CHAPTER-IV EXPERIMENTAL AND SIMULATION PROGRAM

Similar documents
SHUNT ACTIVE POWER FILTER

Power Quality enhancement of a distribution line with DSTATCOM

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

6. HARDWARE PROTOTYPE AND EXPERIMENTAL RESULTS

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

CHAPTER 2 DESIGN AND MODELING OF POSITIVE BUCK BOOST CONVERTER WITH CASCADED BUCK BOOST CONVERTER

Chapter-5 MODELING OF UNIFIED POWER FLOW CONTROLLER. There are a number of FACTS devices that control power system

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

To Study The MATLAB Simulation Of A Single Phase STATCOM And Transmission Line

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

CHAPTER 7 HARDWARE IMPLEMENTATION

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

Investigation of D-Statcom Operation in Electric Distribution System

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Designing Of Distributed Power-Flow Controller

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Chapter 2 Shunt Active Power Filter

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Power flow improvement using Static Synchronous Series Compensator (SSSC)

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

CHAPTER 3 H BRIDGE BASED DVR SYSTEM

Performance of DVR & Distribution STATCOM in Power Systems

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

The Influence of Thyristor Controlled Phase Shifting Transformer on Balance Fault Analysis

CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

Voltage Source Converter Modelling

Power Factor Improvement Using Thyristor Switched Capacitor Using Microcontroller Kacholiya Saurabh 1, Phapale Sudhir 2, Satpute Yuvraj 3, Kale.S.

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: [Chakradhar et al., 3(6): June, 2014] ISSN:

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Modeling and Simulation of STATCOM

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

CHAPTER 3 MODIFIED FULL BRIDGE ZERO VOLTAGE SWITCHING DC-DC CONVERTER

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Power Factor Correction of LED Drivers with Third Port Energy Storage

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Chapter 10: Compensation of Power Transmission Systems

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

MICROCONTROLLER BASED BOOST PID MUNAJAH BINTI MOHD RUBAEE

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Development of a Single-Phase PWM AC Controller

CHAPTER 4 PI CONTROLLER BASED LCL RESONANT CONVERTER

Volume I Issue VI 2012 September-2012 ISSN

Voltage Control and Power System Stability Enhancement using UPFC

Voltage Improvement Using SHUNT FACTs Devices: STATCOM

Experiment DC-DC converter

Power Quality improvement of a three phase four wire system using UPQC

CHAPTER-5 DESIGN OF DIRECT TORQUE CONTROLLED INDUCTION MOTOR DRIVE

CHAPTER 2 VSI FED INDUCTION MOTOR DRIVE

BLDC Motor Speed Control and PFC Using Isolated Zeta Converter

Transient Stability Improvement Of IEEE 9 Bus System With Shunt FACTS Device STATCOM

CHAPTER 2 PHASE SHIFTED SERIES RESONANT DC TO DC CONVERTER

Design of Z-Source Inverter for Voltage Boost Application

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs

CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM

Experimental Verification and Matlab Simulation of UPFC for Power Quality Improvement

Study on Voltage Controller of Self-Excited Induction Generator Using Controlled Shunt Capacitor, SVC Magnetic Energy Recovery Switch

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

A Three-Phase AC-AC Buck-Boost Converter using Impedance Network

Power Quality Compensation by using UPFC

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Digital Combination of Buck and Boost Converters to Control a Positive Buck Boost Converter and Improve the Output Transients

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Implementation and Design of Advanced DC/AC Inverter for Renewable Energy

CHAPTER 3 MAXIMUM POWER TRANSFER THEOREM BASED MPPT FOR STANDALONE PV SYSTEM

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Lecture 4 ECEN 4517/5517

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

Power quality improvement and ripple cancellation in zeta converters

Mitigation of Power Quality Problems Using DVR in Distribution Network for Welding Load

MITIGATION OF VOLTAGE SAG AND SWELL FOR POWER QUALITY IMPROVEMENT USING DISTRIBUTED POWER FLOW CONTROLLER

Power Factor Improvement Using Static VAR Compensator

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Hardware Implementation of Two-Phase Bridgeless Interleaved Boost Converter for Power Factor Correction

A NEW SINGLE STAGE THREE LEVEL ISOLATED PFC CONVERTER FOR LOW POWER APPLICATIONS

MITIGATION OF VOLTAGE SAGS/SWELLS USING DYNAMIC VOLTAGE RESTORER (DVR)

