Feasible Series Compensation Applications using Magnetic Energy Recovery Switch (MERS)

Similar documents
Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

ELEMENTS OF FACTS CONTROLLERS

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Modeling of Conduction EMI Noise and Technology for Noise Reduction

Improvement in Reactive Power Consumption of Line Commutated HVDC Converters for Integration of Offshore Wind-Power

ATYPICAL high-power gate-turn-off (GTO) currentsource

I. INTRODUCTION IJSRST Volume 3 Issue 2 Print ISSN: Online ISSN: X

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Efficiency Improvement of High Frequency Inverter for Wireless Power Transfer System Using a Series Reactive Power Compensator

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

CONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS

Laboratory Investigation of Variable Speed Control of Synchronous Generator With a Boost Converter for Wind Turbine Applications

Power Quality enhancement of a distribution line with DSTATCOM

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

SHUNT ACTIVE POWER FILTER

Large PWM Inverters for Rolling Mills

RECENTLY, the harmonics current in a power grid can

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

POWER ELECTRONICS. Converters, Applications, and Design. NED MOHAN Department of Electrical Engineering University of Minnesota Minneapolis, Minnesota

Investigation of D-Statcom Operation in Electric Distribution System

Design and Simulation of Passive Filter

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Chhattisgarh Swami Vivekanand Technical University, Bhilai

Volume I Issue VI 2012 September-2012 ISSN

B.Tech Academic Projects EEE (Simulation)

A Novel Single-Stage Push Pull Electronic Ballast With High Input Power Factor

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Chapter 10: Compensation of Power Transmission Systems

Modeling and Simulation of STATCOM

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Damping of Sub synchronous Resonance Using SSSC Based PWM Hysteresis Controller

The High Power IGBT Current Source Inverter

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

Three Phase Automatic Voltage Regulator Using Microcontroller

Designing Of Distributed Power-Flow Controller

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

Oscillators. An oscillator may be described as a source of alternating voltage. It is different than amplifier.

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

Power Control Scheme of D-Statcom

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

IEEE ISIE 2005, June 20-23, 2005, Dubrovnik, Croatia /05/$ IEEE 423

Type of loads Active load torque: - Passive load torque :-

An Experimental Verification and Analysis of a Single-phase to Three-phase Matrix Converter using PDM Control Method for High-frequency Applications

Optimization of High Voltage IGCTs towards 1V On-State Losses

SRI VIDYA COLLEGE OF ENGG AND TECH

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Active Elimination of Low-Frequency Harmonics of Traction Current-Source Active Rectifier

shunt (parallel series

A Review on Mid-point Compensation of a Two-machine System Using STATCOM

Module 1. Introduction. Version 2 EE IIT, Kharagpur

Compare Stability Management in Power System Using 48- Pulse Inverter, D-STATCOM and Space Vector Modulation Based STATCOM

A New Network Proposal for Fault-Tolerant HVDC Transmission Systems

A New Control Scheme for Power Quality Improvement with STATCOM

Generator Advanced Concepts

Power Factor and Power Factor Correction

Modern Concepts of Energy Control Technology through VVVF Propulsion Drive

Literature Review. Chapter 2

Cascaded Two Level Electrical Converter-Based Multilevel STATCOM for High Power Utilization

The unified power quality conditioner: the integration of series and shunt-active filters

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

( ) ON s inductance of 10 mh. The motor draws an average current of 20A at a constant back emf of 80 V, under steady state.

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

Comparison of Power Factor Correction Techniques for Generator-Sets for SHEVs

A Review on Simulation and Implementation of Thyristor controlled reactor and Shunt Hybrid Power Filter

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

II. RESEARCH METHODOLOGY

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

CHAPTER 1 INTRODUCTION

COOPERATIVE PATENT CLASSIFICATION

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

UNDERSTANDING SUB-HARMONICS

APPLICATION OF INVERTER BASED SHUNT DEVICE FOR VOLTAGE SAG MITIGATION DUE TO STARTING OF AN INDUCTION MOTOR LOAD

Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 8 Issue 1 APRIL 2014.

