SMART TOILET CONTROL

Similar documents
SMART TOILET CONTROL

FLUSH CONTROL Installation, Operation and Maintenance Instructions Part# STCBL

Multiple Program Process Temperature Controller. Installation Guide Maxitrol Company, All Rights Reserved

O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS

C-Bus 8 Channel Low Voltage Relay

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

Installation Instructions

Expandable Controller 3, 7, 11, 15 stations Installation and Programming Guide

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

TS-700/1000 INVERTER Instruction Manual

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

ENGLISH MICRO TERROR

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

ENGLISH TERROR BASS 500/1000

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DAZZLE ACCENT LIGHTING SYSTEM

ENGLISH THANK YOU! DARK TERROR. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

ENGLISH THANK YOU! OR15. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

LT3000 ULTRASONIC LEVEL TRANSMITTER

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

Alemite FCS Fluid Control System

Radio Control Installation and Operating Instructions System 4

USER'S MANUAL DMR-6700

SERIES 70. R SERVO PRO Version 3.0 OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

ENGLISH THANK YOU! TH100. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

Programmable Process Temperature Controller

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Your Global Flow Control Partner. Series 70 SERVO PRO Version 3.0 Operation and Maintenance Manual

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

OceanLED. Sport Series DockLight. Installation Manual. This installation manual covers the following products: OceanLED Marine Product Support

Features COMPACT HIGH POWER MONO SUBWOOFER AMPLIFIER. Quick Start Guide

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

CBCT TM CIRCUIT BREAKER COIL TESTER

OceanLED. Sport Series DockLight. Installation Manual. This installation manual covers the following products: OceanLED Marine Product Support

ENVIRONMENTAL. Operating Temperature: -40ºC to +130ºC. Wire Size. Code Accepted Max Wire Gauge Insulation AWG Solid or Stranded

Big Bang. B B O w n e r s M a n u a l. Power Amplifiers. SpeakerCraft BB2125 POWER ACTIVE PROTECTION L

POWER TRACE TM TASCO, INC.

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

CAUTION. RXM5010 Touchscreen Remote Installation and Operation Manual MODEL: RXM5010

AD-8100 & AD-8200 Servo Amplifiers

Blue Point Engineering

Sealed Interface Control: EC20300

Installation Instructions

PPS MFS series - Installation Guide. Power Protector Stabilizer V 3.8 1

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

2011 / Circuit Tracer

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

QL50 Luminescence Sensor

UNITY/I TM. Installation Manual. UT3K, UT4K, UT5K and UT8K. Single-Phase Uninterruptible Power Systems

INSTRUCTIONS PS2500 POWER SUPPLY

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

Variable Refrigerant Flow (VRF) System Simple Touch Remote Control SAFETY WARNING

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

Fulfill Retrofit and Integrated Melter Capacitive Level Sensor P/N , and

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

Technical Description. DCF77 Receiver-Module 4460

Dual Terror Owners Manual

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

THANK YOU! Crush Micro PiX. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Current Loop Interface Module M-2025C

200Amp AC Clamp Meter + NCV Model MA250

OPERATING MANUAL SESAM 800 MOBILE TAIL LIFT EN -D0

Installation of Fillmaster DuraBlue Melters. System on. Introduction. Instruction Sheet P/N B

Taurus CP-300 Single Pump

Alternating Current Power

NSPL-500. AIS/VHF antenna splitter. User Manual ENGLISH.

USER'S MANUAL DMR-4350

BC145 SIGNAL ISOLATOR BOARD

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

f i r e - p a r t s. c o m

INTELLIMETER REGISTER

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

Autoranging Multimeter Extech EX503

Tel: Fax:

IM /2016 REV08 INVERTEC V205, V270 & V405

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Dawson DDM190. Digital Multimeter User s Manual

- Wiring Brochure Universal Reset Module 423e

312, 316, 318. Clamp Meter. Users Manual

Active UTP Transceiver Hub Installation Guide

USER'S MANUAL Revision C December 2011 THERMOCOUPLE WELDER

0.01kV (0 to ±0.99 kv)

