REVAMP2250 Instruction manual

Similar documents
REVAMP2600 Instruction manual

REVAMP2250 Instruction manual

REVAMP4120T Instruction manual

REVAMP4100 Instruction manual

PM7400MKII. Instruction manual

MA120 - MA240 Instruction manual

MANUAL. Champ - 4. Professional quad power amplifier

MANUAL. Champ - One. Audiophile Stereo Power Amplifier

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

PREZONE1 Instruction manual

MANUAL PA8250

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

MA30 - MA60 Instruction manual

User Manual. ia480x Power amplifier

AMIS250P 250w Power Amplifier. Operating Manual. AMIS250P, 250 Watt Power Amplifier

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

Professional Power Amplifier HORIZON SERIES USER MANUAL. Content

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

EPA104/254. User Manual.

Professional Power Amplifier

WX-1 & WX-3 OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier. WX-1 and WX-3.indd :23:16

EPA152/252/502. User Manual.

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide

Amplifier Series BASIC. Installation & Operations Manual

DIGITAL CROSSOVERS AND DSP PROCESSORS

MANUAL MA200

GUITAR POWER AMPLIFIER U S E R ' S M A N U A L

H A 6 6 CHANNEL STEREO HEADPHONE AMPLIFIER INSTALLATION AND OPERATION MANUAL

User Manual. MA 21 Two zone mixing amplifier

IMPORTANT SAFETY INSTRUCTIONS

M-300 Mono power amplifier User s guide

System Power Amplifier (SPA)

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

OWNER S MANUAL CPS 1 / CPS 2 CONTRACTOR PRECISION SERIES

DCM w Power Amplifier

TOA 900 SERIES POWER AMPLIFIER P-924A

USER MANUAL APG DYNAMIC PROCESSORS MATRIX ARRAY SYSTEMS 4000SP 6000SP 9000SP

PowerMatch PM8500 / 8500N TECHNICAL DATA SHEET. configurable power amplifier. Key Features. Product Overview. Applications

User Manual. MA 240 Mixing amplifier

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

FreeSpace ZA 250-LZ / 190-HZ zone amplifier TECHNICAL DATA SHEET. Key Features. Product Overview. Product Information.

Boulder W Class A Stereo Power Amplifier

American Audio. User Instructions. American Audio 4295 Charter Strret Los Angeles Ca Revised 5/01

A 4000 A Owner s Manual HPA HPA A4000 A5000 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2 CHANNEL 1 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2

E4-130, E4-250 power amplifier. user manual

A32. f u l l y b a l a n c e d p o w e r a m p l i f i e r. user guide

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

PROFESSIONAL SMPS STEREO AMPLIFIERS USER GUIDE

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

OWNER S MANUAL CPS 3 / CPS 4 CONTRACTOR PRECISION SERIES

CABINET POWERED MIXING CONSOLE

FEATURES: Affordable, reliable power perfect for DRM Series Passive Loudspeakers, installations, and production audio systems

2BSST POWER AMPLIFIER OWNER S MANUAL

TSA 4-700, TSA 1400, TSA 2200, TSA 4000, TSA 4-300, TSA power amplifier. user manual

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

AV30MX-2 Operation Manual

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

D3400 digital power amplifier. user manual

FreeSpace IZA 250-LZ / 190-HZ TECHNICAL DATA SHEET. integrated zone amplifier. Key Features. Product Overview. Product Information.

PLANNING YOUR SYSTEM

User's Manual PS 2/2A LTO R. Version 1.1 Septemper 2005 English

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

3.Avoid spilling liquids or allowing materials to enter the cabinet

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

PowerShare PS602 adaptable power amplifier

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

DigiMod 3000PFC DigiMod 3000PFCsu

************* OWNER'S MANUAL STAX1250/2 STAX1800/2 STAX2200/2 STAX1200/4 STAX1600/4 STAX2300/4 STAX2000/1D STAX4000/1D STAX5500/1D

KX120.2 / KX150.2 / KX200.2

User Manual. imix 63 Stereo mixing preamplifier

MANUAL MA247 MA247MR

E-400 power amplifier. user manual

The ART SLA-2 Studio Linear Amplifier

UA ª 35T II Utility Amplifier OPERATING INSTRUCTIONS

POWERED MIXER DIGITAL ECHO EFFECT ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO VOL REPEAT MPM CHANNEL POWERED MIXER OWNER S MANUAL

3400 Watt Stereo Power Amplifier

Studio MODEL:PA600X/PA800X/PA1000X/ PA1800X PA AMPLIFIER PRO. High Performance Professional Audio.

