SANO. Pinxel Introduction

Similar documents
PINXEL. Micro Needle Rf & Fractional Rf

Chapter 28: The FotoFacial RF Pro Galaxy TM

Next-Generation Fractional CO2 Emerges. Annual Practice Survey Results Review of Autologous Treatments AAD 2011 Exhibitor Highlights THE

MINISILK FT MINISILK FT MEDICINE AND AESTHETICS. DEKA Pulsed Light: Light, Compact, Extremely Versatile

FOR BEAUTY PROFESSIONALS

The Complete CO 2 Solution

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

Leksell Neuro Generator

Surgitron Dual Frequency 4.0 MHz Radiowave Technology

577 nm: The Preferred Wavelength

AC DermaPeptide Toning PF Anti-Wrinkle + Toning + Elasticity

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

Fractional CO2 Laser. Scanxel - Round ROUND SCANNER. Medsun co., ltd.

Better diagnosis and treatment all-in-one.

BEYOND HEAT. Therapeutic Effectiveness Repeatability Safety.

Radio Frequency Electrosurgical System Specialist

Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Sensors. CSE 666 Lecture Slides SUNY at Buffalo

LIGHT THERAPY. Long wavelength. Low frequency. High frequency. Short wavelength. Part 2. General Sciences. application. application. wavelengths.

Brief Explanation About the Laser Hair Removal Treatment

INTELECT SHORTWAVE DIATHERMY MOVING REHABILITATION FORWARD

introducing the M22 success made simple

(12) United States Patent (10) Patent No.: US 6,235,015 B1

RF Amplifiers and RF Heating for Medical Applications FTF-IND-F0690

DIODE LASER PLATFORM Effective+profitable+versatile. diode laser platform DIODE LASER HAIR REMOVAL. termosalud.com/eneka

SCENAR: the secrets of effectiveness. RITM OKB ZAO, M. Unakafov

A Dream to Use. V-Series. Dreamweaver V-Series Sewing, Quilting and Embroidery Machines

High power and biostimulation laser therapy Polaris HP S

Dr.Rajaa CH.11. أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان

The pattern scanning multi-color photocoagulator that puts you in control

troubleshooting LEVEL 1 training

Physics in Modern Medicine Fall 2010

T CaRe ENERGY MADE TO MEASURE

OMEGAMONITOR BOM-L1 TR W

USING THE ARTISTRY SKIN ANALYZER

DIATHERMY UNITS HIGH FREQUENCY HEAT THERAPY:

What is PUK? PUK 3s professional plus PUK 2 and PUK 111

radiosurg One device for all surgical treatments!

Professional LED Light System. Luvis-C100 Luvis-C200 Luvis-S100 Luvis-S200

(12) (10) Patent No.: US 8,357,150 B2 Adanny et al. (45) Date of Patent: Jan. 22, 2013

Andy Falconer. Principles of surgical diathermy

User Manual Model P2a

Ch.2 Optical Properties of Biological Tissues

8791 Power Tube. Linear Beam Power Amplifier Tube

UNDERSTANDING THE BENEFICIAL PROPERTIES OF EARLY ELECTROTHERAPY LEADS TO A NEW PRODUCT CALLED THE TESLA-BRUSH

The Somatosensory System. Structure and function

Fingerprints - Formation - Fingerprints are a reproduction of friction skin ridges that are on the palm side of fingers and thumbs

ifs 150 khz IntraLase Technology

Laser Glasses

ELECTRICAL CURRENT FOR TISSUE HELALING

P6 Quick Revision Questions

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL

SURFACE ANALYSIS STUDY OF LASER MARKING OF ALUMINUM

Furthermore, STJ-3D has a build-in thermistor, allowing the measurement of both temperature and magnetic field to be measured simultaneously.

