Miniaturization of a Quasi-Servo Valve and Its Application to Positon Control of a Rubber Artificial Muscle with Built-in Sensor

Similar documents
Development of Flexible Pneumatic Cylinder with Backdrivability and Its Application

DEVELOPMENT OF OPTO-PNEUMATIC ON-OFF VALVE AND ITS APPLICATION TO POSITIONING

Available online at ScienceDirect. Procedia Computer Science 76 (2015 ) 2 8

2B34 DEVELOPMENT OF A HYDRAULIC PARALLEL LINK TYPE OF FORCE DISPLAY

Design and Control of a Hydraulic Servo System and Simulation Analysis

Position Control of a Hydraulic Servo System using PID Control

Biomimetic Design of Actuators, Sensors and Robots

Mechatronics Engineering and Automation Faculty of Engineering, Ain Shams University MCT-151, Spring 2015 Lab-4: Electric Actuators

Design and Controll of Haptic Glove with McKibben Pneumatic Muscle

Based on the ARM and PID Control Free Pendulum Balance System

Development of a Walking Support Robot with Velocity-based Mechanical Safety Devices*

Ch 5 Hardware Components for Automation

Shape Memory Alloy Actuator Controller Design for Tactile Displays

ScienceDirect. Equal coded digital hydraulic valve system improving tracking control with pulse frequency modulation

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers

Department of Mechanical Engineering, CEG Campus, Anna University, Chennai, India

Position Control of a Servopneumatic Actuator using Fuzzy Compensation

REDUCING THE STEADY-STATE ERROR BY TWO-STEP CURRENT INPUT FOR A FULL-DIGITAL PNEUMATIC MOTOR SPEED CONTROL

SMART SENSORS AND MEMS

Closed-Loop Speed Control, Proportional-Plus-Integral-Plus-Derivative Mode

Module 4 TEST SYSTEM Part 2. SHAKING TABLE CONTROLLER ASSOCIATED SOFTWARES Dr. J.C. QUEVAL, CEA/Saclay

Draw the symbol and state the applications of : 1) Push button switch 2) 3) Solenoid valve 4) Limit switch ( 1m each) Ans: 1) Push Button

Response characteristic of high-speed on/off valve with double voltage driving circuit

Electro-hydraulic Servo Valve Systems

Wearable Force Display Using a Particle Mechanical Constraint

Exercise 6. Open-Loop Speed Control EXERCISE OBJECTIVE

Omar E ROOD 1, Han-Sheng CHEN 2, Rodney L LARSON 3 And Richard F NOWAK 4 SUMMARY

POSITIONING OF PNEUMATIC ARTIFICIAL MUSCLE UNDER DIFFERENT TEMPERATURES József Sárosi 1 - Sándor Csikós 2

Vibration Control of Mechanical Suspension System Using Active Force Control

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

The Datasheet and Interfacing EE3376

Sensors and Sensing Motors, Encoders and Motor Control

Closed-Loop Position Control, Proportional Mode

Inverted Pendulum Swing Up Controller

Acceleration and Deceleration Control

signals and their parameterisation

Stationary Torque Replacement for Evaluation of Active Assistive Devices using Humanoid

An Improved Analytical Model for Efficiency Estimation in Design Optimization Studies of a Refrigerator Compressor

Self contained servo drive CLDP Technical data sheet

Sensors and Sensing Motors, Encoders and Motor Control

MEMS Real-Time Clocks: small footprint timekeeping. Paolo Frigerio November 15 th, 2018

ELG3336 Design of Mechatronics System

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

Kistler portable triaxial Force Plate

CONTROLLER DESIGN ON ARX MODEL OF ELECTRO-HYDRAULIC ACTUATOR

DEVELOPMENT OF STABILIZED AND HIGH SENSITIVE OPTICAL FI- BER ACOUSTIC EMISSION SYSTEM AND ITS APPLICATION

Fluid Mechanics-61341

Tactile Actuators Using SMA Micro-wires and the Generation of Texture Sensation from Images

Sonic Distance Sensors

Sensing self motion. Key points: Why robots need self-sensing Sensors for proprioception in biological systems in robot systems

ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT BY UTILZING SHEAR WAVES IN METAL PIPE

15-2 Nan-ei-cho, Tottori-shi JAPAN TEL FAX URL

Design of double loop-locked system for brush-less DC motor based on DSP

430. The Research System for Vibration Analysis in Domestic Installation Pipes

Introduction to Measurement Systems

System Inputs, Physical Modeling, and Time & Frequency Domains

Caterpillar Locomotion inspired Valveless Pneumatic Micropump using Single Teardrop-shaped Elastomeric Membrane

Synchronization Control Scheme for Hybrid Linear Actuator Based on One Common Position Sensor with Long Travel Range and Nanometer Resolution