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

Transcription:

49 CHAPTER-IV EXPERIMENTAL AND SIMULATION PROGRAM 4.0 INTRODUCTION This chapter covers in detail the experimental set up of proposed Z source Matrix (ZSMC) based UPFC and compares with a lab scale model of Conventional Voltage Source Converter (VSC-UPFC) based UPFC. The experimental results have been verified with the simulation results developed in MATLAB-Simulink. The study is aimed at identifying better performance. This chapter covers the experimental test programs in the following sections as following. Section 4.1 Simulation and Analysis of a 3 Ph conventional VSC- UPFC in IEEE 5 bus test system using MATLAB-Simulink. Section 4.2 Construction of a 1 Ph, 2 bus Lab Scale Model of conventional VSC-UPFC. Section 4.3 Simulation and Analysis of a 1 Ph ZSMC in PSPICE environment. Section 4.4 Simulation and Analysis of a 1 Ph 2 bus ZSMC as UPFC in MATLAB-Simulink. Section 4.5 Construction of a 1 Ph, 2 bus Lab Scale Model of the proposed ZSMC-UPFC. Section 4.6 Summary and discussion on the experimental and simulation results.

50 4.1 MATLAB -SIMULINK MODEL OF CONVENTIONAL VSC - UPFC A standard IEEE 5 bus test system [Stagg and El-Abiad 1968 84 ] is modeled and simulated in MATLAB-Simulink consisting of two generator buses and three load buses with UPFC installed in the line 7 between buses 4 and 5 is depicted clearly in the Fig 4.1 and Fig 4.2. The generators, transmission lines and the loads are rated at 1.8 KV (Peak 2.5 KV). A three phase UPFC with two voltage source converters to serve as STATCOM and SSSC is developed using MOSFETS as switching devices at power line frequency, 50 HZ. The dc link capacitor rated at 200 m F and the two transformers shunt and series at 1800 V/230 V are connected to the transmission line. The bus data and line data along with the simulation parameters of UPFC are tabulated in Tables 4.1, 4.2 and 4.3. The actual values of voltage, current, real power and reactive power at all buses are obtained using VI and PQ Simulink Blocks. This is similar to measurements taken using PMU s and RTU s for state estimation. Voltage magnitude, voltage angle, and real and reactive current are measured by PMU while the injection and flow of real and reactive power are monitored through RTU. The power injection and flow measurements are employed to obtain the control parameters of FACTS controllers in a very short time span, and, therefore, avoid conventional state estimation procedures for arriving at the control

51 settings of the UPFC under a given operating condition, while satisfying a specified control objective [Phadke, 1993 83 ] Table 4.1 Bus Data S.No Bus Type V Pd Qd Pg Qg (p.u) (MW) (MVAR) (MW) (MVAR) 1 Slack bus1 1.0 0 0 6.0 5.0 2 Genr bus 2 1.0 0 0 6.5 6.0 3 Load bus 3 1.0 6.75 3.25 0 0 4 Load bus 4 1.0 0.50 2.0 0 0 5 Load bus 5 1.0 1.70 2.0 0 0 Table 4.2 Line Data Transmission line Nl Nr R(p.u) X(p.u) 1 1 2 0.02 0.06 2 1 3 0.02 0.24 3 2 3 0.024 0.18 4 2 4 0.024 0.18 5 2 5 0.02 0.12 6 3 4 0.02 0.03 7 4 5 0.02 0.24 BUS DATA Base MVA : 100MVA Base KV : 1.8KV

52 Table 4.3 Simulation Parameters of UPFC S.No Component Ratings 1. Shunt Transformer 1800/230 V 2. Series Transformer 230/1800 V 3. DC Link Capacitor 200 m F 4. Converter Switches - MOSFETS Vdss= 240V Operating frequency- 50 Hz Switching frequency-1mhz 5. PI Controller Kp=2, Ki=200 Fig 4.1 MATLAB-Simulink Model of UPFC

