Final ballot January BOT adoption February 2015

Similar documents
Standard PRC Coordination of Generating Unit or Plant Capabilities, Voltage Regulating Controls, and Protection

Standard PRC Coordination of Generating Unit or Plant Capabilities, Voltage Regulating Controls, and Protection

Standard PRC Coordination of Generating Unit or Plant Voltage Regulating Controls with Generating Unit or Plant Capabilities and Protection

Final ballot January BOT adoption February 2015

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction. See the Implementation Plan for PRC

Standard PRC Generator Frequency and Voltage Protective Relay Settings. A. Introduction

VAR Generator Operation for Maintaining Network Voltage Schedules

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules

generation greater than 75 MVA (gross aggregate nameplate rating) Generation in the ERCOT Interconnection with the following characteristics:

Standard COM Communications

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules. 45-day Formal Comment Period with Initial Ballot June July 2014

Standard VAR-002-2b(X) Generator Operation for Maintaining Network Voltage Schedules

Standard MOD Verification of Models and Data for Generator Excitation Control Sys tem or Plant Volt/Var Control Functions

VAR Generator Operation for Maintaining Network Voltage Schedules

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

Standard MOD Verification of Models and Data for Generator Excitation Control System or Plant Volt/Var Control Functions

PRC Generator Relay Loadability. A. Introduction 1. Title: Generator Relay Loadability 2. Number: PRC-025-1

Standard TOP Monitoring System Conditions

Standard Development Timeline

VAR Generator Operation for Maintaining Network Voltage Schedules

NORMES DE FIABILITÉ DE LA NERC (VERSION ANGLAISE)

VAR Generator Operation for Maintaining Network Voltage Schedules

A. Introduction. VAR Voltage and Reactive Control

VAR Voltage and Reactive Control

VAR Generator Operation for Maintaining Network Voltage Schedules

(Circuits Subject to Requirements R1 R5) Generator Owner with load-responsive phase protection systems as described in

VAR Voltage and Reactive Control. A. Introduction

Standard Development Timeline

Standard Development Timeline

PRC Disturbance Monitoring and Reporting Requirements

Standard VAR Voltage and Reactive Control

Standard Development Timeline

August 25, 2017 VIA ELECTRONIC FILING

August 25, Please contact the undersigned if you have any questions concerning this filing.

Standard BAL Frequency Response and Frequency Bias Setting

Standard Development Timeline

WECC Standard VAR-002-WECC-2 Automatic Voltage Regulators

Standard MOD Area Interchange Methodology

5. Effective Date: On the first day of the first quarter, after applicable regulatory approval.

1

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) )

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Definition of Bulk Electric System Phase 2

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

THIS DOCUMENT IS RETIRED BY FERC EFFECTIVE SEPTEMBR 5, 2018.

Implementation Plan Project Modifications to PRC Reliability Standard PRC-025-2

Industry Webinar Draft Standard

Bulk Electric System Definition Reference Document

4.2.1 Generators Transformers Transmission lines. 5. Background:

BEFORE THE ALBERTA ELECTRIC SYSTEM OPERATOR

Bulk Electric System Definition Reference Document

Bulk Electric System Definition Reference Document

Standard VAR b Generator Operation for Maintaining Network Voltage Schedules

May 30, Errata to Implementation Plan for the Revised Definition of Remedial Action Scheme Docket No. RM15-13-_

System Operating Limit Definition and Exceedance Clarification

September 19, Errata to Implementation Plan for the Revised Definition of Remedial Action Scheme

ReliabilityFirst Regional Criteria 1. Disturbance Monitoring and Reporting Criteria

Implementation Plan Project Alignment of Terms

An Introduction to Completing a NERC PRC-019 Study for Traditional and Distributed Generation Sources

Unit Auxiliary Transformer Overcurrent Relay Loadability During a Transmission Depressed Voltage Condition

Cover Sheet. Technical Justification Retirement of WECC Regional Reliability Standard VAR-002-WECC-2 Automatic Voltage Regulators (AVR)

NERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

VAR Outreach Presentation

Setting and Verification of Generation Protection to Meet NERC Reliability Standards

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

No I am concerned about units that may be individually less than 20 MVA but collectively could eb much larger - wind farms. Yes

Recently, the SS38 Working Group on Inter-Area Dynamic Analysis completed two study reports on behalf of the UFLS Regional Standard Drafting Team.

