Swifts cable ladder couplers and fasteners

Similar documents
Swifts cable ladder ancillary items

Swifts cable ladder supports

Installation Instructions - Model V4JSD 1

EZYMESH CABLE MESH EZYMESH. Cable Support Systems

CABLE TRUNKING & ACCESSORIES

Installing the Profile Privacy Panel. Assemble top mounting bracket. Prerequisites. Tools

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

Fixings & Fastenings. Bright Zinc Plated, Galvanised & Stainless Steel. Lockinex. ea i, ea u i

aluminium profile system

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

SWITCH STAND Switch Stand Assembly Connecting Rod Target Assembly (when required) TURNOUT ACCESSORIES Standard Tie Plates Rail Anchors Joints

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

Modular Shelter Breezeway Assembly Instructions

CNC Router Parts PRO Machine Kit Cable Track Installation Instructions

Clearview Railing System Installation Instructions

User Instructions Multiline Otter Scoreboard Caddy Assembly

Verge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

UPM 6X. UPM 6X Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

Cable Tray. SF/273, 16th mile stone, Kavaraipettai-Satyavedu road, Thiruvallur T /52/53/54 F

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

C70 Window Roller Repair Taken from: Heres the problem:

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

Cabinet Mount Lifter Instructions

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11

Post & Rail Crossbuck

METAL BENDER OPERATING & MAINTENANCE INSTRUCTIONS Model Nos: CCB1 & CCB2 Part Nos: & CCB2 CCB1

CABTRAY Why you need it!

Walk-in Greenhouse. Assembly instructions. 6x4. 6x6. 6x8. Model GH0490 Model GH0491 Model GH1040. Model GH0492 Model GH0493 Model GH1041

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

FRAME BRACKET. Doing Our Best to Provide You the Best. Ford. Page 1. BOlT TORQUE SPECIFICATIONS HJ31000,Rev 0

Lab Style Table Frame Part No Assembly Guide Automation Technology

Installation Instructions Kit, Base Rail Bracket Part # 31413

Follow these steps to assemble your Hiddenbed 1 Construct the 3 main parts 2 Assemble them together 3 Add a mattress. YOUR HIDDENBED IS READY! 2

STEEL PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/

Face Mount to Through-the-Post Mount

UPM 6X Custom. UPM 6X CUSTOM Standard stock Tee socket sized for 5" schedule 40 or 80 Pipe. Page 1 of 8

CABLE TRAYS & STRUTS CATALOUGE

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

RIDGE MAST MOUNT (RMM)

The Nantucket Legacy Arbor

Parts and tools needed for installation- Cleaning and Painting -

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

INSTALLATION INSTRUCTIONS

The Nantucket Legacy Arbor

THE CASCADE & SLINGER FUNSLIDES

Wide-span cable trays WPR Assembly instruction

Evorail Guardrail has Evolved

Variable Pitch Collector Frame

Tel: +44 (0)

ALL SEASON PATIO COVER

SETUP INSTRUCTIONS If you would like to tell us about your experience with your setup instructions please us at

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

Wanco Electric & Machinery Pte Ltd. Cable Management Systems. Cable Trunking

ABSORB 350 Crash Cushion Product Specifications

Solar Panel Top-of-Pole Mounting Kit For Panels Over 100 Watts Including CMP Panels

INSTALLATION INSTRUCTIONS / DODGE RAM CREW CAB 2500/3500

Ford Pick Up Rear leaf Spring Kit Installation Instructions

Sit N Sleep Bed 758/ /5401. Assembly Instructions - Please keep for future reference

Malibu - 3 Drawer 2 Door Robe

Horizontal Cable Systems

ABW-4-SSP ABW-5-SSP 5 ABW-6-SSP 6 ABW-7-SSP 7 ABW-4-ESP ABW-5-ESP 5 ABW-6-ESP 6 ABW-7-ESP 7 ABW(*)24HSP ABW(*)36HSP. Furnished in pairs with hardware.