53 L3 3phase Fault1 Discrete, Ts = 5e-005 s powergui A B C A B C Conn1 aa aa aa A a A L4 Scope 1 Scope 2 Conn2 bb bb bb B b B Vabc1 Vabc Conn3 G1 1.8 KV 6 MW 5 MVAR T8 cc B1 T2 cc B3 T4 cc B4 C c C Three-Phase Breaker From10 Iabc1 From11 PQ Iabc PQ1 Scope 11 Vabc2 Iabc2 Vabc PQ Iabc Scope 22 PQ2 In1 T3 T5 In2 Conn1 Conn2 Out1 T6 Conn3 Conn4 Conn5 Out2 Conn6 Conn7 Conn1 Conn2 aa bb T7 aa bb A B L5 Conn8 Conn9 Conn10 In1 UPFC Out1 Out2 Out3 Vabc3 From14 Iabc3 From15 Scope 3 Vabc PQ Iabc PQ3 Scope 33 Vabc4 From16 Iabc4 From17 Scope 4 Vabc PQ Iabc PQ4 Scope 44 Conn3 cc cc C Conn1 Out3 G2 1.8RR KV 6.5 MW 6 MVAR T9 B2 T1 + - v B5 Conn3 Conn2 Conn4 Conn5 Conn6 PI CONTROLLER AND dq BLOCK VM Scope10 Scope 5 Vabc5 Vabc From18 PQ Iabc5 Iabc From19 PQ5 Scope 55R Fig 4.2 IEEE 5 Test Bus with UPFC - Simulink Block Diagram

54 4.1.1 Control Scheme of VSC-UPFC A closed loop control using a PI controller is incorporated to operate at the shunt end as STATCOM in the reactive control mode and at the series end as SSSC in automatic power flow control mode by controlling the magnitude and angle of the series injected voltage. Refer Fig 4.3. The three phase voltages and currents are sensed and transformed into two phase quantities using Parks Transformation which gives d-q current and voltage to the controller. The actual real and reactive power values are fed into the controller from PQ blocks. The reference inputs P ref and Q ref fed into the controller are compared with the actual values. A phase locked loop (PLL) is used to determine the instantaneous angle of the line voltage. The current component I d and I q is used to determine the relative phase angle with respect to the voltage. At the SSSC end SSSC is operated in Automatic Power Flow Mode at the series end by controlling the magnitude and angle of the series injected voltage. Hence at the series end SSSC, real power mismatch and reactive power is compensated. The reference power inputs are fed into the controller. The actual line voltage, current, real power and reactive power are measured using VI and PQ blocks. These actual powers are compared with the reference powers. p /2 is added or subtracted to injected voltage with respect to line current emulates inductive or capacitive compensation whichever

55 is required at SSSC end. This actually decreases/increases the magnitude of the bus voltage at that point, thereby compensating the reactive power. As for real power mismatch, phase shift control which controls the phase angle of the injected voltage is applied. For extra real and reactive power, voltage magnitude is increased by pulse width modulation technique. The SSSC pulse generator thus generates the compensating voltage. At the STATCOM end The STATCOM controller at the shunt end generates the required output voltage magnitude and phase angle in synchronism with the ac sinusoidal system. The reactive power mismatch is adjusted through this control. The reactive current reference I q is set to zero for unity power factor. The real current reference I d is set with respect to instantaneous real power reference, P = 3/2 V di d. For additional reactive power, the STATCOM controller increases the modulation index.

56 Fig 4.3 Simulation circuit of PI Controller and dq Transformation Block

57 4.1.2 Simulation Results of Conventional VSC-UPFC A power flow study is conducted on the 5 bus test system. The loads are applied at three load buses and the actual values of voltage and power at all buses (similar to power flow like results). Based on bus voltage magnitude obtained from the above measured results, bus 4 is identified as the most critical bus. The UPFC is chosen to be located between bus 4 and bus 5 on line 7. Similar load study is conducted with UPFC to illustrate its superior performance. To illustrate the results further, a load variation study with UPFC is carried out at bus 4. For studying the UPFC s effect on transient stability, a sudden peak load of 148% i.e. 0.75 MW active load and 2.96 MVAR reactive load are applied at 0.2 seconds through a circuit breaker. The actual value of voltage and power at all buses for peak load is tabulated in Table 4.4. The output voltage obtained at STATCOM and SSSS are shown in Fig 4.4 and 4.5. A small phase angle difference is noted between the line voltage and current at the shunt end as shown in the power factor angle diagram Fig 4.6. Thus the line current is nearly in phase with the input voltage (p.f 0.95 lead) clearly illustrates the STATCOM s role as a reactive power compensator. The STATCOM has absorbed a small amount of real power from the ac transmission line system. The series injected voltage by SSSC is almost in quadrature lag with the transmission line current operated in capacitive mode as shown in Fig 4.7.

