MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

Similar documents
ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

RSMFX-2R MULTIFUNCTIONAL

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Output Signal Active Temperature. Electrical data Power Supply DC V, ±10%, 0.5 W

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

Operator s Manual. PP016 Passive Probe

Type Overview. Technical Data. Outdoor Humidity, Temperature Sensor

DP2500 DP0100 DP0250 Differential Pressure Transmitter

PRetrans Table of contents

OPERATOR S INSTRUCTION MANUAL

CONTENTS XV300K GB r doc XV300K 2/13

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

User Manual 4 wire Earth Resistance Tester Model GRT300

Outdoor wireless double wall switch

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

Output Signal Active Note. Output Signal Temperature 22UTH-51 DC V, DC V

AMM-1022 Digital Multimeter USER`S MANUAL

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

Antenna Splitter ASA 1. Instruction manual

Precipitation Monitor ,

MRS-1000 RADAR SYSTEM USER MANUAL

INSTALLATION MANUAL GIOTTO SCREEN

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Digital flow transmitter for continuous flow measurement

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Pen-type DIGITAL MULTITESTER

Installation instructions

Precipition Sensor with analogue Intensity Output ,

This section is specifically about safety matters

PHV RO High Voltage Passive Probe. Instruction Manual

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Multifunction Digital

Digital Clamp Meter Model: &

Model: &

DIGITAL MULTIMETER AUTORANGING

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

Operator s Manual. PP022 Passive Probe

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

For detailed specifications and ordering info go to

USER S MANUAL. Rail-mounted temperature transmitter ATL

Efficiency higher than 85% Power Factor >92% Case TC* Protection Storage Humidity

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Z07- SWING GATE HOME AUTOMATION. zero Z07 - SWING GATE MOTOR SUPPLY V HOME AUTOMATION IT EN FR Z07.REV USER MANUAL AND CONFIGURATION PG1

INSTRUCTION MANUAL Vibration Meter

INSTRUCTION MANUAL (ATEX / IECEx)

Mounting method DIN rail mounting or screw mounting Screw mounting Mass [g] Material Case: Plastics PCB: FR-4

Digital Multimeter, Pen Type

w w w. p r o l i g h t. c o. u k

ph or ORP Transmitter

BACKSAVER VERSION 1.5 Hammer Drill Attachment

HITEK POWER OL600W SERIES

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

User s Guide. Model MA A AC Mini Clamp-on Meter

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

KC: KC , KC , KC62384, KS C 7655 Safety Certifications Approved RoHS Compliant. Dim. Method. Parameter Min. Typ. Max.

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Thank you for purchasing a qualiton A50i power amplifier!

Model DIGITAL MULTIMETER

Metal Case Power Supplies

AC 3. Active Antenna Combiner. Instruction manual

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Industrial motor controller for brushed DC motors 24 VDC

IP Series DUAL POWER AMPLIFIERS

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

OCTOPUS CONTROL STATION

Astra-R Kit Wireless Alarm System Operation Manual

Circuit Breaker Finder

Installation and Operating Manual

Thank you for purchasing a qualiton A20i power amplifier!

- 4 - Fig. 3b. Fig. 1b. Fig. 2. Fig. 2b MT 300

DDM350 Pen-Type Digital Multimeter User s Manual

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

PKT 512A-RO High Impedance Passive Cable Divider

LL-105-R LED Dimmer & 0-10V Bridge Setup Guide

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

EN , EN , K , K , K62384 Safety Certifications Approved RoHS Compliant. Dim. Method

This section is specifically about safety matters

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

MODEL AT-10 ANALOG TRANSMITTER

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

RHS SERIES RH Set Point Controller/Probe

Operating Instructions K-POWERgrip EWL Always on the safe site.

HITEK POWER OLS10K SERIES

SAFETY PRECAUTIONS: Before use, read the following safety precautions

1/4in. SHEET PALM SANDER

OPERATING MANUAL SESAM 800 MOBILE TAIL LIFT EN -D0

Transcription:

& MAX SETTINGS, DRY CONTACT Mounting and operating instructions

Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 WIRING AND CONNECTIONS 5 MOUNTING INSTRUCTIONS IN STEPS 5 TRANSPORT AND STOCK KEEPING INFORMATION 7 WARRANTY INFORMATION AND RESTRICTIONS 7 MAINTENANCE 7 2-7

SAFETY AND PRECAUTIONS Read all information, the datasheet, mounting instructions and wiring scheme before working with the product. For personal and equipment safety, and for optimum product performance, make sure you entirely understand the contents before installing, using, or maintaining this product. For safety and licensing (CE) reasons, unauthorised conversion and / or modifications to the product are not permitted. The product must not be exposed to abnormal conditions, such as: extreme temperatures, direct sunlight or vibrations. Chemical vapours with high concentration in combination with long exposure times can affect the product performance. Make sure the work environment is as dry as possible; check for condensation spots. All installations shall comply with the local health and safety regulations and local electrical codes. This product can only be installed by an engineer or a technician who has an expert knowledge of the product and safety precautions. Avoid contacts with energised electrical parts; always treat the product as if it is life. Always disconnect the power source before connecting the power cables, servicing or repairing the product. Always verify that you apply appropriate power supply to the product and use wires with appropriate size and characteristics. Make sure that all the screws and nuts are well tightened and fuses (if any) are fitted well. Recycling of equipment and packaging should be taken into consideration and disposed in accordance with local and national legislation / regulations. In case there are any questions that are not answered, please contact your technical support or consult a professional. 3-7

