RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Similar documents
RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

kv: medium voltage reeling cable with fibreoptics

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

ABOUT US ABOUT US 1 CRANE CABLES

Electric cables. Cranes

Outdoor, CCTV or CCTV, Fig 8 Armored.

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Fiber Optic Outside Plant Cables (4-144 Fibers)

Outdoor, Fig 8 Armored, Multi Tube

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Ø 1250 * 688 mm 93 kg ± 105m

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

SUBMERSIBLE PUMP CABLES

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

Ø560*336mm 4.25 kg 2100 ± 105m

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

MULTIMEDIA & DATA TRANSMISSION

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

Marine Cables General Catalogue

Medium Voltage Power Cables

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

NETWORK CONNECTIVITY SYSTEMS

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Selection table for flat & ribbon cables

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Welding Cables Rubber Insulated

Ship and Offhsore. Approved cables for ship- and offshoreindustry

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

H07RN-F BS EN Flexible Rubber Cable

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

Outside Plant All Dielectric

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

CIR (Crush & Impact Resistant) VFD Power Cable

COPPER + LWL RAW CABLES

features and benefits

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

Tri-Rated Flexible PVC Equipment Wire

Complete, innovative cables range for shipbuilding industry

Optical Ground Wires (OPGW)

TRAXLINE CABLES FOR MOTION

Optical Systems Contents

SPECIFICATION. Optical Fiber Cable

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Conductix-Wampfler Cables for Festoon Systems, Energy Guiding Chains & Others

T E C H N I C A L D A T A for

Single-Armored Cables, Fibers

Books: 1. Data communications by William L Schweber 2. Data communication and Networking by Behrouz A F0rouzan

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

Multi-gigabit intra-satellite interconnects employing multi-core fibers and optical engines

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Standard Monotube SAFE

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

Armoured Power and Control Cables Fire Resistant

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

FLEXIBLE MULTI CORE CABLES

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C

Armoured Power and Control Cables to BS7917

RADIALL DETAIL SPECIFICATION FOR SHF COAXIAL CABLE

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

Kerman & Kavian Cable Industries ( KCI )

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

Connection technology for wireless communication systems

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

CAT 5e UTP Cable: NETSET BOX [305m], indoor

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

Installation Recommendations

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

Nufern 980 nm Select Cut-Off Single-Mode Fiber

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

TABLE OF CONTENTS NEW!!

DNVGL-CP-0400 Edition December 2015

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Transcription:

HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 1

HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents Type Page Screened / Unscreened cable types Application / design 1-2 RHEYCORD(RTS) (N)SHTOEU-J 3 +3 /3 3 4 RHEYCORD(RTS) (N)SHTOEU-J N Q 5 6 RHEYCORD(RTS) (N)SHTOEU-J N Q + 5Q CE 7 RHEYCORD(RTS) (N)SHTOEU-J N 2.5 + OFE 8 Technical properties optical fibre elements 9 11 Samples for customized reeling cables RHEYCORD(RTS) 12 Technical & electrical properties 13 15 N = no. of cores Q = cross-section [mm²] REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 2

Fleible cables acc. to german standards To indicate the conformity to a relevant cable standard in Germany the starting letter >N< is used. A selection of essential letters indicating: - insulation material, cable design, construction elements - special properties, sheath material - manufacturer letter codes In the following you find an overview of these letter code. Cable design / letter code Letter code Eplanation (N) in line with DIN VDE 0250 part 814 SHT heavy duty rubber insulated fleible reeling cable type OE oil-resistant U flame retardant -J With green yellow protective core (RTK) Neans letter code for cable version with special cold fleible compounds (RTS) Neans letter code for cable version with optimized wall thicknesses OFE Optical fibre element /2 Ground conductor cross-section split into two parts /3 Ground conductor cross-section split into three parts CE Screened single cores Insulation material Special elastomeric hard grade ethylene-propylene rubber (HEPR) compound acc. to IEC 60502-1, developed for optimized insulation wall thickness. Sheath materials Inner / Outer sheath: chlorinated heavy duty rubber compound type 5GM5 acc. to DIN VDE 0207 part 21, oil resistant acc. to EN 60811-2-1, flame retardant acc. to DIN EN 60332-1-2. Application Heavy duty rubber reeling cable for control and power supply. For applications with high mechanical stress, especially for simultaneous tensile and torsional stress. Suitable for all types of mobile equipment such as stackers/reclaimers, cranes with motor-driven mono spiral / cylindrical reels, spring-operated reels and hoisting systems. RHEYCORD (RTS) (N)SHTOEU-J 0.6/1 kv 3 Q + 3 Q GC.../3 Q = cross-section main cores Q GC = cross-section Ground conductor 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 3