Poke-Home Thru-Wire: WTW

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

WATERFLUX 3000 Quick Start

FMG90 Series Electromagnetic Flow Meter

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

DPA-1.2. Instruction Manual. 2 Channel Amplifier with Auto A/B Selector DPA-1.2 DPA-1.2 POWER SERIAL # LINE INPUT SENSING SPEAKER B OUT

- Wiring Brochure Universal Reset Module 423

Installation Instructions Space Temperature Transmitter

INVERTEC V160-S, V160-T & V160-TP

Transcription:

WARNING: WARNING: SMART TOILET CONTROL Installation and Maintenance Instructions Part# STC THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION. Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this product. Equipment damage, injury to personnel or death could result from improper installation. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment, injury or death to personnel that may result from improper installation or operation of this product. HAZARD OF SHOCK OR FIRE Always use recommended fuse, circuit breaker and wire size. Motors used with this product are Ignition Protected. They are not however, explosionproof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering. DO NOT run continuously for more than 30 seconds. Description: Smart Toilet Control (STC) is a controller for flushing toilet to optimize water use without compromising the quality of flush. Control consists of a controller, panel and 7 of cable. STC is designed to automatically start a flushing cycle if normal or water saver buttons are pressed. Panel Control box 1 Water only button brings inlet water to the bowl when pressed and empty only button evacuates the bowl. Both water only and empty button have a time limit of eight seconds. Flush timing of initial fill, discharge and final fill are fully programmable from panel. If wired, panel also shows holding tank full status. When holding tank full LED is lit, normal and water saver button are disabled. Water only and empty button continue to function. Control is reverse polarity protected. In case of reverse polarity motors and solenoid will activate as soon as power is connected. After reverse polarity is corrected (within 10 minutes), unit will work as normal.

OPERATION Multifunction Smart Toilet Control: 1. Press Empty Only: to evacuate the bowl. Discharge pump runs as long as this button is held with an eight second limit. If holding tank full LED is on this button still works. 2. Press Water Only: to add water in the bowl. Inlet water solenoid/pump runs as long as button is pressed with an eight second limit. After limit is reached Water Only button is disabled to prevent overflow of the bowl. To enable again, Empty Only button must be pressed. If holding tank full LED is on this button still works. 3. Press Normal: once and timed flushing cycle starts. If holding tank full LED is on this button is disabled. There are three cycles of inlet and discharge. First cycle removes most of the waste. Second cycle removes remaining waste if any left after first cycle, Third cycle clears all discharge housing and lines with clean water. Last fill is to retain water in the bowl for next use. This button is disabled if holding tank full LED is on. NOTE: Flush control is set at factory to work in most installations and no additional programming is needed. Use following instructions to re-program if adjustment on water levels and timings are needed. Programming timing for NORMAL flush cycle: Normal cycle has initial fill time (T1), Discharge pump time (T2), and water retention fill time (T3). All three times (T1,T2 and T3) are programmable. Factory setting : T1= 3sec, T2= 3sec, T3= 2 sec, To change any of the above settings re-programming is needed Step 1 Placing the unit in program mode: Hold the WATER ONLY & EMPTY buttons down together for three seconds. The Holding Tank Full LED will give three quick flashes indicating you have entered program mode - release both buttons. Setting T1 initial fill time: Programming of Toilet Flush Control After placing the unit in program mode (Step 1 2 4. Press Water saver: a water saver cycle starts. If holding tank full LED is on this button does not work. This cycle has only one cycle of inlet and discharge to clear liquid waste. Last fill is to retain water in the bowl for next use. This button is disabled if holding tank full LED is on. NOTE: Holding tank full light will only illuminate if the tank sensor has been added to the control. TOILET FLUSH CONTROL WATER SAVER WATER ONLY HOLDING TANK FULL above) push the Normal Flush button the number of times required for the Water Valve/ Inlet Pump time (one push = 2 sec s, two = 2 sec s., three= 3 sec s etc.) the Tank LED will flash once indicating a valid key push. Note: If the button is pushed 9 times or more it will limit at 8 secs. Once this is done, push the EMPTY button to store this value (the unit will flash three times indicating the time has been set and you have left program mode). Setting T2 Discharge Pump Time: NORMAL FLUSH EMPTY ONLY RARITAN After placing the unit in program mode (Step 1 above) push the EMPTY button the number of times required for the Discharge Pump time (one push = 2 seconds, two= 2 secs, three =3 secs etc.) the Tank LED will flash once indicating a valid key push. Note: If the button is pushed 9 times it will limits to 8 seconds. Once this is done push the NOR- MAL button to store this value (the unit will flash three times indicating the time has been set and you have left program mode).

