of surface microstructure

Similar documents
Large Field of View, High Spatial Resolution, Surface Measurements

Contouring aspheric surfaces using two-wavelength phase-shifting interferometry

Calibration of numerical aperture effects in interferometric microscope objectives

White-light interferometry, Hilbert transform, and noise

SENSOR+TEST Conference SENSOR 2009 Proceedings II

06SurfaceQuality.nb Optics James C. Wyant (2012) 1

Dynamic Phase-Shifting Electronic Speckle Pattern Interferometer

SUPRA Optix 3D Optical Profiler

Coherence radar - new modifications of white-light interferometry for large object shape acquisition

ASM Webinar Digital Microscopy for Materials Science

Modifications of the coherence radar for in vivo profilometry in dermatology

Use of Computer Generated Holograms for Testing Aspheric Optics

Surface Finish Measurement Methods and Instrumentation

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

Errors Caused by Nearly Parallel Optical Elements in a Laser Fizeau Interferometer Utilizing Strictly Coherent Imaging

Frequency-stepping interferometry for accurate metrology of rough components and assemblies

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

Section 2 ADVANCED TECHNOLOGY DEVELOPMENTS

S.R.Taplin, A. Gh.Podoleanu, D.J.Webb, D.A.Jackson AB STRACT. Keywords: fibre optic sensors, white light, channeled spectra, ccd, signal processing.

Sinusoidal wavelength-scanning interferometer using an acousto-optic tunable filter for measurement of thickness and surface profile of a thin film

Dynamic Phase-Shifting Microscopy Tracks Living Cells

University of Huddersfield Repository

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Basics of INTERFEROMETRY

Optotop. 3D Topography. Roughness (Ra opt, Rq opt, and Rz opt) Height Distribution. Porosity Distribution. Effective Contact Area

Application Note #548 AcuityXR Technology Significantly Enhances Lateral Resolution of White-Light Optical Profilers

Extended vertical range roughness measurements in non-ideal environments

Non-contact 3D optical profiler

doi: /j.optlaseng

Manufacturing Metrology Team

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source

Sensitive measurement of partial coherence using a pinhole array

Asphere and Freeform Measurement 101

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Vibration stabilization of a phase shifting interferometer for large optics

Basics of INTERFEROMETRY

Noise Tolerance of Improved Max-min Scanning Method for Phase Determination

New Phase Shifting Algorithms Insensitive to Linear Phase Shift Errors J. Novák

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Chapter 7. Optical Measurement and Interferometry

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

USE OF COMPUTER- GENERATED HOLOGRAMS IN OPTICAL TESTING

High-Speed 3D Sensor with Micrometer Resolution Ready for the Production Floor

PhD Thesis. Balázs Gombköt. New possibilities of comparative displacement measurement in coherent optical metrology

Measurement of Surface Profile and Layer Cross-section with Wide Field of View and High Precision

In-line digital holographic interferometry

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

Optical Signal Processing

(51) Int Cl.: G01B 9/02 ( ) G01B 11/24 ( ) G01N 21/47 ( )

Imaging Fourier transform spectrometer

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Low coherent Linnik interferometer optimized for use in Nano Measuring Machines

J. C. Wyant Fall, 2012 Optics Optical Testing and Testing Instrumentation

Department of Mechanical and Aerospace Engineering, Princeton University Department of Astrophysical Sciences, Princeton University ABSTRACT

1.6 Beam Wander vs. Image Jitter

1 Introduction Installation... 4

Semiconductor wafer defect detection using digital holography

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Vibration-compensated interferometer for measuring cryogenic mirrors

System Configuration 3D Optical Profi ler Dimensions SENSOFAR SENSOFAR-TECH, SL. TERRASSA SENSOFAR Japan Ltd.

Investigation of some critical aspects of on-line surface. measurement by a wavelength-division-multiplexing. technique

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

Comparison of resolution specifications for micro- and nanometer measurement techniques

A study of key optical profiler parameters for form error measurement

Three-dimensional quantitative phase measurement by Commonpath Digital Holographic Microscopy

Diffractive interferometer for visualization and measurement of optical inhomogeneities

Sinusoidal wavelength-scanning common-path interferometer with a beam-scanning system for measurement of film thickness variations

A New Profile Measurement Method for Thin Film Surface

Superfast phase-shifting method for 3-D shape measurement

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Interference [Hecht Ch. 9]

High Spatial Resolution Metrology using Sub-Aperture Stitching

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Measurement of a convex secondary mirror using a

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

Laser Telemetric System (Metrology)

