ADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS

Similar documents
System for 2+ Level Buildings

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Ignitability Index Spread of Flame Index Heat Evolved Index Smoke Developed Index. Range 0-20 Range 0-10 Range 0-10 Range

General Installation Guidelines

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

The WANZ Guide to Window Installation

DW VERTICAL INSTALLATION

How To Install Windows: Nail-Fin Application

Vertical Slider Section Detail

INTERNAL LININGS INSTALLATION GUIDE

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

KS42 MF SERIES - HORIZONTAL INSTALLATION

900 SERIES WALL PANELS

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

DURAPLANK TM WEATHERBOARD

How-To-build guide Garden shed

SuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter

FD30 & FD60 FRAME & DOOR INSTALLATION GUIDE

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Before installation, check your local and state requirements for this type of install.

Providing 3 Layers of Protection

STOPOREN FACADE SYSTEM TIMBER WINDOW JOINERY - HEAD DETAIL

rondo exangle drywall finishing sections

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Extrusions GB-3-IN01. Updated: Scale: REV: - This Drawing is Protected by Copyright Altus NZ Ltd.

Mira Premium Series Bi-Parting French Sliding Patio Door Installation Instructions

Shaft Wall SYSTEMS 210 INSTALLATION 211. Shaft Wall systems are fire rated non-load bearing walls used for shafts and service ducts.

Column and Beam Fire Protection SYSTEMS 335 INSTALLATION 337 GENERAL REQUIREMENTS 337 FRAMING 337

Integrity Polygon and Round Top Installation and Finishing Instructions

IF INSTALLING ANY OF THE PORTMAN SELF CLOSING SYSTEMS, PLEASE READ THE CORRESPONDING FITTING INSTRUCTIONS SUPPLIED WITH THE CLOSING SYSTEM FIRST

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Gyproc Proflex Access Panels - Installation Guidance Notes

MULTI-STORY FIRE STOPPING ASSEMBLY FRAMED OPENING JAMB (LOW CELL) INDEX SHEET

Curtain Wall Installation Guide

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Horizontal Shaft Wall

Installation Guide. ExoTec TM Facade Panel And Fixing System COMMERCIAL

DW HORIZONTAL INSTALLATION

Installation Instructions

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

MAGNUM BOARD INTERIOR INSTALLATION GUIDELINES

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

method of build Komfire-75 partitioning system 75mm Steel Stud & Plasterboard Partitioning System with Square Aluminium Cover Trims KOMFORT

for Andersen 400 Series Woodwright Transom over 400 Series Woodwright Double-Hung or 400 Series Woodwright Picture Window

Pocket Door Installation Instructions

TECHNICAL SPECIFICATION

The better way to build TM. Installation Manual ROOF SIPs

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

Boxed Shed. QUAKER or A-FRAME SIZES: 6 x 8 6 x 10 T1-11Siding

FrameSaver Jamb Bottom Replacement Instructions

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

CERACLAD.

Installation Instructions

REDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions

SEAL PLATE SP4413 VERTICAL SP4414 1"[25] VERT. PANEL JTS. 1/2"[13] INTERM. SPLICES DESIGN LOADS AND SLAB EDGE DISTANCES. 1 2 NOM.

EXOTEC FACADE PANEL AND FIXING SYSTEM AUSTRALIA APRIL 2006 INSTALLATION MANUAL

UCO Vistabord Fixing Manual

DuraplankTM External Cladding

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

Block Frame Inovo Patio Door/Transom/Sidelite Field Mulling Instructions. simonton.com/installation. If mulling sidelites, skip to Step 5.

WINDOW INSTALLATION GUIDE

Contents. Multi Functions Board

Side Light Frame Pack Assembly Instructions

TEKTON WEATHERIZATION SYSTEM SPECIFICATION

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

SLIDING MECHANISM TROLLEY CATCH TROLLEY ASSEMBLY FLOOR GUIDE

Side Light Frame Pack Assembly Instructions

GENERAL INSTALLATION GUIDELINES

3M Air and Vapour Barrier 3015 Technical guide

GENERAL INSTALLATION GUIDELINES

GlasRoc Sheathing Type X

INSTALLATION INSTRUCTIONS SIDELITE ASSEMBLY SERIES 900 TERRACE DOOR AND SERIES 925 PATIO DOOR

4. Partially open the operating panel and tilt the top toward the interior of the door (Figure 4). Lift the panel off the sill and set it aside.

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL PIONEERING INSULATED METAL PANEL TECHNOLOGY

ASS 70 FD folding / sliding door. Installation Guide

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Innova. Concealed frame doorsets. Installation instructions

400 SERIES VERTICAL INSTALLATION

Site Preparation Information for:

COMPOSITE SIDING INSTALLATION GUIDE

Material List for Log Complete Packages

Indiana Limestone Company Honeycomb Panels

KS SERIES - VERTICAL INSTALLATION

BuildingEnvelope Oldcastle ( ) -

L:\Document Control\DR Drafting\Records\Royce\Facades\Plank\US BenchmarkTM By Kingspan 40% RGB Gold 2013.jpg FACADES - BRICK INDEX SHEET

Installation Guide for Andersen 400 Series Tilt-Wash Transom and 200 Series Narroline Transom Windows

Note. Returns are blocks / mouldings that have finished sides suitable for doors and windows as shown below. Surround return.

