Surgitron Dual Frequency 4.0 MHz Radiowave Technology

Similar documents
Instruction Manual. (English-English)

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

radiosurg One device for all surgical treatments!

Andy Falconer. Principles of surgical diathermy

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

PINXEL. Micro Needle Rf & Fractional Rf

Electrosurgery Units (ESU s) and their variants

SANO. Pinxel Introduction

perioperativecpd.com The basics of diathermy

Low / Medium Power Electrosurgery Review 2002

MEDICAL/SURGICAL CUTTING INSTRUMENTS

ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

surtron.com SURTRON ELECTROSURGICAL units

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

Electrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood

SCANLAN LEGACY. High Precision Titanium Instruments

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

LED EXAM, PROCEDURE & SURGERY LIGHTS

ALSATOM SU MPC SU 50 MPC SU 100 MPC SU 140 MPC SU 140/D MPC SU 140/BD MPC

Electrosurgery. KLS Martin ME MB 2 SAFETY BY EASY USE

Radio Frequency Electrosurgical System Specialist

Expertise in Surgery.

GYN Scissors - Z-Type Hysterectomy & Parametrium

Eleven Pearls for Cosmetic Earlobe Repair

E N O V A n e e d l e s

DSL# EC 2009 Ethicon Endo-Surgery. All rights reserved PRODUCT CATALOG

Leksell Neuro Generator

ELECTROSURGICAL GENERATOR USER S GUIDE

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

Electrosurgery. KLS Martin ME 102. The compact Electrosurgical Unit with high Capacity

Novosyn Quick Your fast and efficient solution for a better quality of life

CO 2 Laser. AcuPulse. with SurgiTouch. Automation System. An Evolution in Automated Laser Surgery. Surgical: AcuPulse CO 2 Laser

An Alternative Technique to Perform Surgeriesin Hospital by Surgical Diathermy

What tests should be done?

ETHICON Wound Closure Suture Products. ETHICON Wound Closure Suture Products. International Market Development

DERM 941 DERM 942 High-Frequency Desiccators

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

MINIMAL ENERGY. MAXIMUM PRECISION. 1,2, The newest addition to Valleylab energy made to enhance the performance of your electrosurgical handpieces1,2,

USER S GUIDE. User s Guide Bovie IDS-400

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

4-dimensional surgical lighting. Surgical lighting

RF leakage current in electrosurgical units: Influence of the layout in taking measurements

STILLE Micro Instruments. Solid Performance - Outstanding Precision

User s Guide Aaron 940

Wide range in small dimensions

MEDICAL & LIFE SCIENCES

Current-Programmed Mode Control Strategies for Electrosurgical Generators

5th Metatarsal Fracture System Surgical Technique

ENT /2017-E. BEHRBOHM Instruments. for Revision Surgery of the Nose

RF Amplifiers and RF Heating for Medical Applications FTF-IND-F0690

4-dimensional surgical lighting. Surgical Lighting

HF- GENERATORS.

Laser Glasses

ERBE ERBOTOM ICC 300. Instruction manual 08.00

Our combined competences in medical endoscopy systems provide global solutions. From

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM

Neurosurgery with ultrasonic technology by Söring: fine preparation and effective dissection

Optical coherence tomography

BOVIE SURGI-CENTER PRO. Electrosurgical Generator. User's Guide

User s Guide Aaron 950

Cost savings without compromise

QA-ES III Electrosurgical Analyzer

Photoacoustic Imaging of Blood Vessels in Tissue

Figure 1. Relative intensity of solar energy of different wavelength at the earth's surface.

GeoSpec2 core analysis

INTELECT SHORTWAVE DIATHERMY MOVING REHABILITATION FORWARD

Brighten your Expertise

Light Microscopy. Upon completion of this lecture, the student should be able to:

Light has some interesting properties, many of which are used in medicine:

Application Notes. Electrosurgical Analyzer Primer

Optimal Pupil Design for Confocal Microscopy

Next-Generation Fractional CO2 Emerges. Annual Practice Survey Results Review of Autologous Treatments AAD 2011 Exhibitor Highlights THE

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

Scanning Electron Microscopy. EMSE-515 F. Ernst

tevdek ii the specialist green, polyester, braided suture material With special ptfe coating indications needle OVeRVieW ROunD bodied needles

What Type Of Light Microscope Is Used To View Large Objects Such As Flowers

Dental Sutures. Japanese quality for best results.

QA-ES III Electrosurgical Analyzer

No need for gain flatness compensation over 8 GHz band to realize published gain flatness.

Puritan Opti-Tranz and Opti-Tranz Plus Collection & Transport Systems

Micro Surgery Speciality Instrumentation

SA601 Low voltage LNA and mixer 1 GHz

HAZARDS OF NON-IONIZING RADIOFREQUENCY (RF) RADIATION

ARC 350 HF ELECTROSURGICAL GENERATOR SIMPLY SAFE

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

Blood Vessel Detection in Images from Laser-Heated Skin

ELEKTROTOM 610. Operating Instructions. Valid from version 1130

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

MINISILK FT MINISILK FT MEDICINE AND AESTHETICS. DEKA Pulsed Light: Light, Compact, Extremely Versatile

Scopis Hybrid Navigation with Augmented Reality

focused on implantable pulse generators for restoration of function in individuals paralyzed by stroke or SCI.