CONTROL OF A PNEUMATIC SYSTEM WITH ADAPTIVE NEURAL NETWORK COMPENSATION SASAN TAGHIZADEH

Coils & Electronic Controls

Ultrasonic Level Transmitters (Optional Exercise)

RISE WINTER 2015 UNDERSTANDING AND TESTING SELF SENSING MCKIBBEN ARTIFICIAL MUSCLES

A New Glass-Ceramics for Tile-Glaze Application using PID Controller

3D Form Display with Shape Memory Alloy

ACTUATORS AND SENSORS. Joint actuating system. Servomotors. Sensors

MAE106 Laboratory Exercises Lab # 5 - PD Control of DC motor position

11th Japan International SAMPE Symposium & Exhibition JISSE-11. Call for Papers. Deadline for Submission of Abstract: May 31, 2009

DC motor control using arduino

Practical controller design for ultra-precision positioning of stages with a pneumatic artificial muscle actuator

DIGITAL CONTROL OF ELECTRO-HYDRAULIC STEERING TEST BENCH

Electrohydraulic Actuator Type PVEP / PVEP-F

Electronics Design Laboratory Lecture #11. ECEN 2270 Electronics Design Laboratory

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

SONOFILE SH Ultrasonic cutter Oscillator. Oscillator SH-8700RR/HG-110/SF-8541RR SF-3110/SF-8500RR/SF-3140

VOICE COIL ACTUATOR (VCA) DEVELOPER S KIT Complete VCA and Driver Kit for Custom Actuation System

11 1. H Tomori, Y Midorikawa and T Nakamura, Vibration control of an artificial muscle manipulator with a magnetorheological fluid brake, Journal of

Robot Sensors Introduction to Robotics Lecture Handout September 20, H. Harry Asada Massachusetts Institute of Technology

Fatigue testing. Fatigue design

Introduction. ELCT903, Sensor Technology Electronics and Electrical Engineering Department 1. Dr.-Eng. Hisham El-Sherif

White Paper. Even Without Power You can count on it

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental

ANTI-WINDUP SCHEME FOR PRACTICAL CONTROL OF POSITIONING SYSTEMS

MS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM

Modeling and Control of Mold Oscillation

WhitePaper. How To Substantially Reduce Encoder Cost While Gaining Functionality With Multi-Turn Rotary Position Sensors

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENT ABSTRACT ABSTRAK

Lab Exercise 9: Stepper and Servo Motors

Paul Schafbuch. Senior Research Engineer Fisher Controls International, Inc.

CSE 3215 Embedded Systems Laboratory Lab 5 Digital Control System

Group Robots Forming a Mechanical Structure - Development of slide motion mechanism and estimation of energy consumption of the structural formation -

Modelling and Numerical Simulation of Parametric Resonance Phenomenon in Vibrating Screen

FLUTTER CONTROL OF WIND TUNNEL MODEL USING A SINGLE ELEMENT OF PIEZO-CERAMIC ACTUATOR

Extended Performance of Hybrid Actuators 1

Ultrasonic Controller/Sensor. Technical Information

Applications of Piezoelectric Actuator

UNIVERSITY OF JORDAN Mechatronics Engineering Department Measurements & Control Lab Experiment no.1 DC Servo Motor

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

Robotic Vehicle Design

MEMS-based Micro Coriolis mass flow sensor

Available online at ScienceDirect. Procedia Technology 20 (2015 )

Transcription:

MATEC Web of Conferences 82, Miniaturization of a Quasi-Servo Valve and Its Application to Positon Control of a Rubber Artificial Muscle with Built-in Sensor Yoshinori Moriwake 1, Shujiro Dohta 1,a, Tetsuya Akagi 1 and So Shimooka 1 1 Okayama University of Science, 1-1, Ridai-cho, Kita-ku, Okayama, Japan Abstract. Nowadays, the care and welfare pneumatic devices to support a nursing care and a self-reliance of the elderly and the disabled are actively researched and developed by many researchers. These wearable devices require many actuators and control valves for multi degrees of freedom. The total weight and volume of the wearable devices increases according to the degree of freedom. Our final goal is to develop a compact wearable actuator with built-in sensor, controller and control valve and to apply it to a wearable assisted device. In our previous study, a small-sized quasi-servo valve which consists of two on/off control valves and an embedded controller was developed. In this study, the quasi-servo valve composing of much smaller-sized (40% in mass, 42% in volume) on/off valves is proposed and tested. In addition, the rubber artificial muscle with an ultrasonic sensor as a built-in displacement sensor is proposed and a position control of the muscle is carried out using the tested tiny valve and built-in sensor. As a result, it was confirmed that the position control of the muscle can be realized using the tested ultrasonic sensor. 1 Introduction Today, the care and welfare pneumatic devices to support a nursing care and a self-reliance of the elderly and the disabled are actively researched and developed by many researchers [1] to [5]. These wearable devices require many actuators and control valves for multi degrees of freedom and precise control performance of the device. The total weight and volume of the wearable devices increases according to the degree of freedom. Therefore, we aim to develop a compact and low-cost servo valve and a wearable actuator built-in sensor. In our previous studies [6] to [8], a small-sized, light-weight and inexpensive pressure control type quasi-servo valve which consists of two on/off control valves using a low-cost embedded controller and a pressure transducer was proposed and tested. In this paper, a quasi-servo valve by using the much smaller, lighter and inexpensive on/off control valves is produced and tested. In addition, as an application of the tested valve, a position control of a rubber artificial muscle is carried out by using the tested quasi-servo valve and an ultrasonic sensor as a displacement sensor. The ultrasonic sensor is installed in the rubber artificial muscle to develop a compact wearable actuator with built-in sensor. The control performance of the muscle is shown and the usefulness of the tested built-in sensor is discussed. a Corresponding author : dohta@are.ous.ac.jp The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