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

Acceptable Standards of Domestic Construction

Series Advanced and alternate. Installation Instructions

The Firestone QuickSeam Reinforced Perimeter Fastening Strip needs to be installed with appropriate fasteners at maximum centres of 300 mm.

Installation instructions: Elements Vulcan+ Newport Hector Cladding

BBS Rusticated & Splaycut Cavity System

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL


INSTALLATION INSTRUCTIONS

SPECIFICATION FOR. BRANZ Appraisal Certificate # 621 (2008)

Transcription:

ADGV_001_FASTPOS Panel Timber Frame 12mm from top edge 600mm MAX CTRS TIMBER STUDS 200 mm MAX CTRS 50mm from corner Fastener Positioning Scale 1:20 No. ADGV_001

ADGV_003_SHTEDGEPOS Centre line of Timber Stud 3mm EPDM Foam Gasket Strip Overlap sheet by 3mm beyond centre of the stud Panels Sheet Edge Positioning Scale 1:2 No. ADGV_003

ADGV_004_NAILFIXTIMBFRAME 18mm Panels Fibre Cement Nails EPDM Foam Gasket Strip F/C Nail Fixing-Timber Frame Scale 1:2 No. ADGV_004

ADGV_005_COUNTSCRWSTLFRAME 22mm Panels Flush Screw EPDM Foam Gasket Strip Countersunk Screw-Lightweight Steel Frame Scale 1:2 No. ADGV_005

ADGV_006_FLSHSCRWSTLFRAME Panels Screws-countersunk 1.5mm Finish with Epoxy EPDM Foam Gasket Strip Flush Screw-Lightweight Steel Frame Scale 1:2 No. ADGV_006

ADGV_010_SLABEDGEEAVEJUNC BGC Interior Liningboard Timber Frame Damp Course Slab Edge/Eave Junction Scale 1:2 No. ADGV_010

ADGV_011_EXTCNRSEAL Flashing Bond Breaker Tape (supplied by others) External Corner-Sealant Option Scale 1:2 No. ADGV_011

ADGV_012_EXTCNRSTL Flashing BGC External Corner Angle Date Nov 2014 External Corner-Aluminium Scale 1:2 No. ADGV_012

ADGV_013_INTCNRSEAL Panels Flashing Bond Breaker Tape (supplied by others) Double Stud Timber Framing Internal Corner-Sealant Option Scale 1:2 No. ADGV_013

ADGV_014_INTCNRSTL Panels Flashing BGC Internal Corner Angle Double Stud Timber Framing Date Nov 2014 Internal Corner-Aluminium Scale 1:2 No. ADGV_014

ADGV_015_WINHEAD Timber Framing BGC Optional trim (supplied by others) Packer (as required) Flashing Aluminium window joinery Date Nov 2014 Window Head Scale 1:2 No. ADGV_015

ADGV_016_WINSILL Aluminium window joinery Packer (as required) Flashing Optional trim (supplied by others) BGC Timber Framing Date Nov 2014 Window Sill Scale 1:2 No. ADGV_016

ADGV_017_WINJAM Aluminium Window Continuous Bead of Sealant Trim (supplied by others) Panels Date Nov 2014 Window Jamb Scale 1:2 No. ADGV_017

ADGV_018_VERTBUTJOINT 1mm Panels EPDM Foam Gasket Strip Vertical Butt Joint Scale 1:2 No. ADGV_018

ADGV_019_LWRFLRJNC Flooring Floor joist Damp Course 20-25mm overlap Lower Floor Junction Scale 1:2 No. ADGV_019

ADGV_020_UPFLRJNC 17mm BGC Horizontal Flashing 15mm Flooring Floor joist Upper Floor Junction Scale 1:2 No. ADGV_020

ADGV_021-UPFLRJNC2 Architectural profile or similar 17mm BGC Horizontal Flashing 15mm Flooring Floor joist Upper Floor Junction- Option 2 Scale 1:2 No. ADGV_021

ADGV_022_HORIZJNC1 Timber Stud Suitable flashing (supplied by others) 10mm Damp Course Masonry Wall Horizontal Junction-1 Scale 1:2 No. ADGV_022

ADGV_023_HORIZJNC2 Timber Stud Suitable flashing (supplied by others) 20mm Masonry Wall Horizontal Junction-2 Scale 1:2 No. ADGV_023

ADGV_024_BNDRYWALLSYS 10mm BGC Plasterboard Timber Frame & EPDM Foam Gasket 16mm BGC Wet Area Fireboard (1 or 2 layers) BGC Boundary Wall System Scale 1:2 No. ADGV_024

ADGV_025_THERMALBREAKS Steel Framing EDPM Foam Gasket Vapour Permeable Sarking Durascape Date Nov 2014 Thermal Breaks Scale 1:20 No. ADGV_025