A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

Similar documents
DESCRIPTION NOTE. Power Supply MODEL 2200A PM

DESCRIPTION NOTE MODEL 2200VM

FTT-10A Free Topology Twisted Pair Transceiver Model 50051

DUAL 4-20 MA NETWORK BRIDGE. Voltage. Regulator. Neuron CPU. Ohm Sense Resistor. Model 1400A Block

Excel 15 S7760A COMMAND DISPLAY

DESCRIPTION MODEL 1450 NOTE

TD_485 Transceiver Modules Application Guide 2017

SMX Transceivers Models 77010, 77030, 77040, 77050, and 77162

Micro Thermo Standard Wiring Guide

MNL-5Rxx. Application. Model Chart. TAC I/A Series MicroNet MN 50 Controller Installation Instructions

Excel 10 W7761A Remote Input/Output Device

TD_CAN Transceiver Modules Application Guide 2017

Hardware Manual. PCD3.F240/PCD2.F2400 LON interface module for TP/FT-10 channel. Hardware Manual PCD3.F240/PCD2.F2400, LON interface module

NEUROLOGIC RESEARCH CORPORATION

LX Scheduler. Installation Instructions LX-SCHEDL-0. Mounting. Applications. North American Emissions Compliance. Installation

LONWORKS LPI-10 Link Power Interface Module User s Guide

Connecting a Neuron 5000 Processor to an External Transceiver

The I-2532 CAN to Fiber Converter

Din-Mon Smart Meter. Advanced kwh/demand Meters with Communication INSTALLATION INSTRUCTIONS

IMC-316P Hardware Manual for model IMC-316P-X-D

The i-7531 CAN Repeater

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

SFIBER Fibre-optic Option Card for Lon Star Coupler RER 111. Technical Reference Manual

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

RS-485 HUB GT for Profibus, Sinec L2, Bitbus, etc. Article No S-485-HUBGT-230-xx-x. Operation and Installation Manual

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

Dual Protocol Transceivers Ease the Design of Industrial Interfaces

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

M-Bus Master MultiPort 250L Installation and User Guide

PROFIBUS HUB REPEATER

Electronic Circuit Breaker with reset input ESS20-1..

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

Excel 10 W7751B,D,F VAV Controllers

Page 1 of Release 2.2. LON Transponder Reader. Technical Reports

Choosing the correct Furse ESP Lightning Barrier for your application

Active CCTV Receiver Balun Installation Guide

Wireless 900 MHz Receiver

AMC mA Positioner

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS

ZCS485 User s Manual. Version ZYPEX, Inc.

n FRONT PANEL CONFIGURATIONS

WattNode Plus. for LONWORKS Installation and Operation Manual. Continental Control Systems LLC

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Contents. Warranty and Disclaimer 2

Excel 800 / Excel Web II CABLE SPECIFICATIONS

269 Troubleshooting Guide 11/4/98 1

I-2533CS series User Manual

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

Inductive Loop Detector

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

IO-DIM4 4-Channel, Digital to Analogue Converters

Short form User Manual

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Installation Instructions

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

8V General information. 2 Order data 8V

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

ALX-SSB 5 Band Filter Assembly Manual 19 November 2018

TECHNICAL PRODUCT DATASHEET

INSTRUCTION LEAFLET IL17553B IQ UNIVERSAL POWER SENTINEL TM INSTALLATION INSTRUCTIONS FOR THE IQ UNIVERSAL POWER SENTINEL TM INTERNAL CT

- Wiring Brochure Universal Reset Module 423e

Model PRESET 8 Installation and Operations Manual

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

CEC VIBRATION TRANSMITTER

WattNode Plus. for LONWORKS - Option BI Installation and Operation Manual. Continental Control Systems LLC

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Arc Sensor User Manual

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

SURFACE VEHICLE RECOMMENDED PRACTICE

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web: -

Lonbox PIO4014 Users Manual

Blue Point Engineering

Installation & Operation Manual

Electronic Circuit Breaker ESS1 for System SVS1

Wireless Analog Output Modules

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

H7625A, H7635A, H7626A, H7636A Series 2000 Humidity/Temperature Sensors

Transmission Line Drivers and Receivers for TIA/EIA Standards RS-422 and RS-423

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

INSTALLATION & OPERATION MANUAL

Best Practices Guide Polycom SoundStructure and HDX Microphones

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

Dual Band Filter Assembly Manual

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Integrity Instruments

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

Kaskode One Phono Preamplifier Owner s Manual

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

M2 Antenna Systems, Inc. Model No: S3 Sequencer. Operating Instructions

Rev RF Service Tool Operator s Guide

Transcription:

FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers configured as repeaters. - All wiring is to removable terminal blocks for ease of service. - Polarity insensitive 12-36VDC or 12-26VAC wide input voltage range and optionally very wide AC/DC input voltage range of 12-72 VDC or 12-50 VAC. (New Feature) - Input power has over current and transient voltage suppression. - Termination for bus and free topology. - 3.5 mm network jack for local installation tool connection. - Communication and power indicators to assist in field diagnostics. - DIN Rail mount enclosure is only 36 mm (1.42 ) W x 90 mm (3.54 ) L x 58 mm (2.28 ) H DESCRIPTION Each Model 110A is a two-channel physical layer repeater for FTT-10 LonWorks networks. Data received on one channel is reconditioned and re-transmitted on the other channel. Each Model 110A effectively doubles the wiring distance and the number of nodes that can be placed on the network. On-board jumpers allow each channel to be terminated independently for bus or free topology. A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. Three LED s provide diagnostic information for troubleshooting. A green LED indicates when power is applied. Two red LED s indicate when data is being received on each of the two local channels. The Model 110A operates from a wide range of low voltage AC or DC power sources allowing it to be easily added to existing systems. The power input has transient voltage suppression as well as over current protection using a self-resetting fuse. This provides protection to the unit under most fault conditions. The Model 110A is a drop in replacement to our Model 110 product. A new feature in the Model 110A allows multiple repeaters to be daisy chained together to create multi-segment repeaters. This is accomplished via a short jumper cable between units. Data received on one network segment is transmitted on all other network segments. For example, assume three Model 110As are daisy chained together. This equates to six total network segments since each repeater has two. Data received on any one network segment is reconditioned and sent on the other five network segments. This ability allows the user to create a field expandable multi-segment repeater from two to ten channels using a single product. 1

Note, the daisy chain feature of the Model 110A is not on the network side but actually takes place on a separate daisy chain bus between repeaters. This has several advantages. One, there is minimal delay between the received signal and the repeated signal. Even with a ten-segment repeater (5 Model 110As), the delay is equivalent to a single repeater. Two, each network segment is completely isolated from all other network segments. A short on one segment will only affect that segment and not the others. NETWORK OVERVIEW The TP/FT-10 network is designed to support free topology wiring, and will accommodate bus, star, loop, or any combination of these topologies. Network devices using FTT-10A transceivers can be located at any point along the network wiring. This capability simplifies system installation and makes it easy to add nodes should the network need to be expanded. Figures 1 through 5 present five different network topologies. Termination Figure 1 Single Terminated Bus Topology Termination Figure 2 Dual Terminated Bus Topology 2

Figure 3 Star Topology Terminatio Figure 4 Loop Topology Figure 5 Mixed Topology In the event that the limits on the number of transceivers or total wire distance are exceeded, then the Model FTT-10 Physical Layer Repeater can be added to interconnect two segments and double the overall system capability. 3

SYSTEM PERFORMANCE AND CABLE SELECTION TP/FT-10 network system and transmission specifications are outlined on the following pages. Both of these specifications must be met to ensure proper operation. The system designer may choose a variety of cables, depending on cost, availability, and performance. Performance may vary with cable type. The transmission specification depends on such factors as resistance, mutual capacitance, and the velocity of propagation. Currently, Echelon has documented system performance on the cable types shown in table 1. Table 1 Cable Types and Typical Parameters Cable Type Wire dia. / AWG R loop Ω/km CnF/k m Belden 85102 single twisted pair stranded 19/29 unshielded 150 o C 1.2mm/16 28 56 62 Belden 8471 single twisted pair stranded 19/29 unshielded 150 o C 1.3mm/a6 28 72 55 Level IV 22 awg twisted pair typically solid and unshielded 0.65 mm/22 106 49 67 JY (ST) Y 2x2x0.8 4 wire helical twist solid shielded 0.8 mm/20.4 73 98 41 Tia568 Category 5 24 awg twisted pair 0.51 mm/24 168 46 58 Vprop % of c If a shielded cable is used, the shield should be connected to earth ground via a single 470K Ω, 1/4 Watt, 10%, metal film resistor to prevent static charge build-up. Note that the following specifications are for one network segment. Multiple segments may be combined using repeaters as described in the network overview section to increase the number of nodes and distance. SYSTEM SPECIFICATIONS Up to 64 FTT-10/FTT-10A transceivers are allowed per network segment. LPT-10 transceivers may be used on network segments with FTT-10/FTT-10A transceivers, but are subject to additional constraints, particularly on distance. See the LPT-10 User's Guide for more information. The average temperature of the wire must not exceed +55 C, although individual segments of wire may be as hot as +85 C. TRANSMISSION SPECIFICATIONS Table 2 Dual Terminated Bus Topology Specifications Cable Type Maximum bus length Units Belden 85102 2700 meters Belden 8471 2700 meters Level IV 22 awg 1400 meters JY (St) Y 2x2x0.8 900 meters TIA Category 5 900 meters 4