A cost effective hybrid HVDC transmission system with high performance in DC line fault handling

Voltage-Current and Harmonic Characteristic Analysis of Different FC-TCR Based SVC

ADVANCED CONTROLS FOR MITIGATION OF FLICKER USING DOUBLY-FED ASYNCHRONOUS WIND TURBINE-GENERATORS

COMPARISON OF POWER QUALITY SOLUTIONS USING ACTIVE AND PASSIVE RECTIFICATION FOR MORE ELECTRIC AIRCRAFT

3.1.Introduction. Synchronous Machines

Transcription:

Feasible Series Compensation Applications using Magnetic Energy Recovery Switch (MERS) Jan A. Wiik, Takanori Isobe, *Taku Takaku, F. Danang Wijaya, Kazuhiro Usuki, Nobuyuki Arai and Ryuichi Shimada Tokyo Institute of Technology N1-33, 2-12-1 O-okayama, Meguro-ku, Tokyo, Japan Email: jan.wiik@nr.titech.ac.jp *Fuji Electric Device Technology Co., Ltd. 4-18-1, Tsukama, Matsumoto, Japan Keywords <<Converter circuit>>, <<Electronic ballast>>, <<FACTS>>, <<Generator excitation system>>, <<Power factor correction>> Abstract Different series compensation applications by using the Magnetic Energy Recovery Switch are reviewed. The Magnetic Energy Recovery Switch is a variable series compensation device characterized by simple configuration and control as well as a large operating range. Three different applications areas are introduced; Load control, generator power capability improvements and series compensation in transmission systems. Load control application seems promising for cases where control of the frequency is not a necessity, such as for fluorescent lamps. By using MERS in series with permanent magnet generators can the output power capability of the generator be increased. At the high power end, MERS is discussed for use as a series compensator in transmission systems, where the power flow can be controlled and increased. In summary, the paper suggests a wider use of series compensation in electrical systems. Introduction Use of series compensation in electrical systems has a long history with applications in the low voltage to the high voltage range. In weak distribution grids, series compensation is used as an effective way to improve the voltage profile during variable loading conditions and also to reduce voltage flicker resulting from e.g. starting of induction motors. For the transmission systems, the series capacitor has been used to increase the transmission capacity of long power lines by reducing the equivalent reactance. The Magnetic Energy Recovery Switch (MERS) has been suggested as a new variable series compensator. With a simple configuration using line frequency switching, low losses and low cost implementation is possible. The purpose of this paper is to review and investigate applications of this new series compensation configuration. The first part of the paper introduces the MERS and its operation. The second part describes some possible MERS applications including experimental results. This is followed by a discussion and a conclusion. Magnetic Energy Recovery Switch (MERS) The Magnetic Energy Recovery Switch (MERS) consists of 4 forced commutated switches and a small dc-capacitor [1]. The configuration is similar to that of a single phase full bridge, but the control is different and the size of the capacitor is several times smaller. By controlling the path of the current through the device (Fig. 1), the size of the injected series voltage can be controlled. Examples of resulting curves are shown in Fig. 2. Three modes of operation are indicated. The not-continuous and the dc-offset mode results by turning two and two switches on/off in pairs while the active by-pass mode results when actively by-passing the capacitor for a part of the period by using pattern Fig. 1c. The

+ V 0 1 Figure 1: Possible current paths through the MERS when current is going from left to right. Capacitor Voltage Series Voltage Current (dotted) 1 0 1 0 1 Not continuous Dc offset Active by pass Time Figure 2: Example of resulting voltage and current curves when controlling the MERS. resulting current wave form depends on the application; however, it will always be 90 degrees to the injected series voltage. Important features of the MERS operation are: Line frequency switching, one switch is only turned on and off once during an electrical cycle. The size of the capacitive injected series voltage can be varied from zero to rated voltage within the current rating of the device. The series voltage injection capability stays constant even with varying frequency. Losses are similar to if the current continuously goes through one diode and one active switch. Harmonic distortion changes dependent on control set-point. When operated in dc-offset mode, the control of gate signals will automatically control the phase of the current [2]. Depending on the application, the control will change. Details regarding this are included in the application section. Series compensation applications using MERS Load control With the coming of power electronics and power converters, new load control applications were developed, such as motor drives. The purpose of these power converters is to control the voltage magnitude and also the applied load frequency. However, in cases where only load voltage control is needed, there might be potential for using simpler series compensation devices.

