletin 800H Contact locks Packaged in kit form for field installation. ll necessary mounting hardware is provided with each contact block kit. Contact ratings are listed on page 10-113. Note: It is not recommended to mount more than four contact blocks on any one unit (maximum two blocks deep). Sealed switch contact blocks are limited to two blocks per unit maximum. Shallow lock Mini lock PenTUFF (Low Voltage) Contact lock Number of Contacts Shallow lock ➊➋➌ Mini lock ➊➌ PenTUFF (Low Voltage) lock ➊➋➌ Cat. No. Cat. No. Cat. No. 1N.. 800T-D1 800T-D5 800T-D1V 1N.C. 800T-D2 800T-D6 800T-D2V 1 N..E.M. 800T-D3 800T-D3V 1 N.C.L.. 800T-D4 800T-D4V 1N..-1N.C. 800T- 800T-V 2N.. 800T-2 2N.C. 800T-4 1 N.C.L.. - 1 N.. 800T-1 1 N.C.L.. - 1 N.C. 800T-7 1 Logic Reed lock Sealed Switch lock Stackable Sealed Switch lock Number of Contacts Logic Reed lock ➊ Sealed Switch lock ➊ Stackable Sealed Switch lock ➊ Cat. No. Cat. No. Cat. No. 1N.. 800T-D1R 800T-D1P 800T-D1Y 1N.C. 800T-D2R 800T-D2P 800T-D2Y 1N..-1N.C. 800T-R 800T-P 800T-Y 2N.. 800T-2R 800T-2Y 2N.C. 800T-4R 800T-4Y ➊ To determine if a conduit seal-off is necessary, see page 10-141 for sealing well information. ➋ Specify ulletin 800TC for finger-safe contact blocks. Example: 800TC-. ➌ Contact blocks with normally closed contacts meet direct drive positive opening standard requirements. 10-137

Modifications and ccessories, Continued Replacement Caps (Illuminated) mber lue White Clear Pilot Light Cat. No. 800H-N104R Replacement Caps (Non-Illuminated) Pilot Light Push-to-Test Pilot Light Illuminated Push utton Illuminated Push-Pull Cat. No. Cat. No. Cat. No. Cat. No. 800H-N104R 800H-N104G 800H-N104 800H-N104 800H-N104W 800H-N104C Push-to-Test Pilot Light Cat. No. 800H-N105R 800H-N105R 800H-N105G 800H-N105 800H-N105 800H-N105W 800H-N105C Illuminated Push utton Cat. No. 800H-N106R 800H-N106R 800H-N106G 800H-N106 800H-N106 800H-N106W 800H-N106C Illuminated Push-Pull Cat. No. 800H-NP50 800H-NP50R 800H-NP50G 800H-NP50 800H-NP50 800H-NP50W 800H-NP50C 0 lue Yellow lack Gray Momentary Mushroom Standard (Plastic) Cat. No. 800T-N246R Momentary Mushroom Standard (Plastic) Momentary Mushroom Jumbo (Metal) ➊ Push-Pull Standard (Metal) Push-Pull Jumbo (Metal) Cat. No. Cat. No. Cat. No. Cat. No. 800T-N246R 800T-N246G 800T-N246L 800T-N246Y 800T-N246 800T-N246GR Momentary Mushroom Jumbo (Metal) Cat. No. 800T-N248R 800T-N248R 800T-N248G 800T-N248L 800T-N248Y 800T-N248 800T-N248GR Push-Pull Standard (Metal) Cat. No. 800H-NP51C 800H-NP51 800H-NP51 800H-NP51C 800H-NP51E 800H-NP51H 800H-NP51G Push-Pull Jumbo (Metal) Cat. No. 800H-NP52 800H-NP52 800H-NP52 800H-NP52C 800H-NP52E 800H-NP52H Natural 800T-N248 Replacement Knobs and Dual Push utton ssembly Standard Knob Cat. No. 800H-N130F White Kit (Complete) ➌ Gray / Standard Knob Knob Lever Wing Lever ➋ Dual Push utton Cat. No. Cat. No. Cat. No. Cat. No. 800H-N130F 800H-N130 Knob Lever Cat. No. 800H-131F 800H-N131F 800H-N131 Wing Lever Cat. No. 800H-N138 800H-N138 800H-N138 Dual Push utton Cat. No. 800H-NP39 800H-NP39 ➊ To order Plastic Jumbo Caps, contact your local llen-radley Sales ffice. ➋ Standard finish is gray. 10-138 ➌ Kit includes knob and packet of inserts (Cat. No. 800T-N123). Refer to color insert kits on page 10-141. llen-radley Spares