ELECTRICAL CURRENT FOR PAIN CONTROL

Thanks to an innovative technique, lasers and veterinaries work together. ASAveterinary provides veterinaries with the research and expertise of

Yellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500

NEW MINIMALLY-INVASIVE REJUVENATION METHODS. APTOS Catalogue

Excellent. Stand Out. with Your. Cosmetic Advice. Multi Skin Test Center MC 1000 & Software. moisture, oil, melanin, ph, elasticity & many more

High power and biostimulation laser therapy Polaris HP M

2013 Applied Power Electronics Conference (APEC) Page 1 of 8

GE AMX 4+ Portable X-Ray

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

Electromagnetic Wave Engineering

Physical Therapy. Methods in Physical Therapy. Non-electric heat therapy Therapeutique application of electric current

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

surtron.com SURTRON ELECTROSURGICAL units

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms)

Put the power of the hottest beauty trend to work in your store! TSF NY INC

Marking Cutting Welding Micro Machining Additive Manufacturing

13 February 2017 Inside Cosmetic Surgery Today on WebTalkRadio.net. Interview with Dr Barry Lycka & Dr Charles Crutchfield

Machine Tool Order Intake in Germany Real changes against the previous year in %

LC31L-BAT Link Coupler

Centurion Laser Shower

(a) Imaging Veins Superficial veins that are less than 3 mm deep can sometimes be seen as blue-green (often raised) areas of the skin.

Photoacoustic Imaging of Blood Vessels in Tissue

SD400C..C SERIES 800A. Hockey Puk Version STANDARD RECOVERY DIODES. Features. Typical Applications. Major Ratings and Characteristics

Biophysical Basis of Optical Radiation Exposure Limits. Bruce E. Stuck

(60) Provisional application No. 60/712, 358, filed on Aug. 29, (51) Int. Cl. A618 18/18 A61N 1/00 A61N 5/06 (52) U. S. Cl.

Amateur Radio License. Safety

WRIST ARTHROSCOPY SYSTEM

The Fastest Photocoagulator.

RF Energy in Medicine

EDL Group #3 Final Report - Surface Electromyograph System

LASERS. & Protective Glasses. Your guide to Lasers and the Glasses you need to wear for protection.

Radiofrequency: Principles & Devices

Seismic Simulator (Earthquake)

CARE & MAINTENANCE Tips for the maintanance of Sofacompany furniture

End Capped High Power Assemblies

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

Application Note 175 Using the STMISOC Stimulus Isolator

CABLING AND BRACING. January 1980, Vol. 6, No. 1. by Alex L. Shigo and Robert Felix

(12) Patent Application Publication (10) Pub. No.: US 2013/ A1

Transcutaneous Electrical Nerve Stimulator TENS 212. Instruction Manual. Read before using

paper title : Analyzing the Components of Dark Circle by Nonlinear Estimation of Chromophore Concentrations and Shading

Abstract 2. VARIOUS METHODOLOGIES FOR VIEWING VEINS 1. INTRODUCTION

DESIGN AND IMPLEMENTATION OF EMG TRIGGERED - STIMULATOR TO ACTIVATE THE MUSCLE ACTIVITY OF PARALYZED PATIENTS

4-axis highly reliable and affordably priced Soldering Robot Model 9434

Biomechatronic Systems

Transcription:

Pinxel Introduction SANO Our Pinxel model is specially designed to deliver RF energy directly to the epidermis or dermis skin layer. This stimulates and remodels collagen effectively by either RF microneedling mode (invasive) or RF matrix mode (non-invasive). It can be used for both epidermal and dermal applications in one platform, without changing the operating environment.

Single System Fractional RF and Bipolar RF Easy-touch Screen Negative Polar Foot Switch Cooling head Two Tips

Fractional RF Micro-Needle Treatment area : Middle & Lower Dermis Available to Treat both Epidermis & Dermi Regardless Of skin types Fractional RF Sub-lative Rejuvenation Treatment area : Epidermis & Superficial Dermis Minimal Downtime PINXEL Database Technology Lesser risk Of PIH (Post-inflammatory Hyper-pigmentation) Dual Fractional RF mode