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

Implementation Plan Project Balancing Authority Reliability-based Controls - Reserves

Loss of Solar Resources during Transmission Disturbances due to Inverter Settings II

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

NPCC Regional Reliability Reference Directory # 12. Underfrequency Load Shedding Program Requirements

TABLE OF CONTENT

NERC Protection Coordination Webinar Series July 15, Jon Gardell

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

FACILITY RATINGS METHOD TABLE OF CONTENTS

Power Plant and Transmission System Protection Coordination

Standard BAL b Automatic Generation Control

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 2 MW

1200 MW Fault Induced Solar Photovoltaic Resource Interruption Disturbance Report

Unit Auxiliary Transformer (UAT) Relay Loadability Report

INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard. Event Selection Process

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

APPENDIX 1 to LGIP INTERCONNECTION REQUEST FOR A LARGE GENERATING FACILITY

Transmission Availability Data System Phase II Final Report

Standard BAL b Automatic Generation Control

NORTH AMERICAN ELECTRIC RELIABILITY COUNCIL

BED INTERCONNECTION TECHNICAL REQUIREMENTS

Southern Company Interconnection Requirements for Inverter-Based Generation

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW

Connection Impact Assessment Application Form

Considerations for Power Plant and Transmission System Protection Coordination

Meeting Notes Project Remedial Action Schemes Standard Drafting Team January 19-22, :00 p.m. 5:00 p.m. PT

Transcription:

Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed 1. SAR posted for comment November 20 December 19, 2013. 2. The Standards Committee authorized this posting on September 30, 2014. 3. Initial posting of revised standard PRC-019-2 on November 5, 2014. Description of Current Draft PRC-019-2 is proposed for approval to align the applicability section of PRC-019-1 with the revised definition of the Bulk Electric System (BES). Specifically, the Project 2014-01 Standards Applicability for Dispersed Generation Resources standards drafting team has recommended revisions to the Facilities section to clarify that facilities that solely regulate voltage at the individual generating unit are subject to the requirements. Project 2014-01 does not have in its scope any technical content changes beyond revising the applicability to ensure consistent application of the requirements of this standard to dispersed power producing resources. 1 Anticipated Actions Anticipated Date Final ballot January 2015 BOT adoption February 2015 1 The terms dispersed generation resources and dispersed power producing resources are used interchangeably in Project 2014-01 because the former term was used in the Standards Authorization Request for the project, while the latter term is in line with terminology used in the revised definition of the BES. DRAFT Project 2014-01 January 13,September 10, Page 1 of

When this standard has received ballot approval, the text boxes within the Applicability section of the standard will be moved to the Application Guidelines Section of the standard. A. Introduction 1. Title: Coordination of Generating Unit or Plant Capabilities, Voltage Regulating Controls, and Protection 2. Number: PRC-019-21 3. Purpose: To verify coordination of generating unit Facility or synchronous condenser voltage regulating controls, limit functions, capabilities and Protection System settings. 4. Applicability: 4.1. Functional Entities 4.1.1 Generator Owner 4.1.2 that owns synchronous condenser(s) 4.2. Facilities For the purpose of this standard, the term, applicable Facility shall mean any one of the following: 4.2.1 Individual generating unit greater than 20 MVA (gross nameplate rating) directly connected to the Bulk Electric System. 4.2.2 Individual synchronous condenser greater than 20 MVA (gross nameplate rating) directly connected to the Bulk Electric System. 4.2.3 Generating plant/ Facility consisting of one or more units that are connected to the Bulk Electric System at a common bus with total generation greater than 75 MVA (gross aggregate nameplate rating). 4.2.3.1 This includes individual generating units of the dispersed power producing resources identified through Inclusion I4 of the Bulk Electric System definition where voltage regulating control for the facility is performed solely at the individual generating unit of the dispersed power producing resources. Rationale for Facilities section 4.2.3.1 For those dispersed power producing facilities that only perform voltage regulating control at the individual generating unit level, the SDT believes that coordination should take place at the individual generating unit level of the dispersed power producing resource level. These facilities need to consider the Protection Systems at the individual units and their compatibility with the reactive and voltage limitations of the units. Where voltage regulating control DRAFT Project 2014-01 January 13,September 10, Page 2 of

