Simulation and Implementation of DVR for Voltage Sag Compensation

Similar documents
HARDWARE IMPLEMENTATION OF SINGLE PHASE DYNAMIC VOLTAGE RESTORER IN MITIGATING VOLTAGE SAG & SWELL

ISSN Vol.07,Issue.21, December-2015, Pages:

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Design Requirements for a Dynamic Series Compensator for Voltage Sags Mitigation in Low Voltage Distribution System

Compensation of Different Types of Voltage Sags in Low Voltage Distribution System Using Dynamic Voltage Restorer

Analysis, Modeling and Simulation of Dynamic Voltage Restorer (DVR)for Compensation of Voltage for sag-swell Disturbances

Protection from Voltage Sags and Swells by Using FACTS Controller

Design Requirements for a Dynamic Voltage Restorer for Voltage Sags Mitigation in Low Voltage Distribution System

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Power Quality Improvement using Hysteresis Voltage Control of DVR

PERFORMANCE OF DVR UNDER VOLTAGE SAG AND SWELLS CONDITIONS FOR POWER QUALITY IMPROVEMENTS

A Power Control Scheme for UPQC for Power Quality Improvement

Performance of DVR under various Fault conditions in Electrical Distribution System

Power Quality Improvement Using DVR

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

A Versatile Control Scheme for UPQC for Power Quality Improvement using fuzzy controller

ISSN Vol.03,Issue.11, December-2015, Pages:

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Design and Development of DVR model Using Fuzzy Logic Controller for Voltage Sag Mitigation

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

SIMULATION VERIFICATION OF DYNAMIC VOLTAGE RESTORER USING HYSTERESIS BAND VOLTAGE CONTROL

Mitigating Voltage Sag Using Dynamic Voltage Restorer

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

Mitigation of voltage sags/swells unbalanced in low voltage distribution systems

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Design of Interline Dynamic Voltage Restorer for Voltage Sag Compensation

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Power Quality Improvement in Distribution System Using D-STATCOM

Reduce the Harmonics Distortion of Sensitive Load against the Induction Motor Drive Non-Linear Load

Design of Dynamic Voltage Restorer for three phase network as steady state device in the Distribution System

Sag/Swell Compensation and Displacement Factor Improvement using IDVR in Distribution Network

Simulation of Dynamic Voltage Restorer Using Matlab to Enhance Power Quality in Distribution System

DESIGN AND DEVELOPMENT OF SMES BASED DVR MODEL IN SIMULINK

Reduction of Voltage Imbalance in a Two Feeder Distribution System Using Iupqc

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

II. RESEARCH METHODOLOGY

FUZZY LOGIC CONTROL BASED DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT IN DISTRIBUTION SYSTEM

Mitigation of Power Quality Problems Using DVR in Distribution Network for Welding Load

Investigation of Dynamic Voltage Restorer for Compensation of Voltage Sag and Swell

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Design and Simulation of Dynamic Voltage Restorer (DVR) Using Sinusoidal Pulse Width Modulation (SPWM)

VOLTAGE SAG COMPENSATION USING UNIFIED POWER FLOWER CONTROLLER IN MV POWER SYSTEM USING FUZZY CONTROLLER

Voltage Quality Enhancement in an Isolated Power System through Series Compensator

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

MITIGATION OF VOLTAGE SAG IN A DFIG BASED WIND TURBINE USING DVR

SIMULATION OF D-STATCOM IN POWER SYSTEM

Modelling of Dynamic Voltage Restorer for Mitigation of Voltage Sag and Swell Using Phase Locked Loop

Mitigation of Fault in the Distribution System by using Flexible Distributed Static Compensator (FD-STATCOM)

DYNAMIC VOLTAGE RESTORER (DVR) FOR VOLTAGE SAG COMPENSATION WITH FUZZY LOGIC CONTROLLER. Chennai, Tamilnadu, India. Chennai, Tamilnadu, India.