Table 3 Free Topology Specifications Cable Type Maximum node-to-node distance Maximum total wire length Units Belden 85102 500 500 meters Belden 8471 400 500 meters Level IV 22 awg 400 500 meters JY (St) Y 2x2x0.8 320 500 meters TIA Category 5 250 450 meters The free topology transmission specification includes two components, which must both be met for proper system operation. The distance from each transceiver to all other transceivers and to the termination (including the LPI-10 termination, if used) must not exceed the maximum node-to-node distance. If multiple paths exist, e.g., a loop topology, then the longest path should be used for the calculations. The maximum total wire length is the total amount of wire connected per segment. WIRING AND INSTALLATION All wiring is done via two sets of removable terminal blocks. The top terminal block has two positions and supplies power to the unit. 12-36 VDC or 9-26 VAC can be used. The terminals are polarity insensitive. Optionally, the Model 110 is also available with a much wider input voltage range of 12-72 VDC or 12-50 VAC. See ordering information section. Daisy Chain Connectors Vin B Vin A Network Jack Network 1 Network 2 The bottom terminal block has four positions. Two terminals for each network. The terminals for the first network channel are labeled NET 1. The terminals for the second network channel are labeled NET 2. The network wiring is polarity insensitive. The network jack provides an access point for a network management tool. It can be used for monitoring or configuration without the disturbing the network wiring. 5

JP2 Pins are 1-2-3 JP1 Pins are 3-2-1 JUMPERS FOR MODEL 110A FTT-10 REPEATER JUMPER FUNCTION FREE TOPOLOGY (DEFAULT SHOWN) BUS TOPOLOGY NO JP1 Side 1 Termination 1-2 2-3 Off JP2 Side 2 Termination 1-2 2-3 Off MULTI-SEGMENT DAISY CHAINING Up to 5 Model 110A Repeaters can be daisy chained to form a ten-channel repeater. To operate properly in multi-segment mode the user must observe the following installation requirements: All repeaters must be placed next to each other and powered from the same power source. All units that are daisy chained together must be powered. A unit that is connected on the daisy chain bus but not powered will cause other units to fail. There is no physical damage but the units will note operate properly. The jumper cable is polarity sensitive and the jumper cable is keyed and should only plug onto the header in the proper orientation. If it feels that it is not going on correctly, chances are it is reversed. Each segment should be properly terminated. Each Model 110A is delivered with a short jumper cable attached to the two daisy chain jumper headers. This is simply a convenient place to store it. It is not needed for proper operation if used as a standalone two-channel repeater. The two daisy chain headers provide identical connections. Two headers are needed to daisy chain between more than two units. 6

MOUNTING OPTIONS The Model 110A is housed in a very compact DIN rail mount enclosure that is only 36 mm (1.42 ) W x 90 mm (3.54 ) L x 58 mm (2.28 ) H. The enclosure snaps onto an industry standard 35 mm DIN rail. The DIN rail and Model 110A can be inside a weatherproof box for best protection. Alternatively, the DIN rail and Model 110A can be wall mounted if it is in a clean indoor environment. SPECIFICATION Operating Environment 0 to 80C, 0-90% RH non-condensing Input Power - 12-36 VDC or 9 to 26 VAC @ 30 ma typical. Polarity insensitive wiring. 0110A-00-12-72 VDC or 12 to 50 VAC Optional. 15 ma typical at 12 VDC and 4 Network Transceiver Type Network Termination Multi-Segment Operation External Dimension Enclosure Type Enclosure Material Protection ma typical at 72 VDC Two Echelon FTT-10A transceivers at 78 kbps. DC blocking capacitors for Link Power network are installed. 0110A-01 Separate jumpers for each channel support free and bus topology termination. Max of 5 repeaters can be daisy chained to construct a 10-channel repeater hub. 36 mm (1.42 ) W x 90 mm (3.54 ) L x 58 mm (2.28 ) H DIN rail mount to 35 mm rail Grey frame retardant Noryl UL94_V0 Input power is fused and transient voltage protected. Fuse automatically resets when fault is removed. ORDERING INFORMATION 0110A-00 Model 110A FTT-10 Physical Layer Repeater. 12-36 VDC/9 to 26 VAC 0110A-01 Model 110A FTT-10 Physical Layer Repeater. 12-72 VDC/12 to 50 VAC Echelon, LON, LonWorks, Neuron, 3120, 3150, LONMARK are trademarks of Echelon Corporation.. 7