TECHNICAL MANUAL - CONSTRUCTION AND INSTALLATION

Similar documents
TECHNICAL MANUAL - CONSTRUCTION AND INSTALLATION

Wooden Frame Type Instruction Manual

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Pet Door Panel Installation Manual

Product data sheet R106FS POWERMATIC FREE SWING DOOR CLOSER

LEGENDS RETRACTABLE DOOR SCREENS

XL-GC03 Sliding Door Lock Installation Manual PAT XL-GC06 Sliding Door Hanger Installation Manual XL-GC08 Sliding Door Lock Guide Installation Manual

How To Measure Your Finished Opening

INSTALLATION INSTRUCTIONS

Assembly Instructions

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

NEPAL Installation procedure

Mounting Instructions Item No.: xxx

LEGENDS RETRACTABLE DOOR SCREENS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

MM750 Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

RangerWare Fiberglass Door System Installation Instructions P/N

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

INSTALLATION INSTRUCTIONS

Installation Instructions

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Installation Instructions For The 8850FL Series Mortise eboss

Installation Instructions. Oakmont Folding Doors

INSTALLATION INSTRUCTIONS

ICU TRACKLESS SLIDING DOOR

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Household Appliances. Over-the-Range Microwave. Installation Instructions. For Models: HMV9302, HMV9305, HMV9306, HMV9307

DC3210. Recommended Closer Size

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

Please read these instructions before use and keep for future reference

Aluminum Frame Type Instruction Manual

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

INSTALLATION INSTRUCTION

Pocket Door Kit PD1 / PD2 Installation Instructions. Kit Contents.

Colonial Classic Bar

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE


INSTALLATION INSTRUCTIONS

FOLDING DOOR INSTRUCTIONS

Pedestal Desk IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratches

Sliding Door Kit

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)

Installing Your Electronic Deadbolt

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Linvisibile Concealed Sliding door Manual version

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

PFD-22 Top OHC Patch Fitting & PFD-10 Bottom Patch Fitting Installation Instructions

1530(F) Mortise Exit Devices Installation Instructions

SYSTEM 42 SCREEN CASSETTE WITH 30mm SIDE RAIL

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Step by Step Installation Instructions. Poly Shutters. Customer Service or visit us online at smithandnoble.com

Closet System Installation Manual

Barnside Pantry IMPORTANT NOTE Carefully remove all the parts from the carton and put them individually on a soft cloth to prevent scratch

Custom Wood Frame Overlay for Glass Doors Installation Instructions

FURNITURE HARDWARE & ACCESSORIES - PART 3 : LEVELLERS AND HANGERS

Shetland Stalls Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Oxford Stalls Installation Instructions

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

ASOLA - THETA ISTRUZIONI DI MONTAGGIO FITTING INSTRUCTIONS INSTRUCTIONS DE MONTAGE INSTRUCCIONES DE MONTAJE MONTAGEANLEITUNG. IMPBAT Rev.

IDP Entry-Fit Steel Door Frames. Installation Instructions K2A and NK2A Series Frames

Portofino Installation Guide

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

ASSEMBLY GB. Mod. FUSION. Code MD.K.100 Rev 0 Edition 10/06. advanced mobular stair system

Heavy Wall Applied Stop Tube Frame and Door Installation

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Preference Collection and Treatment Console INSTALLATION GUIDE

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

ICU TRACK SLIDING DOOR

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

HENDERSON. Securefold Bottom Rolling. Fitting Instructions For Bottom Rolling External Doors with Morticed hinges SYSTEM CAPACITY.

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Door: product description. Technical features and details. Available sizes and models MADE IN ITALY.

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

INSTALLATION INSTRUCTIONS

FURNITURE HARDWARE & ACCESSORIES - PART 2 : SHELF SUPPORT AND SHELVING SYSTEMS

C-Series & S-Series Classic Frame with Transom (Single or Pair)

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

INSTALLATION INSTRUCTIONS

Thermally Broken Framing and Door Installation

PMT-L31 (for Low Ceilings) PMT-H35 (for High Ceilings)

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

DOOR KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 6. Verify accessory fitment at Polaris.com.

