DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands

Similar documents
DIC Imaging using Laser Scanning Microscopes (LSMs) on Axio Imager Stands

Motorized Axio Observer Start-up instructions

Nikon Ti-E Microscope Manual. Rightmire Hall Ohio State University. Director: Tony Brown Rightmire

INSTRUCTIONS FOR COURSE WORK 4 (AxioVert) Instructor: Anne Vaahtokari (MIU) 1. Purpose of the work

Nikon E800 Operating Instructions.

Characterization Microscope Nikon LV150

MIF ZEISS VIOLET CONFOCAL ZEN 2009 PROTOCOL

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

Guide to Confocal 5. Starting session

BX-61: Brightfield Instruction /Continue to scroll for Fluorescent Instuctions

Zeiss LSM 880 Protocol

Operating Checklist for using the Laser Scanning Confocal Microscope. Leica TCS SP5.

Imaging Introduction. September 24, 2010

Leica TCS SP8 Quick Start Guide

ZEISS LSM 710 CONFOCAL MICROSCOPE USER MANUAL

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

EPIFLUORESCENCE &/OR BRIGHTFIELD MICROSCOPY

Leica SP8 TCS Users Manual

b. Turn the power switch and key to on position for blue laser.

Microscopy. Matti Hotokka Department of Physical Chemistry Åbo Akademi University

Indian Institute of technology Madras Presents NPTEL NATIONAL PROGRAMME ON TECHNOLOGY ENHANCED LEARNING

ZEISS LSM 710 NLO Multiphoton microscope Manual/Quick guide

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Nikon Eclipse Ti A1-A Confocal Operating Manual. Start-up. Microscope

Zeiss Axio Imager.A1 manual

Topics. - How to calibrate the LSM scanner. - How to clean the microscope. - How to adjust the pinhole alignment. - How to adjust the Collimator

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Quick Start Guide. Leica SP5 X

Nikon E800 Operating Instructions.

Nikon E800 Microscope. Operating Instructions

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Things to check before start-up.

Easy Kohler Illumination Method

2/4/15. Brightfield Microscopy! It s all about Magnification..! or is it?!

Leica SP8 TCS Users Manual

Microscopy from Carl Zeiss

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Operating Instructions for Zeiss LSM 510

Training Guide for Carl Zeiss LSM 7 MP Multiphoton Microscope

Zeiss Axioskop II. The AIF's "routine" light microscope. (Installed 8/24/04)AxioCam installed July 11th 2005

Simplified Instructions: Zeiss Brightfield Microscope S1000

Using the Nikon TE2000 Inverted Microscope

Leica TCS SP8 Quick Start Guide

LSM 800 Confocal Microscope Standard Operation Protocol

Zeiss Axiovert 135 Fluorescence Microscope Quick Guide / Operations Manual (v. 1.0 February 09)

Training Guide for Carl Zeiss LSM 880 with AiryScan FAST

Leica SPEII confocal microscope. Short Manual

Zeiss 880 Training Notes Zen 2.3

Bio 407. Applied microscopy. Introduction into light microscopy. José María Mateos. Center for Microscopy and Image Analysis

Figure 3.4 Approximate size of various types of cells. ~10 um. Red Blood Cells = mm 1500 um. Width of penny Pearson Education, Inc.

Olympus Fluoview 1000S Spectral Confocal Microscope Introduction to the NRI-MCDB Microscopy Facility Spectral Confocal Microscope

STRUCTURE OF THE MICROSCOPE

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

Practical work no. 3: Confocal Live Cell Microscopy

Zeiss AxioImager.Z2 Brightfield Protocol

Leica SP8 Resonant Confocal. Quick-Start Guide

Instructions for Making On-Line Reservations for Microscopes in NB11-204

Manual for BMS E1 eplan series, compound microscope

CFIM MICROSCOPY COURSE PROGRAMME PRINCIPLES OF MICROSCOPY CONFOCAL AND FLUORESCENCE MICROSCOPY

Chapter 2 Alignment C. Robert Bagnell, Jr., Ph.D., 2012

Leica DB LB Research microscope and Studo Lite Imaging software

Zeiss LSM 780 Protocol

STEINDORFF METALLURGICAL MICROSCOPE. NYMCS-620 Instruction Manual

OPERATING INSTRUCTIONS

Chapter 1 Parts. Figure 1.1. Parts of a Compound Light Microscope

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

Leica DMi8A Quick Guide

LSM 710 Confocal Microscope Standard Operation Protocol

Leica Confocal - 2. Instructions for Leica SP2 Confocal Equipped with Visible Laser Lines

