ADJUSTABLE SPEED DRIVES. AS1 Drive

Similar documents
S11 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES FS1

VF-nC1 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

E3 Adjustable Speed Drive Engineering Specification

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

TOSVERT TM VF-nC3 Parameter List

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Manual Overview...1 2

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Inverter Drive /Vector Drive Motors & Controls

Design Specifications Operator Keypad Environmental and Operating Conditions

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

VFS11 Parameter List for up to CPU version 105

General Specifications FECA-TE /2010. Phone: Fax: Web:

6.9 Jump frequency - Avoiding frequency resonance

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

AF91 Adjustable Frequency Drives Series B

Before you operate the inverter, the parameters that you must first program are the basic parameters.

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

FUJI Inverter. Standard Specifications

Phoenix DX Clean Power (18 Pulse) AC Drive

Micro and Mini Inverters

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

The new Yaskawa Varispeed G7 Inverter

Fan and Pump AC Inverter

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

VFS9 Parameter List for Version110 or later

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

9. RS485 Communication

Multi-function, Compact Inverters. 3G3MV Series

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

CHAPTER 8 PARAMETER SUMMARY

9. RS485 Communication (Option)

13. Before making a service call Trip information and remedies

HPVFP High Performance Full Function Vector Frequency Inverter

GS1 Parameter Summary Detailed Parameter Listings...4 9

Product description. At a glance. Customer benefits

HV580L Series Frequency Inverter User Manual

General Purpose AC Drives

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

SX (400 V) System configuration

SX (690 V) System configuration

WJ200 series Pursuing the Ideal Compact Inverter

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

NGS N01 LIMESTONE CRUSHER ELECTRICAL SPECIFICATIONS

HV580 Series Frequency Inverter User Manual

General Purpose Drives

AC Elevator Drives. Made in the U.S.A.

SYSDRIVE 3G3FV Series

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

ACH550 HVAC Drive Submittal

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup...

SX (400V) System configuration

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

ECET 211 Electric Machines & Controls Lecture 9-1 Adjustable-Speed Drives and PLC Installations (1 of 2)

Warning!! 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life.

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

NX series Constant and variable torque Variable Speed Drives for induction motors

CTi Automation - Phone: Fax: Web: -

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

Options & Accessories

Hyundai Inverter-N700E. The Controlling Solution of Powerful Inverter Brand

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

EN 50178, IEC

SECTIONS , (15040, 15767, 15950, 16269) Guide Specification for VARIABLE SPEED DRIVES with Optional Bypass

ADTECH Solar inverter

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Options & Accessories

A700 Series. Variable Frequency Drives UNSURPASSED POWER AND CONTROL 1 /2-700 HP

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

Power Regenerative Converter, THYFREC CV240S

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS

Frequency Converter Fv vector control converters for universal applications

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

INVERTER FR-A800 Plus

VS-616PC5/P5 Series User s Manual

Transcription:

ADJUSTABLE SPEED DRIVES AS1 Drive

Toshiba s New ASD Product Line The AS1 drive builds on Toshiba s history of supplying powerful, reliable, and versatile drives. We have combined our best drive features with the latest technologies, making the AS1 the new contender in the PWM control drive market. AS1 Product Family Advanced Design The modular construction of the AS1 allows the unit to be installed into nearly any application quickly and easily. The laminated bus-plane technology used in the AS1 means a reduced component count, better reliability, and easier service. Simple Programming Toshiba s unified programming philosophy means that you can operate the AS1 drive with little or no programming. At the same time, the AS1 maintains one of the most expansive parameter sets in the industry, allowing you to fine-tune the drive for your specific application. Tough Environment The AS1 drive is designed to operate in extreme environments. It can operate in temperatures up to 122 F without derating and can also be configured for use in temperatures of up to 140 F. The AS1 is also designed to be used in a sealed cabinet design. This allows integrators to mount the AS1 heat-sink external to the drive cabinet for simple and efficient cooling of the unit. Improved Control The AS1's new PID algorithm makes it easier than ever to dial in your process control application. New parameters such as a delay filter and a process control lower limit, and new functions such as the AS1 s new Speed PID and easy positioning algorithms give the drive expanded capabilities to take on difficult applications. Quick-Snap Option Cards