Modifications and ccessories, Continued oots and ooted Knobs ulletin 800H Material Hypalon Silicone Urethane Ethylene Propylene Flush Push utton oot Cat. No. 800H-NP5 lack Yellow lue lack Yellow lue lack Yellow lue lack Yellow lue Flush Push utton oot ➊ flush head push buttons are not suitable for applications requiring extended head, mushroom head or other unguarded buttons capable of being operated quickly in emergencies, and they may not comply with applicable codes or standards. To order a protective boot for a red flush head push button, use the following cat. nos.: Hypalon Cat. No. 800H-NP5; Silicone Cat. No. 800H-NP101R; Urethane Cat. No. 800H-NP100R; Ethylene Propylene Cat. No. 800H-NP103R. ➋ Includes color insert kit. Push utton Guards and Mushroom Push utton Guards Extended Push utton oot ooted Standard Knob Selector Switch ➋ ooted Knob Lever Selector Switch ➋ Cat. No. Cat. No. Cat. No. Cat. No. ➊ 800H-NP5 800H-NP5H 800H-NP5E 800H-NP5C ➊ 800H-NP101G 800H-NP101 800H-NP101Y 800H-NP101L ➊ 800H-NP100G 800H-NP100 800H-NP100Y 800H-NP100L ➊ 800H-NP103G 800H-NP103 Extended Push utton Cat. No. 800H-NPE5 800H-NPE5 800H-NPE5 800H-NPE5H 800H-NPE5E 800H-NPE5C 800H-NPE101R 800H-NPE101G 800H-NPE101 800H-NPE101Y 800H-NPE101L 800H-NPE100R 800H-NPE100G 800H-NPE100 800H-NPE100Y 800H-NPE100L 800H-NPE103R 800H-NPE103G 800H-NPE103 ooted Standard Knob Selector Switch Cat. No. 800H-NP5 800H-NP5 800H-NP101 800H-NP100 800H-NP103 ooted Knob Lever Selector Switch Cat. No. 800H-NPE5 800H-NPE5 800H-NPE101 800H-NPE100 800H-NPE103 1 Cat. No. 800H-NP19 Push uttons, Pilot Lights and Push-to-Test Protective Rings Cat. No. 800H-NP13 Extra Long Guard (1") for Push utton Cat. No. 800H-NP9 Mushroom Cat. No. 800H-NP12 Jumbo Mushroom Cat. No. Cat. No. Cat. No. Cat. No. 800H-NP19 800H-NP13 800H-NP9 800H-NP12 Protective Ring for 2-Position Push-Pull Cat. No. 800H-NP40 Jumbo Protective Ring for 2-Position Push-Pull Cat. No. 800H-NP40J Protective Ring for Illuminated Push uttons Type Cat. No. Protective ring for 800H 2-position push-pull operators. Illuminated or non-illuminated. For standard size button 800H-NP40 ften used to avoid unintentional tripping of E-stop operators. vailable for standard size button (40 mm) or for jumbo button (60 mm). For jumbo size button 800H-NP40J 10-139

General ccessories Plugs Cat. No. Coupler Used for both horizontal and vertical assembly. 800H-NP7 Coupler Cat. No. 800H-NP7 Type Cat. No. Closing Plug Cat. No. 800H-NP1 (perators not included) Closing Plug Whenever an enclosure with more than the required number of cover openings is used, this plug can be used to close the unused openings. Includes synthetic -ring washer. Cover Hole ase Coupling 800H-NP1 800H-NP3 Size Cat. No. 3/4" 800H-NP10 0 Conduit Entry Plug Cat. No. 800H-NP10 (perators not included) Conduit Entry Plug This plug can be used to plug unused conduit openings in Type 7 & 9 bases. 