Setting T3 Water retention fill Time: After placing the unit in program mode (Step 1 above) push the WATER ONLY button the number of times required for the Water Valve/Inlet Pump time (one push = ZERO sec s, two = 2 secs. three = 3 sec s., etc.) the Tank LED will flash once indicating a valid limit to 8 seconds. Once this is done push the NORMAL button to store this value (the unit will flash three times indicating the time has been set and you have left program mode). Programming the WATER ONLY Disable Features: 1. Hold the WATER ONLY & EMPTY buttons down together for three seconds. The holding tank full LED will give THREE flashes indicating you have entered program mode. 2. Push the WATER SAVER button. The WA- TER ONLY and EMPTY buttons now can be disabled or enabled: 3. Pushing the WATER ONLY button will disable both WATER ONLY and EMPTY buttons. The holding tank full LED will give THREE flashes indicating you have left program mode. Repeat steps 1 to 3 to re-enable these buttons. Programming the WATER ONLY button to only work after Empty button is pushed 1. Repeat step 1 & 2 above 2. Pushing the EMPTY ONLY button will enable this feature. The holding tank full LED will give THREE flashes indicating you have left program mode. Repeat 1 &2 above to disable this feature. Extending pause before water retention: Some installations require longer pause between discharge pump and final retention water fill to avoid siphoning: 1. Hold the WATER ONLY & EMPTY buttons down together for three seconds. The holding tank full LED will give THREE flashes indicating you have entered program mode. 2. Push the WATER SAVER button. This will place control in disable/enable mode 3. Pushing the WATER SAVER button again. The holding tank full LED will give THREE flashes indicating you have left program mode. Repeat steps 1 to 3 to shorten the pause. OPERATION Mounting control Panel: Smart Toilet Control panel: 1. Cut out a hole per Fig. 1, mark mounting holes using wall plate as guide. 2. Route wire to the toilet and control. 3. Secure control using mounting screws Smart Toilet Control Box; 1. Locate box near toilet in a dry and accessible area 2. Using two screws fasten the control to wall with connectors at the bottom. 3. Using one of the wiring diagram route all wires. Install the Warning Label (L322) where it can be easily seen. Fig. 1 CUT OUT Smart Flush Control 3

OPERATION For most installation factory settings will work without making any changes to timing. To make changes to timing or after installation to optimize the flushing follow guidelines below Observation or Issue Action Water does not empty all the way in the first cycle Water empties, but discharge pump runs more than a second after all water is gone in first cycle Solids and toilet paper remain in the bowl after first cycle Water level in too high after initial fill cycle There is no water or little water left in the bowl Water siphons out after 10 or 15 minutes from the bowl Increase discharge timing (T2) Decrease discharge time (T2) Increase initial fill time (T1) Reduce water retention time (T3) Increase water retention time (T3) Enable longer pause before retention fill NOTES: for Wiring 1. Distances are from source to unit and back to source. 2. Distance from power source to remote intake pump MUST be included when determining total distance. Same wire size MUST be used for lower base and remote intake pump. 3. Recommended conductor wire minimum AWG (mm²) for 3% voltage drop. 4. Recommended conductor sizes are based on 105 C rated insulation. Single conductor (not bundled), refer to ABYC Standards for sizes with other insulation ratings. 5. For 120/240 VAC units, use 12VDC specifications from transformer to unit. CONVERSIONS Wire - AWG to mm 2 AWG 16 14 12 10 8 6 4 2 mm 2 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 Feet to Meters Feet 10 15 20 25 30 40 50 Meter 3.1 4.6 6.1 7.6 9.2 12.2 15.2 4

