Using DIAGNOSE.EXE with a ColorQuest 45/0

Similar documents
The World s Most Trusted Name In Color Quality. HunterLab

Measuring Transparent Bottles

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

UltraScan PRO Supplemental Manual for EasyMatch QC

Shimadzu RF-5301 Fluorimeter operation guide for students

Color Insight: Color Optimization

Software Manual for the Economy LBIC Demo

Automated Double Aperture Accessory

White Paper. Reflective Color Sensing with Avago Technologies RGB Color Sensor. Reflective Sensing System Hardware Design Considerations

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

EDUCATION EXPERIMENT. Determining Color Difference (Delta E) Introduction

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Nano-100 Spectrophotometer. Brief introduction

SPECTRAL SCANNER. Recycling

UV-Vis-NIR Spectrophotometer Quick Start Guide

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Whiteness indices and UV standards

In sum the named factors cause differences for multicolor LEDs visible with the human eye, which can be compensated with color sensors.

ISET Selecting a Color Conversion Matrix

Imaging Photometer and Colorimeter

AMERICAN NATIONAL STANDARD

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

We bring quality to light. MAS 40 Mini-Array Spectrometer

EA SPORTS PGA TOUR Golf Team Challenge Upgrade Instructions

Achieving 100,000 : 1 contrast measurement

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Zeiss 880 Training Notes Zen 2.3

MAXYM Mortiser Operating Manual

Head Tracker Range Checking

truepixa Chromantis Operating Guide

SUNTEST CPS+ / XLS+ Software documentation Version 1.4 SUNTEST ATLAS SUNTEST --> ENTER. Start. Stop ESCAPE

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

PD-3000UV. INSTRUCTION MANUAL UV-VIS Spectrophotometer OMA IMPORTANT!

Using the Integrating Sphere in the Multiple Application Platform (MAP)

1/8 m GRATING MONOCHROMATOR

Color Measurement with the LSS-100P

Contents I. APPLICATIONS II. SPECIFICATIONS III. PRINCIPLES IV OPERATION V. MAINTENANCE

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

Using the Image Manager

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Reports. Eye-One. Evaluation of Gretag Macbeth. Brent Cavanaugh - Updated by Paul Huhtala Updated NOVEMBER 2005

OPT3: Operating Procedure for Horiba Jobin Yvon LabRam Aramis Raman/PL System See LabSpec_6_2 General User Quick Start Guide on the computer desktop

VS7550 VUV/UV Mini Spectrograph Operating Manual

Kurz Instruments Inc. 19 August 2010

UVA/B Light Meter. Instruction Manual. UVA/B Light Meter Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

TEXTILE TECHNOLOGY. Portable Color Spectrophotometer Measurements of Cotton Color in Remote Locations

Metamerism, Color Inconstancy and Chromatic Adaptation for Spot Color Printing

MK350 Portable Spectrometer

BiRT-2.0 Bi-directional Reflectance and Transmittance Distribution Function Measurement System

Renishaw InVia Raman microscope

LSM 780 Confocal Microscope Standard Operation Protocol

FluorCam PAR- Absorptivity Module & NDVI Measurement

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

Zeiss LSM 780 Protocol

eflex 75x/300x Digital Microscope with Flexible Neck User Guide

Lab 7: Magnetic Field of a Solenoid

Figure 1. Oil-immersion objectives available for use with the Lionheart FX.

Gentec-EO USA. T-RAD-USB Users Manual. T-Rad-USB Operating Instructions /15/2010 Page 1 of 24

GainMaker Node SMC Status Monitor Transponder Installation Instructions

Instruction Manual for the Software of ASSAN V2 Series Receiver

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

DRC. Colorant Recipe Prediction Software USER MANUAL DRC

Things to check before start-up.

