Nine LEDs provide feedback of transmitter operation. Induction selected One Red LED Frequency/Mode selection Four Green LEDs

Similar documents
Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

RD4000 Locating system

vscan Data Sheet V1.0

cable and pipe locators RD Utility cable and pipe locator

PIPELINE DEFECT MAPPER

Loc-5Tx Data Sheet V2.1

Utility cable and pipe locator

UAT-600 Series. amprobe.com

Universal precision cable and pipe locator

A higher performance product designed for safer excavating.

UTILITY LOCATING EQUIPMENT

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Precision Pipeline Locator System User Guide. Rev

Utility cable and pipe locator

The new CXL2 and DXL2 Cable Avoidance Tools and SGA2 and SGV2 Signal Generators from C.Scope have been designed to set a new benchmark in excavating

Dynatel 2250E/2273E Advanced Cable and Fault Locator

High Performance, Application Specific Cable Avoidance

pipeline integrity PCM + Pipeline Current Mapper

Obsolete Document. Dynatel

Tender NO. PGVCL/PROC/Cable & Pipeline Locator/832

Universal precision cable and pipe locator

RD8000. Radiodetection s universal precision cable, pipe and RF marker locator. Operation manual 90/RD8KM-OPMAN-ENG/03

RD7000+ Radiodetection s universal precision cable, pipe and RF marker locator. Operation manual 90/RD7K+M-OPMAN-ENG/03

AT-5000 Professional Underground Cable / Pipe Locator System

Cable avoidance reaches a new level

cable and pipe locators RD Utility cable and pipe locator

Locator Accessories INSTRUCTION MANUAL

RD7100. Precision utility Cable & Pipe Locator

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

RD7100 Locator Specification

Pipeline Current Mapper

cable and pipe locators RD8000 Universal precision cable and pipe locator

Leica Digisystem Safe and fast location of underground services

RD8100. Precision Multifunction Cable & Pipe Locator

USERS MANUAL TR-710.

RD5100 Series. Precision water industry pipe and cable locator kits

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

RD7000 Radiodetection s general utility cable and pipe locator.

SeekTech SR-60 SeekTech SR-20 NaviTrack Scout

RD Utility Precision Locator Range Launch pack

vlocpro NEW Features & Accessories NEW Standard Features available now! New Displays

Instruction Manual. Model XTpc-33 khz Pipe & Cable Locator

INDEX. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Using with LED System...

Cable avoidance reaches a new level

EDENBROS, LLC. RD Radiodetection s utility specific cable and pipe locators. Operation Manual l Issue 1 l January 2011

Easy to use, single frequency. pipe and cable locator

Advanced Test Equipment Rentals ATEC (2832) Universal precision cable and pipe locator

INDEX PREFACE... 1 CAUTIONS... 2 OPERATION ON SITE(9) STANDARD INSTRUMENT... 3 OPTIONAL ACCESSORIES... 4 OPERATION OF TRANSMITTER(3)...

PR-216. High Performance Personal Receiver PR-216 OPERATOR S MANUAL

RadioDetection RD7000DL+ TX-5 Specs Provided by Utility cable and pipe locator

MIT415 Insulation tester

F I S H E R R E S E A R C H L A B O R A T O R Y

TW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y

RD8100 Locator Specification

vloc Series 2 Smaller and lighter Over four times battery life Define, set and lock available features Customizable startup screen and much more...

Principles of Cable & Pipe Location

PRECISION PIPE AND CABLE LOCATION. Instruction Manual Function Checker

Version 1.0 English. EziSYSTEM User Manual

Utility cable and pipe locator

Pipe & cable locator for avoidance & tracing applications. The ideal choice for the novice through to the skilled technician

Operators Manual For Spectrum Analyser SA97

Instruction Manual CXL Locator DXL Locator MXL Locator SGA Signal Generator SGV Signal Generator MXT Transmitter

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

When reporting any problems to your Radiodetection Dealer or Supplier it is important to quote the unit serial number and the purchase date.

Loki Pipe & Cable Locators

RD UTILITY CABLE, PIPE AND RF MARKER LOCATOR range

General Warnings Non-Metallic Pipe Tracing Features Depth Measurement Locator Operating Modes Signal Current Measurement Function Checks

PCMx. Pipeline Current Mapper system. User Guide 90/UG105INT/01

Locate Plastic. Pipe &Conduit. 3M Electrical Markets Division

WE-525T Antenna Analyzer Manual and Specification

MIT480/2 Insulation testers

Locate Plastic. Pipe &Conduit. 3M Infrastructure Protection Division

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

Leica Digisystem i-series Safe and fast location of underground utilities

QLD/NT NSW WA

cable avoidance tools C.A.T4 and Genny4 Detect more, faster, smarter, safer

UltraTEV Locator. Portable PD (Partial Discharge) investigation system. benefits. features. FACT: 85% of disruptive substation failures are PD-related

Table of Contents - 2 -

WARNING! When using the transmitter, switch off the unit and disconnect cables before removing the battery pack.