Rugged Design, Advanced Operations Powerful Performance The AS1 offers both sensorless and feedback vector control providing heavy duty performance. Using its new Motor-Over-Flux Braking Technology, the AS1 can provide as much as 30% of its rated power for use in stopping a heavy or high inertia load without the use of a dynamic brake resistor. Smart Operation Toshiba s My Function programming set allows the AS1 to operate as a simple PLC. Basic logic function programming can now be done directly on the ASD. Fault-Tracing Issues with your application will no longer be a mystery with AS1's fault-tracing algorithm. By accessing the faulttracing parameters, you can isolate exactly where the trouble is located. Easy Communications The AS1 is designed to accommodate multiple stackable option cards that mount underneath the unit s keypad quickly and easily. In addition, the drive can accept two inputs from external communication units via the two onboard RS485 communication ports. Broad Compliance Large Horsepower AS1 The AS1 is certified by a broad range of governing and regulatory bodies making it a truly global product. N998

Easy-to-Use Operation Panel Names and Functions RUN Light Lit when a RUN command is active but output frequency is 0 Hz. Blinks when operation begins. Display Displays the operating frequency, monitor items, parameter information, trip messages, etc. EASY Key Light Lit when the EASY key is enabled. Percent (%) Lamp Lit when a numeric value is displayed in percent. Hertz (Hz) Lamp PROGRAM Light Lit when the inverter is in PROGRAM mode. This lamp blinks when the parameters AUH or GR.U are selected. Lit when a numeric value is displayed in Hz. UP Key MONITOR Light Lit when the inverter is in MONITOR mode. This lamp blinks when the drive s trip history is being displayed. MODE Key Cycles between the operating frequency display, monitor items, parameters, and trip messages. Local RUN Light ENTER Key Lit when the drive may be started from the RUN key. DOWN Key RUN Key Used to start the drive if the RUN light is lit. STOP Key Used to stop the drive if the RUN light is lit. Double press STOP key for emergency stop. EASY Key Access to EASY parameters. May also be enabled as a local/remote key. Serial RS485 Connection Two-wire RS485 connection for communications and connection to external devices such as a remote keypad.