Solution Set #2

Design of a digital holographic interferometer for the. ZaP Flow Z-Pinch

LightGage Frequency Scanning Technology

Fabrication of large grating by monitoring the latent fringe pattern

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Testing Aspherics Using Two-Wavelength Holography

Diffraction, Fourier Optics and Imaging

Analysis of phase sensitivity for binary computer-generated holograms

Bringing Answers to the Surface

Bruker Optical Profilometer SOP Revision 2 01/04/16 Page 1 of 13. Bruker Optical Profilometer SOP

MICROMACHINED INTERFEROMETER FOR MEMS METROLOGY

Optics and Lasers. Matt Young. Including Fibers and Optical Waveguides

Single-shot areal profilometry using hyperspectral interferometry with a microlens array

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

2 CYCLICAL SHEARING INTERFEROMETER

Sub-nanometer Interferometry Aspheric Mirror Fabrication

DetectionofMicrostrctureofRoughnessbyOpticalMethod

Spatial Filtering of Surface Profile Data

Synthesis of projection lithography for low k1 via interferometry

All-Glass Gray Scale PhotoMasks Enable New Technologies. Che-Kuang (Chuck) Wu Canyon Materials, Inc.

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

Transcription:

Invited Paper Computerized interferometric measurement of surface microstructure James C. Wyant WYKO Corporation, 2650 E. Elvira Road Tucson, Arizona 85706, U.S.A. & Optical Sciences Center University of Arizona Tucson, Arizona 85721, U.S.A. ABSTRACT Nearly all modern high-quality measuring instruments now use micro computers for the collection and analysis of data. This paper describes a computerized interferometric microscope system for the measurement of surface microstructure. For the instrument described in this paper the surface microstructure can be measured at data array sizes as large as 739 x 484 points for measurement fields ranging from 30 x 25 microns to 8.2 x 6. 1 mm. A repeatability of the surface height measurements of less than 0. 1 nm can be obtained for smooth surfaces. Surfaces having height variations as large as 500 microns can be measured to within an accuracy of a few nanometers. Keywords: Interferometry, metrology, non-contact profiling, microstructure. 1. INTRODUCTION Figure 1 shows a simplified schematic of the instrument (called RST Plus).13 The configuration shown in Figure 1 utilizes a two-beam Mirau interferometer at the microscope objective. A tungsten halogen lamp is used as the light source. In the phase shifting mode of operation, described below, a spectral filter of 40 nm bandwidth centered at 650 nm is used to increase the coherence length. For the vertical scanning mode of operation, also described below, the spectral filter is not used. Light reflected from the test surface interferes with light reflected from the reference. The resulting interference pattern is imaged onto the CCD array. The output of the CCD array can be viewed on the TV monitor. Also, output from the CCD array is digitized and read by the computer. The Mirau interferometer is mounted on either a piezoelectric transducer (PZT) or a motorized stage so that it can be moved. During this movement, the distance from the lens to the reference surface remains fixed. Thus, a phase shift is introduced into one arm of the interferometer. By introducing a phase shift into only one arm while recording the interference pattern that is produced, it is possible to perform either the direct phase measurement technique described below or the vertical scanning coherence sensing technique also described below. The complete RST Plus system includes a Pentium computer running Microsoft Windows for data analysis and graphics display. 122 /SP1E Vol. 2576 O-8194-1937-O/95/$6.OQ

Field Stop Aperture Stop\ Magnification Selector Microcope White Light Source Spectral Filter (Phase Shifting Only) Test Surface' Interferometer Figure 1. Optical schematic of interference microscope used for measurement of fine surface structure. Data analysis of the surface profile provides the peak-to-valley roughness of the surface, the rootmean-square roughness (Rq), the arithmetic mean (Ra), and the peak-to-valley height (Rt). The output is in the form of color contour maps, three-dimensional surface plots, slices through the three-dimensional plots, histograms, and bearing ratio plots. If the operator desires, the computer analysis can also provide output describing slope maps, power spectra, autocovariance, peak distribution, and zero crossings. The software has the capability to frequency filter the data. The Mirau interferometer is used with magnification objectives of 40X, 20X, and lox. 2.5X and 1.5X magnifications are also available using a Michelson interferometer. A large numerical aperture box magnification can be achieved using a Linnik interferometer. Table 1 shows the specifications for the different magnifications available. For additional variations of the field of view, a magnification selector placed between the microscope objective and the CCD array can change the overall magnification by 0.5 or 2.OX. Two modes of operation are available. For smooth surfaces the phase shifting mode is used since it gives sub-nanometer height resolution capability. For rougher surfaces, up to several hundred micron surface height variations, a vertical scanning coherence sensing technique is used which gives approximately a 3 nm height resolution. These two modes of operation are described below. 2. PHASE-SHIFTING INTERFEROMETRY An optical profiler can use several phase measurement techniques that yield more accurate height measurements than are possible with the traditional technique, which determines visually how much SPIE Vol. 2576 / 123