Transformer-Less Dynamic Voltage Restorer for Voltage Sag Compensation using PI Controller

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3

Voltage Sag and Mitigation Using Dynamic Voltage Restorer (DVR) System

IMPROVEMENT OF VOLTAGE SAG MITIGATION USING DYNAMIC VOLTAGE RESTORER (DVR)

Voltage Sags in Distribution Systems with Induction Motor Loads Fed by Power Converters and Voltage Mitigation using DVR and D-STATCOM

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

Voltage Sag and Swell Identification Using FFT Analysis and Mitigation with DVR

Power Quality Improvement of Grid Connected Wind Energy System by Statcom for Balanced and Unbalanced Linear and Nonlinear Loads

ISSN: [Singh* et al., 6(6): June, 2017] Impact Factor: 4.116

Multi level DVR with Energy Storage System for Power Quality Improvement

Mitigation of Faults in the Distribution System by Distributed Static Compensator (DSTATCOM)

Power Quality Enhancement using Voltage Source Converter based DSTATCOM

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Dynamic Modeling and Simulation of Unified Power Quality Conditioner

International Journal of Advance Engineering and Research Development CONTROL OF REDUCED-RATING DYNAMIC VOLTAGE RESTORER

Application of Dynamic Voltage Restorer for Voltage Balancing with ASD Load Using DQO Transformation

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

Simulation of a Dynamic Voltage Restorer to Compensate Voltage Sag for Improving Power Quality

Mitigation of Voltage Sag and Swell Using Dynamic Voltage Restorer

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Multifunctional Dynamic Voltage Restorer Using Matrix Converter Resmi. S, Reshmi. V, Joffie Jacob Amal Jyothi College of Engineering, Kanjirappally

Enhancement of Power Quality based on Unified Power Quality Conditioner (UPQC) K.S.Srikanth, Shaik. Musthak Ahmed, Y.Srinivasa Rao

Study & Comparison of Various Topologies of Dynamic Voltage Restorer & Its type: a Review

Power Quality Improvement By Using DSTATCOM Controller

New Topology of a Three Phase Dynamic Voltage Restorer (DVR) for Voltage Swells Mitigation in Electrical Distribution System

Interline Power Quality Conditioner for Power Quality Improvement

Improvement of Dynamic Voltage Restorer (DVR) Using Proportional Integral (PI)Controller for Mitigation of Voltage Sag

Power Quality Compensation by using UPFC

ISSN: ; e-issn

Mitigation of Voltage Sag/Swell Using UPQC

Power Control Scheme of D-Statcom

Compensation of Unbalanced Sags/Swells by Single Phase Dynamic Voltage Restorer

DYNAMIC VOLTAGE RESTORER USING THREE PHASE AC-AC CONVERTER

A Review on Improvement of Power Quality using D-STATCOM

Improvement in Power Quality of Distribution System Using STATCOM

Enhancement of Power Quality Using Advanced Series Active Power Filters

Implementation of UPQC for Voltage Sag Mitigation

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

A DYNAMIC VOLTAGE RESTORER (DVR) BASED MITIGATION SCHEME FOR VOLTAGE SAG AND SWELL

Power Quality and the Need for Compensation

COMPARITIVE STUDY ON VOLTAGE SAG COMPENSATION UTILIZING PWM SWITCHED AUTOTRANSFORMER BY HVC

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

Comparative Study of Sag & Swell Mitigation by a Novel Multi Level DVR with Wavelets

Transcription:

Simulation and Implementation of DVR for Voltage Sag Compensation D. Murali Research Scholar in EEE Dept., Government College of Engineering, Salem-636 011, Tamilnadu, India. Dr. M. Rajaram Professor & HOD / EEE, Government College of Engineering, Tirunelveli 627 007, Tamilnadu, India. ABSTRACT Power quality is one of major concerns in the present era. It has become important, especially, with the introduction of sophisticated devices, whose performance is very sensitive to the quality of power supply. Power quality problem is an occurrence manifested as a nonstandard voltage, current or frequency that results in a failure or mis-operation of end user equipments. One of the major problems dealt here is the voltage sag. To solve this problem, custom power devices such as Distribution Static Compensator (D-STATCOM), Dynamic Voltage Restorer (DVR), and Unified Power Quality Conditioner (UPQC) are used. In this paper, DVR, which is the most efficient and effective modern custom power device used in power distribution networks, is employed because of its lower cost, smaller size, and fast dynamic response to the disturbance. This paper presents the simulation analysis of a DVR in MATLAB / SIMULINK environment and its hardware implementation for voltage sag compensation. The results showed clearly the performance of the DVR in mitigating voltage sags Keywords DVR, D-STATCOM, MATLAB / SIMULINK, Power Quality, UPQC, Voltage sag compensation. 1. INTRODUCTION With the rapid technology advancements in industrial control processes, electric utilities are experiencing more demanding requirements on the power quality from the large industrial power consumers. The power quality problems in industrial applications concern a wide range of disturbances such as voltage sags and swells, flicker, interruptions, and harmonic distortion. Preventing such phenomena is particularly important because of the increasing heavy automation in almost all the industrial processes. The use of sophisticated electrical and electronic equipments, such as computers, programmable logic controllers, variable speed drives and so forth, very often requires power supplies with very high quality since the failures due to such disturbances usually have a high impact on production costs [1]-[4]. The voltage sag as defined by IEEE standard 1159, IEEE recommended practice for monitoring electric power quality is: a decrease in RMS voltage or current at the power frequency for durations from 0.5 cycles to 1 min, reported as the remaining voltage. Typical values are between 0.1 and 0.9 per unit and typical fault clearing times range from three to thirty cycles depending on the fault current magnitude and the type of over current detection and interruption [5,6]. Voltage deviations, commonly in the form of voltage sags can cause severe process disruptions and result in substantial production loss. Several recent surveys attribute that 92% of the disturbances in electrical power distribution systems are due to voltage sags [7]. The loss resulted due to voltage sag problem for a customer at the load-end is huge. Dynamic voltage restorer (DVR) [8]-[14] and Distribution static compensator (D-STATCOM) provide active solution for voltage sag mitigation. These system-equipment interface devices are commonly known as custom power devices [3,15], in which DVR is a powerful one for short-duration voltage compensation. Unlike the D-STATCOM which connects to the load in parallel, the DVR is connected in series with the sensitive load or distribution feeder and is capable of injecting real and reactive power demanded by the load during voltage sag compensation. However, a DVR cannot provide compensation during full power interruptions. An LC filter is provided at the output of the DVR inverter to attenuate the harmonic contents appearing in injected voltage. The filter parameters are designed according to certain design aspects such as depth of the sag to be mitigated and load voltage. In this paper, the simulation of DVR in MATLAB / SIMULINK environment and its prototype hardware implementation model are analyzed for voltage sag mitigation in a power system. The results showed the effectiveness and efficiency of DVR in mitigating voltage sags in a low voltage distribution system. 2. DYNAMIC VOLTAGE RESTORER (DVR) Dynamic Voltage Restorer (DVR) is a recently proposed series connected solid state device that injects voltage into the system in order to regulate the load-side voltage. The DVR was first installed in 1966 [16]. It is normally installed in a distribution system between the supply and the critical load feeder [17]. Its primary function is to boost up the load-side voltage in the event of a disturbance in order to avoid any power disruption to that load [18,19]. There are various circuit topologies and control schemes that can be used to implement a DVR. In addition to voltage sags and swells compensation, a DVR can also perform other tasks such as: line voltage harmonics compensation, reduction of transients in voltage and fault current limitations. The general configuration of a DVR consists of an injection / booster transformer, a harmonic filter, a voltage source converter (VSC), DC charging circuit and a control and protection system as shown in Fig. 1. In most sag correction techniques, the DVR is required to inject active power into the distribution line during the period of compensation. Hence, the capacity of the energy storage unit 26

can become a limiting factor in the disturbance compensation process especially for sags of long duration. Fig. 1 Principle of DVR 3. POWER SYSTEM UNDER STUDY Consider the power system compensated by a DVR as shown in Fig. 2. The series voltage source inverter (VSI) can generate a sinusoidal voltage with required magnitude, frequency and phase angle. This converter injects a dynamically controlled voltage in series with the supply voltage through the injection transformer to correct the load voltage. Fig. 2 Schematic diagram of a power system compensated by DVR Fig. 3 Equivalent circuit of DVR A passive filter placed at the high voltage side of coupling transformer rejects the switching harmonic components from the injected voltage. The control scheme is used to maintain a balanced and constant load voltage at the nominal value under system disturbances. There are two resistive loads; load-1 and load-2 each of 1 kw rating. The equivalent circuit of the DVR is shown in Fig. 3. When the source voltage drops or increases, the DVR injects a series voltage V INJ through the injection transformer so that the desired load voltage magnitude V L can be maintained. The series injected voltage of the DVR can be written as: Where, V + INJ = VL VS (1) V L is the desired load voltage magnitude. V S is the source voltage during sags / swells condition. The load current I L is given by: PL ± jq = VL L I L (2) 4. SIMULATION RESULTS AND DISCUSSION The power system shown in Fig. 2 is simulated in MATLAB / SIMULINK environment [20] for the cases of (i). with an additional AC source, and (ii). with DVR. Initially, an additional AC source is connected in the place of DVR. During normal operating condition, there is normal flow of current through load- 1. At initial state, the load-2 is disconnected from the system during the time interval from 0 to 0.2 sec. and no sag problem occurs in the system. During this interval, there is no voltage drop across the transformer primary as shown in Fig. 4. The voltage drop occurs in the transformer primary during the time interval between 0.2 and 0.5 sec. because of the load-2 added to the supply line at 0.2 sec. Now the sag problem occurs during the interval from 0.2 to 0.5 sec. Then the required voltage is injected by the AC source from 0.5 sec. onwards thereby compensating the line voltage and hence the sag problem is eliminated as shown in Fig. 5. Next, the additional AC source is removed and the DVR is connected in the system. As seen from Fig. 6, the DVR is not injecting any voltage till 0.1 sec. as there is no sag problem due to the disconnection of load-2. Then the load-2 is added to the system at 0.1 sec. Now the DVR injects voltage from 0.1 sec. onwards to mitigate the voltage sag problem. Initially the DVR injects a very small amount of voltage till 0.02 sec. for compensating the line drop. The voltages across load-1 and load-2 are shown in Fig. 7 and Fig. 8. Thus the voltages across load-1 and load-2 are almost maintained at constant values by injecting the voltage from DVR. 27