ESA-300 Full Breakout

2300 BI-FOLD INSTALLATION GUIDE

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

L INVISIBILE CONCEALED SLIDING SYSTEM

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

aluminium profile system

Transcription:

ERGON T.E. LIVING SLIM TECHNICAL MANUAL - CONSTRUCTION AND INSTALLATION Swinging-sliding door with connecting rod on frame JAMB THICKNESS 30/40 mm CELEGON S.r.l. - Via G. Galilei, 6-30035 Mirano (Venezia) - T +39 (0)41 5728404 - F +39 (0)41 5728522 www.ergon.eu - info@ergon.eu

INDEX 1. INTRODUCTION... 3 2. DESCRIPTION... 4 2.1 Exploded hardware diagram... 4 2.2 Single door horizontal dimensional drawing... 5 2.3 Double door horizontal dimensional drawing... 6 2.4 Double door horizontal dimensional drawing... 7 2.5 Vertical dimension drawing... 8 2.6 Management of wall thicknesses... 9 2.7 Specific door processing... 10 2.8 Exploded frame diagram (centred door)... 11 2.9 Construction details of the vertical frame arms side... 12 2.10 Construction details of the vertical frame lock side... 13 2.11 Construction details of the upper crosspiece... 14 2.12 Track adjustment to the width of the door to be achieved... 15 2.13 Shortenable connecting rod kit... 16 2.14 Track union kit for double door with ERGON LIVING system... 17 2.15 Magnetic striker plate for Push&Go EVO...19 3. ASSEMBLY... 20 3.1 Installation of hardware on the door leaf... 20 3.2 Connecting rod assembly with upper and lower arm... 21 3.3 Assembly of hinge side jamb to the connecting rod... 22 3.4 Assembly of frame and track... 23 3.5 Installation of complete jamb... 24 3.6 Door leaf installation... 25 3.7 Door leaf and frame adjustment... 26 3.8 Soft Opening damper installation (Optional)... 27 3.9 Mounting frames and track cover profiles... 29 The company reserves the right to make, at any time, without prior notice, all the technical and aesthetic changes deemed necessary to improve the quality and functionality of its products. All contents of this manual are copyright. The reproduction, even partial, of texts and technical drawings, without the prior written consent of the company Celegon s.r.l. is prohibited. Any abuse will be prosecuted according to law. All designs in this manual are reserved by law: copying and disclosure are forbidden without permission. 2

1. INTRODUCTION The Ergon Living T.E. SLIM system retains the tried and tested features of T.E. version: ERGON LIVING T.E. SLIM - Rotation rod within the frame; - Door weight limit 70 kg; - Minimum door thickness 35 mm; - Possibility of applying the Soft Opening damper; - Available in silver and black finishes; - Two different arm sizes: BASE particularly suitable for LFM (Wall opening width) from 800 to 1000 mm; SMALL particularly suitable for LFM (Wall opening width) from 610 to 800 mm; Differences from the T.E. version: - the connecting rod does not require the aluminium upright, but is simply held in the guide by a small plastic component; - the T.E. SLIM version allows the use of a flat frame of the thickness 30 to 40 mm; - the use of doors in standard sizes with a false frame of standard size (e.g.: door L = 815 mm with wall opening width L = 900 mm) using a 30 mm thickness frame; - we recommend the use of a magnetic lock. Depending on the specific needs, with the T.E. SLIM hardware the door can be constructed in such a way that, compared to the wall thickness, the door can assume any position. There follow two limit positions, making use of terminologies which are then used in this manual: 1. centred door where the door is positioned at the centre of the wall 2. oriented door where the door is positioned close to one of the two edges of the wall The Ergon Living T.E. SLIM system is offered in various sizes of standard widths and heights. It is also possible obtain intermediate measures in width by shortening the track and the track cover (see 2.12 Track adjustment to the width of the door to be achieved ), in height by purchasing the appropriate shortenable rod kit (see 2.13 Shortenable connecting rod kit ), or requesting the rod in a special measurement. SWING DOORS WITH ONE DIRECTION OF OPENING The Ergon kits for swing doors with one-way opening are the same as those used for doors with two-way opening; this is possible by simply creating the hinges in the vertical sides of the door. Here below is an example: with two-way opening 5,5 mm 30 3 Height A + 2,5 see paragraph 2.7 Specific door processing Caution: The door and frame hinges are mirrored. It is also possible to construct doors without the hinge. 40 3 3

