RT-3 UNIT RELAY 4-POINT TERMINAL

Similar documents
RT-3 UNIT RELAY 4-POINT TERMINAL

Palm-sized, 16-channel Relay Terminals

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

TV-15, 30 AMP (1 Form A) Power Relay

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Relay for control panel of 1c 10A, 2c 5A and 1a 16A

Slim compact safety relay

SLIM COMPACT SAFETY RELAY

MINIATURE RELAY FOR WIDER APPLICATIONS

AQ-R SOLID STATE RELAY FEATURES

Compliant with European standards 1a/1c 6A Slim power relays


30 AMP POWER RELAY WITH SPACE SAVING DESIGN

EN GWT compliant Low profile: 15.7mm.618inch height 1a/1c 16A power relay

Suitable for lighting and motor load, 1 Form A 50A latching relays

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

High switching capacity 1a/1c 30A power relays

CP RELAYS POWER TYPE. TYPICAL APPLICATIONS Defoggers, Ignitions, Heaters, Accessories, Powered windows, etc. ORDERING INFORMATION TYPES

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

1a 16A power relay for micro wave oven

Transistor drive 2c/4c 5A slim power relays

Compact Relay Family with Forcibly Guided Contacts

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage


1a 8A, 1a1b/2a 5A small polarized power relays

1 GHz capable, 3 W carrying power (at 1 GHz), 50Ω impedance and 2 Form C relays

10 A MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A 1 Form A. Initial breakdown voltage* 2. Vibration resistance.

10A to 40A hockey puck type FEATURES

8 A MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES

1a/1c 5A/10A small power relays

1.5 GHz MICROWAVE RELAYS. FEATURES 1. Excellent high frequency characteristics. V.S.W.R. (Max.) 1.5 (at 900 MHz) Impedance

ACCESSORIES. Type No. of poles Item Part No. Performance. Contact arrangement 1 Form C 2 Form C Max. continuous current (Ambient temperature:

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY

16A POWER RELAY FOR MICRO WAVE OVEN

UP TO 8GHz SMALL MICROWAVE RELAYS

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

COMPACT PC BOARD POWER RELAY

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

RK RELAYS FEATURES. SPECIFICATIONS Contact. 1.5 GHz MICROWAVE RELAY

Timers GE1A. GE1A Series ON Delay Timers Single Function

3 GHz capable, 10 W carrying power (at 3 GHz), 50Ω/75Ω impedance and 1 Form C relays

MINIATURE POWER RELAY mm inch. 2 Form A, 1 Form A. 1 Form B. Initial breakdown voltage* 2 8 A 250 V AC 8 A 30 V DC 250 V AC, 30 V DC

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

1a/1c/2a/2c/5A/10A power relays for power supply

Slim type SSR for 1 A and 2 A control AQ-G RELAYS

1a/1c/2a/2c/5A/10A power relays for power supply

SUPER MINIATURE PC BOARD TYPE AUTOMOTIVE RELAY

1a 8A, 1a1b/2a 5A small polarized power relays

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

High Sensitivity, with 100mW nominal operating power, in a compact and space saving case

COMPACT AND HIGH CAPACITY GENERAL PURPOSE POWER RELAYS

High capacity SSR, both tab and screw terminals available

High Capacity of Max. 1,000 V DC Cut-off Possible

Model Number Structure

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

Compact Flat Size Relay for Automotive. (Unit: mm inch)

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

Slim type with high capacity up to 4A DC load type also available

MICRO-ISO AUTOMOTIVE RELAY

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure


Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

COMPACT PC BOARD POWER RELAY FEATURES. Characteristics. Initial breakdown voltage* 1. Vibration resistance

6mm Interface Relays RV8 Series

For FPC. FPC connectors (0.2mm pitch) Back lock

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Details on the New G2RS

LOW-PROFILE SURFACE-MOUNT RELAY

MINIATURE POWER RELAY IN DS RELAY SERIES FEATURES resistance ORDERING INFORMATION. Ex. DSP 1 L DC12V R

COMPACT PC BOARD POWER RELAY

UNIQUELY DESIGNED RELAY FEATURES

Micro-ISO Automotive Relay. (Unit: mm inch)