The CO2 Sensor Calibration Kit

Measurement Method of High Absorbance (Low Transmittance) Samples by UH4150 INTRODUCTION

Introduction to the operating principles of the HyperFine spectrometer

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

Spectrophotometer CM-3630 PaperControl Software

Zeiss 780 Training Notes

Olympus xcellence Software - basic user guide

Experiment E-6 Rayleigh Scattering

Agilent 8902A Measuring Receiver Product Note

TRAINING MANUAL. Olympus FV1000

Miniature Spectrometer Technical specifications

Zeiss LSM 880 Protocol

Physics 4C Chabot College Scott Hildreth

USER MANUAL. ScanFlex AUTOMATED SCANNING DEVICE SCANFLEX Rev 5.0

CS-2000/2000A. Spectroradiometer NEW

MAXI Remote Location Kit MRLK 900 Installation and Configuration Manual

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Seized Drugs Operational Guidelines for the Thermo FTIR Comparative and Analytical Division

T 519 om-96 SUGGESTED METHOD 1970 OFFICIAL STANDARD 1978 OFFICIAL TEST METHOD 1980 REVISED 1986 REVISED 1991 REVISED TAPPI

Lighted Print Viewer Owners Manual

Care and Maintenance of Milling Cutters

OP735. Benchtop Optical Power Meter Instruction Manual

SCATT BASIC SHOOTER TRAINING SYSTEM USER MANUAL. SCATT company Tel: +7 (499)

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

Trilogy Laboratory Fluorometer. User s Manual

Widefield 1. Switching on

MityCAM-B2521 EPIX XCAP User s Guide

FAG PRESTO DX. FAG PRESTO-DX preliminary User Manual. FAG GRAPHIC SYSTEMS S.A. 3, rue de la Vigie CH-1003 Lausanne Switzerland

Automated Spectral Image Measurement Software

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

IBIL setup operation manual for SynerJY software version

LumaSpec 800S User Manual

FUJICOLOR CRYSTAL ARCHIVE PAPER SUPREME HIGH DEFINITION

Transcription:

Insight on Color November, 1999, Vol. 11, No. 11 (Rev. 5/02) Using DIAGNOSE.EXE with a ColorQuest 45/0 The DIAGNOSE.EXE program, which may be used to assess instrument performance and diagnose potential problems, is installed automatically with HunterLab s Universal and EasyMatch Coatings software packages. For users of other software packages, the program may be forwarded to you from HunterLab Customer Support if a problem with your instrument is suspected. Three files must be installed in the same folder on your computer in order to run the diagnostics: DIAGNOSE.EXE, ENGLISH.DGM, and CQ#####.CAL, the instrument calibration file. Note: Only one ColorQuest calibration file, the one matching the instrument to be tested, may be located in the folder containing DIAGNOSE.EXE while the program is in use. Perform the following steps periodically to assess instrument performance or if there is any reason to suspect that the instrument is not operating properly. Perform the following steps to complete all the available diagnostics. If any diagnostic results are outside the stated range, follow the instructions for contacting HunterLab that are given at the end of the procedure. 1. Exit Universal, EasyMatch, or your instrument control software. 2. Clean the white tile and black glass as described in your User s Manual. The instrument and lamp should be warm before running the diagnostics. The standard tiles should be dry and at room temperature. 3. Locate the DIAGNOSE.EXE program file (in your UNIVERSE or EZMATCH folder if you are using one of those packages) using the Windows File Manager or Windows Explorer. Double-click on the DIAGNOSE name to open the program. 4. On the opening Diagnose screens, choose 1, ColorQUEST, and the serial port to which the instrument is connected. The main menu screen then appears. Copyright HunterLab 2002 Page 1 All Rights Reserved

Available functions Configuration of the current instrument 5. Place the white calibrated tile at the sample port. Press F1 to perform the Signal strength test. The raw A/D counts for the white tile are then displayed for each measurement wavelength. The highest A/D value shown should be between 32,768 and 45,875. Press Home to exit the menu. Copyright HunterLab 2002 Page 2 All Rights Reserved