2. DESCRIPTION 2.1 Exploded hardware diagram 127 230 375 100 280 267 317 240 250 327 207 130 267 117 335 220 147 Component present in the track kit Component present in the rod kit 307 197 207 327 267 167 187 210 157 175 210 List of components Ref. Q.ty Description 100 1 Track 117 1 Upper arm 127 1 Upper bracket arm side 130 1 Upper bracket lock side 147 1 Track cover profile 157 1 Upper plate with trolley 167 1 Connecting rod 175 1 Lower plate 187 1 Lower arm 197 1 Lower bracket 207 4 Screws TCEI M 3x6 210 5 Screws TSPCR ø 4x40 220 2 Screws TSPCR ø 3x10 230 1 Screws TSPEI M 5x12 240 2 Track cover caps 250 2 Track cover fixing insert 267 14 Screws TSPCR ø 3x25 280 1 Hexagonal screwdriver 2.5 mm 307 1 Rod guide 317 1 Upper pivot 327 2 Rod rotation bush 335 1 Upper arm fixing pin 375 1 Hexagonal key 2.5 mm 4

2.2 Single door horizontal dimensional drawing SMALL BASE Dimensional example LFM (900) ES (883,5) LS (823,5) The door can be positioned oriented with respect to the thickness of the wall, respecting the limit shown in the diagram below. 28 mm 30 30 5,5 LA (815) 3 Oriented door For the management of wall thicknesses see 2.6 Management of wall thicknesses. min. 35 45 9 QV (425) QF (390) (fixed height) (Variable dimension depending on door width) LA (815) LP (770) 30 ATTENTION: On door with reduced widths the handle may collide with the jamb. Pay attention to the dimension of the handle, door leaf and wall thickness. The values given in this table refer to a door with frame thickness 30 mm and door thickness 45 mm; in case of using a frame of thickness 40 mm the values of LP, LA, LS and QV decrease by 20 mm. BASE SMALL WIDTH DIMENSIONS LFM LP LA QF QV 610 480 525 290 235 650 520 565 290 275 Minimum size for Soft Opening arm SMALL 700 570 615 390 290 225 325 750 620 665 390 290 275 375 Minimum size for Soft Opening arm BASE 800 670 715 390 290 325 425 LFM = Wall opening width LP = Passage dimension (LFM - 130) LA = Door width (LFM - 85) LS = Jamb opening (LFM - 76,5) ES = Exterior jambs (LFM - 16,5) QF = Fixed dimension arms side QV = Variable dimension handle side 850 720 765 390 375 900 770 815 390 425 950 820 865 390 475 1000 870 915 390 525 = Standard Available sizes = Some examples of measurements obtainable by shortening the track, it is also possible to obtain other intermediate measurements For other special measurements ask Celegon s.r.l. for feasibility 5

2.3 Double door horizontal dimensional drawing SMALL BASE ERGON door leaf and rabbet door Dimensional example LFMD (1200) ESD (1180) LSD (1120) 30 30 5,5 min. 35 45 9 QV (425) QF (390) (quota fissa) (quota variabile in base alla larghezza dell anta) LA1 (815) LA2 (292) 5,5 LA1 (815) LP (770) LPD (1017) LA2 (292) 2 30 The door leaves can be positioned at the centre with respect to the thickness of the wall. Variable dimensions depending on type of hinge If a magneti clock is used, it is recommended to reduce the gap between door leaves to 3 mm Use a tradicional latch or the Push&Go EVO system (see 2.15 Magnetic striker plate for Push&Go EVO ) Oriented door 28 mm For the management of wall thicknesses see 2.6 Management of wall thicknesses. The values given in this table refer to a door with frame thickness 30 mm and door thickness 45 mm. When ordering hardware, the dimensions of the wall opening and the type of arm that will be used must be provided. A custom track kit be supplied based on the dimensions provided. LFMD = Wall opening width LPD = Passage dimension (LFMD - 183) LA1 = Door width (see table in paragraph 2.2 Single door horizontal dimensional drawing ) LA2 = Door leaf width (LFMD - LA1-93 variable depending on door LA1 dimensions and type of hinge used) LSD = Jamb opening (LFMD - 80) ESD = Exterior jambs (LFMD - 20) QF = Fixed dimension arms side QV = Variable dimension handle side 6