MIT400 CAT IV Industrial Insulation Testers

Battery Analyzers BA6010 Series

HAWK5000 Operators Manual

SL7000 Series. Universal Input Data Loggers

MIT400 CAT IV Industrial Insulation Testers

Leica Digicat i-series Safe and fast location of underground services

TW-82 TW-82 ACCESSORIES. Operating Manual Revision Level 1 DIGITAL LINE TRACER

TW-82. Operating Manual DIGITAL LINE TRACER. Revision Level 1

DynatelTM Cable Locator. Operators Manual. October Revision A

GFL-1000 User Manual Ground Fault Locator

Leica DIGISYSTEM TM Safe and fast location of underground services

TW-82 DIGITAL LINE TRACER. Operating Manual

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Digital Function Generator

Electronic Pipeline Technology

TG 500 DRAHTLOSSYSTEM TG 500 PROFESSIONAL WIRELESS SYSTEM GREAT PERFORMER. CAT_TG500_17-07_EN_210x280_RZ.indd :17

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

CIPS, DCVG & GPCM Pipeline Surveyor. Corrosion Control Equipment

Transcription:

RD4000T and TF Transmitters Technical Specification Draft 0/07/0 Description: RD4000 transmitter Part No: 10/T * (*=version) 10/TF * (*=version) Physical: Construction High Impact thermoplastic injection moulded case sealed to IP55 (excludes all battery tray variants) Ruggedness Withstands one metre drop onto concrete (BS EN 60068-) Dimensions Weight Approximately 180mm/7.1 (D) x 50mm/1.78 (W) x 0mm/9 (H) Approximately 4.kg/9.6Ib Available Operating Modes: Locate mode by Induction Locate Mode by Direct Connection FaultFind Mode by Direct Connection (TF only) Available Frequencies (±Hz) 1 Induction Frequency from the following: 8.19kHz,.768kHz, 65.56kHz, 8.000kHz or 00.000kHz factory configurable Up to Direct Connection Frequencies from RD standard range 440Hz 00kHz factory configurable FaultFind Output (RD4000TF Only) FaultFind frequency 8.19kHz/8Hz composite signal compatible with existing Radiodetection fault finding equipment FaultFind Voltage 10V at 8mA maximum. Audio Indication Visual Indication Transmitter On Connection Quality 1 second tone at switch on Sliding Tone from 40-400Hz lower tone equals more current on line (i.e. better connection) Low Battery Connection Tone pulses off 1 second in 5 Alarm Condition second warning tone Nine LEDs provide feedback of transmitter operation Output Level indicator Four Red LEDs Induction selected One Red LED Frequency/Mode selection Four Green LEDs All nine LEDs illuminate for seconds at switch on as a lamp check function Output Protection Output protected from inadvertent connection to 40V AC RMS.

Signal Output Continuous sinusoidal output waveform of selected frequency or FaultFind composite waveform if selected. Output pulses off 1 second in 5 (synchronised to connection tone) to indicate low battery conditions in normal modes of operation. To enable continued locating, FaultFind output does not pulse with low batteries Performance Connection Performance Output Level Open Circuit Voltage Limiting Current Maximum Power 1 0V RMS 5mA 0.15W 0V RMS 10mA 0.0W 0V RMS 0mA 0.90W 4 0V RMS 100mA*.00W** * Limiting current reduced to 60mA for frequencies less than 1kHz ** At 45kHz and above the output power is limited to 1W to comply with current legislation Induction Performance Output adjustable in four steps: 5%, 50% 75% and 100% At 45kHz and above the output power is limited to 1W to comply with current legislation Batteries 1 off LR0 (D) Alkaline 1.5V cells >8 hours continuous life at maximum output power (W) at 0ºC External 1V input socket for external power supply Optional rechargeable pack External Connectors Standard accessories Optional accessories RS Accessory outlet Direct connection lead External 1 volt supply lead Earth (ground) stake and 4 clamps Carry bag Earth extension lead Live plug connector Live cable connector Temperature Range Operating temperature: -0ºC to +50ºC Storage temperature: -40ºC to +70ºC Quality Control Approvals BS5750/ISO 9001/EN9001. Complies with European R&TTE Directive 1999/5/EC Complies with FCC Rules Part 15 Warranty 1 months. Radiodetection Ltd Western Drive Bristol BS14 OAZ, UK Tel: +44 (0) 117 976 7776 Fax: +44 (0) 117 976 7775 email:sales.uk@radiodetection.com http://www.radiodetection.com Radiodetection products are under continuous development and are subject to change without notice TS091EN00 All Rights Reserved 6 June 00