Specification of Pinxel Specifications System Type Mono & Bipolar RF Bipolar RF Frequency 2MHz Total RF Treatment Level Up to Level 10 Dual Operation Mode Fractional RF Micro-needle Fractional RF Sub-lative Max Energy 50W Disposable Tip Micro-electrode needle Micro- electrode tip Depth of Needle 0.5-3 mm (Adjustable) Cooling head -10 Display 10.4 inch LCD Switch Foot Switch Dimension(mm) 280mm(W) x 505mm(L) x 1100mm(H) Weight 20kg Electrical Requirements AC/100-240 V, 50-60 Hz

RF versus Laser Radio Frequency Laser All skin types Easily penetrates target area Less side-effect risk Easily controlled depth Energy directly to target area with no energy loss Selective laser absorption Penetrations vary per absorption rate for water, hemoglobin, melanin etc Depth control difficult Energy delivery to target area varies depending on many parameterse

Advantage of RF fractional Fractional technology results in quick wound healing reaction from surrounding, undamaged tissue.

PINXEL Fractional RF Micro needle For invasive treatments. Effective, direct thermal stimulation to remodel collagen with less epidermis damage. Effective, direct thermal stimulation to remodel collagen with less epidermis damage. Micro Needle (Direct energy delivery) Radio Frequency (Thermal Damage ) Satisfactory Results

PINXEL Fractional RF Micro needle RF Gold coated electrode 20um 300um Micro Needle RF penetrates target area from epidermis to dermis without energy loss; stimulates and efficiently remodels disordered collagen. Step-motor driven mechanism enables precise, accurate penetration depth control. Needle Depth Precision needle depth penetration adjustment between 0.5mm and 3.0mm, by 0.1 mm increments.

PINXEL Fractional RF Micro needle Duration time & energy Pinxel creates various energy fields, as per application. Emissions 0.1 sec to 0.9 seconds; intensity level range 1 to 10. Power 1.6 (0.8 sec X Intensity 2) Power 1.6 (0.2 sec X Intensity 8) Long time and Low Intensity Short time and High Intensity

PINXEL Fractional RF Fractional RF delivers thermal energy to the treatment area more safely and effectively, allowing treatment regardless of skin type. The laser energy is mostly absorbed by melanin, especially in darker skin which contains a higher melanin content. Laser resurfacing can be damaging to the epidermal level, making dark skin laser treatment particularly risky. RF however avoids melanin targeting since it no longer depends on a light & laser energy to heat the skin, making Fractional skin rejuvenation a safe treatment method. Non-invasive Fractional RF provides significant lifting effects.

PINXEL Fractional RF Laser energy penetration is weakened by any absorption of water, hemoglobin, melanin, etc. but RF energy penetrates the target area without absorption. Energy pores on surface of skin are closely connected with period, so smaller pores equals a shorter recovery time.

Tips RF Needle Tip No burn or side effect risk. Better energy delivery results. Easily controlled depth penetration. Acne Scar, Large pore, Wrinkle, Skin tone, Skin Elasticity / Volume. Fractional RF Tip Less pain, shorter recovery time. No risk to sensitive skin. Deep heat for immediate effects. Skin texture, Large pore, Fine Wrinkle, Lifting, Skin Tightening. RF Needle Tip Fractional RF Tip

Specification of Pinxel Tips Micro Needle RF Matrix RF Energy source RF(Radio Frequency) Laser Type RF(Radio Frequency) RF Output Max. 30 W RF Output Max. 50 W RF Electrode Bipolar / Monopolar RF Electrode Bipolar Spot size Repetition Rate Penetration depth 12 x 12mm(25pin) 20 x 20mm(49pin) Spot size 12 x 12mm(64pin) 0.5-3.0sec. & manual 0.5 3.0mm Penetration depth Duration Time (Emission) 0.1 0.9sec Duration Time (Emission) 0.1 0.9sec

THANKS www.beautycliniclaser.com Address: 3rd floor, Building No.4, Maohuagongchang, Nancaizhen, Shunyi District, BeijingTel: 86-13930522511, 0086-53006037 Email: shelly@sanhebeauty.net