2.4 Double door horizontal dimensional drawing SMALL BASE Dimensional example Double ERGON door leaves LFMD (1720) ESD (1706) LSD (1646) 30 30 5,5 LA (815) LA (815) 5,5 5,5 If a magneti clock is used, it is recommended to reduce the gap between door leaves to 3 mm min. 35 45 LPD (1538) QV (425) QF (390) (quota fissa) (quota variabile in base alla larghezza dell anta) Use a tradicional latch or the Push&Go EVO system (see 2.15 Magnetic striker plate 9 for Push&Go EVO ) 9 LA1 (815) The values given in this table refer to a door with frame thickness 30 mm and door thickness 45 mm. In this case, it is possible to use track kits for single doors in combination with the dedicated union kit. For specifications see 2.14. and 2.15 LFMD = Wall opening width LPD = Passage dimension (LFMD - 182) LA1 = Door width (LFMD - 90) 2 LSD = Jamb opening (LFMD - 74) ESD = Exterior jambs (LFMD - 14) QF = Fixed dimension arms side QV = Variable dimension handle side The door leaves can be positioned at the centre with respect to the thickness of the wall. Oriented door 28 mm For the management of wall thicknesses see 2.6 Management of wall thicknesses. 7

2.5 Vertical dimension drawing HFM = 2150 HP = 2100 HA = 2084 VERTICAL DIMENSIONS HFM wall opening height HP passage height HA door leaf height * 1950 1900 1884 * 2000 1950 1934 * 2050 2000 1984 * 2100 2050 2034 * 2150 2100 2084 * 2200 2150 2134 * 2250 2200 2184 * Standard Available sizes HP = (HFM - 50) HA = (HFM - 66) Other measurements may be obtained by adjusting the connecting rod (see paragraph 2.13 Shortenable connecting rod kit ) of prepared oversized kits. For bespoke rods, ask Celegon s.r.l. for feasibility. 8

2.6 Management of wall thicknesses During opening, the Ergon system forces the door to recede from the arms side. In this way, when there are wall thicknesses of certain dimensions, the door approaches the jamb to the point in which they cross (see design below), which prevents the door from opening completely. On this page are some solutions that can be adopted. Centred door When varying the thickness of the frame the wall thickness limits do not vary 30 5 40 5 30/40 70 mm max thickness for 110 mm max thickness for SMALL BASE arm arm 28/38 The point at which the door and the jamb cross To increase the thickness of the wall you can add an item to the frame with a thickness less than that of the frame (e.g. Frame thickness 30 mm add spacer of thickness 25/20 mm). n this way you can increase the wall thickness by about 30mm every 2mm (e.g. Adding an element of 28 mm BASE arm wall thickness 140 mm; addition of two elements of 28 mm = BASE arm wall thickness 170 mm). These values are valid for a door of thickness 45 mm. Caution: Oriented door Placing the oriented door from one side with respect to the wall decreases the thickness limit of the wall. 30/40 not possible with max thickness 85 mm for SMALL BASE arm arm (*) (*) When using rounded jambs, the limit value is to be considered only on the flat surface of the jamb and not on the rounded part. 9

