Supercal 531 Multi function Integrator that lives up to Your highest expectations

Similar documents
INFOCAL 8 Energy calculator

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SVM F22. Calculator for heating or cooling applications. Data sheet

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SONOMETER TM 1100 Ultrasonic compact energy meter

Brunata Optuna H. Properties. Counter

SONOMETER TM 1100 Ultrasonic compact energy meter

MULTICAL Energy meter TS PTB. Application

Infocal 9 Energy calculator

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY COMPACT ENERGY METER MECHANICAL

SonoMeter 31 Energy Meters

RAY MC COMPACT ENERGY METER MECHANICAL

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

RAY MC COMPACT ENERGY METER MECHANICAL

ULTRASONIC D. Compact ultrasonic heat meter

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

MULTICAL 602 DATA SHEET

Heat meter Q heat 5 US

MULTICAL 601 DATA SHEET

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

RS485 AMR Interface E350 User Manual

User s Manual. F2 Calculator. A metering component for thermal energy applications

SONOMETER TM 1000 Ultrasonic compact heat meter

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Brunata. Technical Manual for HGP-series. Volume and Energy Meters, 15 to 600 m3/h

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

B850 Boiler House Energy Monitor

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

CALEC ST Innovative solutions in energy measurement

Position Indicator with/without Limit Values

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

CONTA-ELECTRONICS. Converter Units

Remote Radio Control. WAVE Push button radio control systems

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

HMM/CHW CHW Heat Meters

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

MULTICAL 302 DATA SHEET

SonoSelect 10 and SonoSafe 10 Energy Meters

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

SINGLE PHASE STS PREPAID METER

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Pulse Scaler for DIN Rail Attachment

The wireless alternative to expensive cabling...

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

B850 Boiler House Energy Monitor

HDU-SF (Horizontal Distribution Units - Single Flat)

PM8005/6 PM8005/6. Panel Meter Panel Meter. AC and DC supply options. 5 digit LED display. Direct access menu

4-20mA, 0-10V and general process measuring bargraph displays

Price list 2018 Devices

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

PROCESS & TEMPERATURE CONTROLLERS

MT372 Three-phase electronic meter with built-in modem or RS485 communication interface

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Choose from our wide range of volume-measuring elements. Our advisers will be pleased to help you select the right ones for your needs.

Digital Multifunction Instrument - Rish Master 3440

LAUREL ELECTRONICS, INC.

Energy Management Three-phase energy meter with output modules Type EM4-DIN

S200 I/O System Units

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Optical laser distance sensors. Dimensioned drawing

Technical Information RMS621

Multi-protocol heating and cooling energy calculator

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Trip amplifier, 1 channel

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Current Clamp. 210

High Performance Process & Temperature Controllers

The wireless alternative to expensive cabling...

3-phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Meter Type EM21 72R Retro-Fit

TRMC-19 GSM/GPRS DATALOGGER. Applications. Product description. Measure and remote monitoring

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Multifunctional counter tico 772/773/774

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Acti 9 Energy Meters. iem3000 Series. Technical data sheet

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

UTM10 Series Ultrasonic Transit-time Flowmeters

Excel 800 / Excel Web II CABLE SPECIFICATIONS

Utility Communications Teleprotection Equipment TPT-200

Isolators & converters

Transcription:

n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations

Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces using state of the art multi functional technologies and a modular concept. It satisfies the customer's every wish by its easy system integration, tariff function, data logger functions, universal data transfer or connection to system processors. The Supercal 531 was designed aiming at high flexibility as top priority also keeping in mind future standards. The Supercal 531 is suitable for heat energy, cooling energy or flow measurement. The Supercal 531 is also suitable for combined energy measurement such as heating / cooling. Owing to the extensive data communication range of options, and a flexible data collection and recording, the Supercal 531 is entirely suitable for applications in district heating networks, heat cost allocation and industry installations. Flexible with almost unlimited communication possibilities As standard the Supercal 531 has an optical interface according to IEC 1107, two open collector outputs as well as two pulse inputs for integration of additional meters. When desired the standard version can become equipped aditionally with a M-Bus or radio module (factory assembly). Two of the following galvanically seperated communication modules can be connected: M-Bus interface according to EN1434 (fix or variable data structure) 2 relay outputs Up to 4 passive, freely programmable analogue outputs Modem output LON RS-232 The communication modules are reactionless and can be equipped when in operation without damaging the validity of the calibration. The integrator identifies the communication module. Owing to three communication channels that are operational in parallel, the Supercal 531 simultaneously enables data collection and the connection to several processing control and building management systems.