58 The transmission supply voltage is seen to have decreased to 0.66 p.u i.e. 1.26 kv (Peak Volt 1.78 kv) as shown in the Table 4.4 and Fig 4.8 with application of peak load. The three phase line currents are almost in phase with supply voltage after UPFC is connected as shown in Fig 4.9. This has confirmed that the UPFC has the capability of transient stability. The results clearly illustrate the superior performance of UPFC with respect to voltage enhancement, followed by increase in real power and reactive power flow at bus 4. Fig 4.4 STATCOM (Rectifier) Output Voltage

59 Fig 4.5 SSSC (Inverter) Output Voltage Fig 4.6 At STATCOM end - Power Factor

60 Fig 4.7 SSSC Injected Voltage and Line Current (Capacitive mode) Fig 4.8 Transmission Line Voltage during Peak Load without UPFC

61 Fig 4.9 Transmission Line Voltage and Current in Phase with UPFC Table 4.4 Bus Voltage and Power - VI and PQ Simulink Blocks Bus Type of Bus Without UPFC With UPFC No V (pu) P (MW) Q (MVAR) V (pu) P (MW) Q (MVAR) 1 Slack bus 1 3.94 4.74 1 4.8 4.23 2 Generator 0.95 6.5 4.15 1 6.5 4.00 Bus 3 Load Bus 0.85 6.75 3.25 0.90 6.75 3.25 4 Load Bus 0.66 0.75 2.96 1.0 0.75 2.96 5 Load Bus 0.86 1.7 2.0 0.89 1.7 2.0

62 4.1.3 Summary and Discussion 1) Enhanced voltage profile at all buses is observed with UPFC installed. 2) The real power generation at bus 1 has shown an increase to meet the increased peak load at bus 4. 3) The reactive power generation at bus1 and bus 2 has shown a decrease clearly demonstrating that UPFC has generated the required reactive power based on its VA rating to meet the increased peak load at bus 4. 4) The real power in the line 4-5 with UPFC connected has shown a two fold increase from 0.2 MW to 0.4 MW. 5) The reactive power in the line 4-5 with UPFC has increased from 1 MVAR to 2 MVAR. 4.2 EXPERIMENTAL MODEL OF CONVENTIONAL VSC - UPFC. A conventional experimental model of single phase UPFC is constructed using two voltage source converters connected through a dc link capacitor with a shunt transformer and a series transformer inserted at the two ends of the transmission line. The hardware specifications for the prototype model are tabulated in Table 4.5. MOSFETS are used as switching devices. A resistor and an inductor coil rated at 15 ohms and 3.33 ohms is used to represent a radial distribution like line of X/R ratio 0.22. A 24 V voltage source is connected at the sending end through a step down transformer 230/24V. An induction motor rated at 24V, 1.2A is connected at the

63 load for studying the effect of UPFC. The capacitor is usually designed for 10% of the nominal voltage. The SSSC converter at the other end injects the synchronized voltage through the series transformer with the required phase shift into the line. The Programmable Interface Controller (PIC) is programmed to generate PWM signals to trigger the MOSFETS through the gate driver circuit. The comparator provides a reference signal to generate trigger signals in synchronization with the supply voltage. The program starts triggering when the zero crossing of the ac supply is detected through ZCD. The program generates a pulsed signal at 50 HZ. A delay is obtained at the output of the inverter by adding a delay instruction before the start of the trigger. As the phase shift θ is increased introducing the time delay, the output voltage shifts with respect to supply voltage. Filters are added to get a smooth sinusoidal voltage to synchronize with ac input voltage. The photo shot of the entire hardware set up along with the block diagram is shown in Fig 4.10 and Fig 4.11

64 Fig 4.10 Hardware Block Diagram of UPFC Fig 4.11 Complete Experimental set up of UPFC. 4.2.1 Experimental Results of Conventional VSC-UPFC The experimental results at the STATCOM, SSSC, and the final output voltage of UPFC synchronized with input voltage at 24 V through series step up transformer are as shown in Fig 4.12 to Fig 4.15.