Design 1 2 3 4 5 Phase core (1) Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, core colour: black, grey, brown Protective conductor (2) Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, core colour: green-yellow Cabling Three cores laid-up over rubber centre element with the divided protected cross-section in the interstices Inner sheath (3) Etruded sheath, heavy duty rubber compound type 5GM5 acc. DIN VDE 0207 part 21, filling the interstices Reinforcement (4) Embedded braid made of synthetic threads with very high tensile load Outer sheath (5) Heavy duty chlorinated rubber compound quality 5GM5, colour: yellow, inkjet marking e.g.: RHEYCORD(RTS) (N)SHTOEU-J 350+325/3 0.6/1 kv I NEXANS I year Rated voltage: 0.6/1 kv Ma. permissible operating voltage U bma AC systems: 1.2 kv Ma. permissible operating voltage U bma DC systems: 1.8 kv Test voltage: 3 kv A.C. Type - No.: Cross-section Ma. conductor resistance at 20 C min. Outer-Ø ma. Weight appro.: Ma. permissible tensile load [mm²] [Ω/km] [mm] [mm] [kg/km] [N] 79986034 335+325/3 0.554 31.5 33.5 2030 3150 79986050 350+325/3 0.386 33 36 2475 4500 79986070 370+335/3 0.272 39 41 3445 6300 79986062 395+350/3 0.206 43 46 4225 8550 79986056 3120+370/3 0.161 46 49 5150 10800 79986057 3150+370/3 0.129 53 56 6460 13500 79986058 3185+395/3 0.106 58 61 7890 16650 79986227 3240+3120/3 0.0801 67 69 10605 21600 79986229 3300+3150/3 0.0641 71 74 12350 27000 Other cross-section on request RHEYCORD (RTS) (N)SHTOEU-J 0.6/1 kv Control cables N Q N = no. of cores Q = cross-section main cores 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 4

Design Cores Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, white cores with black no. 1 to n Protective conductor Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, core colour: green-yellow Cabling N cores laid-up over rubber centre element with different layer systems Inner sheath Etruded sheath, heavy duty rubber compound type 5GM5 acc. to DIN VDE 0207 part 21, filling the interstices Reinforcement Embedded braid made of synthetic threads with very high tensile load Outer sheath Heavy duty chlorinated rubber compound quality 5GM5, colour: yellow, inkjet marking e.g.: RHEYCORD(RTS) (N)SHTOEU-J 416 0.6/1 kv I NEXANS I year Rated voltage: 0.6/1 kv Ma. permissible operating voltage U bma AC systems: 1.2 kv Ma. permissible operating voltage U bma DC systems: 1.8 kv Test voltage: 3 kv A.C. Type - No.: Cross-section Ma. conductor resistance at 20 C min. Outer-Ø ma. Weight appro.: Permissible tensile load [mm²] [Ω/km] [mm] [mm] [kg/km] [N] 79981304 41.5 12 15 200 180 79981305 51.5 13.5 15.5 260 225 79981307 71.5 15 17 320 315 13.3 79981312 121.5 18 21 445 540 79981318 181.5 21 24 610 810 79981324 241.5 25 28 860 1080 79981404 42.5 13 15 270 300 79981405 52.5 14.5 16 335 375 79981407 72.5 17.5 19.5 450 525 79981412 122.5 20 23 620 900 79981418 182.5 2.5 24 26 870 1350 79981424 242.5 27 30 1185 1800 79981430 302.5 29 32 1265 2250 79981436 362.5 31 33 1525 2700 79981444 442.5 34 37 1900 3300 Other cross-section on request RHEYCORD (RTS) (N)SHTOEU-J 0.6/1 kv Power Cables N Q N = no. of cores Q = cross-section main cores 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 5