Fig. 4 Variation of voltage (volts) across transformer primary wrt time (seconds) with an additional AC source Fig. 5 Variation of voltage (volts) across load-1 and load-2 wrt time (seconds) with an additional AC source Fig. 8 Variation of output voltage (volts) across load-2 wrt time (seconds) with DVR 5. HARDWARE IMPLEMENTATION OF DVR The block diagram for prototype laboratory model of DVR along with other components is shown in Fig. 9 and the hardware circuit is shown in Fig. 10. During normal condition, the normal voltage appears across the load. The comparator-2 senses whether the load is in normal state or not. If the system is in normal state, the LCD display indicates NORMAL STATE. The comparator-1 senses the load continuously. When an extra load is added, the voltage sag problem arises. At that time, the LCD display indicates VOLTAGE SAG OCCURRED. Then the Comparator-1 gives a signal to the microcontroller. The microcontroller gives the pulses to the relay circuit and DVR circuit. The relay circuit gets closed and the DVR injects voltage to the load. The voltage sag problem is thus eliminated. When the extra load is removed, the voltage comes to normal value, but DVR injects voltage to the load continuously. The comparator-3 senses load voltage and gives a signal to the microcontroller which trips the relay circuit and stops the pulses to the DVR. The LCD display then indicates LOAD REMOVED. Fig. 6 Variation of injecting voltage (volts) from DVR wrt time (seconds) Fig. 7 Variation of output voltage (volts) across load-1 wrt time (seconds) with DVR Fig. 9 Block diagram for hardware implementation of DVR 28