XL-GC03 Sliding Door Lock Installation Manual PAT XL-GC06 Sliding Door Hanger Installation Manual XL-GC08 Sliding Door Lock Guide Installation Manual

INSTALLATION INSTRUCTIONS CONTOURED LIGHT BAR APPLICATION: CHEVY EQUINOX/ GMC TERRAIN PART NUMBERS: ,

Elements Pole Mounting System

Barrier Field Manual. CSP Pacific Barrier Field Manual December 12

INSTALLING YOUR NEW SPRING LIFT ARM KIT

3. Barrier elements. Barrier posts. Stainles steel

e997 Articulating Wall Arm MANUAL IM004-03

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

NX7 SERIES 5-1/2 HANDRAIL

Assembly, Installation, Operation and Maintenance Instructions Kit, Base Rail Bracket Part # 31852

SKT-SP Tangent Terminal

Installing The Aliens Extermination Deluxe 50" Cabinet with Sintra Marquee

Downtown Rack. Custom logo option available

HOMESTEADER DELUXE PACKAGE

CABLE SUPPORT MANAGEMENT SYSTEM

Rugged Ridge Engine Transmission Skid Plate JK

Super Tube Spiral Slide Instructions

Austin Standing Seam Awning Assembly and Installation Instructions. Assembly Instructions

WPS crew Doors Installation instructions

GANTRY SYSTEM ASSEMBLY MANUAL

5-axis clamping system compact

Installation Manual. Arc Chamber

Patented Rail-Free Mounting System for Composition/Asphalt Shingle Roofs

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Hearts Bed With 4 Poster Frame

10 x 10 Flat Top Two Tone Pergola

Installation Instructions for Solar Snow Pad (SSP-T-3)

MODEL 9301E. Extra Heavy Duty Full Extension Drawer Slide Up to 600-lb. [272 kg.] Load Rating Optional Accessory Platform Brackets*

INSTALLATION INSTRUCTIONS GRILLE GUARD CHEVY TAHOE / AVALANCHE 1500/ SUBURBAN 1500 PART # /502795

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

8.5 Ton Assembly Instructions

BIFOLD FUTON FRAME TRINITY ARM. Seat Rails and Slats x 1. *Note: Use 4pc of 100mm Bolts and 4pc of 60mm Bolts to attach the arms to the Stretchers.

Cable trays Assembling instruction

Warnings. Description. Prior to Installation Tools Needed

INSTALLATION INSTRUCTIONS PART#:17A096400MSS\17A096400MA MODULAR GRILL GUARD FOR TOYOTA TACOMA 05-09

Transcription:

straight length to straight length couplers ouplers are used for joining together straight lengths in the medium duty (Topaz), heavy duty (Sapphire) and extra heavy duty (Emerald) ranges Fittings in these ranges have integral couplers. See p. 44 for more information Even when ladders are cut to length, the in the coupler will always align with the in the ladder side rail Supplied in pairs with the appropriate quantity of fasteners ssembly Slide the couplers under the return flanges of one ladder side rail and loosely fit a single fastener to each coupler to hold it in place Slide the second ladder over both couplers, adjust each coupler position to align the with the side rail and secure with all fasteners (Topaz) ZF olts should be inserted through the side rail first For location of coupler and position of fasteners, see below Fastener positioning (Topaz) Supplied in pairs, with fasteners (4 per coupler) (Sapphire) PF When bolting to cut ends adjust coupler to ensure 4 bolts can be inserted When connecting straight lengths to straight lengths even when ladder is cut to length, the in the coupler will always align with in the ladder side rail (Sapphire) and extra heavy duty (Emerald) Supplied in pairs, with fasteners (8 per coupler) When bolting to cut ends adjust coupler to ensure 8 bolts can be inserted When connecting straight lengths to straight lengths even when ladder is cut to length, the in the coupler will always align with in the ladder side rail at. Nos. ZF PF EF per coupler 4 8 8 (Emerald) EF Joggles are formed in the bottom of P and E couplers to allow easy installation of ladder cut lengths When connecting straight lengths to fittings, use fastener sets, see p. 44 For additional types of straight length to straight length couplers and fasteners, see p. 39-42 (deep galvanised) ll dimensions (mm) are nominal 38