Figure 3: Illustration of load voltage control with MERS. The load voltage can be controlled by controlling the phase of the current in relation to the connecting grid voltage. Load control using series compensation is illustrated in Fig. 3. The load voltage can be controlled from a maximum value to zero. The power factor is reduced for load voltages lower than rated and will be in the leading area. The load voltage and connecting power factor can not be controlled independently. The control of the MERS according to the illustrated principle is very simple. A possible implementation is to identify the zero crossing of the grid side voltage, and vary the gate signals accordingly. Two and two switches are switched on and off in pairs. By doing this, the direction of the injected voltage phasor can be controlled [3]. Light intensity control of fluorescent lamps is used in the following to illustrate the operation of the MERS circuit for load voltage. Light intensity control of fluorescent lamps is difficult with the use of triacs due to zero current periods. Several electronic ballast configurations exists, however with increased complexity. These solutions are normally based on high frequency switching and the use of reduced sized magnetic ballast, meaning that existing lamp installations not can be used directly. For reduced power output of fluorescent lamps(dimming) it has been suggested that the efficiency with normal magnetic ballasts is higher than that for electronic ballasts [4]. This indicates the feasibility of lamp dimming by controlling the applied voltage and not the frequency. MERS is investigated as such a possible solution by using the configuration in Fig. 4. The experimental results showed that the light intensity could be controlled by using the MERS. Stable light output could be achieved down to an input power of 50 percent. Experimental results are shown in Fig. 5. Some observations are: Some distortion in the current wave form. Power factor is improved for increasing input power. The relative losses are reduced for reducing power outputs. Control power of approximately 1W is not included in the graph. The light intensity can be controlled by simple phase-shifting the gate signals according to the input voltage.

Figure 4: Configuration of experimental set-up used to study the use of MERS for controlling light intensity of fluorescent lamps. Figure 5: Resulting curves when using MERS to control the light intensity of the lamp. Left side shows resulting curves for two different power outputs. The right side shows variations in power factor and losses as a function of input power. Due to the use of line frequency switching and MOSFETs, the gate drive can be simplified and cost reduced. Photovoltaic output devices (TLP190) were used for the experiments, having relatively slow but sufficient response for this application. During start-up of fluorescent lamps, large currents may occur. To protect the MERS device from high capacitor voltage, the MERS device is by-passed during this period by using current path given in Fig. 1c or Fig. 1d. The experiments were performed with glow starter type lamps. By using rapid starter type lamps with initial unity power factor, the resulting power factor and current distortion will also improve. This is due to the reduced size of the series injected voltage for a given load voltage. The distortion can also be improved by the selection of capacitor size. A detailed discussion regarding this is beyond the scope of this paper. Generator output power improvements Synchronous generators are characterized by a large synchronous reactance. Due to the resulting voltage drop across the reactance, the excitation level must be increased when the output power increases. The MERS has been suggested as a way to increase the maximum output power level for a given field excitation [5][2]. This can be performed by compensating the whole or parts of the voltage drop across the synchronous reactance. Fig. 6 illustrates the principle of MERS control in combination with synchronous generator (generator parameters used are the same as for experimental set-up). The left part shows the resulting phasor diagrams for the case without MERS and with two different MERS controls. For the case without the MERS, it is clear that there is a substantial voltage drop due to the synchronous reactance, especially for increasing currents. One suggested use of MERS is to control the generator voltage to 1 per unit (constant voltage control). This means that only parts of the voltage drop across the synchronous reactance is cancelled. Another method is to control the current such that it is oriented according to the internal

Figure 6: Illustration of principle when using MERS to improve the output power capability of synchronous generators. generator voltage, E. This results in maximum power capability for a given output current(maximum power control). However, the result is a higher terminal voltage with possible need for special design. The right part of Fig. 6 compares the three cases for different currents and keeping constant no load excitation. When analyzing the steady state power capability, the current is not allowed to exceed the rated current. With this constraint, the maximum power capability is increased with around 40 percent for the case with MERS and constant voltage control, and with around 48 percent for the case with maximum power control. The maximum power output for the case without MERS occurs before rated current is reached. On the other hand, by increasing the current above rated current and by using MERS control, the output power can be further increased. Based on this, the MERS can be said to be able to increase the short term over-load capacity of the generator substantially and well above the steady state power capacity. Some experiments were conducted in order to verify the output power improvements by using MERS. The set-up is shown in Fig. 7, and constant voltage control of the MERS was used. The excitation was adjusted during no-load such that rated voltage was achieved. After this, constant excitation current was kept. The purpose using constant excitation was to imitate the characteristics of a permanent magnet generator. As a result, the voltage at rated current with no MERS is reduced as well as the power rating of the generator. The experimental results are shown in Fig. 8. Due to the use of a diode bridge as an active load, there is substantial distortion in the waveforms. The right part of the figure summarizes the results for the case with and without MERS. The case with MERS shows output power improvements of around 34 percent compared to the case without MERS. The estimated values shown in Fig. 8 are based on ideal conditions with pure sinusoidal waveforms and only considering the synchronous reactance. In the real case, the waveforms are distorted due to the diode bridge. Additionally, a dc-current excitation type synchronous generator was used. Due to the field