= = ERGON LIVING T.E. SLIM 2.7 Specific door processing minimum thickness 35 A 30 B 10 32 32 C 32 D 20 10 A ø2,5 ø20x20 ø8 ø20x20 4 UPPER PROCESSING DETAIL Variable heights based on the arm used A B C D BASE arm 185,5 276 96 44 SMALL arm 136,5 225,2 45,2 44 LOWER PROCESSING DETAIL A 4 8 80 32 32 8 A 30 ø30x20 ø8 10 IMPORTANT Position of the door brushes Arms side Lock side for door thickness 35 38 mm Lock side for door thickness 39 50 mm We recommend using a lock with the facing not exceeding 18 mm. 10

2.8 Exploded frame diagram (centred door) 130 100 a 267 127 c 267 d 307 List of components Ref. Description 197 60 10 30 100 Track 127 Upper bracket arm side 130 Upper bracket lock side 197 Lower bracket 267 Screws TSPCR ø 3x25 307 Rod guide 40 List of wooden components 267 b Where using jambs of thickness 40 mm, it is necessary recess the lower bracket (197) by 10 mm (see drawing). Ref. a b c d Description Upper crosspiece Vertical jamb bracket side Vertical jamb lock side Infill strips 11

2.9 Construction details of the vertical frame arms side Jamb arms side 35 L = HP - 14 R 15 R 15 30 40 30 30 X X DIMENSION TO BE RESPECTED X = WALL THICKNESS HP = PASSAGE HEIGHT SIDE IN VIEW 30 X min 28 X 30 25 Tolerance + - 0,5 0 Check coupling with guide rod (307) oriented door centred door 12

2.10 Construction details of the vertical frame lock side Jamb lock side 30 40 L = HP + 1 Tolerance + - 0,5 0 X X DIMENSION TO BE RESPECTED X = WALL THICKNESS HP = PASSAGE HEIGHT SIDE IN VIEW 13

2.11 Construction details of the upper crosspiece Valid for frame thickness 30 and 40 mm L = LFM - 16,5 L = LFM - 16,5 21,5 21,5 40 40 5,2 5,2 6 6 DIMENSION TO BE RESPECTED X = WALL THICKNESS LFM = WALL OPENING WIDTH SIDE IN VIEW oriented door X 7,5 45 X-52,5 X-45 2 centred door X 45 X-45 2 upper crosspiece track upper crosspiece For the centred door two mirrored upper crosspieces are needed upper crosspiece track upper crosspiece 14

2.12 Track adjustment to the width of the door to be achieved ARM SIDE with hole for bracket mounting (127) Phase 2 Drill flared hole ø5 on both sides for M5 TSPEI screws 12,5 10,5 Phase 1 Cut the track on the side indicated LB = WALL OPENING WIDTH - 29 Minimum size 671 mm BASE arm (with Soft Opening minimum size 771 mm) Minimum size 581 mm SMALL arm (with Soft Opening minimum size 671 mm) track cover caps SIDE TO BE CUT LC LFM Wall Opening Width LB Track Width 700 671 725 696 750 721 775 746 825 796 875 846 925 896 975 946 LB = LFM - 29 Phase 3 Shorten the track cover profile on the side indicated Track cover length including caps LC = A - (1 to 2 mm) A 15

2.13 Shortenable connecting rod kit Connecting rod adjustment for non-standard heights Phase 1 Cut extension label side Phase 3 alignment template label B Extension of connecting rod to be shortened A Part of connecting rod fixed length (DO NOT CUT) Phase 2 Assemble the two rods by putting them in together alignment template Phase 3 Perfectly align the two rods using the two templates placed on a plane surface Total rod length = HA + 3 mm Extension of connecting rod of fixed length (do not cut) A Extension of shortenable connecting rod B Phase 3 Phase 3 alignment template Phase 4 Tighten the screws (after assembly the rod must be perfectly straight) alignment template Item nr. HP max Dimension A fixed lenght Dimension B to be shortened 730250CP 2500 1258 HA - 1255 Available on stock 730300CP 3000 1508 HA - 1505 Available on request 16