Design Cores Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, white cores with black no. 1 to n Protective conductor Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, core colour: green-yellow Cabling N cores laid-up over rubber centre element with different layer systems Inner sheath Etruded sheath, heavy duty rubber compound type 5GM5 acc. to DIN VDE 0207 part 21, filling the interstices Reinforcement Embedded braid made of synthetic threads with very high tensile load Outer sheath Heavy duty chlorinated rubber compound quality 5GM5, colour: yellow, inkjet marking e.g.: RHEYCORD(RTS) (N)SHTOEU-J 416 0.6/1 kv I NEXANS I year Rated voltage: 0.6/1 kv Ma. permissible operating voltage U bma AC systems: 1.2 kv Ma. permissible operating voltage U bma DC systems: 1.8 kv Test voltage acc. DIN VDE 0250 part 814: Power: 2.5 kv A.C. Control: 2.0 kv D.C. Type-no.: Cross-section Ma. conductor resistance at 20 C min. Outer-Ø ma. Weight appro. Permissible tensile load [mm²] [Ω/km] [mm] [mm] [kg/km] [N] 79981504 44 15 17 340 480 4.95 79981505 54 17 19 450 600 79981604 46 18 20 500 720 79981605 56 3.30 19 21 590 900 79981313 126 28 31 1260 2160 79981704 410 1.91 20 22 710 1200 79981804 416 1.21 23.5 26 1060 1920 79981854 425 0.780 29 31 1560 3000 79981856 435 0.554 32 34 2090 4200 79981955 450 0.386 36 39 2900 6000 79981683 3120 0.161 47 50 5000 10800 79981881 5150 0.129 65 68 9800 22500 Other cross-section and nominal voltages on request RHEYCORD (RTS) (N)SHTOEU-J Control cables with screened cores 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 6

Design 252.5+51CE 9(21)C Cores Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, white cores with black no. 1 to n; Screen: copper wire serving, appro. 85 % covering; twisted pairs, copper wire serving, covering appro. 85 % Protective conductor Conductor: copper, plain, fleible stranded acc. DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded. ozone-resistant HEPR compound acc. to IEC 60502-1, core colour: green-yellow Cabling N cores laid-up over rubber centre element with different layer systems Inner sheath Etruded sheath, heavy duty rubber compound type 5GM5 acc. to DIN VDE 0207 part 21, filling the interstices Reinforcement Embedded braid made of synthetic threads with very high tensile load Outer sheath Heavy duty chlorinated rubber compound quality 5GM5, colour: yellow, inkjet marking e.g.: RHEYCORD(RTS) (N)SHTOEU-J 192.5+51 CE 0.6/1 kv I NEXANS I year Rated voltage: 0.6/1 kv Ma. permissible operating voltage U bma AC systems: 1.2 kv Ma. permissible operating voltage U bma DC systems: 1.8 kv Test voltage: 3 kv A.C. Type - No.: Cross-section Ma. conductor resistance at 20 C min. Outer-Ø ma. Weight appro.: Permissible tensile load [mm²] [Ω/km] [mm] [mm] [kg/km] [N] 79981001 192.5 + 51 CE 2.5 mm²: 7.98 26 29 1090 1575 7998 192,5+51,5 CE 1 mm²: 19.5 27 30 1190 1575 79981002 252.5 + 51 CE 1,5 mm²: 13.3 29 31 1305 2025 79981003 6(21)C 26 28 815 360 19.5 79981004 9(21)C 31 33 1220 540 Other cross-section on request RHEYCORD (RTS) (N)SHTOEU-J N 2.5 + OFE... 0.6/1 kv N = no. of cores 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 7

Design 122.5+OFE12G62.5/125 Cores Conductor: copper, plain, fleible stranded acc. to DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded, ozone-resistant HEPR compound acc. to IEC 60502-1, white cores with black no. 1 to n; Protective conductor Conductor: copper, plain, fleible stranded acc. to DIN EN 60228 class 5 Insulation: elastomeric insulation made of dielectric and thermal high graded, ozone-resistant HEPR compound acc. to IEC 60502-1, core colour: green-yellow Cabling N cores laid-up over OF-element (see page 10-12) in layer system Inner sheath Etruded sheath, heavy duty rubber compound type 5GM5 acc. to DIN VDE 0207 part 21, filling the interstices Reinforcement Embedded braid made of synthetic threads with very high tensile load Outer sheath Heavy duty chlorinated rubber compound quality 5GM5, colour: yellow, inkjet marking e.g.: RHEYCORD(RTS) (N)SHTOEU-J 242.5+OFE12E9/125 0.6/1 kv I NEXANS I year Rated voltage: 0.6/1 kv Ma. permissible operating voltage U bma AC systems: 1.2 kv Ma. permissible operating voltage U bma DC systems: 1.8 kv Test voltage acc. DIN VDE 0250 part 814: Power: 2.5 kv A.C. Control: 2.0 kv D.C. Type-no.: Cross-section Ma. conductor resistance at 20 C min. Outer-Ø ma. Weight appro.: Permissible tensile load [mm²] [Ω/km] [mm] [mm] [kg/km] [N] 79981414 122.5+OFE24 23 25 755 900 8.21 79981445 342.5+OFE24 34 37 1740 2550 Other cross-section and nominal voltages on request HEAVY DUTY HYBRID REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J OFE 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 8