interference fringes depart from being straight and equally spaced. One mode of operation of the profiler described in this paper is the integrated-bucket phase shifting technique.45 For this technique, the phase difference between the interfering beams is changed at a constant rate as the detector is read out. Each time the detector array is read out, the time variable phase, a(t), has changed by 900 for each pixel. The basic equation for the irradiance of a two-beam interference pattern is given by I = Ii + 12 cos[(x,y) + cx(t)] (1) where the first term is the average irradiance, the second term is the interference term, and (x,y) is the phase distribution being measured. If the irradiance is integrated while cz(t) varies from 0 to it/2, it/2 to it, and it to 3it/2, the resulting signals at each detected point are given by A(x,y) =Ii' + 12' [cos (x,y) - sin (x,y)] B(x,y) = Ii' + 12 [-cos (x,y) - sin (x,y)] (2) C(x,y) = Ii' + 12' [-cos (x,y) + sin 4(x,y)]. From the values of A, B, and C, the phase can be calculated as (x,y) = tan-1[ (C(x,y) - B(x,y))/(A(x,y) - B(x,y)) I. (3) The subtraction and division cancel out the effects of fixed pattern noise and gain variations across the detector, as long as the effects are not so large that the dynamic range of the detector becomes too small to be of use. Because Eq. (3) gives the phase modulo 2rc, there may be discontinuities present in the calculated phase. These 2it discontinuities can be removed as long as the slopes on the sample being measured are limited so that the actual phase difference between adjacent pixels is less than it. This is done by adding or subtracting multiples of 2it to a pixel until the difference between it and its adjacent pixel is less than 7C. Once the phase (x,y) is determined across the interference field, the corresponding height distribution h(x,y) on the test surface is determined by the equation h(x,y) = (?J4it) (x,y). (4) 3. VERTICAL SCANNING COHERENCE SENSING In the vertical scanning coherence sensing mode of operation an unfiltered white light source is used. Due to the large spectral bandwidth of the source, the coherence length of the source is short, and good 124 ISPIE Vol. 2576

contrast fringes will be obtained only when the two paths of the interferometer are closely matched in length. Thus, if in the interference microscope the path length of the sample arm of the interferometer is varied, the height variations across the sample can be determined by looking at the sample position for which the fringe contrast is a maximum. In this measurement there are no height ambiguities and, since in a properly adjusted interferometer the sample is in focus when the maximum fringe contrast is obtained, there are no focus errors in the measurement of surface microstructure.69 The major drawback of this type of scanning interferometer measurement is that only a single surface height is being measured at a time and a large number of measurements and calculations are required to determine a large range of surface height values. One method for processing the data that gives both fast and accurate measurement results is to use conventional communication theory and digital signal processing (DSP) hardware to demodulate the envelope of the fringe signal to determine the peak of the fringe contrast.8'9 Vertical scan rates as large as 7.2 microns per second are available. Figure 2 shows the irradiance at a single sample point as the sample is translated through focus. It should be noted that this signal looks a lot like an amplitude modulated (AM) communication signal. To obtain the location of the peak, and hence the surface height information, this irradiance signal is detected using a CCD array. The signal is sampled at fixed intervals, such as every 50 to 100 nm, as the sample path is varied. The motion can be accomplished using a piezoelectric transducer. Low frequency and DC signal components are removed from the signal by digital highpass filtering. The signal is next rectified by square-law detection and digitally lowpass filtered. The peak of the lowpass filter output is located and the vertical position corresponding to the peak is noted. Interpolation between sample points can be used to increase the resolution of the instrument beyond the sampling interval. This type of measurement system produces fast, non-contact, true three-dimensional area measurements for both large steps and rough surfaces. 0 Optical Path Difference Figure 2. Irradiance at a single sample point as the sample is translated through focus. SPIE Vol. 2576 / 125