Slim type with high capacity up to 4A DC load type also available

For FPC. FPC connectors (0.3mm pitch) Back lock

FPC connectors (0.3mm pitch) Front lock with FPC tabs

4 AMP POLARIZED HIGH DENSITY RELAY WITH HIGH SENSITIVITY FEATURES

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

4 mm height! 2 A high capacity 1 Form C type ultra thin, super miniature relay

Capacitive Proximity Sensor

1a 10 A,1a1b/2a 8 A small polarized power relays

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

SUNSTAR 传感与控制 TEL: FAX: POWER PhotoMOS RELAYS (Voltage Sensitive Type) Photo

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Load for air conditioner 1a 20A power relays

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

20 AMP POWER RELAY HG RELAYS

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

POWER PhotoMOS RELAYS 1-channel (Form A) Type FEATURES

LOW-PROFILE SURFACE-MOUNT RELAY. Characteristics. Initial breakdown voltage. Initial surge voltage. Temperature rise* 2 (at 20 C) Max.

LOW PROFILE 2 FORM C RELAY TQ RELAYS Ð Ð.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC. 200 mw.

SMALL POLARIZED RELAY WITH HIGH SENSITIVITY

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

8 A MINIATURE POWER RELAY IN DS RELAY SERIES

Transcription:

Slim, Space-saving, -point Unit Relay RT-3 UNIT RELAY -POINT TERMINAL [PA-N Relay type, PhotoMOS Power (Voltage sensitive type)] -point Terminal [PA-N relay, PhotoMOS Power (Voltage sensitive type)] Mountable relay FEATURES. Slim, space-saving type (33 mm.299 inch wide) with four independent points on a base measuring 33 67 mm.299 2.638 inch. This contributes to a more compact control panel. 2. Can be mounted on a DIN rail or mounted directly (by screw). 3. Equipped with an LED display to allow easy confirmation of operation.. Possible to select a relay for use in the -point terminal in accordance with its application. RT-3 Unit relay PA-N relay PhotoMOS Power (Voltage sensitive type) RoHS compliant TYPES. RT-3 Unit relay Contact arrangement Rated input voltage Part No. Form A Standard packing: Carton: pc.; Case: 20 pcs. Note: PA-N relays are installed. 2 V DC RT3SN-2V 2 V DC RT3SN-2V 2. -point Terminal Type Rated input voltage Part No. PA-N relay, PhotoMOS Power type (Voltage sensitive type) 2, 2V DC RT3BB Standard packing: Carton: pc.; Case: 20 pcs. 3. Mountable relays for -point Terminal (per relay, at 25 C 77 F, initial) Product Name PA-N relay PhotoMOS Power type (Voltage sensitive type) Notes:. Never install relays into this product other than those given above. Doing so will cause malfunction, breakdown, and breakdown of the connected product. 2. Cannot be equipped with PhotoMOS Power standard type relays. However, equipping with voltage-sensitive type of PhotoMOS Power type is possible. RATING. RT-3 Unit relay ) Input ratings (per PA-N relay) Part No. Rated input voltage Input current (at rated input voltage, 20 C 68 F) Part No. APAN32, APAN32 AQZ0 D (DC only) AQZ20 D (AC/DC dual use) Allowable variation of rated input voltage (20 to 55 C to 3 F) RT3SN-2V 2 V DC Approx. 0.7 ma (Relay 9.2 ma LED.5 ma) 2 V DC ± 0% RT3SN-2V 2 V DC Approx. 7.6 ma (Relay.6 ma LED 3.0 ma) 2 V DC ± 0% ASCTB369E 2070-T