2.14 Track union kit for double door with ERGON LIVING system 1 380 250 400 390 220 List of components Ref. Q.ty Description 220 2 Screws TSPCR ø 3x10 250 2 Track cover fixing insert 380 1 Track extension 390 1 Track extension covers 400 1 Track junction connector 2 The measurements refer to a jamb of thickness 30 mm. Use a tradicional latch or the Push&Go EVO system (see 2.15 Magnetic striker plate for Push&Go EVO ) * N.B. For wall thickness limits see paragraph 2.6 Management of wall thicknesses in this manual. LFM minimum 1600 mm with BASE arm with Soft Opening LFM minimum 1700 mm LFM minimum 1400 mm with SMALL arm with Soft Opening LFM minimum 1500 mm For dimensions smaller than those indicated, contact Celegon s.r.l. 17

3 Choice of track The sum of the selected tracks must match or be greater Arm side with bracket fixing hole (127) *L1 = LFM-58 2 than the Wall Opening Width e.g.: LFM 2000 n. 2 tracks of LFM 1000 (already made) LFM 1960 n. 2 tracks of LFM 1000 (to be shortened) LFM 2060 n. 2 tracks of LFM 1050 (to be shortened) L = LFM-20 Arm side with bracket fixing hole (127) *L1 = LFM-58 2 BEFORE Pay close attention to the final measurement L of the two assembled tracks which must be that as pre-established Arm side with bracket fixing hole (127) AFTER 4 Properly secure the track to the upper beam through the hole on the track extension (380). Before hanging the doors make sure that the tracks within them are clean. any thicknesses Side to be cut wall LC track cover caps 250 380 400 LC 390 A LC Shorten the track cover profile on the side indicated track cover length including caps LC = A - 103 2 Create the opening to block the secondary door leaf for the traditional latch OR For the Push&Go EVO system use the dedicated kit (see 2.15 Magnetic striker plate for Push&Go EVO ) 18

2.15 Magnetic striker plate for Push&Go EVO For use with double door leaves with ERGON LIVING system 253 393 253 223 223 List of components Ref. Q.ty Description 223 2 Screws TSPEI M 5x12 253 2 Plate fixing insert 393 1 Magnetic striker plate Kit union tracks item 564000 (see 2.14) Component not needed if using Push&Go EVO For processing specifications see Push&Go EVO technical manual 19

3. ASSEMBLY 3.1 Installation of hardware on the door leaf LOCATIONS FOR BRUSH (or seal) We recommend using a brush with density 3P without fin and projection from the door of 6/6.5 mm. To position these locations see paragraph 2.7 Specific door processing 210 Arms side 157 We recommend using a brush with density 3P without fin and projection from the door of 4/4.5 mm. With doors of less than 39 mm thickness, the brush should be placed only on one side, the lock will be decentralized with respect to the thickness of the door. To position these locations see paragraph 2.7 Specific door processing Lock side MAGNETIC LOCKING 20 175 210 List of components Ref. Q.ty Description 157 1 Upper plate with trolley 175 1 Lower plate 210 5 Screws TSPCR ø 4x40

3.2 Connecting rod assembly with upper and lower arm Mount the upper and lower arm on the rod. When inserting the bushing (327) pay attention to the pins on the same: they must fit into the hexagons present on the screw heads (207). 375 167 117 Assemble the guide rod (307) as shown in the following drawings, according to the thickness of jamb. In the case of using jambs of thickness 30 mm, it is necessary to remove the excess material (see drawing). 207 327 Jamb 30 mm Detail A 167 30 307 Caution! Fasten the screws carefully (207) using the 2.5 mm hexagonal key (375) and make sure that the arm is attached to the pin plane of the connecting rod. Material to be cut Jamb 40 mm 40 375 187 327 207 Detail B List of components Ref. Q.ty Description 117 1 Upper arm 167 1 Connecting rod 187 1 Lower arm 307 1 Rod guide 327 2 Rod rotation bush 207 4 Screws TCEI M 3x6 375 1 Hexagonal key 2.5 mm 21