AS1 Drive Standard Specifcations Model Range 0.5 to 100 HP 1 to 800 HP 2 to 10 HP 2 to 700 HP Voltage Rating 200 to 240 V 380 to 460 V 500 to 600 V 500 to 690 V Input Tolerance Voltage: ±10%, Frequency: ±5% Current Overload DC Reactor Dynamic Braking Control System Output Frequency Range Frequency Accuracy 100% Continuous, 150% for 60 Seconds, 165% for 2 Seconds 200 V Input Class, 15 to 60 HP and 400 V Input Class, 25 to 100 HP: Built-In DC Link Reactor; Reactors Required on Larger Units, Optional on Smaller Units (HP) Dynamic Braking Resistor Included on Units < 300 HP; Transistor for Larger Units/Resistor Sold Seperately Sinusoidal Pulse Width Modulation (PWM) Control 0 to 500 Hz Analog Input: ±0.2% of Maximum Output Frequency (at 25 ±10 C); Digital Input: ±0.01% (±0.022 Hz) of Output Frequency Voltage/Frequency Characteristics Constant Torque, Square Reduction Torque, Auto-Torque Boost, Sensorless and PG Feedback Vector Control, etc. Jump frequencies Voltage: ±10%, Frequency: ±5% PID Control Adjustment of Proportional Gain, Integral Time, Differential Time, and Delay Filter Torque Control Control of Output Motor Torque via Set Point from 0 to 10 V Analog Input PWM Carrier Frequency Adjustment 200 V, 45 kw or 400 V, 75 kw or less, Adjustable Between 1.0 to 16 khz; 200 V, 55 kw or 400 V, 90 kw or more, Adjustable Between 2.5 to 8 khz Analog Inputs 0 to 10 Vdc (Input Impedance Zin: 30 kω), 0 to ±10 Vdc (Zin: 22 kω), 4 to 20 madc (Zin: 242 Ω) Analog Outputs FM Terminal: 0 to 1 ma, 0 to 20 ma, 0 to 10 V: AM Terminal: 0 to 1 ma, Each Programmable to Any of 65 Functions Digital Inputs Up to 8 Digital Inputs, Each Programmable to 67 Functions, Normally Open or Normally Closed Digital Outputs One Form-C Relay (FM) Output (250 Vac, 2 A or 30 Vdc,1 A); Two Open Collector Outputs (24 Vdc, 5 ma) Acceleration/Deceleration Time DC Braking Forward Run/Reverse Run 0.01 to 6000 Seconds; Four Selectable or Automatic Acceleration/Deceleration Times; Two Adjustable S-Pattern Acceleration/Decelerations Adjustment of DC Braking Start Frequency (0 to 120 Hz), Braking (0 to 100%), and Braking Time (0 to 20 Seconds); Includes Emergency Stop Braking and Motor Shaft Fix Control Functions F-CC Closed will Forward Run, R-CC Closed will Reverse Run, F-CC and R-CC Closed will Reverse Run; ST-CC Opened will Coast Stop; Emergency Stop Using Panel Operation or Terminal Board Jog Run Preset Speed Operation Retry Soft Stall Cooling Fan ON/OFF Operation Panel Key Operation On/Off Control Jog Mode Allows Jog Operation from Operation Panel; Jog Run Operation by Terminal Board Possible by Setting Parameters 15 Preset Speeds Available by Switch Input; Programmable Accel/Decel Time; Torque Limit and V/F Capable of Restarting After Checking Main Circuit Elements in the Event of a Fault; Up to 10 Retries with Adjustable Delay (of up to 10 Seconds) Between Each Retry Automatic Load Reduction Control in the Event of Overload Condition (Default: OFF) Cooling Fan Stops Automatically When Not Needed Keypad Lockout Selectable Between STOP Key Only, MODE Key Only, etc.; All Key Operations can be Prohibited Regen Power Ride Through In case of a momentary power failure, the VFD can use regen energy to stay powered. (Default: OFF) Auto-Restart Operation AS1 can catch a spinning motor and safely bring it to speed without faulting. (Default: OFF) Simplified Pattern Operation Selectabe: Eight Patterns in Two Groups from 15 Speed Operations; Maximum 16 Types of Operations Possible; Terminal Board Operation/Repeat Operation Possible Commercial Inverter Switching Possible to Switch Operation Using Commercial Power Source or Inverter Light Load, High-Speed Operation Increases Efficiency of Certain Machines by Increasing Rotational Speed of Motor when Operated with Light Load Drooping Function When Two or More Inverters Operate a Single Load, Drooping Function Helps Evenly Share Load Override Function Allows User to Add to the Primary Frequency Command. (E.G. Trim input) My Function Operation My Function provides digital logic and comparator operations as well as timers, counters, and other control functions to provide advanced control operations directly on the VFD (similar to a micro PLC). Color RAL7016 (Charcoal Gray) Environment Indoor Use, Non-Corrosive/Non-Combustible Environment; Altitude: 3000 Meters or Less (Derating Necessary for Elevations Over 1000 Meters); Keep Out of Direct Sunlight Ambient Temperature -10 to +60 C; Remove Upper Cover if 40 C or Higher, Maximim 60 C with De-Rate) Storage Temperature -25 to +70 C Relative Humidity 20 to 93% (Free from Condensation) Vibration 5.9 m/s 2 {0.6 G} or Less (10 to 55 Hz) Frame Size AS1 2 3 4 5A 5B 6 7A 7B 8 9 10 11 12 13 14 15 H 9.1 10.2 11.6 11.6 15.7 16.5 21.7 21.7 24.8 26.8 30.8 37.4 37.4 37.4 45.3 45.3 H W 5.1 6.1 6.9 8.3 9.1 9.4 9.4 12.6 12.6 12.2 13.8 13.0 16.9 23.0 34.6 43.6 W D 6.0 6.5 6.5 7.5 7.5 8.3 9.5 9.5 11.4 14.6 14.6 14.6 14.6 14.6 14.6 14.6 D 200-240 V 0.5-2 3-5 7.5 10 15-20 25-30 - 40-60 75 100 - - - - - - 380-460 V 1-3 5 7.5-10 15 20-25 30 40-50 - 60-100 125 150 200 250 300-450 550-600 700 HP 500-600 V - - - 2-10 - - - - - - - - - - - - 500-690 V - - - - - 3-30 - - 40-100 - - 125-200 - 250-450 - 500-800 Enclosure Rating IP20* IP00* *IP20 Approximately Equal to NEMA 1; IP00 Provides No Protection, Chassis Unit Unit s Horsepower Unit s Dimensions Voltage