RT-3 Unit Relay/-point Terminal (PA-N Relay type) 2) PA-N relay coil specifications (Reference value) 3) Output ratings (per PA-N relay) Pick-up voltage (Initial) (at 20 C 68 F) Note: During -point simultaneous operation, the rating per point is also as shown above. Drop-out voltage (Initial) (at 20 C 68 F) Coil resistance (±0%) (at 20 C 68 F) Relay part No. Rated operating power APAN32 70%V or less 5%V or more,309 Ω 0 mw of Rated voltage of Rated voltage APAN32 (initial) (initial) 5,236 Ω 0 mw Specification Item Specifications Contact data Expected life Contact rating (Resistive load) Max. switching power (Resistive load) Max. switching voltage Max. switching current Min. switching load (Reference value) Mechanical life Electrical life (Resistive load) 3 A 250 V AC, 3 A 30 V DC 750 VA (AC), 90 W (DC) 250 V AC, 30 V DC 3 A ma, 5 V DC Min. 2 0 7 (at 80 times/min.) Min. 3 0 : 3 A 250V AC Min. 3 0 : 3 A 30V DC Min. 0 5 : 2 A 250V AC Min. 0 5 : 2 A 30V DC 2. -point Terminal ) Input ratings (per relay) Rated input voltage Allowable variation of rated input voltage Allowable input current 2, 2V DC 2V DC±0%, 2V DC±0% 0.2A Note: The input voltage value above is the allowable current when no relay is installed. Please note that input voltage is determined by the type of relay installed. 2) Input rating when PA-N relay installed (per relay, at 20 C 68 F) Type APAN32 APAN32 Rated input voltage 2V DC 2V DC 3) Input rating when PhotoMOS Power voltage sensitive type installed (per relay, at 25 C 77 F) Type AQZ 0 D Rated input voltage 2, 2V DC ) Output rating (per relay) Operate voltage (Initial) Max. 9.5V DC (Relay max. 8.V include diode max..v) Max. 7.9V DC (Relay max. 6.8V include diode max..v) Operate voltage (Initial) Max. 5.V DC (Relay max..0v include diode max..v) Allowable load voltage 600V (DC), 600V (AC peak value) Note: The value above is the allowable value when no relay is installed. Please note that limitations apply to the load voltage and current depending on the type of relay installed. 5) Output rating when PA-N relay installed (per relay, at 20 C 68 F) Note: During -point simultaneous operation, the rating per point is also as shown above. Release voltage (Initial) Min..0V DC (Relay min. 0.6V include diode min. 0.V) Min..6V DC (Relay min..2v include diode min. 0.V) Release voltage (Initial) Min..2V DC (Relay min. 0.8V include diode min. 0.V) 6) Output rating when PhotoMOS Power voltage sensitive type installed (per relay, at 25 C 77 F) Input current (during application of rated voltage) Approx. 0.7mA (Relay 9.2mA LED.5mA) Approx. 7.6mA (Relay.6mA LED 3.0mA) Input current (during application of rated input voltage) Allowable load current 3A Specification Item Specifications Contact data Expected life Contact rating (Resistive load) Max. switching power (Resistive load) Max. switching voltage Max. switching current Min. switching load (Reference value) Mechanical life Electrical life (Resistive load) 3 A 250 V AC, 3 A 30 V DC 750 VA (AC), 90 W (DC) 250 V AC, 30 V DC 3 A ma, 5 V DC Min. 2 0 7 (at 80 times/min.) Min. 3 0 : 3 A 250V AC, 3 A 30V DC Min. 0 5 : 2 A 250V AC, 2 A 30V DC Possible relays Maximum load voltage Continuous load current Possible relays Type Part No. (DC, AC peak value) (DC, AC peak value) Type Part No. DC only Maximum load voltage (DC, AC peak value) Approx. 0.0mA (Relay 7.0mA LED 3.0mA) Continuous load current (DC, AC peak value) AQZ02D 60V.80A AQZ202D 60V.350A AQZ05D 00V.5A AC, DC AQZ205D 00V 0.900A AQZ07D 200V 0.55A dual use AQZ207D 200V 0.50A AQZ0D 00V 0.30A AQZ20D 00V 0.225A Notes:. During -point simultaneous operation, the rating per point is also as shown above. 2. Please use a load current that is within the range of the data given below in REFERENCE DATA Load current vs. ambient temperature characteristics. 2 ASCTB369E 2070-T