LFA4-840 / LFA / LFA LFA1-2000D / LFA1-4000D / LFA1-5500D LFA2-420 / LFA2-600 / LFA2-800 LFA / LFA / LFA / LFA2-2600

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

Stereo / Mono. Audio Power Amplifier - 60 W. Introduction. Applications

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

Integrated mixer amplifier PA-60/120/240

Primare A33.2 Amplifier User Guide

NE SERIES. ne Models ne800 ne1600 ne2400

DX 48 DX 24 DX 12 D X - S e r i e s

PROLUDE AMPLIFICATION D750. User s manual for the tube preamplifier version

15" 500W self-powered subwoofer

E-800 power amplifier. user manual

Cover for IPA 75/150T II

E-800 power amplifier. user manual

6/24/02 DigiMod 500 DigiMod 1000 DigiMod 1500 DigiMod 2000HV DigiMod 1000NPS. User Manual

AMPLIFIERS. Bi2200Tx Bi4200Fx. Bi1400Mx Bi2400Mx Bi3000Mx

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

AX6220Z/AX6240Z. Energy-Efficient, DSP-Powered and Ethernet/USB-Controlled 1000/900-Watt 70/100 V High-Impedance Power Amplifier.

AMC SERIES 30W/60W/120W/250W MIXER AMPLIFIERS INSTALLATION AND OPERATION MANUAL

8101 SPECIFICATION SHEET

Owner s Manual.

Transcription:

REVAMP2250 Instruction manual

REVAMP2250 Instruction manual 3 REVAMP2250 Manual

4 DIGITAL POWER AMPLIFIER Safety first! Caution! This professional device needs to be installed by qualified personnel only. Please check the carton box for any kind of damage on reception of the goods. In case of a damaged carton, please contact your dealer before opening the carton.!!!! Danger!!!! Exposure to high sound levels may cause a permanent hearing loss. Individuals vary considerably to sound pressure level induced hearing loss but nearly everyone will lose some hearing if exposed to high sound pressure levels for a sufficient amount of time. Therefore it is recommended that all persons exposed to equipment capable of producing high sound pressure levels, such as this amplifier, be protected by hearing protection while installing or operating this unit. Read all documentation before operating your equipment. Keep all documentation for future reference. Save the carton and packing material even if the equipment has arrived in good condition. Should you ever need to ship the unit, use only the original factory packing. Do not spill water or other liquids into or on the unit. Make sure power outlets conform to the power requirements listed on the back of the unit. Do not use the unit if the electrical power cord is frayed or broken. Always operate the unit with the AC ground wire connected to the electrical system ground.

REVAMP2250 Instruction manual 5 Set level controls on amplifiers all the way down during powerup to prevent speaker damage if there are high signal levels at the inputs. Do not connect the inputs / outputs of amplifiers or consoles to any other voltage source, such as a battery, mains source, or power supply, regardless of whether the amplifier or console is turned on or off. Power down & disconnect units from mains voltage before making connections. Do not use the unit near stoves, heat registers, radiators, or other heat producing devices. Do not operate equipment on a surface or in an environment which may distort the normal flow of air around the unit. If the unit is used in an extremely dusty or smoky environment, the unit should be periodically blown free of dust. Do not remove the cover. Removing the cover will expose you to potentially dangerous volt ages. Do not drive the inputs with a signal level higher than that required to drive equipment to full output. Do not run the output of any amplifier back into another input. In case of mal-function this device should be serviced by qualified service personnel only. This unit has NOT been designed for use in mobile applications, such as: mobile discobars, mobile PA systems, Live bands, audio rental systems, CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER-SERVICEABLE PARTS INSIDE SERVICING ONLY FOR QUALIFIED PERSONNEL

6 DIGITAL POWER AMPLIFIER Features 1 rack unit high High power Hypex class-d power amplifier modules Bridgeable 2 channel amplifier Dynamic output power: 2x350W @ 4Ω Sine wave power per channel: 2x250W @ 4Ω (500 msec) Dynamic bridged output power: 700W @ 8Ω Bridged Sine wave output power: 500 W @ 8Ω (500 msec) High thermal efficiency Highest possible damping factor Soft start switching power supply unit No cooling fan Low power consumption Integrated Analog Devices digital signal processor (DSP) with easy one button operation: simply push the button to select an operating mode, making this amplifier the ideal multi purpose tool for your applications LF filter for increased stability when using 100 volt transformers on the output, allowing you to use 100 volt speakers as top speakers combined with a standard low impedance subwoofer for example Integrated APC limiter/compressor Balanced euroblock inputs

REVAMP2250 Instruction manual 7 Unbalanced inputs on RCA with pass through Input level attenuators on all inputs 4-pole Speakon speaker output connectors Euroblock speaker output connectors Extended speaker and amp protection circuits: DC protect, over current protect, over temperature protect, input overload Individual channel mute buttons and versatile LED status indicators This unit has NOT been designed for use in mobile applications, such as: mobile discobars, mobile PA systems, live bands, audio rental systems, Removable rack-ears Note: the integrated APC limiter will automatically limit the incoming audio signal to avoid overloads. This feature can not be defeated and acts as a lifesaver for your valuable speakers.