2 Quasi-Servo Valve Figures 1 and 2 show the schematic diagram and the view of the quasi-servo valve, respectively. The valve consists of two on/off control valves (SMC Co. Ltd., S070C-SDG-32) whose both output ports are connected to each other. One valve is used as a switching valve to supply or exhaust, and the other is used as a PWM control valve that can adjust output flow rate like a variable fluid resistance [6]. The size of the on/off valve is 12 33 7mm, and the mass is only 6g. The previous on/off valve (Koganei Co. Ltd., G010HE-1) was 33 20 10mm, and the mass was 15g [6]. The proposed valve is 58% smaller and 60% lighter than the previous valve. The maximum output flow rate is 15 liter/min at the supply pressure of 500kPa. Figure 1. Schematic diagram of quasi-servo valve. Figure 2. View of quasi-servo valve. 3 Artificial Rubber Muscle with Built-In Displacement Sensor As a built-in displacement sensor of the rubber artificial muscle, an ultrasonic sensor was selected, because the ultrasonic sensor has many advantages that it can measure the displacement by noncontacting and is a low-cost sensor. Figures 3 and 4 show a schematic diagram of the system and a view of a rubber artificial muscle (FESTO Co. Ltd., MXAM-10-AA) with a built-in sensor and an embedded controller, respectively. The original length of rubber artificial muscle is 250 mm and the inner diameter is 10 mm. The stroke of the muscle is about 50mm in the case when the supply pressure of 500 kpa is applied. The tested ultrasonic sensor is rebuilt by using the sensor on the market (Parallax Inc. Ltd., 28015). The transmitter and receiver on the sensor are changed smaller ones as shown in Fig.8 on the right side (the transmitter: Nippon Ceramic Co. Ltd., T4008A1) and on the left side (the receiver: Nippon Ceramic Co. Ltd., R4008A1), respectively. The measuring principle is well known as follows. The distance is estimated by the time until the ultrasonic wave reaches at the receiver from the transmitter. This time is counted by an embedded controller (Renesas Co. Ltd., SH7125). The distance between the transmitter and the receiver can be obtained by using the velocity of sound and the time interval; counting value. Figure 3. Schematic diagram of artificial muscle with built-in sensor. 2

Figure 4. View of rubber artificial muscle with built-in sensor. Figure 5 shows the relation between the counting value and the measured length of the rubber artificial muscle. The counting value was obtained by the tested built-in ultrasonic sensor and the measured length was obtained by the potentiometer. In the experiment, the artificial muscle was pressurized from 200 to 500 kpa every 50 kpa. From Fig.5, it can be seen that the relation between the sensor output and the length of the muscle is linear even if the rubber muscle is pressurized. This result means that the tested ultrasonic sensor is useful as a built-in displacement sensor of the rubber artificial muscle. From the result, the relation between the length L m [mm] and the counting value C m [-] can be expressed by the following equation. L 0.197C 129 (1) m m Figure 5. Relation between applied pressure and length of muscle. 4 Position Control of Artificial Rubber Muscle with Built-In Sensor Using Quasi-Servo Valve Figures 6 and 7 show the schematic diagram and the view of the position control system of the tested rubber artificial muscle with built-in sensor, respectively. The control system consists of the tested quasi-servo valve, the tested rubber artificial muscle and an embedded controller. In addition, the potentiometer is connected with the tested muscle in order to measure the true displacement as a monitor. The position control is done as follows. First, the embedded controller counts the time of the output signal from the tested ultrasonic sensor through I/O port. The embedded controller also calculates the length of the muscle from the counted value mentioned above. The error between the measured displacement and the reference displacement is calculated by the controller and the control input for the quasi-servo valve is also calculated based on a control scheme. Finally, the control input is applied to the quasi-servo valve as PWM signal and on/off signal for two on/off valve in quasiservo valve. 3