Supercal 531 Universal and future proofed integrator The battery or mains powered integrator is designed to connect Pt500 or Pt100 temperature sensors, two or four wire. A high-resolution temperature measurement guarantees the highest accuracy of measurement. The modular concept of the integrator enables simple and low cost replacement of the meter. For example only the certification and measurement relevant part of the integrator has to be replaced while the base part with all the connections and non-volatile memory for communication adjustment stays in place. This optimizes replacement time and reduces the costs when replacing the meter. Supercal 531 can accept volume inputs with a frequency of up to 5 Hz (battery powered) or up to 12 khz (mains powered). It can be combined with either mechanical, magnet-inductive, ultrasonic or oscillating flow sensors of up to qp 10'000 m 3 /h. Characteristics Exchangeable integrator module; the wiring base with the connections remain in place EEPROM for the communication set-up is pre-installed in the base part Communication options and functions can be equipped later and without compromising verification of the integrator Mains- or battery powered Up to 4 freely programmable analogue output Remote support available via the internet Self recognition of options and power supply M-Bus according to EN 1434 Two or for wire temperature sensors Clear customer friendly user concept Accuracy better than required by EN1434

Supercal 531 Clear display sequences Easy user readout concept The Supercal 531 features a particularly large and clearly readable LCD-display, which enables easy and customer friendly readout. The display sequences are clearly divided in 8 menus: Main menu - accumulated values Set day values 15 monthly values 32 average values 32 maximum values Configuration Service information Test and parameterization menu The cycle of the display sequence can be customized. The two push buttons enable a comfortable menu overview, customer friendly use and fast readout of measurement data. Fast access over the Internet The unique concept of the integrator enable customer support over the Internet. Configuration as well as the function controls can be operated with an access authorization distributed on the spot. Swift customer service and support becomes a reality.

Efficient functions Complete data security For control and safety reasons of the measurement results, the Supercal 531 runs a periodically self-test, and records all data every hour in a non volatile memory. When a voltage drop occurs all the values are automatically updated and registered, and when powered by mains the pulse inputs are accumulated for two more months. Efficient additional functions The Supercal 531 has various additional functions, which fulfill all the requirements of a complex measuring system: - Transmission of status messages over the transistor outputs - Alarm and threshold values for the verification of operation status - Up to three different freely programmable tariff functions - Application of solar and cooling installations up to 20 C, the mixture content can be freely programmable. The tariff or the threshold values can be used to control an actuator. The tariff functions can be loaded over the optical interface without damaging the verification seal. Measurement principle The Supercal 531, when mains powered, measures the temperatures every 3 seconds, when battery powered, every 20 seconds (with a D-type battery) and every 30 seconds (with a C-type battery). The measurement of the flow value is event controlled on the pulse input, which means that each pulse is constantly updated. Flexible power supply options The modular power supply concept offers the following options : 6 + 1 year battery 11 + 1 year battery mains powered : 230 VAC - 45/65 Hz or 115 VAC - 45/65 Hz mains powered : 24 VAC - 45/65 Hz or 12 24 VDC (or supplied by the bus) The Supercal 531 has an automatic power supply detector.

Technical data Standard version Temperature measurement Pt100 or Pt500 2- and 4-wire Absolute temperature range -20...200 C Approved range 2...200 C Absolute temperature difference 1...150K Approved range 2...150K Response limit 0.2K Temperature resolution t 0.1K Temperature resolution t 0.005K Measuring accuracy better than by EN1434-1 required Measuring cycle Temperature measurement: - 30 seconds when battery powered (Standard Type C) - 20 seconds when battery powered (Type D) - 3 seconds when mains powered Volume measurement: - Pulse volumes are constantly updated Temperatures Operating Storing and transport 5...55 C -20...70 C Test and calibration interface - NOWA - High resolution test pulses - Integrated test program - Internal simulation test Pulse inputs Input frequency Normal mode Fast mode Battery powered Mains powered Input voltage Volume pulse inputs 2 additional pulse inputs Input frequency Normal mode Fast mode Input voltage Pulse values max. 5 Hz max. 3.5 khz max. 12 khz 0...30 V 1-10-100-1000 I/pulse or 2.5-25-250-2500 I/pulse or 0.0001 9999.9 pulse/i max. 5 Hz max. 12 khz 0...30 V 0.0001 9999.9 pulse/l LCD display Display units Energy Volume Additional pulse inputs Temperature Power supply Battery Battery Mains Mains 8-digit kwh, MWh, GJ, MJ, BTU m 3, Gallon volume or energy C, F or K 6 + 1 year 11 + 1 year 115 or 230 VAC 45/65 Hz 24 VAC 45/65 Hz or 12-24 VDC 2 pulse outputs Output frequency Normal mode max. 5 Hz (+/-20%) Fast mode max. 10 khz (+/-20%) Short circuit max. 100 µa Pulse values 0.0001 9999.9 pulse/l Optical interface Hardware according to DIN IEC1107 M-Bus protocol according to EN1434 Data security Verification- and measurement relevant part EEPROM Integrator base part EEPROM Housing protection Standard IP65 Options Preassembled at factory: M-Bus or radio

Technical data Optional communication modules The communication modules can be retrofitted when in operation without damaging the verification seal. Relay module with two outputs Contact potential Cut-off current Voltage to ground Cable length Max. pulse frequency max. 100 VAC/DC, 50/100 ma 500 ma max. 100 VAC/DC, 50/100 ma max. 25 m 1 Hz Passive analog module with two outputs Power supply 9...24 VDC (external power supply) Power range 4...20 ma or 0...20 ma, 4...20 ma, 0...10 V Resistance RL max. at 24 V = 650 Ω Resolution 16 bit Max. converter error < 0.02% from end value LON module Network Transmission Power supply bus interface Connection LONWORKS 2-twisted wire, FTT-10A 24 VAC/DC, max. 50 ma 4-Pol-terminal screw RS-232 module Fix or variable data structure Potential free, reverse battery proof Transmission speed 300...38'400 baud M-Bus module Fix or variable data structure Potential free, reverse battery proof Radio module Mode Frequency Transmitting power FM, bi directional 433,82 MHz < 10mW