65 Fig 4.12 Rectifier Module (STATCOM) Output-CRO Fig 4.13 Inverter Module (SSSC) Output-CRO Fig 4.14 Output voltage without UPFC-CRO

66 Fig 4.15 Output voltage with UPFC-CRO Table 4.5 Conventional VSC-UPFC -Hardware Specifications S.No Name of Component Rating 1 Transmission line Input = 230/24V, R = 15 ohms, X = 3.33 ohms Load = 1 Ph Induction Motor, 24V, 1.2A Step Down Transformer = 230/24V 2 Shunt 230/24V transformer 3 Series 24/230V transformer 4 Converter Power MOSFET IRF 460 Circuit 5 Driver circuit Transistor (2N222A, CK100) 6 Micro Controller PIC 16F877A 7 DC Link Capacitor 10 m F 4.3 PROPOSED ZSMC BASED UPFC. This chapter explains the design, control strategy and the transfer voltage gain of the prototype Z source Matrix Converter based UPFC model (ZSMC) verified by simulation analysis in PSPICE and MATLAB-Simulink environment. PSPICE (Simulation Program with Integrated Circuit Emphasis) is a general purpose program suitable

67 for simulating electronic circuits. Till recently PSPICE is compatible only on main frame computers. Hence the operation modes, its output voltages at different amplitudes and frequency are simulated in PSPICE. The limitations of PSPICE are the program statements have to be edited for every change of component value. Hence a power flow study for different variations of load using UPFC has been simulated in the powerful MATLAB-Simulink environment. An investigation of its capabilities and characteristics as a unified power flow controller (UPFC) is presented in detail. The novel model is obtained by coupling the Z source network with the PWM based matrix converter. This ac to ac converter can buck and boost voltage with step changed frequency. The pulse width modulation strategy provides the near sinusoidal voltage waveform with the required phase shift. The Z source topology provides the extra open circuit zero state when all the switches are turned off and the output terminals of the Z source are open circuited. This attributes for the unique buck boost capability. 4.3.1 PSPICE Simulation Model of ZSMC In order to study the principle and mode of operation of ZSMC a single phase matrix converter with Z source circuit, fed to a resistive load is simulated in PSPICE for different frequencies and different voltage magnitude bucked and boosted. It has a bridge type configuration with four MOSFET switches and combination of diodes

68 connected in anti parallel for facilitating independent control of current in both directions as depicted in Fig 4.16. The Z source topology and the triggering pulse circuit are as shown in Fig 4.17A and Fig 4.17B. At the input side of the matrix converter, LC input filter, one buck boost MOSFET bidirectional switch, and the Z source impedance circuit are employed. The LC filter is used to reduce the ripples in the input current. The Z source impedance is a combination of two inductors L1 and L2 and two capacitors C1 and C2 serving as energy storage elements. The simulation parameters are given in detail in Table 4.6. Since the switching frequency 1 khz in the Z source circuit is much higher than the matrix converter frequency 50 Hz, the size of inductors and capacitors is very small. The amplitude of the output voltage is controlled by duty ratio of the matrix converter switches and the boost factor in the Z source circuit. The boost factor is controlled by the duty cycle of the shoot through state over the non shoot through active state. During the shoot through state, only zero voltage is impressed on the matrix converter. The output frequency is changed by the switching strategy.

69 D1 D3 D9 D11 G1M1 G3M3 IRF840 IRF840 D2 MUR150 D4 D10 MUR150 D12 V+ S1 S3 P R5 N 500k V+ V- V- D5 D7 D13 D15 G4M2 G2M4 IRF840 IRF840 D6 MUR150 D8 D14 MUR150 D16 S4 S2 0 Fig 4.16 Matrix Converter simulated in PSPICE D17 D19 V6 VOFF = 0 VAMPL = 230V FREQ = 50H L1 1 2 1uH V1 = 0 V2 = 5 D18 TD = 0 TR = 1n TF = 1n PW = 0 PER = 20m V7 M5 D20 C2.0001u L2 1 2.1uh C3.0001u P C1 10u L3 2 1 N Fig 4.17A Z Source Network Simulated in PSPICE.1uh