8 DIGITAL POWER AMPLIFIER Connections 1 3 4 5 6 8 9 2 7 11 10 12 13 1. Channel 2 overload led: when this led lights up, you are overloading the input. Lower the input signal immediately to prevent the amplifier from shutting down. 2. Channel 1 overload led: when this led lights up, you are overloading the input. Lower the input signal immediately to prevent the amplifier from shutting down. 3. Channel 2 input gain setting. Adjust the input gain to the output level of your source. Make sure to avoid the clip led lighting up at the strongest input peak level. 4. Channel 1 input gain setting. Adjust the input gain to the output level of your source. Make sure to avoid the clip led lighting up at the strongest input peak level. 5. DSP selector switch with led indicators: push the button to scroll between the various pre-programmed DSP settings. There are 6 possible DSP settings and 2 available combinations. The settings will be memorized and recalled when the unit is

REVAMP2250 Instruction manual 9 powered up. Full details of the available settings can be found below. 6. Channel 2 speaker output on 2 pole euroblock connector. 7. Channel 1 speaker output on 2 pole euroblock connector. 8. Channel 2 speaker output on speakon connector. Pin 1+ = speaker 2 +, pin 1- = speaker 2 -. 9. Channel 1 and 2 stereo speaker output on speakon connector. Pin 1+ = speaker 1 +, pin 1- = speaker 1 -; Pin 2+ = speaker 2+, pin 2- = speaker 2-. In bridge mode, pin 1 + = speaker +, pin 2+ = speaker-. 10. Channel 2 unbalanced input and link cinch connector: connect the line level input signal for channel 2 here. Line level is 0 dbv. Input and link connector are internally connected 1 on 1. 11. Channel 1 unbalanced input and link cinch connector: connect the line level input signal for channel 1 here. Line level is 0 dbv. Input and link connector are internally connected 1 on 1. This connector is also used in bridge mode or when DSP mode CH1 SUB CH2 TOP is selected. 12. Channel 2 balanced input on 3 pole euroblock connector. 13. Channel 1 balanced input on 3 pole euroblock connector. This connector is used in bridge mode or when DSP mode CH1 SUB CH2 TOP is selected. 14. Mains inlet: connect the mains power cord here.

10 DIGITAL POWER AMPLIFIER Operation 1 1 2 3 4 6 5 1. Removable rack ears for 19 rack mounting. 2. Power switch: after switching on the power, the power led will light up after approx 1 second. The limit-muted leds will light up for a few seconds to avoid excessive power on pop noise. 3. Power led 4. Channel 1 status led bar and mute switch: when the mute switch is pressed, the orange LIMIT MUTED led will light up. This led will also light up when the internal limiter is activated to avoid the amplifier from being overloaded by high input signals. The CLIP OVERLOAD led indicates that the power amplifier is clipping: reduce the input signal at once whenever this occurs!!! The green SIGNAL - -40dB led will light up when an input signal is present. The red INPUT OVERLOAD indicates that the input is being overloaded. Reduce the incoming signal at once!!! 5. Channel 2 status led bar and mute switch: when the mute

REVAMP2250 Instruction manual 11 switch is pressed, the orange LIMIT MUTED led will light up. This led will also light up when the internal limiter is activated to avoid the amplifier from being overloaded by high input signals. The CLIP OVERLOAD led indicates that the power amplifier is clipping: reduce the input signal at once whenever this occurs!!! The green SIGNAL - -40dB led will light up when an input signal is present. The red INPUT OVERLOAD indicates that the input is being overloaded. Reduce the incoming signal at once!!! 6. DSP setting led display: the leds show which of the DSP settings or combinations have been activated. DSP features and audio signal routing: There are 6 possible DSP settings and 2 available combinations. The settings will be memorized and recalled when the unit is powered up. CH1 SUB TOP CH2: frequencies below 100 Hz are sent to the sub channel (CH1). Frequencies above 100 Hz are sent to the top channel (CH2).The Filter slope (12 db/oct or second order Butterworth characteristic) and frequency (100Hz) are fixed. The Audio signal from input 1 is used. CH1 TRAFO LOAD: Use this mode when you want channel 1 of your amplifier to drive a transformer to drive 100V speaker systems. This mode applies a highpass filter to channel 1. Filter characteristics: 12 db/oct at 50 Hz. Butterworth characteristic. This setting increases amplifier stability when using a 100 volt transformer on output 1. CH2 TRAFO LOAD: Use this mode when you want channel 2