PRODUCT DESCRIPTION ARTICLE CODES The potentiometer uses a supply of 230 VAC, and gives a stepless output signal (0 10 VDC, 0 20 ma or PWM). The minimum output values can be adjusted within 1 7 VDC / 2 14 ma / 10 70 % PWM, and the maximum values - within 3 10 VDC / 6 20 ma / 30 100 % PWM. There is an additional switch on/off function (e.g. for controller remote on/off). Code Supply Output MTV-1/010-CP 230 VAC ± 10 % - 50 / 60 Hz Vmin Vmax INTENDED AREA OF USE TECHNICAL DATA STANDARDS Applications where a 0 10 VDC, 0 20 ma or PWM control signal is required For indoor use only Power supply: 230 VAC ± 10 % - 50 / 60 Hz Load: 0 10 VDC mode: 2 kω (RL 2 kω) 0 20 ma mode: 500 Ω (RL 500 Ω) PWM mode: 2 kω (RL 2 kω) Selectable output: 0 10 VDC / 0 20 ma / PWM Minimum output setting, Vmin: 1 7 VDC / 2 10 ma / 10 70 % PWM Maximum output setting, Vmax: 3 10 VDC / 6 20 ma / 30 100 % PWM Dry contact, CS: closed: ON open: OFF Enclosure: External: ASA, white-ivory (RAL 9010), IP54 (according to EN 60529) Internal: polyamide, white-ivory (RAL 9010), IP44 (according to IEC 60335) Operating ambient conditions: temperature: 0 40 C rel. humidity: < 100 % rh (non-condensing) Storage temperature: -10 55 C Low Voltage Directive 2014/35/EC EMC Directive 2014/30/EC WEEE Directive 2012/19/EU RoHs Directive 2011/65/EU 4-7

WIRING AND CONNECTIONS L, N Power supply (230 VAC ± 10 % - 50 / 60 Hz) CS Out (+ -) Dry contact for remote ON/OFF Output voltage (0 10 VDC / 0 20 ma / PWM) Connections Cable cross section: max. 1,5 / 2,5 mm 2 MOUNTING INSTRUCTIONS IN STEPS Before you start mounting your potentiometer read carefully Safety and Precautions. Then proceed with the following mounting steps: For inset mounting 1. Remove the knob by turning it to the right, beyond the stop end and then pull. Open the cover and unscrew the loose nut. 2. Do the wiring according to the wiring diagram (see Fig. 1). Fig. 1 Wiring and connections Power supply Dry contact for remote ON/OFF Output voltage 3. Mount the internal enclosure into the wall according to the mounting dimensions shown in Fig. 2. Fig. 2 Mounting dimensions - inset mounting 82 26 33 89 50x50 7 NOTE The terminal block and connections should face down. 5-7

4. Use the jumper shown in Fig. 3 to set the desired output mode. 5. Set the trimmers Vmin and Vmax to the desired position. See Fig. 4 Trimmers. Fig. 3 Output selection jumper Fig. 4 Trimmers 6. Mount the cover with the nut. 7. Push the knob in place at off position. 8. Turn on the power supply. For surface mounting 1. Remove the knob by turning it to the right, beyond the stop end and then pull. Open the cover and unscrew the loose nut. 2. Mount the external enclosure to the wall by screws and dowels (not delivered). Consider the mounting dimensions shown in Fig. 5. Fig. 5 Mounting dimensions - surface mounting 62 62 7 3. Insert cables through the grommets. 4. Do the wiring according to the wiring diagram (see Fig. 1). 5. Mount the internal enclosure into the external enclosure by means of the delivered screws and washers. NOTE The terminal block and connections should face down. 6. Use the jumper shown in Fig. 3 to set the desired output mode. 7. Set the trimmers Vmin and Vmax to the desired position. See Fig. 4 Trimmers. 8. Mount the cover with the nut. 9. Push the knob in place at off position. 10. Turn on the power supply. NOTE You can drill a hole (5 mm) at the bottom of the external enclosure to take away the condensed water. 6-7

TRANSPORT AND STOCK KEEPING INFORMATION Avoid shocks and extreme conditions; stock in original packing. WARRANTY INFORMATION AND RESTRICTIONS Two years from the delivery date against defects in manufacturing. Any modifications or alterations to the product after the date of publication relieve the manufacturer of any responsibilities. The manufacturer bears no responsibility for any misprints or mistakes in this data. MAINTENANCE In normal conditions this product is maintenance-free. If soiled, clean with a dry or dampish cloth. In case of heavy pollution, clean with a non aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. 7-7