RD4000 T10 Transmitter Technical Specification Draft 0/07/0 Description Part No: RD4000 T10 Transmitter 11/T10 * (*=version) Physical Construction High Impact thermoplastic injection moulded case sealed to IP55 (excludes all battery tray variants) Ruggedness Withstands one metre drop onto concrete (BS EN 60068-) Dimensions Weight Approximately 180mm/7.1 (D) x 50mm/1.78 (W) x 0mm/9 (H) 4.kg/9.5Ib Operating Modes: Locate mode by Induction Locate Mode by Direct Connection Measure Mode (DVM/AVO operation) FaultFind Mode by Direct Connection (Optional) ACID-M Mode by Direct Connection (Optional) Pipeline Mode by Direct Connection Connected accessory is identified automatically and available modes/frequencies are set. Power restrictions for connected accessory are also set automatically. If no accessory is plugged in the unit defaults to induction mode. Available Frequencies (±Hz) Up to Induction Frequencies from 8.19kHz,.768kHz, and 65.56kHz, or two from 65.56kHz, 8.000kHz and 00.000kHz factory configurable Other Modes* Up to 16 direct connect frequencies CD: up to CD pairs may be used per accessory Frequency configuration is factory/dealer configured but can be user modified by use of the RD Web-based configuration tool. Induction frequencies must be specified at time of order as they are factory configured. *Note: Not all frequencies are available for all modes and accessories; some accessories will place restrictions upon the band of frequency available for use (e.g. signal clamps) FaultFind Output Audio Indication Indication Tones Visual Indication FaultFind Frequency 8.19kHz/8Hz composite signal compatible with existing Radiodetection fault finding equipment other FaultFind locate frequencies may be available at a later date. FaultFind Voltage 10VRMS at 8mA maximum. Volume Adjustable in four levels: Mute, low, med, high via user interface menu. Connection Quality Sliding Tone from 40-400Hz. A lower tone equals more current on line (i.e. better connection) Low Battery Connection Quality Tone pulses off 1 second in 5 and alert tone sounded of 6 rapid Error Condition Invalid Selection beeps Warning tone 1 short 00Hz beep Live-Cable Warning Alternating Warning Tone sounded whilst cable energised Output Protection Custom transflective LCD with automatic backlight. LCD displays the following information: Line current/voltage/resistance Operating mode and frequency Demand Level Battery/External Power status Audio volume setting Connection graphic to show how signal applied to target line Warnings for SELV limited output and live cable Output protected from inadvertent connection to 40V AC RMS via user resettable trip. LCD display gives user feedback that trip has operated. In FF mode the trip will not operate but the unit is still protected against inadvertent connection to 40 V AC.

Signal Output Continuous sinusoidal output waveform of selected frequency or composite waveform if selected. Output pulses off 1 second in 5 (synchronised to connection tone) to indicate low battery conditions Connection Performance Output Level Open Circuit Voltage* Limiting Current Maximum Power** 1 0V/50V RMS 10mA 0.50W 0V/50V RMS 0mA 1.50W 0V/50V RMS 60mA.00W 4 0V/50V RMS 100mA 5.00W 5 0V/50V RMS 00mA 10.00W 6 0V/50V RMS 400mA 10.00W 7 0V/50V RMS 700mA 10.00W 8 0V/50V RMS 1A 10.00W *Voltage can be increased from default 0V to 50V by menu selection. Voltage defaults to back to 0V each time unit is turned on. **Output power maximum 10W, display shows HI POWER when output power greater than 5W. This allows user to maximise battery life if 10W maximum output power is not required. At 45kHz and above the output power is limited to 1W to comply with current legislation. Induction Performance Output adjustable in four steps: 5%, 50% 75% and 100% At 45kHz and above the output power is limited to 1W to comply with current legislation Batteries 1 off LR0 (D) Alkaline 1.5V cells Optional High Capacity Rechargeable battery pack Battery Life Power output 10W 5W 1W Battery life (alkaline cells at 0 0 C and continuous use) > 4 hours >15 hours > 4 hours Battery trays have 1V input socket for external power supply Rechargeable battery pack has 1V input socket to recharge battery pack and simultaneously operate transmitter (if required) External Connectors Accessories Standard accessories Optional accessories RS Accessory outlet Accessories are automatically identified by the RD4000T10 when connected. The transmitter automatically selects mode and power/frequency limits based upon accessory fitted, and updates connection graphic on LCD display. Direct connection lead External 1 volt supply lead Earth (ground) stake Carry bag Earth extension lead and 4 clamps Live plug connector CD clamps Live cable connector Temperature Range Operating temperature: -0ºC to +50ºC Storage temperature: -40ºC to +70ºC Quality Control Approvals Warranty BS5750/ISO 9001/EN9001. Complies with European R&TTE Directive 1999/5/EC Complies with FCC Rules Part 15 1 months. Radiodetection Ltd Western Drive Bristol BS14 OAZ, UK Tel: +44 (0) 117 976 7776 Fax: +44 (0) 117 976 7775 email:sales.uk@radiodetection.com http://www.radiodetection.com Radiodetection products are under continuous development and are subject to change without notice TS09EN00 All Rights Reserved 6 June 00