is done at an aggregate level, applicability is already included under Facilities section 4.2.3. 4.2.4 Any generator, regardless of size, that is a blackstart unit material to and designated as part of a Transmission Operator s restoration plan. 5. Effective Date: See the Implementation Plan for PRC-019-2this standard. 5.1. In those jurisdictions where regulatory approval is required: 5.1.1 By the first day of the first calendar quarter, two calendar years following applicable regulatory approval, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, each Generator Owner and shall have verified at least 40 percent of its applicable Facilities. 5.1.2 By the first day of the first calendar quarter, three calendar years following applicable regulatory approval, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, each Generator Owner and shall have verified at least 60 percent of its applicable Facilities. 5.1.3 By the first day of the first calendar quarter, four calendar years following applicable regulatory, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, approval each Generator Owner and shall have verified at least 80 percent of its applicable Facilities. 5.1.4 By the first day of the first calendar quarter, five calendar years following applicable regulatory approval, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, each Generator Owner and shall have verified 100 percent of its applicable Facilities. 5.2. In those jurisdictions where regulatory approval is not required: 5.2.1 By the first day of the first calendar quarter, two calendar years following Board of Trustees approval, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, each Generator Owner and shall have verified at least 40 percent of its applicable Facilities. 5.2.2 By the first day of the first calendar quarter, three calendar years following Board of Trustees approval, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, each Generator Owner and shall have verified at least 60 percent of its applicable Facilities. DRAFT Project 2014-01 January 13,September 10, Page 3 of

5.2.3 By the first day of the first calendar quarter, four calendar years following Board of Trustees approval, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, each Generator Owner and shall have verified at least 80 percent of its applicable Facilities. 5.2.4 By the first day of the first calendar quarter, five calendar years following Board of Trustees approval, or as otherwise made effective pursuant to the laws applicable to such ERO governmental authorities, each Generator Owner and shall have verified 100 percent of its applicable Facilities. B. Requirements R1. At a maximum of every five calendar years, each Generator Owner and Transmission Owner with applicable Facilities shall coordinate the voltage regulating system controls, (including in-service 2 limiters functions) with the applicable capabilities and settings of the applicable Protection System devices and functions. [Violation Risk Factor: Medium] [Time Horizon: Long-term Planning] 1.1. Assuming the normal automatic voltage regulator control loop and steady-state system operating conditions, verify the following coordination items for each applicable Facility: 1.1.1. The in-service limiters are set to operate before the Protection System of the applicable Facility in order to avoid disconnecting the generator unnecessarily. 1.1.2. The applicable in-service Protection System devices are set to operate to isolate or de-energize in order to limit the extent of damage when operating conditions exceed capabilities or stability limits. R2. Within 90 calendar days following the identification or implementation of systems, or setting changes that will affect the coordination described in Requirement R1, each Generator Owner and with applicable Facilities shall perform the coordination as described in. These possible systems, or settings changes include, but are not limited to the following [Violation Risk Factor: Medium] [Time Horizon: Long-term Planning]: Voltage regulating settings or changes; Protection System settings or component changes; Generating or synchronous condenser capability changes; or Generator or synchronous condenser step-up transformer changes. 2 Limiters or protection functions that are installed and activated on the generator or synchronous condenser. DRAFT Project 2014-01 January 13,September 10, Page 4 of

C. Measures M1. Each Generator Owner and with applicable Facilities will have evidence (such as examples provided in PRC-019 Section G) that it coordinated the voltage regulating system controls, including in-service 3 limiters functions, with the applicable capabilities and settings of the applicable Protection System devices and functions as. This evidence should include dated documentation that demonstrates the coordination was performed. M2. Each Generator Owner and with applicable Facilities will have evidence of the coordination required by the events listed in Requirement R2. This evidence should include dated documentation that demonstrates the tervals in Requirement R2 have been met. D. Compliance 1. Compliance Monitoring Process 1.1. Compliance Enforcement Authority The Regional Entity shall serve as the Compliance enforcement authority unless the applicable entity is owned, operated, or controlled by the Regional Entity. In such cases the ERO or a Regional entity approved by FERC or other applicable governmental authority shall serve as the CEA. 1.2. Evidence Retention The following evidence retention periods identify a period of time an entity is required to retain specific evidence to demonstrate compliance. For instances where the evidence retention specified below is shorter than the time since the last compliance audit, the Compliance Enforcement Authority may ask an entity to provide other evidence to show that it was compliant for the full time period since the last audit. Owner and shall retain evidence of compliance with Requirements R1 and R2, Measures M1 and M2 for six years. If a Generator is found non-compliant, the entity shall keep information related to the non-compliance until mitigation is complete and approved or for the time period specified above, whichever is longer. 3 Limiters or protection functions that are installed and activated on the generator or synchronous condenser. DRAFT Project 2014-01 January 13,September 10, Page 5 of