1" 800H-NP11 Locking ttachments Cat. No. Push utton Padlocking ttachments This device permits locking in the depressed position on Extended head push button units only. 800H-NP2 Push utton Padlocking ttachment Cat. No. 800H-NP2 (Padlock not included) Dual Push utton Extended Head Padlocking ttachments This device permits locking for dual push button extended head units only. 800H-NP17 Dual Push utton Extended Head Padlocking ttachment Cat. No. 800T-N10 (Padlock not included) 10-140 llen-radley Spares

General ccessories, Continued Locking ttachments, Continued ulletin 800H Cat. No. Miscellaneous Padlocking Cover Cat. No. 800H-NP4 (Padlock not included) Padlocking Cover Padlocking cover is used for Type 7 & 9 selector switches, non-illuminated push buttons (except mushrooms) and non-illuminated 2-position push-pull units, but not for potentiometer units. Note: Push-pull units will only lock in the depressed position. Padlocking cover includes blank legend plate for customer marking. pre-marked legend plate entitled PEN CVER T PERTE (Front View) and PULL-T-STRT-PUSH-T-STP (Rear View) is available. To order legend plate only, specify Cat. No. 800H-W174L. 800H-NP4 Sealing Well with Flange Seal Cat. No. 800H-NPRD91 Sealing Well without Flange Seal Cat. No. 800H-NPD93 Sealing Well with or without Integral Type 3 Flange Seal These sealing wells should only be used with bases having 1" conduit entries. They reduce costs usually necessary with other conduit seal fittings for most installations (subject to applicable codes and laws) while maintaining Type 7 & 9 integrity. When using a sealing well with integral flange seal for Type 3 outdoor applications, an approved drain fitting must be provided. (Refer to National Electrical.) Style With Integral Flange Seal, Type 3, 7 & 9 Without Integral Flange Seal, Type 7 & 9 No. of Wires Cat. No. 2 800H-NPRD90 4 800H-NPRD91 6 800H-NPRD92 8 800H-NPRD93 2 800H-NPD90 4 800H-NPD91 6 800H-NPD92 8 800H-NPD93 Style Cat. No. 1 Flange Seal 800H-NP20 Flange Seal Cat. No. 800H-NP20 Type 3 Flange Seal This seal provides a Type 3 rating while maintaining Type 7 & 9 integrity. They are used with the llen-radley enclosures listed on page 10-132 for outdoor applications. n approved drain (see listing) is required for condensation when using this option (refer to National Electrical ). For a Type 4 rating, use sealing nuts to seal the push button operators in addition to using the flange seal. Sealing kit is comprised of flange seal and sealing nut. Drain for 3/4" Conduit pening Drain for 1" Conduit pening Type 4 Sealing Nut 800H-NP21 800H-NP22 800H-N479 Drain Plug Cat. No. 800H-NP21 Insert Kit Cat. No. 800H-NP23R Type 4 Sealing Kit 800H-N479F Cat. No. Insert Kit Thesecolorinsertkitsareusedwith illuminated push buttons, pilot lights, push-pull, and push-to-test push buttons (order quantity of 1 to receive kit of 5 inserts). mber lue White neofeachcolor 800H-NP23R 800H-NP23G 800H-NP23 800H-NP23 800H-NP23W 800H-NP23 10-141