Optical fibre characteristics Colours of the fibres acc. ANSI/TIA/EIA 598-A 62.5/125 fibres acc.: TIA/EIA-492AAAA-A and IEC/CEI 60793-2-10 type A1b, OM1 fibre type (TIA) HEAVY DUTY HYBRID REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J OFE 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 9

Description et applications Multimode Fibre 50/125 La fibre multimode est optimisée pour les réseau locau (LAN). Son gradient d indice permet des transmissions à haut débit (Ethernet, Gigabit Ethernet et 10 Gigabit Ethernet). Elle est protégée par une gaine à 250µm. La fibre est totalement conforme au standards ITU-G.651 et OM. Caractéristiques Construction Coeur en silice dopé 1: Coeur Large cœur pour connectorisation aisée 2: Protection 3: Gainage Dimensions nominales & paramètres techniques Optiques Dimensions Characteristics Attenuation (db/km) Nom. Ma. Modal bandwidth (Mhz.km) 850 nm/1300 nm Effect. Modal BW (Mhz.km) 850 nm Applicative length (m) 100 Mbps (SX/FX) 1 Gbps (SR/LX) 10 Gbps (SR/LX4) 40 Gbps (SR4) 100 Gbps (SR10) 850 nm 2.6 3.0 600 NA 550 630 110 NA NA OM2 (+) Gigalite II Attenuation uniformity (db) 0.2 Numerical aperture 0.20 ± 0.015 Core - (µm) 50 ± 2.5 Cladding - (µm) 125 ± 1 Core non circularity (%) < 6 Primary coating - (µm) 250 ± 15 Cladding non circularity (%) < 2 Concentricity error (µm) 1.5 Proof test (%) 1 1300 nm 0.8 1.0 1200 NA (1) 1200 - NA NA 50/125 fibres acc.: TIA/EIA-492AAAB and IEC/CEI 60793-2-10 type A1a.1, ITU-T G.651.1, OM2 fibre type (TIA) HEAVY DUTY HYBRID REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J OFE 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 10

E9/125 fibres acc.: Reference standard ITU-T G.652D Samples of tailored/customized cable types: 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 11

RHEYCORD (RTS) (N)SHKTOEU-J (N)SH 3150+270/2+110+OFE12E9/125 0.6/1 kv Power supply on cylindrical reel / copper process plant RHEYCORD (RTS) TS) (N)SHKTOEU-J (N)SHKTOEU 3185+195+2(72.5)C+OFE12E9/125 FE12E9/125 0.6/1 kv Power supply on mono spiral reel Ø 68 71 mm appro.: 9680 kg/km 30 m/min travel speed RHEYCORD (RTS) (N)SHTOEU RHEY HTOEU-J 0.6/1 kv 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 12

Electrical data Current-carrying capacity in ampere [A] @ 30 C ambient temperature acc. DIN VDE 0298-4 on ground: Short circuit current capacity [ka]: (80 250 C/I thr = 149 A/mm²) tkr Ithz = Ithr tk Cross-section [A] [mm²] 1 18 1.5 23 2.5 30 3.5 33 4 41 6 53 10 74 16 99 25 131 35 162 50 202 70 250 95 301 120 352 150 404 185 461 240 553 300 641 Cross-section [mm²] 1 s (t kr) 0.5 s (t k) 0.2 s (t k) 1 0.1 0.2 0.3 1.5 0.2 0.3 0.5 2.5 0.4 0.5 0.8 3.5 0.5 0.7 1.2 4 0.6 0.8 1.3 6 0.9 1.3 2.0 10 1.5 2.1 3.3 16 2.4 3.4 5.3 25 3.7 5.3 8.3 35 5.2 7.4 11.7 50 7.5 10.5 16.7 70 10.4 14.8 23.3 95 14.2 20.0 31.7 120 17.9 25.3 40 150 22.4 31.6 50 185 27.6 39.0 61.6 240 35.8 50.6 80 300 44.7 63.2 100 Thermal properties Permissible temperature on cable surface - static: -40 C / +80 C - reeling operation: -30 C / +80 C - reeling operation: -45 C / +80 C with special cold fleible rubber compound Ma. conductor temperature: 90 C Ma. short-circuit temperature of conductor: 250 C Correction factor for ambient temperatures other than 30 C to be applied to the current-carrying capacities for cables in the air acc- DIN VDE 0298-4 (permissible conductor temperature 90 C) 10 C 20 C 30 C 40 C 50 C 60 C 70 C 1.15 1.08 1.00 0.91 0.82 0.71 0.58 HEAVY DUTY HYBRID REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J OFE 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 13