The Compliance Enforcement Authority shall keep the last periodic audit report and all requested and submitted subsequent audit records. 1.3. Compliance Monitoring and Assessment Processes Compliance Audit Self-Certification Spot Checking Compliance Investigation Self-Reporting Complaint 1.4. Additional Compliance Information None 2. Violation Severity Levels R # Lower VSL Moderate VSL High VSL Severe VSL R1 R2 coordinated more than 5 calendar years but less than or equal to 5 calendar years plus 4 months after the previous coordinated more than 90 calendar days but less than or equal to 100 calendar days following the coordinated more than 5 calendar years plus 4 months but less than or equal to 5 calendar years plus 8 months after the previous coordinated more than 100 calendar days but less than or equal to 110 calendar days following the DRAFT Project 2014-01 January 13,September 10, coordinated more than 5 calendar years plus 8 months but less than or equal to 5 calendar years plus months after the previous coordinated more than 110 calendar days but less than or equal to 0 calendar days following the failed to coordinate within 5 calendar years plus months after the previous failed to coordinate within 0 calendar days following the identification or implementation of a change in Page 6 of

identification or implementation of a change in or settings that affected the identification or implementation of a change in or settings that affected the identification or implementation of a change in or settings that affected the or settings that affected the E. Regional Variances None. F. Associated Documents Underexcited Operation of Turbo Generators, AIEE Proceedings T Section 881, Volume 67, 1948, Appendix 1, C. G. Adams and J. B. McClure., Protective Relaying For Power Generation Systems, Boca Raton, FL, Taylor & Francis, 2006, Reimert, Donald Coordination of Generator Protection with Generator Excitation Control and Generator Capability, a report of Working Group J5 of the IEEE PSRC Rotating Machinery Subcommittee IEEE C37.102-2006 IEEE Guide for AC Generator Protection IEEE C50.13-2005 IEEE Standard for Cylindrical-Rotor 50 Hz and 60 Hz Synchronous Generators Rated 10 MVA and Above Version History Version Date Action Change Tracking 1 February 7, 2013 Adopted by NERC Board of Trustees New 1 March 20, 2014 FERC Order issued approving PRC- 019-1. (Order becomes effective on 7/1/16.) 2 TBD Adopted by NERC Board of Trustees Standard revised in Project 2014-01: Applicability revised to clarify application of requirements to BES dispersed power producing resources DRAFT Project 2014-01 January 13,September 10, Page 7 of

G. Reference Examples of Coordination The evidence of coordination associated with may be in the form of: P-Q Diagram (Example in Attachment 1), or R-X Diagram (Example in Attachment 2), or Inverse Time Diagram (Example in Attachment 3) or, Equivalent tables or other evidence This evidence should include the capabilities and the operating region for the limiters functions Equipment limits, types of limiters functions which could be coordinated include (but are not limited to): Field over-excitation limiter and associated protection functions. Inverter over current limit and associated protection functions. Field under-excitation limiter and associated protection functions. Generator or synchronous condenser reactive capabilities. Volts per hertz limiter and associated protection functions. Stator over-voltage protection system settings. Generator and transformer volts per hertz capability. Time vs. field current or time vs. stator current. NOTE: This listing is for reference only. This standard does not require the installation or activation of any of the above limiter or protection functions. For this example, the Steady State Stability Limit (SSSL) is the limit to synchronous stability in the under-excited region with fixed field current. On a P-Q diagram using Xd as the direct axis saturated synchronous reactance of the generator, Xs as the equivalent reactance between the generator terminals and the DRAFT Project 2014-01 January 13,September 10, Page 8 of

infinite bus including the reactance of the generator step-up transformer and Vg as the generator terminal voltage (all values in per-unit), the SSSL can be calculated as an arc with the center on the Q axis with the magnitude of the center and radius described by the following equations C = V 2 g/2*(1/xs-1/xd) R = V 2 g/2*(1/xs+1/xd) On an R-X diagram using Xd as the direct axis saturated synchronous reactance of the generator, and Xs as the equivalent reactance between the generator terminals and the infinite bus including the reactance of the generator step-up transformer the SSSL is an arc with the center on the X axis with the center and radius described by the following equations: C = (Xd-Xs)/2 R = (Xd+Xs)/2 DRAFT Project 2014-01 January 13,September 10, Page 9 of

Regulating Controls, and Protection Section G Attachment 1 Example of Capabilities, Limiters and Protection on a P-Q Diagram at nominal voltage and frequency DRAFT Project 2014-01 January 13,September 10, Page 10 of

Regulating Controls, and Protection Section G Attachment 2 Example of Capabilities, Limiters, and Protection on an R-X Diagram at nominal voltage and frequency DRAFT Project 2014-01 January 13,September 10, Page 11 of

Regulating Controls, and Protection Section G Attachment 3 - Example of Capabilities, Limiters, and Protection on an Inverse Time Characteristic Plot DRAFT Project 2014-01 January 13,September 10, Page of