3.3 Assembly of hinge side jamb to the connecting rod 127 117 267 IMPORTANT Support bracket 307 IMPORTANT Support bracket 197 267 187 List of components Ref. Q.ty Description 117 1 Upper arm 127 1 Upper bracket arm side 187 1 Lower arm 197 1 Lower bracket 267 10 Screws TSPCR ø 3x25 307 1 Rod guide In the case of using 40 mm thickness jambs, it is necessary to fix the lower 10 mm bracket (197) as shown in paragraph 2.8 Exploded frame diagram (centred door). 22

3.4 Assembly of frame and track 230 Detail C 127 IMPORTANT Support bracket 317 230 130 Detail D Upper crosspiece 100 ** 267 100 130 Jamb lock side * IMPORTANT Positioning for bracket fixing hexagon 3 mm * Upper crosspiece Jamb hinge side = Screw for fixing the track to the jamb and adjustment of jamb opening Hexagon 3 mm ** = Door adjustment screws Hexagon 3 mm Jamb lock side LS = Door width + 8,5 mm List of components Ref. Q.ty Description 100 1 Track 127 1 Upper bracket arm side 130 1 Upper bracket lock side 230 1 Screws TSPEI M 5x12 267 8 Screws TSPCR ø 3x25 317 1 Upper pivot 23

3.5 Installation of complete jamb N.B.: Pay close attention to level of the track and the plumb line of the jambs = = 24

3.6 Door leaf installation Arm side 335 Grease 2 3 1 117 157 187 4 280 5 List of components Ref. Q.ty Description 117 1 Upper arm 157 1 Upper plate with trolley 187 1 Lower arm 335 1 Upper arm fixing pin 280 1 Hexagonal screwdriver 2.5 mm 25

3.7 Door leaf and frame adjustment Jamb opening adjustment +/- 2 mm 3 Door leaf adjustment +/- 2 mm 5,5 Track fixing screws the jamb and regulation of Jamb opening +/- 2 mm Door leaf adjustment and centring screws Door Jamb lock side CAUTION: AFTER ADJUSTING THE DOOR PROPERLY SECURE THE THREE LOCKING BOLTS Jamb arms side 3 Door leaf adjusting and centring screw lower arm +/- 2 mm Door leaf adjustment 26

3.8 Soft Opening damper installation (Optional) 402 410 List of components 406 408 404 Ref. Q.ty Description 402 1 Activator 404 2 Screws TSP+ M3x8 406 1 Activator positioning template 408 1 Sticker 410 1 Soft Opening Phases of installation 1. Assemble and secure the jambs and track to the wall. 2. Check that the trolley provided has support for the attachment of the Soft Opening. activator location location Soft Opening fixing location for template (406) hexagon 2,5 mm arm side 3. Slide the activator (402) into its location in the track paying attention to the instructions. The activator must be brought temporarily to the stop on the hinge part of the arm. 4. Attach the door leaf and secure the hinge arms. Follow the standard settings of the door and open the door leaf completely. N.B. In the case of a door already installed insert the activator in the location of the track after having dismantled the track cover. 27

A 410 410 404 5. Push the hook (A) to load the Soft Opening (410) and secure it to the trolley with the screws (404) supplied. 408 location for template (406) 406 supporting template 406 402 hexagon 2,5 mm Jamb arms side jamb Door leaf 6. Join the two parts of the template (406) using the sticker (408). Take the door leaf to 45 and place the template (406) to the jamb dragging the activator (402) into the correct position, firmly attach the locking screws. 7. Check the correct operation of the Soft Opening. Complete the installation of the door. 28

3.9 Mounting frames and track cover profiles 250 147 220 List of components Ref. Q.ty Description 147 1 Track cover profile 220 2 Screws TSPCR ø 3x10 250 2 Track cover fixing insert 29

NOTE 30

NOTE ERGON LIVING T.E. SLIM 31

Composizione grafica: Studio Gallo Design srl - Camposampiero (PD) ERGON living is an idea by CELEGON 30035 Mirano (Venezia) Via G. Galilei, 6 - Z.I. T +39 041 572 8404 F +39 041 572 8522 www.ergon.eu info@ergon.eu