SPECIFICATIONS RT-3 Unit relay/-point Terminal RT-3 Unit Relay/-point Terminal (PA-N Relay type) Item Specifications Condition Dielectric Between input and output 2,000 Vrms for min. strength Between different terminals (Initial) (between relays, both ways),500 Vrms for min. Insulation resistance (Initial) Min. 00 MΩ (Measurement at same location as Breakdown voltage section.) Using 500 V DC megger Vibration Destructive 0 to 55 Hz at double amplitude mm.039 inch In vertical, horizontal and longitudinal directions resistance Functional 0 to 55 Hz at double amplitude mm.039 inch In vertical, horizontal and longitudinal directions Shock Destructive Min. 96 m/s 2 In vertical, horizontal and longitudinal directions resistance Functional Min. 98 m/s 2 In vertical, horizontal and longitudinal directions Ambient temperature 20 to 55 C to 3 F Not freezing and condensing Condition Ambient humidity 35 to 85% R.H. Not condensing Storage temperature 30 to 80 C 22 to 76 F Not freezing and condensing Terminal screw fasten torque 0.3 to 0.5 N m Coil surge absorber Diode (A, 00V) Cross connection protecting diode A, inverse voltage 00 V Unit weight Approx. 00 g 3.53 oz Notes:. The value of breakdown voltage and insulation resistance is the initial one. 2. Condensing occurs when the unit relay is exposed to sudden temperature change in a high temperature and high humidity atmosphere. This may cause some troubles like insulation failure of the socket or the print circuit board. Take care under this condition. 3. Below 0 C 32 F, condensing water can freeze and cause socket contact failures and other problems. Take care under this condition. REFERENCE DATA. Maximum value for switching capacity (output) Per PA-N relay 0 Contact current, A DC resistive load AC resistive load 2. Load current vs. ambient temperature characteristics (DC only) Load current, A 2 AQZ02D AQZ05D AQZ07D AQZ0D 3. Load current vs. ambient temperature characteristics (AC/DC dual use) Load current, A 2 AQZ202D AQZ205D AQZ207D AQZ20D 0. 0 00 Contact voltage, V 000 20 0 0 0 20 30 0 50 60 32 50 68 86 0 22 0 Ambient temperature, C F 20 0 0 0 20 30 0 50 60 32 50 68 86 0 22 0 Ambient temperature, C F 3 ASCTB369E 2070-T

RT-3 Unit Relay/-point Terminal (PA-N Relay type) DIMENSIONS (mm inch). External dimensions 6-M3.8 terminal screw Input side 8..33 R2..083 2-M.57 screw mounting position 7.62.300 6.2.2 33 ±0.6.299 ±.02 2. Schematic Input terminal socket portion 3 5 6 9 LED 0 LED2 LED3 2 LED 7..29 67 ± 2.638 ±.039.2 0.3 0..65.02.00 R3.7.6 Output side 5 6 7 8 2 3 Output terminal socket portion With cover removed 5.5 ±0.6.27 ±.02 30.57 32±.260 ±.039 ±0.6.8 ±.02 3.8.53 Note: It is PA-N relay type. Cannot be equipped with PhotoMOS Power standard type relays. However, equipping with voltage sensitive type of PhotoMOS Power type is possible. The polarities of the output terminal socket are for the DC only type (equipped with AQZ0 D) 3. Mounting hole pattern General tolerance: ±0.3 ±.02 30 ±0..8 ±.00 2-.3 dia. or M 2-.69 dia. or M.57 ASCTB369E 2070-T

CAUTIONS FOR USE RT-3 UNIT RELAY -POINT TERMINAL. Never install modules (relays) into this product other than those designated. Doing so will cause malfunction, breakdown, and breakdown of the connected product. 2. If a unit is dropped be sure to check its external appearance and characteristics before using it. 3. The operation and return voltage values when equipped with PA-N relays are based on the relay terminals being face down. (RT-3 Unit relay (PA- N type), -point Terminal). Switching lifetime (PA-N relay) This characteristic depends on the relay and is effected by coil driving circuit, load type, activation frequency, activation phase, ambient conditions and other factors. Also, be especially careful of loads such as those listed below. ) When used for AC load-operating and the operating phase is synchronous, rocking and fusing can easily occur due to contact shifting. 2) Frequent switching under load condition When high frequently switched under load condition that can cause arc at the contacts, nitrogen and oxygen in the air is fused by the arc energy and HNO3 is formed. This can corrode metal materials. Three countermeasures for these are listed here. () Incorporate an arc-extinguishing circuit. (2) Lower the operating frequency (3) Lower the ambient humidity 5. Operating environment ) Keep the product as far way as possible from power cables, high tension equipment, power equipment, equipment with transmitting devices such as amateur radios, or equipment which generates a large switching surge. 2) The main unit is made of resin; therefore, do not use it in areas where it may come in contact with (or be exposed to) organic solvents such as gasoline, thinner, and alcohol, or strong alkaline substances such as ammonia and caustic soda. 3) Do not use the product in areas where it may be exposed to flammable gases, corrosive gases, excessive dust, or moisture, or areas where it may be subjected to strong vibration or shock. 6. Installing and removing the module ) Firmly insert the module into the socket with the terminals going in the direction of the blade receptacles. 2) The module can be easily removed using the removal key. () Insert the removal key into the socket slots. (2) Pull the removal key up to remove the module. (3) Slide the removal key off of the module. 7. Wiring and circuit configuration ) Perform wiring according to the internal schematic. Take care not to make any mistakes. In particular, with the RT-3 Unit relay (PA- N relay type) and -point terminal, be careful of the polarity on the output side when equipped with AQZ0 D (DC type). Also, with the RT-3 Unit relay (PhotoMOS Power type), be careful of the polarity on the output side of the DC type (RT3SP- V for type equipped with AQZ02). 2) We recommend the use of wirepressed terminals for connection to the terminal portion. Example of applicable wire-pressed terminal Company Name J.S.T. Mfg Co., Ltd. 3) When the load is inductive, limit spike voltages generated from the load to less than the maximum load voltage. Typical circuits are shown below. () Add a clamp diode to the load. Output terminals Part Name Applicable wirepressed terminal.25 to C3A 0.25 to.65mm 2 Load (2) Add an R-C snubber to the load. Output terminals Load (3) Add a varistor between the output terminals. Output terminals Load ) Even if spike voltages generated from the load are limited by a clamp diode or R-C snubber, inductances in long circuit wires will still create spike voltages. Keep wires as short as possible to minimize inductance. or DC only for AQZ0 D equipped type or DC only for AQZ0 D equipped type ASCTB37E 2070-T