ML7520 ML7530 DIOPTER ADJUSTMENT RING BINOCULAR BODY, INCLINED 30. (a) Field Iris Control Lever. (c) Filter Slots EYEPIECES, KHW10X

The Compound Microscope. Brightfield: Köhler Illumination

Confocal 510 Tutorial

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

OPTICAL PRINCIPLES OF MICROSCOPY. Interuniversity Course 28 December 2003 Aryeh M. Weiss Bar Ilan University

Zeiss 780 Training Notes

OMM300. Inverted Metallurgical Microscope

Microscopic Structures

LSM 780 Confocal Microscope Standard Operation Protocol

START-UP PROCEDURE 1 THE MICROSCOPE STAND 3 OBJECTIVES 5 STARTING WITH LAS (SOFTWARE) AND SETTING UP THE MICROSCOPE STAND 7

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Practical Light Microscopy

Zeiss LSM 510 Confocor III Training Notes. Center for Cell Analysis & Modeling

Zeiss LSM 510 Multiphoton Confocal Microscope

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

WITec Alpha 300R Quick Operation Summary October 2018

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

Widefield-NikonEclipseTE200-ORCA Nikon Eclipse TE200 Inverted Microscope with Hamamatsu 1394 Orca-ER Cooled CCD Camera and Micromanager Software

Contents. Introduction

Olympus LEXT OLS 4000 Confocal Laser Microscope

REMEMBER: You have 5GB of disk space on this microscope. Check before you start if you have room for your experiment. If not delete your old data.

LSM 510 Training Notes

ANSWER KEY Lab 2 (IGB): Bright Field and Fluorescence Optical Microscopy and Sectioning

A BRIEF INTRODUCTION TO MICROSCOPY The two key properties of a microscope that allow you to see microbes are resolution and magnification.

TRAINING MANUAL. Olympus FV1000

The invention of the microscope made it possible for scientists to view and study cells. Cells the basic units of all living organisms.

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Microscopy Techniques that make it easy to see things this small.

Eyepieces KHW10X. Diopter Adjustment Ring. Binocular Body Inclined 30. Binocular Clamp Screw. Analyzer control Lever. Reflected Light Illuminator

Simplified Instructions: Olympus Widefield Microscope S1230

Transcription:

DIC Imaging using Laser Scanning Microscopes (LSM) on Inverted Stands Differential Interference Contrast (DIC) imaging is a technique used to increase contrast in brightfield images. In confocal systems, DIC images can be acquired simultaneously with fluorescence images and can provide useful morphological information. This manual provides instructions for setting up DIC imaging using a laser scanning microscope (eg. LSM 780, LSM 710, LSM 700, LSM 510, LSM 5 Exciter, LSM 5 Pascal) with Axiovert 200 or Axio Observer stands. Please note the system must be equipped with a T-PMT in order to collect DIC images. Any questions or concerns can be directed to the ZEISS Product and Applications Support group at 1-800-509-3905 or Support@zeiss.com

Figure 1: Diagram of the AxioObserver 2 Carl Zeiss MicroImaging Maya Everett

Step 1: Match DIC Slider to Objective Each lens has a specific DIC slider. Be sure that the lens that is used for imaging has a matching DIC slider inserted. Figure 2: A typical ZEISS lens (left) and DIC slider (right) The DIC slider fits directly below the objective lens. Be sure that the DIC slider is fully inserted in the correct orientation. It will only slide fully into position if it is correctly oriented (see Figure 3). Figure 3: The DIC slider fits under the lens and must be in the correct orientation. Step 2: Match DIC prism to the DIC slider The DIC slider will have a Roman numeral I, II, or III printed on it. Select the appropriate I, II, or III prism in the condenser (Figure 1, #19). The prisms are moved manually unless you have a motorized stand, in which case there will be buttons present on the condenser that you can use to select the appropriate prism. Step 3: Adjust for Koehler Illumination 1. Focus a low power lens (10x or 20x magnification) on a test sample, such as Convallaria, using the transmitted light (halogen lamp illumination). 3 Carl Zeiss MicroImaging Maya Everett