4. FIELD OF VIEW, SPATIAL SAMPLING INTERVAL, AND SURFACE SLOPE LIMIT Table 1 gives the field of view, spatial sampling interval, and surface slope limit for the different objectives and magnification selector used between the objective lens and the CCD array. Other magnifications could be used, but these are typical magnifications used in interference microscopes. Table 1. Field of View, Sampling Interval, and Slope Limit. Magnification objective 1.5X 2.5X lox 20X 40 ioox Interferometer type Michelson Michelson Mirau Mirau Mirau Linnik Numerical aperture 0.036 0.075 0.25 0.4 0.5 0.9 Working distance (mm) 8 2 4 1.9 3.9 0.2 Field of view (mm) (with magnification selector) O.5X 1.ox 2.ox 8.2 x 6.1 4.3 x 3.2 2.1 x 1.6 4.9 x 3.7 2.6x 1.9 1.3 x 1.0 1.2 x 0.9 0.6x0.5 0.3 x 0.2 0.6 x 0.5 0.3 x 0.2 0.2 x 0.1 0.3 x 0.2 0.12 x 0.0 0.15 x 0.1 0.06 x 0.05 0.08 x 0.06 0.03 x 0.02 Spatial_sampling (with magnification selector) (micron) o.sx 12.7 7.6 1.9 1 0.5 0.2 i.ox 6.6 4 1 0.5 0.2 0.1 2.OX 3.3 2 0.5 0.2 0.1 0.05 126 /SPIE Vol. 2576

5. MEASUREMENT EXAMPLES The applications for an interferometer for the measurement of fine structure are diverse, ranging from optical surfaces, to magnetic media and thin film read/write heads, to machined surfaces, to biomedical applications, to almost any surface imagined. Some examples of measurements of various surfaces are shown in Figures 3 through 6 in three-dimensional plotted format. Other display formats are available including color contour maps, two-dimensional plots, histograms and various data analyses which do not reproduce well in black and white. urn 12.7 5.0 0.0-5.0-10.0-18.3 Figure 3. Three-dimensional plot of metal plate with laser drilled holes having Rq=5.07 microns, Ra=3.44 microns, and Rt=31.05 microns. SPIE Vol. 2576 / 127

Figure 4. Three-dimensional surface map of camshaft showing tool chatter having Rq=790.4 nm, Ra=626.51 nm, and Rt=6.OO microns. urn 1.19 0.50-0.00-0.50 - -1.18 Figure 5. Three-dimensional surface map of binary lens having Rq=561.30 nm, Ra=476.71 nm, and Rt=2.37 microns. 128 ISPIE Vol. 2576

urn 17.8 I-10.0-18.1 Figure 6. Three-dimensional surface map of paper sample having Rq=4.91 microns, Ra=3.89 microns, and Rt=35.85 microns. CONCLUSION This paper has described the operation and performance of a non-contact microsurface profiling instrument. This computer-controlled instrument has extensive software and, while it is only possible to illustrate a few of the profile results here, it has been demonstrated to provide useful surface data for a wide variety of surfaces. The instrument has found extensive uses in applications such as the testing of optical components and the evaluation of the recording heads used in magnetic disk drives in computers. The instrument is used in measuring the print rollers used in the printing industry and measuring gears and bearings for the automotive industry. In the biomedical area the instrument is useful for measuring heart valves and hip joint replacements. The microscope is even useful in exotic applications such as measuring potato chip bags to determine which ones are most likely to keep the potato chips fresh for the longest time. SPIE Vol. 2576 / 129

REFERENCES 1. B. Bhushan, ic. Wyant and C.L. Koliopoulos, 'Measurement of surface topography of magnetic tapes by Mirau interferometry," Appi. Opt., 28, 1489-1497, 1985. 2. J.C. Wyant, "Optical profilers for surface roughness," Proc. SPIE, 525, 174-1 80, 1985. 3. J. C. Wyant and K. Creath, "Advances in interferometric optical profiling," mt. J. Mach. Tools Manufact., 32(1/2), 5-10, 1992. 4. J. C. Wyant, "Use of an ac heterodyne lateral shear interferometer with real-time wavefront corrections systems," Appi. Opt., 14(11), 2622-2626, Nov. 1975. 5. K. Creath, "Phase-shifting interferometry techniques," in Progress in Optics XXVI, E. Wolf, ed. (Elsever Science, 1988), pp. 357-373. 6. M. Davidson, K. Kaufman, I. Mazor, and F. Cohen, "An application of interference microscopy to integrated circuit inspection and metrology," Proc. SPIE, 775, 233-247 (1987). 7. G. S. Kino and S. Chim, "Mirau correlation microscope," App!. Opt. 29, 3775-3783 (1990). 8. T. Dresel, G. Hausler, and H. Venzke, "Three-dimensional sensing of rough surfaces by coherence radar," App!. Opt. 3 1(7), 919-3925, March 1992. 9. P. J. Caber, "An interferometric profiler for rough surfaces," App!. Opt. 32(19), 3438-3441, July 1993. 130/SPIE Vol. 2576