ssembly (continued) Fasteners (included) Side rail oupler M x 20 coachbolt M flange nut Setting (M): 40Nm For ladders with G, and E finishes, fasteners are high tensile Grade 8.8 hot dip galvanised Grade 470 n alternative material for fasteners may be required depending on the imensions and weights (Topaz) ZF (Sapphire) PF 75 Six 37 x 13 75 Six 37 x 13 (Emerald) EF 75 Six 37 x 13 at. Nos. (kg) ZF 220 13 95 1 5 0 6 PF 220 13 119 2 0 1 0 EF 220 13 144 2 0 1 2 s ll weights given are in kilograms (kg) and are for a pair of couplers in hot dip galvanised G finish To obtain the appropriate component weight in other finishes, multiply the given weight by the following factors : eep galvanised () x 1 07 ll dimensions (mm) are nominal 39

flexible expansion couplers Flexible expansion couplers can be used to : a. provide a semi-flexible joint where ladder runs span separate structures between which some relative movement is possible b. provide compensation for changes in the length of a straight cable ladder run due to temperature variations Supplied in pairs with fasteners Normal installation (Sapphire) PEF (ZEF and EEF similar) ssembly (continued) Fasteners (included) Side rail oupler M x 20 coachbolt M flange nut Setting (M): 40Nm For ladders with G, and E finishes, fasteners are high tensile Grade 8.8 hot dip galvanised Grade 470 n alternative material for fasteners may be required depending on the at. Nos. ZEF PEF EEF per coupler (1) 4 8 8 Stiffened installation (Sapphire) PEF (ZEF and EEF similar) (1) for normal installation, or per pair (each side) for stiffened installation imensions and weights (Topaz) ZEF (Sapphire) PEF Flexible expansion couplers should normally be installed with the ridges facing outward, away from the bed of the ladder If necessary, the stiffness of each joint can be increased by mounting pairs of couplers back-to-back (with one set of ridges facing inwards and the other set facing outwards as shown above) on either side of the cable ladder. The allowance for differential movement remains unchanged (see below) Rigid support for the cable ladder should be provided on both sides adjacent to each joint (Emerald) EEF ssembly Each joint formed by flexible expansion couplers provides for up to mm of linear movement between the two adjacent ladders To calculate the ideal distance between flexible expansion coupler installations use the formula : L = K S T Where : L = distance between flexible expansion couplers, in metres K S = 909 for mild steel, 625 for stainless steel T = temperature range (in ) for which allowance is to be made oefficients of linear expansion : mild steel = 11 x -6 / stainless steel = 16 x -6 / (deep galvanised) at. Nos. (kg) ZEF 320 84 113 0 1 0 0 6 PEF 317 115 111 5 1 5 1 1 EEF 317 138 111 5 1 5 1 4 s ll weights given are in kilograms (kg) and are for a pair of couplers in hot dip galvanised G finish To obtain the appropriate component weight in other finishes, multiply the given weight by the following factors : eep galvanised () x 1 07 ll dimensions (mm) are nominal 40

bendable connectors endable connectors can be used for : a. fabricating fittings on site from cut lengths of cable ladder b. reducing width of a run to the next size down when a properly manufactured reducer is not available c. correcting minor mis-alignment problems d. coupling lengths of ladder to form articulated bends endable connectors are supplied in pairs with fasteners (Sapphire) PHF (ZHF and EHF similar) ending the run Re-aligning the run ssembly Fasteners (included) at. Nos. ZHF PHF EHF per connector 4 8 8 per additional connector 2 4 4 Side rail oupler M x 20 coachbolt M flange nut Setting (M): 40Nm For ladders with G, and E finishes, fasteners are high tensile Grade 8.8 hot dip galvanised Grade 470 n alternative material for fasteners may be required depending on the imensions and weights (Topaz) ZHF (Sapphire) PHF Reducing width of run (Emerald) EHF Forming a long articulated bend Rigid support for the cable ladder should be provided on both sides adjacent to each joint (deep galvanised) at. Nos. (kg) ZHF 2 84 1 5 0 5 PHF 2 115 1 5 0 7 EHF 2 140 1 5 0 8 s ll weights given are in kilograms (kg) and are for a pair of couplers in hot dip galvanised G finish To obtain the appropriate component weight in other finishes, multiply the given weight by the following factors : eep galvanised () x 1 07 ll dimensions (mm) are nominal 41