Figure 7: Configuration of experiment performed with synchronous generator and MERS. Figure 8: Experimental results with synchronous generator, MERS and diode load. Left side shows time trends, while the right side shows results when applying different sized dc-currents at the dc-load. windings, the transient reactance will be smaller than the synchronous reactance. These two factors are believed to be the reason for the deviation between the estimated and actual experimental data. Characteristics when using the MERS for power capability improvements of synchronous generators can be summarized as: The steady state power capability is increased by canceling parts or all of the voltage drop across the synchronous reactance in cases with constant field excitation (e.g. permanent magnet generators) The short term power capability can be increased substantially. Difference in power capability improvement resulting from MERS control with constant generator voltage control or maximum power control is not large. Maximum power control of MERS results in increased generator terminal voltage, meaning constant generator voltage control might be an attractive solution. The capability of the MERS to operate during variable frequency makes the configuration especially suited for applications such as wind power generators. Series compensation in transmission systems Series compensation is typically used to improve the transmission capacity and to control the flow of power in the case of parallel transmission paths. Series compensation have a long history in transmission

Figure 9: Configuration of experimental set-up used to study the use of MERS for controlling the power flow in transmission systems. Figure 10: Experimental results when using MERS as a power flow controller. The left part shows the response when changing the minimum capacitor and by-pass length set-points. The right part shows the resulting loop current when changing the size of the injected series voltage. systems since the first series capacitor installation at Ballston in 1928 [6]. The shaft failure at Mohave power station in 1970 gave awareness of the problem with sub-synchronous resonance [7]. Due to the limitation of series capacitors, new power electronics based technologies were developed and are referred to as Flexible AC Transmission System (FACTS) controllers [8]. MERS has been suggested as a new series FACTS controller [9]. The configuration shown in Fig. 9 is used to investigate the behavior of the MERS. In the case of load control, the MERS is operated to control the phase of the injected voltage of the phase of the current. When being used in power transmission, it is more important to control the size of the injected series voltage since this has a direct influence on the flow of power. Control of the size of the MERS voltage is performed by controlling the minimum capacitor voltage and the length of the by-pass period [9], by utilizing the active by-pass type of control (Fig. 2). In order to perform this control, it is necessary to have phase information of the current as well as direct measurement of the capacitor voltage. This leads to some more complexity compared to the load control applications. Experimental results for the transmission system application are shown in Fig. 10. The left part shows the response with a step in set-point to the controller. It can be found that the new minimum capacitor voltage set-point is quickly reached. It takes approximately 2 cycles before the injected series voltage stabilizes. This is due to the MERS having similar characteristics to a series connection of a voltage source and a capacitor [9]. The right part of the figure shows the steady state loop current flow for various injected series voltages. Three different power source voltages were applied, leading to different resulting current for a given series voltage. By adjusting the size of the MERS series voltage, the flow of power can be controlled. Important characteristics when using the MERS as a power flow controller are:

Large operating range, being able to inject up to rated series voltage also for low currents. This is the same capacitive voltage range as for the Static Synchronous Series Compensator, by using a simpler configuration. Line frequency switching is used, meaning high power semiconductors based on Gate Turn-off Thyristor technology can be used. Promising sub-synchronous characteristics, mainly acting as resistor for sub-harmonic frequencies [10]. Potential for simple over-current protection by quickly entering parallel by-pass mode without destructive GTO turn-offs [11]. Discussion Three different application areas of the MERS have been discussed. Firstly, series compensation has been shown to be a possible solution for load control concerning both voltage control and power factor correction. The suggested load control method controls the phase of the current into the lead area. This means reactive power is fed into the grid from the load. On one side, this is a benefit since most loads consume reactive power and local supply of reactive power can reduce transport of reactive power and resulting grid losses. On the other hand, if the load in an area is dominated by reactive power producing loads, care must be taken to make sure grid voltages are kept within their limits. Load control with series compensation means that the frequency can not be controlled and the application range becomes less than that of converter solutions. Applications such as fluorescent lamp intensity control seem promising, where MERS offers a simpler solution than that of the high frequency converter configurations. Permanent magnet generators are getting more common with price reduction on permanent magnets as well as the coming of slow rotating generator applications such as in the area of wind power. Due to the inability to control the field excitation of these generators, the maximum output power is limited. MERS has been shown to be a possible solution to improve the output power. In principle a fixed series capacitor could be used to cancel half of the synchronous reactance of the generator and result in similar characteristics. Due to the resonance characteristics of the fixed series capacitor in series with an inductance, potential stability problems might occur; however, this has not been investigated in detail. If the generator system shall be able to operate during variable frequency, the use of fixed series capacitors is difficult due to the changing reactance of the capacitor. Additional, having a variable compensation device means that the power going out of the generator can be actively controlled. Fixed series capacitor has been used for many years in transmission systems and this is likely to continue. MERS is suggested as a new series FACTS device and is in this respect one of many technologies. Work is currently in progress to compare the MERS technology to the existing technologies. Conclusion The Magnetic Energy Recovery Switch(MERS) has been shown to be a possible solution for low power to high power applications. The size of the injected series voltage can with simple control be controlled from zero to rated voltage within the current rating of the device. Load control application seems promising for cases where control of the frequency is not a necessity, such as for fluorescent lamps. By using MERS in series with permanent magnet generators can the output power capability of the machine be increased. At the high power end, can the power flow be controlled and increased by using MERS for series compensation in transmission systems. In summary, the paper suggests a wider use of series compensation in electrical systems. References [1] K. Shimada, T. Takaku, T. Matsukawa, and R. Shimada. Bi-directional current switch with snubber regeneration using p-mosfets. Proc. International Power Electronics Conference, (4):102 103, April 2000. [2] Jan A. Wiik, Taku Takaku, Fransisco Danang Wijaya, Tadayuki Kitahara, and Ryuichi Shimada. Improvement of synchronous generator characteristics using bi-directional current phase control switch. EPE-PEMC, 2006. [3] Jan A. Wiik, Takanori Isobe, Taku Takaku, Tadayuki Kitahara, and Ruyichi Shimada. Application of series connected current control switches for power factor correction. PCIM Europe, 2006. [4] S. Y. R. Hui, W. Yan, H. Chung, P. W. Tam, and G. Ho. Energy efficiency comparison of dimmable electromagnetic and electronic ballast systems. IAS Annual Meeting, 2005.

[5] T. Takaku, G. Homma, S. Igarashi, Y. Uchida, and R. Shimada. Power up and efficiency improvement of wind turbine generator by magnetic energy recovery switch. IPEC-Niigata 2005, 2005. [6] E. K. Shelton. The series capacitor installation at ballston. General Electric Review, 31:432 434, 1928. [7] M. C. Hall and D. A. Hodges. Experience with 500kv subsynchronous resonance and resulting turbine generator shaft damage at mohave generating station. IEEE Publication 76 CHI066-0- PWR, pages 22 29, 1976. [8] N. G. Hingorani and L. Gyugyi. Understanding FACTS, Concepts and Technology of Flexible AC Transmission Systems. IEEE Press, 1999. [9] Jan A. Wiik, F. Danang Widjaya, Takanori Isobe, Tadayuki Kitahara, and Ryuichi Shimada. Series connected power flow control using magnetic energy recovery switch (mers). PCC Nagoya, 2007. [10] Jan A. Wiik, F. Danang Wijaya, and Ryuichi Shimada. An innovative series connected power flow controller, magnetic energy recovery switch (mers). PES General Meeting, 2007. [11] Jan A. Wiik, F. Danang Wijaya, and Ryuichi Shimada. Robust series compensation in power systems using magnetic energy recovery switch (mers). IEEJ, SPC-07-70, June 2007.