CAUTIONS FOR USE 8. Installation ) Perform mounting hole cutout according to the panel cutout drawings. 2) When installing the unit on a DIN rail, use the DIN rail locking lever on the side of the unit. Installation is accomplished by simply fitting the unit onto the rail and pressing gently. DIN rail 2 Hook the holders on the unit over the DIN rail. First push in the DIN rail locking lever. DIN rail locking lever 3 Press the unit onto the DIN rail. 3) To remove the unit from the DIN rail, use a flat head screwdriver to pull out the DIN rail locking lever. 3 Remove the unit from the DIN rail. 9. Transporting and storage ) If the product is subjected to extreme vibration while being transported, the relays may become detached, the lead may become bent, and the unit may become damaged. Handle the carton and case with care. 2) If the product is stored in an extremely adverse environment, visible defects and deterioration of performance characteristics may result. We recommend the following storage conditions. Temperature: 5 to 30 C to 86 F Humidity: Max. 60% R.H. Environment: No hazardous substances such as sulfurous acid gases and little dust. 0. When equipped with PhotoMOS Power voltage drive type [RT-3 Unit relay (PA-N relay type), -point Terminal] Since the PhotoMOS Power voltage sensitive type does not require the current-controlling resistance on the input side, it can be used together with PA-N relays on RT-3 unit relay (PA-N relay type). When connecting PhotoMOS Power voltage sensitive types, since it will be a close connection, it will be necessary to be careful of load currents. Be sure to refer to the information given regarding Load currents vs ambient temperature characteristics in the precautions given for use of -point terminals. 2 Move the screwdriver in the direction of the arrows, and pull out the lever. Insert the tip of the flat head screwdriver into the slot in the DIN rail locking lever. TERMINAL BLOCK We recommend using wire-pressed terminals for connection to the terminal portion. Applicable electrical wire: 0.25 to.65 mm 2.0 to.065 inch Applicable wire-pressed terminals (mm inch) 5.8 max..228 max. 3 min..8 min. 5.8 max..228 max. 3 dia. min..8 dia. min..57.5 min..77 min..57.5 min..7 min. Company Name Part Name Part Name J.S.T. Mfg Co., Ltd..25 to C3A.25 to 3 NICHIFU.25Y to 3N.25 to 3 Nippon Tanshi Co., Ltd. VD.25 to 3L R.25 to 3 ACCESSORIES Short circuit plate for RT-3 Unit relay Use when you want to bridge terminals. < With insulator > < Without insulator > AY3802 External dimensions (mm inch) 28.7.30 7.62 ±0.3 5.8 ±0..300 ±.02.228 ±.00 3. ±0..22 ±.00 R 0.5.020 AY3803 External dimensions (mm inch) 28.7.30 7.62 ±0.3 5.8 ±0..300 ±.02.228 ±.00 3. ±0..22 ±.00 R 0.5.020 7.8.70 3.8.53 8 3 0 0.8.35 7.669 3.52 0.5 28.020.02.039 26.5.5 to 2.5.03 General tolerance: ±0.5 ±.020.059 to.098 General tolerance: ±0.5 ±.020 2 ASCTB37E 2070-T