vertical hinged connectors Vertical hinged connectors can be used for : a. fabricating fittings on site from cut lengths of cable ladder b. solving minor vertical mis-alignment problems c. coupling articulated risers to adjacent ladders Supplied in sets comprising four plates and fasteners (Sapphire) PVF (ZVF and EVF similar) ssembly Vertical hinged connectors can either be connected together to form pre-set angles or pre-assembled for adjustment in situ ssembly to a pre-set angle 1. identify the correct outer fixing holes for the required pre-set angle (see table and illustration below) 2. insert a fastener through the identified holes in both plates and fit a locking washer and nut but do not fully tighten o not insert fasteners through the centre hole first, this makes identification of the outer holes very difficult 3. move the two connectors to align the centre holes. Insert a fastener through the holes and fit a locking washer and nut but do not fully tighten 4. insert a third fastener through a slot in one connector and an aligning hole in the other. Fit a locking washer and nut 5. tighten all fasteners ssembly (continued) onnector to connector fasteners (included) ZVF PVF, EVF M6 x 16 setscrews M6 washer M6 shakeproof washer onnector E M6 nut F M x 20 setscrews G M form washer H Flange nut E F G H Setting (M): 40Nm For ladders with G and finishes, fasteners are high tensile Grade 8.8 Grade 470 For ladders with E finish, the fasteners are Grade 8.8 hot dip galvanised n alternative material for fasteners may be required depending on the at. Nos. ZVF PVF EVF per connector to ladder 2 x M 4 x M 4 x M per connector to connector 3 x M6 3 x M 3 x M imensions and weights (Topaz) ZVF (Sapphire) PVF at. Nos. 15 18 22 5 30 45 ZVF, PVF, EVF G : : F E : : G F : ZVF, PVF, EVF E F G H O G F E O H E (Emerald) EVF Four 37 x 13 E Pre-assembly for adjustment in-situ 1. insert a fastener through the outer hole of both connectors. Fit a locking washer and nut and tighten sufficiently to hold the assembly together while it is carried to the installation position 2. fit the assembly to the installed ladders 3. insert a second fastener through the slot in one connector and an aligning hole and fit a locking washer and nut 4. if possible, insert a third fastener through either the alternate slot and an aligning hole, or two aligning holes. Fit a locking washer and nut 5. tighten all fasteners onnector to ladder fasteners (included) Side rail onnector M x 20 coachbolt Flange nut (deep galvanised) E at. Nos. E (kg) ZVF 212 80 172 0 0 1 5 0 8 PVF 2 115 192 5 71 0 2 0 1 5 EVF 270 140 201 0 79 5 2 0 2 0 s ll weights given are in kilograms (kg) and are for a set of four plates in hot dip galvanised G finish To obtain the appropriate component weight in other finishes, multiply the given weight by the following factors : eep galvanised () x 1 07 ll dimensions (mm) are nominal rticulated risers : see p. 85-86 42

Swifts cable ladder systems pre-fabrication of cable ladder runs Swifts cable ladder systems identification and recognition fittings To assist in the installation of a complete cable ladder run following a centre-line drawing (usually generated), the technical fitting pages for each fitting contain, X, and length dimensions where appropriate, and also diagrams to explain the dimensions The dimensions help to ensure that fittings are correctly positioned in line with the drawing and make it possible to accurately calculate the installed length of intermediate straight sections. This allows the sections to be cut to length and pre-assembled, making installation in elevated or restricted areas much simpler simple layout is illustrated at the bottom of the page to show how available dimensions can be used dimension The dimension is given for bends and risers in cable ladder ranges. It is the length of the centre-line from each end of the fitting to the point at which the centre-lines intersect, as shown below end (typical) X Under site conditions it is often difficult to distinguish between different fittings, particularly bends and risers of varying widths and radii. To assist identification, key dimension values are given on each relevant technical fitting page to provide a simple means of differentiating between similar fittings Width The available widths, or combinations of widths for all fittings are always listed and are a necessity for positive identification i dimension This dimension identifies those fittings in the cable ladder ranges which have curved sections or change the direction of the run through varying angles. It is the measurement across the inner curve of the fitting, as shown below, and is a constant for each available radius option end 80 80 Radius i Width Riser Riser (typical) i X X and dimensions X and dimensions are given for all cable ladder fittings other than reducers and straight lengths (see examples shown) X, X Equal tee, unequal tee, crosspiece X Length i X, and dimensions For cable ladder fittings without an I dimension, the X, and dimensions (where applicable) can be used. These are listed in each relevant technical fitting page and explained on the following page ll dimensions (mm) are nominal Fittings : see p. 46-73 43