Figure 4: How to turn on the transmitted light in AIM (left) and ZEN (right) software. Be sure that you have selected for Ocular mode to view the sample through the eyepieces. 2. Move the condenser to the lowest position (towards the sample) using the knob shown in Figure 1 and labeled as #17. 3. Open the aperture diaphragm all the way (move the wheel shown in Figure 1 and labeled #20 completely counter-clockwise). 4. Close the luminous-field diaphragm (shown in Figure 1 and labeled #16) until the edges are visible, as exemplified in Figure 5. Figure 5: In the left image the luminous field diaphragm is completely open. Close it until you see the edge of the shadow, as shown on the right. 5. Focus the condenser using the knob shown in Figure 1 and labeled #17 until the edges appear sharp. See Figure 6 for an example of this. 4 Carl Zeiss MicroImaging Maya Everett

Figure 6: These images compare what the image will look like before focusing the condenser (left) and after focusing the condenser (right). 6. Center the image of the luminous-field diaphragm with the centering screws, shown in Figure 1 as #15 and #18. An example of this is shown in Figure 7. Figure 7: These images compare what the image will look like before centering the luminous field diaphragm (left) and after centering the luminous field diaphragm (right). 7. If you plan on using a higher magnification lens, move that lens into place. Then open the luminous-field diaphragm (shown in Figure 1 and labeled #16) until the edges are just outside the visible region through the eyepieces. This is illustrated in Figure 8. Figure 8: These images compare what the image will look like before opening the luminous field diaphragm (left) and after opening the luminous field diaphragm (right). 8. Remove one eyepiece (shown in Figure 1 as #13) to view the back focal plane of the microscope. 9. Close the aperture diaphragm (shown in Figure 1 as #20) so it illuminates approximately 80% of the field of view. Figure 9 illustrates this. 5 Carl Zeiss MicroImaging Maya Everett

Figure 9: These images compare what the image will look at before opening the aperture diaphragm (left) and after closing the aperture diaphragm to 80% (right). 10. Replace the eyepiece. 11. Load your experimental sample. **The field size and the objective aperture are different for each lens. If a different lens is selected for imaging, these must be adjusted accordingly** Step 4: Configuring the Transmitted Light Channel in AIM or ZEN DIC images can be simultaneously collected with a fluorescent image using any laser line. Select Channel D or T-PMT in the Configuration Control or Light Path menu to acquire a DIC image. Be sure to select an excitation laser. Figure 10: DIC images are collected in the detector labeled ChD in AIM (shown on the left) or T PMT in ZEN (shown on the right). Once the transmitted light channel has been selected in the Configuration Control / Light Path, the gain and offset can be set similarly to a fluorescent channel. Increase the gain until the channel image just turns white and then decrease the offset to bring out the structures. Laser power can also be adjusted to increase or decrease intensity. These adjustments are controlled in the software, as shown in Figure 11. 6 Carl Zeiss MicroImaging Maya Everett

Figure 11: Detector gain, amplifier offset and laser power are used to balance the DIC image in AIM (left) or ZEN (right). Step 5: Final Touches There are two final adjustments that can be made to qualitatively optimize the image by increasing/decreasing contrast and resolution. The shear on the Wollaston prism can be adjusted by turning the screw in the DIC slider either clockwise or counterclockwise. This is performed while scanning an image and qualitatively assessing the resulting image. Figure 12: Turn the screw in the DIC slider to adjust the shear on the Wollaston prism. Adjust the rotatable polarizer (as shown in Figure 1, #14) until the intensity of the image is lowest to create a proper DIC image. 7 Carl Zeiss MicroImaging Maya Everett