Figure 6. Schematic diagram of position control system. Figure 7. View of the position control system. Figure 8 shows the transient response of displacement of the rubber artificial muscle with built-in displacement sensor. In the experiment, the desired sinusoidal position with the offset of 25mm, the amplitude of 10mm and the frequency of 0.1Hz was applied to the control system as a reference. As a feedback displacement signal, the output signal from the potentiometer was used. The supply pressure is 500kPa. PD control scheme expressed by following equations was used. u d K e K e (2) p c d c u 20 (3) u d Where u d, K p (= 65 %/mm), e c, K d (= 35 %/mm), e and u mean the control input, the proportional c gain, the error from the reference, the derivative gain, difference of error and input duty ratio to the PWM valve, respectively. As mentioned above, the switching valve switches to supply if u d > 0, and to exhaust in other case. In Fig.8, the blue, red and green lines show the reference displacement, the true displacement measured by potentiometer and the measured displacement by using ultrasonic sensor, respectively. From Fig.8, it can be observed that the measured displacement by a potentiometer can track the reference displacement and that the measured displacement using the ultrasonic sensor is a little larger than the true displacement while the displacement is increasing: the air is being supplied. This is because the velocity of the sound wave is increased by the air supply as shown in Fig.6, and the length of the muscle is estimated shorter and consequently the contracted displacement becomes larger. Figure 9 shows the transient response of the displacement of the rubber muscle using the signal from ultrasonic sensor as a feedback signal. From Fig.9, it can be found that the measured displacement using ultrasonic sensor can track well the reference displacement. However, the displacement is a little larger than the true displacement while the displacement is 4

increasing and the displacement is much larger than the true displacement when the displacement is decreasing: the air is being exhausted. This phenomenon can be explained as same as mentioned above. But, its difference is larger than the case when the air is supplied. The investigation for this phenomenon and its compensation for the position control are our future works. However, it is concluded that the tested ultrasonic sensor can be used as a built-in displacement sensor for the rubber artificial muscle. Figure 8. Position control using the potentiometer as a feedback signal. Figure 9. Position control using the ultrasonic sensor as a feedback signal. 5 Conclusions This study can be summarized as follows. The new small-sized quasi-servo valve using a tiny on/off valve which is 58% smaller and 60% lighter than previous one was produced and tested. In addition, the rubber artificial muscle using the built-in ultrasonic sensor was proposed and tested. The measuring system of the tested sensor using the embedded controller was also proposed and tested. In order to confirm the effectiveness of the tested sensor, the relation between the counting value in the tested sensor and true displacement measured by the potentiometer was investigated. And the position control system that consists of the rubber artificial muscle with built-in displacement sensor, the small-sized quasi-servo valve and an embedded controller was proposed and tested. As a result, it was confirmed that the ultrasonic sensor could be used as a built-in sensor of the rubber artificial muscle. Acknowledgements This research was supported by the Ministry of Education, Culture, Sports, Science and Technology of Japan through a Financial Assistance Program for QOL Innovative Research (2012-2016). 5

References 1. T. Noritsugu, M. Takaiwa and D. Sasaki, Development of Power Assist Wear Using Pneumatic Rubber Artificial Muscles, Journal of Robotics and Mechatronics, 21, 607-613 (2009) 2. N. Hogan and H. I. Krebs, Interactive robots for neuro-rehabilitation, Restorative Neurology and Neuroscience, 22, 349-358 (2004) 3. H. Kobayashi, T. Shiban and Y. Ishida,Realization of all 7 motions for the upper limb by a muscle suit, Journal of Robotics and Mechatronics, 16, 504-512 (2004) 4. M. Ishii, K. Yamamoto and K. Hyodo, Stand-Alone Wearable Power Suit-Development and Availability, Journal of Robotics and Mechatronics, 17, 5, 575-583 (2005) 5. Y. Nagata ed., Soft Actuators -Forefront of Development, NTS Ltd., 291-335 (2004). 6. F. Zhao,S. Dohta and T. Akagi, Development and Analysis of Small-sized Quasi-servo valves for Flexible Bending Actuator, Tansactions of the JSME (C), 76, 772, 3665-3671, (2010) 7. Y. Moriwake, T. Akagi, S. Dohta and F. Zhao, Development of low-cost pressure control type quasi-servo valve using embedded controller, Journal of Procedia Engineering, 41, 493-500 (2012) 8. S. Shimooka, S. Dohta, T. Akagi, Y. Moriwake and F. Zhao, Estimation of Pressure Control Performance in Low-Cost Quasi-Servo Valve Using Embedded Controller, Lecture Notes in Electrical Engineering 293, Springer, 1, 359-366 (2014) 6