integral fitting couplers and fitting to fitting couplers Integral fitting couplers ll ladder fittings have integral couplers For straight length to fitting connections, see below For fitting to fitting connections, see opposite ssembly For straight length to fitting connections, use fasteners sets, see table below for number of fasteners required per fitting type For fitting to fitting couplers, see opposite Fastener positioning (Topaz) Fitting to fitting couplers Fitting to fitting couplers are used for joining together cable ladder fittings (bends, tees, risers etc) in the medium duty (Topaz), heavy duty (Sapphire) and extra heavy duty (Emerald) ranges. Fittings in these ranges have integral couplers. See opposite for more information. Supplied in pairs with the appropriate quantity of fasteners (Topaz) ZFF (Sapphire) and extra heavy duty (Emerald) Fastener sets comprise of each of the following : M coach bolt and flange nut Number of fasteners required per fitting type Topaz Sapphire and Emerald Flat bends 8 16 Inside / outside risers 8 16 Reducers 8 16 Tees 12 24 4 way crosspieces 16 32 Fastener detail and finishes, see opposite imensions (Topaz) end detail 5 90 20 7 30 49 23 19 (Sapphire) PFF (Emerald) EFF hamfer 7 x 45 2 holes 11 X 11 4 37 X 13 2 Ø 7 5 earth bonding holes (Sapphire) end detail 5 7 30 49 25 19 115 20 hamfer 7 x 45 2 Ø 7 5 earth 4 37 x 13 bonding holes 4 holes 11 x 11 (Emerald) end detail 5 5 139 32 7 30 49 hamfer 7 x 45 25 19 4 37 x 13 2 holes 11 x 11 62 5 2 Ø 7 5 earth onding holes (deep galvanised) ll dimensions (mm) are nominal Fittings : see p. 46-73 44

ssembly Slide the couplers under the return flanges of one ladder side rail and loosely fit a single fastener to each coupler to hold it in place Slide the second ladder over both couplers, adjust each coupler position to align the with the side rail and secure with all fasteners imensions and weights (Topaz) ZFF 225 22 19 5 pitches of 37 5 25 (Sapphire) PFF Z fitting coupler 12 22 x 11 225 22 19 5 pitches of 37 5 For location of coupler and position of fasteners, see below Fastener positioning (Topaz) Supplied in pairs, with fasteners (4 per coupler) P fitting coupler 12 22 x 11 (Emerald) EFF 225 22 19 5 pitches of 37 5 25 (Sapphire) and extra heavy duty (Emerald) Supplied in pairs, with fasteners (8 per coupler) 37 5 E fitting coupler 12 22 x 11 at. Nos. ZFF PFF EFF per coupler 4 8 8 When connecting straight lengths to fittings, use fastener sets, see opposite Fasteners (included) Side rail oupler M x 20 coachbolt M flange nut at. Nos. (kg) ZFF 0 6 PFF 1 1 EFF 1 4 s ll weights given are in kilograms (kg) and are for a pair of couplers in hot dip galvanised G finish To obtain the appropriate component weight in other finishes, multiply the given weight by the following factors : eep galvanised () x 1 07 Setting (M): 40Nm For ladders with G, and E finishes, fasteners are high tensile Grade 8.8 hot dip galvanised Grade 470 n alternative material for fasteners may be required depending on the 45