70 DSTM1 S4 A[0..3] Implementation = MATRIX A0 U1 MCT2E V1 S1 0 12 R1 1k G1 A1 U2 MCT2E V2 S2 0 12 R2 1k G2 A2 U3 MCT2E V3 S3 0 12 R3 1k A3 U4 MCT2E V4 G3 S4 0 12 R4 1k G4 Fig 4.17B PSPICE Simulation of Triggering Pulse Circuit Table 4.6 PSICE Simulation Parameters of ZSMC S.No Components Ratings 1 Triggering Pulse Circuit for 4 switches Voltage - V1,V2,V3,V4 = 12 V Resistance - R1.R2,R3,R4 =1K ohm 2 Z source Network Input side Input Voltage = 230 Volts Inductance L1,L2,L3 = 10 µh Capacitance C1 = 10 µf, C2, C3 = 0.0001 µf Buck-Boost Switch side MOSFET- 1 No Switching Frequency Trigger voltage T R- Rise Time T F Fall Time = 1 khz = 24V =1 ns =1 ns 3 1 PH Matrix Converter MOSFETS = 4 Nos Diode = 4Nos Pulse width = 20 ms (50 HZ) Resistance load = 500 K ohms Inductance load =10 mh

71 4.3.1.1 Modes of Operations of Matrix Converter Fig 4.18 Mode 1 In this mode D1, GM1, D4, load R1, D14, GM4, D18 conduct. The input voltage appears across the load as output. Fig 4.19 Mode 2 In this mode D10, GM3, D12, load R1, D6, GM2, D7 conduct. The polarity of the output voltage is just opposite to the output obtained in the previous mode.

72 Fig 4.20 Mode 3 In this mode D5, GM2, D8, load R1, D9, GM3, D13 conduct. The polarity of the output voltage is just opposite to the output obtained in the previous mode. Fig 4.21 Mode 4 In this mode D15, GM4, D19, load R1, D2, GM1, D3 conduct. The polarity of the output voltage is just opposite to the output obtained in the previous mode.

73 4.3.2 PSPICE Simulation Results - ZSMC The simulation results illustrates that the ZSMC is capable of producing output voltages at different amplitudes. -bucking input voltage 230V to 64V as shown in Fig 4.22. -boosting input voltage 230V to 340V as shown in Fig 4.23 -producing output voltage 230V at unity voltage transfer ratio as shown in Fig 4.24 A frequency changer is inherently a phase shifter. Hence the unique capability to provide output voltages at different frequencies is also demonstrated. Fig 4.25 shows Matrix output voltage at 50 Hz frequency. Fig 4.26 shows matrix output voltage at 30 Hz frequency. Fig 4.27 shows Matrix Output Voltage at 100 Hz frequency. 4.3.2.1 Matrix Output Voltage at Various Amplitudes Fig 4.22 Buck Voltage- 64 V

74 Fig 4.23 Boost Voltage- 340 V Fig. 4.24 Output Voltage at Unity Voltage Transfer Ratio-230V 4.3.2.2 Matrix Output Voltage at Various Frequencies Fig 4.25 Matrix Output Voltage at 50 Hz frequency

75 Fig 4.26 Matrix Output Voltage at 30 Hz frequency Fig 4.27 Matrix Output Voltage at 100 Hz frequency 4.4 SIMULINK MODEL OF DUAL BRIDGE ZSMC BASED UPFC A simple two bus single phase equivalent is chosen as the power system for investigating the performance of proposed ZSMC based UPFC. A generator of 210 kv (peak 300 kv) with a short circuit capacity of 15,000MVA is connected to bus 1. A transmission line rated at 210 KV and X/R ratio 9 is constructed. The ZSMC is connected to this transmission line through shunt and series transformers rated at 150 MVA. A single phase dual configuration based matrix converter with four switches is coupled to Z source

76 impedance circuit consisting of two inductors and two capacitors. This configuration is equivalent to two VSC s connected without the dc link capacitor and coupled to the Z source impedance. The entire simulink block diagram representing the above configuration and set up is clearly depicted in the Fig 4.28. 4.4.1 Control Strategy of ZSMC based UPFC The trigger inputs to the MOSFETS are provided by a PI controller in a closed loop control. The gating pulses are obtained by pulse width modulation. The control schematic diagram is as shown in Fig 4.29. The SSSC part or output of the matrix converter is operated in the Automatic Power Flow Control Mode. The SSSC injects a single phase ac voltage of controllable voltage magnitude and phase angle in series with the transmission line voltage. The actual values of line voltage, line current, real power and reactive power are measured using VI and PQ Simulink Blocks. The desired values of the real and reactive power at the output end of the matrix converter are given as the reference values. The mismatch of real and reactive power obtained from the comparator is corrected in the PI controller. The controller generates the control inputs. The output voltage range is decided by m and ρ. The boost factor ρ is controlled by the duty cycle of the zero state and non shoot through active state. During the shoot through zero state, only zero voltage is