performance of the DVR in mitigating voltage sags. The DVR handled the situation without any difficulties and injected the appropriate voltage component to correct rapidly any changes in the supply voltage thereby keeping the load voltage balanced and constant at the nominal value. In this study, the DVR has shown the ability to compensate for voltage sags; this has been proved through simulation and hardware implementation. The efficiency and effectiveness on voltage sag compensation showed by the DVR makes it an interesting power quality device compared to other custom power devices. Fig. 10 Hardware circuit The algorithm for the hardware implementation of DVR is given below: Step 1: Start the program. Step 2: Initialize the Port C and Port B of microcontroller. Step 3: Initialize LCD connected to Port D. Step 4: Clear the LCD display. Step 5: Display the WELCOME. Step 6: Check whether voltage sag problem occurred or not Step 7: If yes, go to next Step, otherwise go to Step 11. Step 8: Microcontroller passes signals to Relay, Comparator and activates DVR Circuit Step 9: Repeat Step 3 and Step 4. Step 10: Display VOLTAGE SAG OCCURS and 6V ADDED Step 11: Check whether the voltage is in Normal condition or not. Step 12: If yes, go to next step, otherwise go to Step 14. Step 13: Repeat Step 3 & Step 4 and display NORMAL STATE. Step 14: Check whether the voltage is above the Normal level. Step 15: If yes, go to next Step, otherwise go to Step 6. Step 16: Repeat Step 3 & Step 4 and display LOAD REMOVED. 6. CONCLUSION In this paper, the simulation of a DVR using MATLAB / SIMULINK software and its prototype hardware implementation have been presented. The simulation results showed clearly the 7. REFERENCES [1] Norbert EDOMAH, 2009, Effects of Voltage Sags, Swell and other disturbances on Electrical Equipment and their Economic Implications, 20th International Conference on Electricity Distribution, Prague. [2] M.H.J. Bollen, 2000, Understanding Power Quality Problems Voltage Sags and Interruptions, Piscataway, New York: IEEE Press. [3] A. Ghosh, G. Ledwich, 2002, Power Quality Enhancement using Custom Power Devices, Kluwer Academic Publishers. [4] N.G. Hingorani, 1995, Introducing Custom Power, IEEE Spectrum, 32(6), pp. 41-48. [5] IEEE Recommended Practice for Monitoring Electric Power Quality, IEEE Std, 1159-1995, 1995. [6] IEEE Recommended Practice for Evaluating Electric Power System Compatibility with Electronic Process Equipment, IEEE Std. 1346-1998, 1998. [7] D.D. Sabin, 1996, An Assessment of Distribution System Power Quality, EPRI Final Report, TR-106294-V2, Palo Alto, CA. [8] E.K.K. Sng, S.S. Choi, D.M. Vilathgamuwa, 2004, Analysis of Series Compensation DC-link Voltage Controls of a Transformerless Self-charging Dynamic Voltage Restorer, IEEE Transactions on Power Delivery, 19(3), pp. 1511-1518. [9] H. Ezoji, A. Sheikholeslami, M. Tabasi, M.M. Saeednia, 2009, Simulation of Dynamic Voltage Restorer using Hysteresis Voltage Control, European Journal of Scientific Research, 27(1), pp. 152-166. [10] J.G. Nielsen, M. Newman, H. Nielsen, F. Blaabjerg, 2004, Control and Testing of a Dynamic Voltage Restorer (DVR) at Medium Voltage Level, IEEE Transactions on Power Electronics, 19(3), pp. 806-813. [11] N.H. Woodley, L. Morgan, A. Sundaram, 1999, Experience with an Inverter-based Dynamic Voltage Restorer, IEEE Transactions on Power Delivery, 14(3), pp. 1181-1186. [12] M. Jazayeri, H. Abdollahzadeh, 2009, A Novel DVR Control System Design for Compensating all types of Voltage Sags Based on Pre-Fault Method, European Journal of Scientific Research, 33(1),, pp.70-85. [13] A. Ghosh, G. Ledwich, 2002, Compensation of Distribution System Voltage using DVR, IEEE Transactions on Power Delivery, 17(4), pp. 1030-1036. 29

[14] M. Vilathgamuwa, A.A.D. Ranjith Pcrcra, S.S. Choi, 2002, Performance Improvement of Dynamic Voltage Restorer with Closad-loop Load Voltage and Current mode Control, IEEE Transactions on Power Electronics, 17(5), pp. 824-834. [15] O. Anaya-Lara, E. Acha, 2002, Modelling and Analysis of Custom Power Systems by PSCAD/EMTDC, IEEE Transactions on Power Delivery, 17(1), pp. 266-272. [16] B.H. Li, S.S. Choi, D.W. Vilathgamuwa, 2001, Design Considerations on the line-side filter used in the Dynamic Voltage Restorer, IEE Proc. Generat. Trans. Distribut., 148(1), pp. 1-7. [17] Rosh Omar, Nasrudin Abd Rahim, Marizan Sulaiman, 2010, New Control Technique Applied in Dynamic Voltage Restorer for Voltage Sag Mitigation, American Journal of Engineering and Applied Sciences, 3(1), pp. 858-864. [18] K. Chan, 1998, Technical and Performance Aspects of a Dynamic Voltage Restorer, Proceeding of the IEE Half Day Colloquium on Dynamic Voltage Restorers - Replacing Those Missing Cycles, IEEE Xplore Glasgow, UK, pp. 5/1-525. [19] R. Buxton, 1998, Protection from Voltage Dips with the Dynamic Voltage Restorer, Proceeding of the IEE Half Day Colloquium on Dynamic Voltage Restorers - Replacing Those Missing Cycles, IEEE Xplore Glasgow, UK, pp. 3/1-3/6. [20] P. Boonchiam, N. Mithulananthan, 2006, Understanding of Dynamic Voltage Restorers through MATLAB Simulation, Thammasat Int. J. Sc. Tech., 11(3), pp. 1-6. 30