Bending radii Smallest permissible bending radius acc. DIN VDE 0298-3: Outer- ( D ) of the fleible cable [mm] up to 8 8 12 12 20 over 20 Fied installed 3 D 3 D 4 D 4 D Free movement 3 D 4 D 5 D 5 D Reeling application 5 D 5 D 5 D 6 D Deflection pulleys 7.5 D S-shaped track curves 20 D Correction factor for reeled fleible cables acc. DIN VDE 0298-4 No. of layers 1 2 3 4 5 Factor 0.80 0.61 0.49 0.42 0.38 Mono spiral reel 0.80 De-rating factors for multi-core cables up to 10 mm² acc. DIN VDE 0298-4 No. of loaded cores 5 7 10 14 19 24 40 61 Correction factor 0.75 0.65 0.55 0.50 0.45 0.40 0.35 0.30 Voltage drop Voltage drops are determined by using the following formula: = (cos+ sin) With: Δu Voltage drop (in volts) b Coefficient equal to 3 for three-phases circuits, or 2 for single-phase circuits R Electrical resistance of conductors in normal service (in Ω/km) I Straight length of the wiring systems (in km) cos Power factor, if no precise details, the power factor is taken equal to 0,8 ( sin = 0,6 ) λ Reactance per unit length of conductors (in Ω/km) ib Current value ( in Ampere) HEAVY DUTY HYBRID REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J OFE 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 14

For a fast calculation of the section it is recommended to use the following table which give the value of the voltage drop, available for most of the low voltage cables and for different values of cos Low voltage cables with EPR insulation (ma. temperature @ conductor: 90 C), 3 or 4 copper cores Cross-section [mm²] Voltage drop [ V / A km ] cos = 1 cos =0,9 cos =0,8 cos =0,6 1,5 26,0 24,2 21,5 16,2 2,5 15,5 14,4 12,8 9,60 4 10,0 9,0 8,0 6,10 6 6,60 6,10 5,40 4,20 10 3,90 3,60 3,20 2,50 16 2,50 2,30 2,10 1,50 25 1,60 1,50 1,35 1,10 35 1,15 1,10 1,00 0,85 50 0,85 0,80 0,75 0,65 70 0,57 0,60 0,55 0,50 95 0,42 0,45 0,42 0,40 120 0,33 0,35 0,35 0,34 150 0,27 0,30 0,30 0,31 185 0,22 0,25 0,22 0,24 240 0,17 0,20 0,21 0,23 300 0,14 0,17 0,20 0,21 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 15

Global epert in cables and cabling systems With energy as the basis of its development, Neans, the worldwide leader in the cable industry, offers an etensive range of cables and cabling systems. The Group is a global player in the infrastructure, industry, building, Local Area Network and mining markets. Neans addresses a series of market segments from energy, transport and telecom networks to shipbuilding, oil and gas, nuclear power, automotive, electronics, aeronautics, handling and automation. With an industrial presence in 40 countries and commercial activities worldwide, Neans employs 25,000 people and had sales in 2015 of 4,6 billion. Neans is listed on NYSE Euronet Paris, compartment A. Neans may make changes to the technical specifications of its products, in particular to make improvements thereto or to ensure compliance with applicable laws and regulations. Neans Germany GmbH D-41238 Moenchengladbach Bonnenbroicher Str. 2-14 ML-I PM, heinz-willi.hamacher@neans.com Tel.: 0049 2166 27 2176 2017 RHEYCORD (N)SHT(RTS), 13.01.2017 16