77 impressed on the converter. The remaining active period is determined by the modulation index. A modulation index for the required voltage transfer ratio is set as initial reference which determines the on/off periods of the trigger signal. The reactive power mismatch produces the required displacement angle β. A phase locked loop (PLL) is used to determine the instantaneous relative phase angle θ of the line voltage and the current. For reactive power compensation, the injected voltage is given a phase angle shift with /2 added leading or lagging to transmission line current emulating capacitive or inductive mode. The STATCOM part or input to the matrix converter is responsible for regulation of the voltage at its point of coupling to the line. The STATCOM is operated in the Automatic Voltage Regulation Mode. The bus voltage magnitude is set as the reference and the actual value from the VI block is fed into the PI controller. The error signal produces the control signal to the STATCOM generator. The reactive power flow is due to the voltage difference across the transformer leakage reactance. Unity power factor is assumed on the input side of the matrix converter. Hence no reactive power exchange takes place on this side.

78 Fig.4.28 Simulink Block Diagram of 1 Ph Dual Bridge Configured ZSMC based UPFC

79 Fig 4.29 Control Strategy of ZSMC based UPFC

80 4.4.2 MATLAB-Simulink Results of ZSMC based UPFC A load of 50 MW, 20 MVAR is connected initially to bus 2. The load is then varied in steps. For different load variations there is a reduction in supply voltage and the line currents are found lagging. The UPFC is then connected to the line. A sudden peak load of 148% peak i.e. 74 MW and 30 MVAR is applied at 0.3 seconds through a circuit breaker. The transmission line voltage and current during peak load and without UPFC connected are shown in the Fig 4.30. During peak load it is noted that the supply currents has risen in magnitude and lagging. The line voltage shows decrease in voltage magnitude. After UPFC is connected, the voltage is restored to 300 KV peak as shown in Fig 4.31. A uniform profile of in phase voltage and current has been observed. The SSSC injected voltage is in phase with line voltage and lags the transmission line current at quadrature i.e. operating in capacitive mode is shown in Fig 4.32. The output voltage obtained at the matrix converter without using LC filter is as shown in Fig 4.33A and Fig 4.33B. At the input end of the matrix converter the power factor measured is found to be 0.99 as shown in the power factor diagram Fig 4.34. Hence it is proved that the storage elements of the Z source impedance has compensated for the switching losses. It is to be emphasized here that for the conventional UPFC, the power factor is found to be 0.96.

81 Fig.4.30 Transmission Line Voltage and Current during Peak Load condition Fig.4.31 Transmission Line Voltage and Current in phase with UPFC

82 Fig.4.32 Injected SSSC Voltage and Transmission Line Current Fig 4.33A ZSMC UPFC Output Voltage

83 Fig 4.33B ZSMC Output voltage with Trigger Pulses Fig 4.34 Input Power Factor Diagram

84 4.5 LAB SCALE MODEL PROPOSED ZSMC BASED UPFC The complete block diagram of the experimental set up is illustrated in the Fig 4.35. A simple 2 bus single phase model has been chosen as the sample power system. A line is constructed with an impedance of X/R ratio 0.22, similar to a radial distribution line. A single phase voltage source of 24V, 100 VA is connected to the bus 1. A single phase induction motor rated at 24V, 1.2A is loaded to see the effect of matrix converter as UPFC. The input end of the matrix converter has been assumed at unity power factor. The output voltage from the matrix converter is synchronized to the input voltage at 24 V, 50 Hz at unity voltage transfer ratio, with varied phase shift 4.5.1 Construction and Hardware Wiring Circuit Diagram. The matrix converter circuit is constructed using 4 MOSFET switches and anti parallel diodes. The Z source circuit consists of two inductors, two capacitors and one buck boost MOFET switch. The switching frequency in the Z source circuit is several times more than the operating frequency. Hence the inductors and capacitors is very small size. The complete hardware wiring diagram with matrix converter circuit, Z source circuit, driver circuit, zero detector circuit, power circuit and the microcontroller circuit is illustrated in the Fig 4.35. The hardware specifications are detailed in the Table 4.7. The 8 bit microcontroller AT89C51 is programmed to generate