6. Place the black glass at the sample port and press F1 again. All of the A/D values should be between 655 and 2,621. Press Home to exit the menu. 7. Press F2 to standardize the instrument. Standardization prompts very similar to those seen in Universal Software will be obtained. Press Insert after completing the instructions described by each prompt. No confirmation is given when standardization is complete. Copyright HunterLab 2002 Page 3 All Rights Reserved

8. Place a sample or tile at the reflectance port and press F3, Read Sample. Press 1 to perform timed readings of the sample. Type an interval between reads and press Enter. This interval should be short enough that you can examine several measurements quickly, but long enough that you have time to note the values. Five seconds is suggested. The spectral and tristimulus readings of the sample will be shown and continuously updated at the interval selected. Press - on the number pad to return to the Read Sample menu. 9. Press 2 to perform the repeatability test. Place the white calibrated tile at the reflectance port. Press Insert. Twenty reads of the tile will commence and Delta L*, a*, and b* values (between the first and last readings) will be displayed on the screen along with delta values for reflectance at each wavelength read. If any of the spectral value deltas is outside the following specifications, record the result and contact HunterLab Customer Support. Spectral Data Specifications, Delta, Spectral reflectance: Should be 0.15 at 400, 410, 700, and 710 nm Should be 0.10 at all other wavelengths. Copyright HunterLab 2002 Page 4 All Rights Reserved

Press - on the number pad to return to the Read Sample menu. 10. Press 3 to perform the drift test. Place the white tile at the reflectance port, press Insert, and wait 30 minutes for the test to be automatically performed. Delta L*, a*, and b* values (between the first and last readings) will be displayed on the screen along with delta values for reflectance at each wavelength read. If any of the delta values for L*a*b* are greater than ±0.10 unit, record the result and contact HunterLab Customer Support. Press Home to return to the diagnostics menu. 11. Press F4 to display the white tile data stored in the instrument. Press Home to exit to the diagnostics menu. Copyright HunterLab 2002 Page 5 All Rights Reserved

12. Press F8 to change the setup for diagnostic testing. You will obtain the same selection screen listing the instruments that was shown when the software was first entered. 13. When all diagnostics are complete, press Esc to exit the diagnostics program. If any of these diagnostics indicates a problem, contact HunterLab Customer Support at (703) 471-6870 and describe the tests performed and the exact results obtained. If the sensor passes all diagnostics, enter your software package, standardize the ColorQuest, and commence normal operation. Other Diagnostics for the ColorQuest 45/0 Several diagnostic procedures are described in your instrument User s Manual and may also be used to assess instrument operation and performance. These tests are performed within your normal software package. White Tile Check: Standardize the instrument using the standard area of view with the UV filter out. Set your data display to show absolute XYZ values using the D65 illuminant and 10 observer. Read the white calibrated tile and compare the values read to those shown on the standards card. All values read should be within ±0.10 units of the values shown on the standards card immediately after standardization. If any of the values are out of this specification, clean the white tile and black glass and standardize and read again. Green Tile Check: Standardize the instrument using the standard area of view with the UV filter out. Set your data display to show absolute XYZ values using the D65 illuminant and 10 observer. Read the green calibrated tile and compare the values read to those shown on the back of the tile. All values read should be between ±0.30 units of the values on the back of the tile immediately after standardization of the instrument. If any of the values are out of this specification, clean all the tiles and perform the test again. More complete instructions on checking the green tile are given in your User s Manual. Copyright HunterLab 2002 Page 6 All Rights Reserved

For Additional Information Contact: Technical Services Department Hunter Associates Laboratory, Inc. 11491 Sunset Hills Road Reston, Virginia 20190 Telephone: 703-471-6870 FAX: 703-471-4237 www.hunterlab.com Copyright HunterLab 2002 Page 7 All Rights Reserved