RD4000RX Technical Specification Draft 0/07/0 Description: RD4000 Precision Locator Part No: 11/4KRx * (*= version) 11/4KMRx * (*= EMS version) Physical: Construction High impact thermoplastic, weatherproof to NEMA R and IP54 Ruggedness Withstands one metre drop onto concrete (BS EN 60068-) Dimensions Weight Approximately 690mm/7 x 80mm/11 x 1 mm/4.8 Standard version:.8 kg/6lb EMS version:. kg/7lb Power Radio Active frequencies Active frequencies CD Lf CPS Mode Frequency Bandwidth / Hz Sensitivity* @ 1 m Fault-Find (via optional external A-frame accessory) 40 Hz 700 Hz 14 khz 6 khz 8 khz 100 khz 100 khz 00 khz up to 104 Hz up to 048 Hz 100 Hz or 10 Hz 8 Hz and 8.19 khz 500 10,000 10,0 or 40 10, 0, or 40 10, 0 or 40 10, 0 or 40 10, 0 or 40 10 or 0 10 7.5 ma 0 µa 5 µa 50 µa 50 µa 50 µa 10mA µv @ 1M? 100 µa Locating Depth Guide (meters/yards) Good Conditions 5 5 5 -- Poor Conditions 1 -- Operating Modes: * Sensitivity specified for Peak mode Locate Accuracy: 5% of depth (depending on depth see below) Current Accuracy: 5% of actual current (depending on depth see below) Depth Accuracy 5% of depth on undistorted signal with no adjacent signals Depth Range Line up to m @ 5% depth accuracy, 5% current accuracy up to 5m @ 10% depth accuracy, 10% current accuracy Sonde up to 8m Visual Indication: Audio Indication: Search Antennas: Antenna Configurations: Liquid crystal display indicating the following: Signal Strength % Line Depth Sonde Depth Line signal current Gain Level Operating Mode Line/sonde mode Peak/Null/Single mode Left/Right direction arrows Battery Status Speaker Volume CD direction arrows Accessory connected Audio signal output through waterproof speaker or optional headphones. x dual wound horizontal and 1 vertical. Single horizontal for Wide response operation Dual horizontal for Peak operation Horizontal and vertical for Null operation

Gain Control: Batteries: Battery life Rotary touch gain paddle 4 x Alkaline size D (IEC: LR0) Optional rechargeable battery pack with four NiMH rechargeable batteries RX: >16 hours @0 0 C (non-ems modes) MRx: > 8 hours @0 0 C (EMS mode) Temperature Range: Operating temperature: -0ºC to +50ºC Storage temperature: -40ºC to +70ºC External Connectors RS connector (web-enabling/data logging) Accessory socket Headphone socket Accessories Accessories are automatically identified by the RD4000 receiver when connected. The receiver automatically selects operating mode(s) as appropriate to the accessory. Standard accessories Optional accessories RS lead Carry bag Sondes and 4 clamps Stethoscopes (CD and standard) CD clamps Headphones (summer and winter) Submersible antenna Rechargeable battery pack (complete with external 1 volt charging lead) A-frame Data logger Receiver Options: Electronic Marker-Ball Detection: (RD4000MRx) Marker Types Operation : Detection of any 1 of 6 marker types buried to a depth of 1.4m, Detection of large deep markers to a dept h of m, Bar-graph and variable pitch tone to indicate signal strength Manual EMS Gain Control High / Low Dedicated Marker Detection Dual Mode Operation -Narrow Band Cable Location (Null Mode only) combined with Marker Ball Detection Application Colour Frequency Power Red 169.8 khz Water Blue 145.7k Hz Sanitary Green 1.5 khz Telephone Orange 101.4 khz Gas Yellow 8.0 khz Cable TV Orange/Black 77.0 khz Compatibility Recommended for use with RadiodetectionT, TF, T10, and PTX- transmitters, and LMS. Also backwards compatible with obsolete Radiodetection transmitters. Quality Control Approvals Warranty BS5750/ISO 9001/EN9001. Complies with European R&TTE Directive 1999/5/EC Complies with FCC Rules Part 15 1 months. Radiodetection Ltd Western Drive Bristol BS14 OAZ, UK Tel: +44 (0) 117 976 7776 Fax: +44 (0) 117 976 7775 email:sales.uk@radiodetection.com http://www.radiodetection.com Radiodetection products are under continuous development and are subject to change without notice TS095EN00 All Rights Reserved 6 June 00