Recommended Wire and Fuse/ Breaker Sizes ATLANTES FREEDOM VORTEX VAC AND MARINE ELEGANCE Table 1-Sea Water Model (sizes based on both inlet and discharge amps added) Breaker/ fuse size (amps) Toilet Discharge Amps draw Remote Pump Only Amp draw 10 feet 15 feet 20 feet 30 feet 40 feet 50 feet 12 VDC 30 18 10 10 AWG 8 AWG 6 AWG 4 AWG 4 AWG 2 AWG 24VDC 20 10 5 16 AWG 14 AWG 12 AWG 12 AWG 10 AWG 8 AWG Breaker/fuse size (amps) Table 2- Pressurized Freshwater Model Amp draw 10 feet 15 feet 20 feet 30 feet 40 feet 50 feet 12 VDC 25 18 10 AWG 10 AWG 8 AWG 6 AWG 6 AWG 4 AWG 24 VDC 15 10 16 AWG 16 AWG 14 AWG 12 AWG 10 AWG 10 AWG SEAERA QC MODEL 162 Table 3- Sea Water Model(sizes based on both inlet and discharge amps added) Breaker/ fuse size (amps) Toilet Discharge Amps draw Remote Pump Only Amp draw 10 feet 15 feet 20 feet 30 feet 40 feet 50 feet 12 VDC 25 13 10 10 AWG 8 AWG 6 AWG 6 AWG 4 AWG 4 AWG 24VDC 15 7.5 5 16 AWG 14 AWG 12 AWG 10 AWG 10 AWG 8 AWG Table 4- Pressurized Freshwater Model Breaker/fuse size (amps) Amp draw 10 feet 15 feet 20 feet 30 feet 40 feet 50 feet 12 VDC 25 13 12 AWG 10 AWG 10 AWG 8 AWG 6 AWG 6 AWG 24 VDC 15 7.5 16 AWG 16 AWG 14 AWG 12 AWG 10 AWG 10 AWG Table 5 - Remote Intake Pump Only Breaker/fuse size (amps) Amp draw 10 feet 15 feet 20 feet 30 feet 40 feet 50 feet 12 VDC 15 10 14 AWG 12 AWG 10 AWG 10 AWG 8 AWG 6 AWG 24 VDC 10 5 16 AWG 16 AWG 16 AWG 16 AWG 14 AWG 12 AWG 5

WARNING: Hazard of Shock and Fire Always use proper wire, wire connectors and fuse/circuit breaker. See Specification Chart. Secure wire properly. Do not connect appliances to toilet circuit. Make sure power is off before proceeding. Use proper wire terminals for all wire connections. 1. Determine proper wire size by measuring distance from: Power Source to control box and back to power source. Remote pump units -determine proper wire size for remote pump from wiring diagram. 2. Select proper wire and fuse/circuit breaker size from Specifications on Table 1. 3. Install fuse/circuit breaker in positive line at source. 4. Wire control to the toilet and battery using one of the following wiring diagrams. MSD OPERATION To start Electroscan from toilet control, run a wire from to MSD to terminal marked EXT TRIG inside Electroscan control module (black box) (See Fig 5). To start toilet equipped with Smart toilet control from Electroscan, connect Head1 to FROM MSD ( See Fig 6). For Lectra/San MC, EC call Raritan Customer Service Fig. 2 FOR SMART TOILET CONTROL, FRESHWATER MODEL 6

Fig. 3 FOR SMART TOILET CONTROL REMOTE PUMP MODEL Fig. 4 FOR SMART TOILET CONTROL SEA/FRESH MODEL 7

Fig. 5 FOR SMART TOILET CONTROL WITH MSD PURA/SAN EX ELECTROSCAN Fig. 6 FOR SMART TOILET CONTROL WITH MSD PURA/SAN EX ELECTROSCAN FOR LIMITED WARRANTY TERMS AND CONDITION PLEASE REFER TO TOILET MANUAL 530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 s 8