85 PWM signals to trigger 4 MOSFETS in the matrix converter and one number MOSFET in the Z source network through the gate driver circuit. The comparator provides a reference signal to generate trigger signals in synchronization with the supply voltage. The zero crossing of the ac supply is detected through ZCD. The program generates a pulsed signal at 50 HZ. The magnitude of the injected voltage is varied by the modulation index in the matrix converter. A delay is obtained at the output of the matrix converter by adding a delay instructionn before the start of the trigger. As the phase shift θ is increased introducing the time delay, the outpu voltage shifts with respect to supply voltage. LC components are used to obtain a smooth sinusoidal voltage to synchronize with ac input voltage. Fig 4.35 Hardware Block Diagram of ZSMC based UPFC

86 4.5.2 Triggering Pulses Algorithm 1. Start the program 2. Initialize port 1 as output 3. Initialize port 0 as input 4. Initialize ZCD output as interrupt 5. Initialize Port 3 for timer operation 6. Read the interrupt 7. Read the input 8. If input is positive, then send the positive triggering code to the output port 9. Set the time delay by time operation 10. Read Input 11. If the input is negative,then send negative triggering code to the output port 12. Set the time delay by time operation 13. Repeat the process for continuous pulses 14. End program

87 OVERALL CIRCUIT DIAGRAM Fig.4.36 Hardware Wiring Diagram Power Circuit & Control Circuit of ZSMC

88 4.5.3 Experimental Results of ZSMC-UPFC The complete experimental set up is depicted in the photo shot shown in Fig 4.37. The voltage at the output of matrix converter obtained in the CRO without using LC filters at 24V is shown in Fig 4.38. Using LC components the output voltage at the matrix converter is synchronised with the input voltage 24V, 50 Hz as depicted in Fig 4.39. Fig. 4.37 Experimental Setup of ZSMC based UPFC Fig. 4.38 ZSMC Output Voltage 24V at CRO

89 Fig. 4.39 ZSMC Output Voltage synchronized with Supply Voltage 24V Table 4.7 ZSMC based UPFC Hardware Specifications Sl.No Name of Component 1 Transmission line 2 Power circuit Rating Input = 24V R ohms, X = 3.33 ohms Step down Transformer = 230/24 V Load = 1 Ph induction Motor, 24V, 1.2A 1. Uncontrolled Rectifier Ckt ( Diodes) = IN4007 2. Supply voltage to Driver circuit, Opto Coupler circuit and ZCD = 240/15 V 3. Supply voltage to Microcontroller = 230V/6V Trf 3 Z source Circuit Input voltage = 230/24V LC filter = Inductor L1-10 µh Capacitor- C1-22 pf Buck-Boost Switch = MOSFET IRF840-500 V, 10 A Switching Diode IN4500 Z source circuit = L2,L3-10µH C2,C3-0.33 pf 4 1 PH Matrix Converter UPFC 5 Gate Driver circuit 6 Micro Controller 7 Isolation Circuit 8 Zero Crossing detector (ZCD) with Comparator MOSFET = IRF840, 500V, 8A Switching Diodes = IN4500 Shunt Step down Transformer = 230V/24V. Series Step up Transformer = 24V/230 V IR2110-12 V AT89C51-8 bit Optocoupler-MCT2E LM 339(2 OR gates + 1 edge detector).

90 4.6 SUMMARY OF SIMULATION AND EXPERIMENTAL RESULTS The capability of ZSMC to boost input voltage 230 V to 340V, buck to 64V and attain unity voltage transfer ratio at 230V has been demonstrated in the PSPICE simulation results. A frequency changer is inherently a phase shifter and ZSMC has also illustrated its capability to link power systems at different frequencies. The results have shown output voltage at different frequencies 30 Hz, 100 Hz and 50 Hz. The MATLAB-Simulink results have demonstrated the capabilities of the ZSMC as UPFC connected to the transmission line. The compensated voltage shows good synchronization with the line voltage. Also the near unity power factor obtained at the input or STATCOM side of the matrix converter has proved that no real power is drawn by the converter. The storage elements of Z source have given the boost effect to the voltage transfer ratio. Thus the proposed ZSMC based UPFC model has the capability to compensate for the real power loss associated with converters switching, without drawing from the transmission line unlike in the case of traditional VSC and conventional Matrix Converter based UPFC The experimental results have illustrated synchronization of the output voltage at unity voltage transfer ratio with the 24V input voltage at the required phase shift. Thus a good correlation between the experimental results and the simulation results has been observed.