12 DIGITAL POWER AMPLIFIER of your amplifier to drive a transformer to drive 100V speaker systems. This mode applies a highpass filter to channel 2. Filter characteristics: 12 db/oct at 50 Hz. Butterworth characteristic. This setting increases amplifier stability when using a 100 volt transformer on output 1. CH1 BRIDGED CH2: both amps are used in bridge. Audio signal from input 1 is used. Combination CH1 SUB TOP CH2 with CH2 TRAFO LOAD: this combination allows a low impedance subwoofer to be used with 100 volt top speakers. Audio signal from input 1 is used. This setting increases amplifier stability when using a 100 volt transformer on output 2. CH1 TRAFO LOAD with CH2 TRAFO LOAD: a highpass filter is applied to channel 1 and 2 to ensure that low frequencies are filtered. Filter characteristics: 12 db/oct at 50 Hz. Butterworth characteristic. This setting increases amplifier stability when using 100 volt transformers on the outputs.

REVAMP2250 Instruction manual 13!!! IMPORTANT!!! This amplifier relies on convectional cooling only. In normal situations, overheating will not occur due to the class D amplifier topology. Since there are no cooling fans in the amplifier, make sure the convectional cooling system can work properly. The unit can be built in a 19 inch rack system, but it is forbidden to block the ventilation holes provided. Therefore, it is absolutely necessary to allow at least one free rack space or 44 mm above and beneath the amplifier. Make sure the ambient temperature is between 0 and 40 C. Operating the unit beyond its normal limits may cause overheating. Power amplifiers are hard workers, and their behaviour is similar to human beings. In extreme conditions, human beings are not able to perform efficiently. This also applies to amplifiers. It is generally a bad idea to mount multiple heat generating units such as amplifiers in the same rack. If necessary, use a forced ventilation system in your mounting rack. The mains fuse is located inside the unit. When the fuse is broken, replace it with a fuse of the same current and voltage rating: 5.0 AT/250V. For qualified personnel only! This unit has NOT been designed for use in mobile applications, such as: mobile discobars and DJ setups, mobile PA systems, live bands, audio rental systems, Use it in fixed installations only.

14 DIGITAL POWER AMPLIFIER 110 VAC operation: it is possible to operate the unit at 110 (115) VAC. Therefore, open the unit and set a wire jumper on the connector for 110 VAC operation.

REVAMP2250 Instruction manual 15 Technical specifications Dynamic output power 2 x 350 W @ 4 Ω Sine wave power per channel Dynamic output power bridged Sine wave power bridged Minimum output load impedance CH1 and CH2 Minimum output load impedance bridge mode Input connections Input sensitivity Input impedance S/N ratio THD ch. 1/2 Frequency response Built-in DSP Protection circuits Channel separation Damping factor APC sytem Power amp topology Power supply 250 W @ 4 Ω (500 msec) 700 W @ 8 Ω 500 W @ 8 Ω 4 Ω 8 Ω 2 x balanced euroblock, 4 x unbalanced cinch with pass through 0 dbv / 1 V 22 kω >90 db A weighted <0.1% @ 100 W / 4Ω / 1kHz A weighted 10 24 khz + 0 / - 3dB yes over current, over temperature, DC offset, AC and DC over- and undervoltage >74 db @ 1 khz > 50 all channels internal compressor and clip limiter class D SMPS

16 DIGITAL POWER AMPLIFIER Cooling Max power consumption convectional 600 W Operating temperature range 0 to 40 C Mains operating voltage Dimensions Net weight 3.1 kg Gross weight 230 VAC / 50-60 Hz (115VAC with internal jumper) 483 x 44 x 235 mm ( including rack ears) 4.9 kg

REVAMP2250 Instruction manual 17

18 DIGITAL POWER AMPLIFIER

developed by Audioprof nv Industriepark Brechtsebaan 8 bus 1 2900 Schoten - Belgium Company names, product names and trademarks are property of their respective owners. Apart-Audio specifications are subject to change without notice.