VA L U E A N A LY S I S B R I E F

Trust the Colors with Olympus True Color LED

MatrixMANDIBLE Preformed Reconstruction Plates. Preshaped to the mandibular anatomy.

Questions or Concerns about a Permanent Access? Let s Talk!

WHEN IT COMES TO SUTURING, EXPERIENCE MATTERS.

MICRO-TECH Disposable biopsy forceps.

Meg1 (with Ligasmart)

The Perfect Close. to your surgical procedure. PER F ORM ANC E through innovation

Effects of Mobile Phone Radiation onto Human Head with Variation of Holding Cheek and Tilt Positions

Transcription:

Surgitron Dual Frequency 4.0 MHz Radiowave Technology With over 50 years of experience, over 70 patents and more than 200 journal articles, Ellman is your trusted worldwide partner for surgical products and services. The patented Surgitron Dual Frequency unit represents advanced radiowave technology that provides unparalleled surgical control, precision, versatility and safety. The high frequency of 4.0 MHz minimizes heat dissipation and thus cellular alteration. Clinical Benefits Include: Reduced post-operative discomfort 1 Minimal scar tissue formation 2 Maximum readability of histologic specimen 3 Enhanced healing 4 Excellent cosmetic results 5 How Our Patented Radiowave Technology Works Cellular Radiowave Absorption High frequency Radiowave energy has a strong affinity for water. Targeted tissue / cell readily absorbs energy due to high water content. Intracellular pressure increases as water molecules expand. Volatilization results in cell conversion to vapor. Process emits steam which aids in coagulation. Cellular interaction enables meticulous precise dissection with tissue preservation.

The PRECISION you require with theversatility you need Empire microincision Needle Electrode (TEE327, 3/4" Length, Straight) Vari-Tip Wire Electrode Adjustable Cutting Wire (A8D) microinsulated Needle (H137,.003" Diameter) LLETZ Bayonet Electrode (W31) RAUP Electrode (H81A1) Bipolar Bayonet Turbinate (IEC-I6D) Mini Mono Stan RF Forceps (IEC-MJ11/M, 4.9" Length) ACe-Tip Non-Stick Forceps (ACBF-010, 3.5" Length) Hundreds of electrodes & accessories are available for most medical specialties. (See Product Catalog for full listing)

Five Distinct Waveforms for Optimum Results 1. Fully Filtered (Cut) 4. Fulguration Micro-smooth cutting Negligible lateral heat Minimal cellular destruction Best cosmetic results. Fastest healing 4.5 Ideal for skin incision and biopsy 2. Fully Rectified (Cut/Coag) Maximum penetration and hemostasis Ideal for intentional tissue destruction 5. Bipolar Cutting with hemostasis Ideal for sub-cutaneous tissue dissection and planing. Especially useful in vascular areas while producing minimal amounts of lateral heat and tissue damage Pinpoint, micro-coagulation Minimal charring or tissue necrosis Ideal for coagulation in and around critical anatomy 1.7 MHz 3. Partially Rectified (Hemo) Coagulation / Shrinkage Ideal hemostasis with controlled penetration For cutting with maximum hemostatic control Features and Benefits Patented Technology reflecting 50 years of innovation and enhancement Dual Frequency combining two optimized frequencies Monopolar (4.0 MHz) and Bipolar (1.7 MHz) for maximum surgical benefits for outstanding precision and control Digital Control Panel facilitates easy operation and a clear view of settings Solid State Circuitry for dependable and consistent energy emission Safety Indicators provide visual and auditory alerts Parameter Recall allows rapid set-up for subsequent procedures

Less Lateral Thermal Alteration and More Precision with the 4.0 MHz Extent of Tissue Damage in mm 1.00 0.75 0.50 TRANSMISSION ELECTRON MICROSCOPY SHOWING LATERAL THERMAL DAMAGE ON HUMAN OVIDUCTS BY DIFFERENT INSTRUMENTS Tissue Penetration Depth (cm) 250 200 150 100 50 0.25 0 0.1 1 10 100 0 Experts in Precision Surgery KTP-532 Laser Nd-YAG Laser CO2 Laser Electrocautery Electrosurgery Frequency (MHz) Reference - Olivar, AC, et al, Ann Clin Lab Sci. 1999 Oct-Dec; 29(4): p281-5. Ellman radiowave technology produces one-third the lateral thermal damage as compared to conventional electrosurgery Ellman radiowave technology produces one-half to one-third of the lateral thermal damage versus most lasers Source: Golio, JM, et al, RF and Microwave Applications and Systems, The RF and Microwave Handbook, p21-2. Years Surgitron Dual RF 4.0 MHz

CC10057 Rev A Dual (USA):Surgitron Dual RF 11/23/10 3:17 PM Page 1 The PRECISION you require with the VERSATILITY you need Dermatology Ear, Nose, and Throat (ENT) Facial Plastic Empire microincision Needle Electrode (TEE327, 3/4" Length, Straight) General Surgery Vari-Tip Wire Electrode Adjustable Cutting Wire (A8D) Advanced 4.0 MHz Radiowave Technology Gynecology Ophthalmology / Oculoplastics PRECISION VERSATILITY Oral / Maxillofacial Surgery Plastic Reconstructive microinsulated Needle (H137,.003" Diameter) Primary Care Podiatry LLETZ Bayonet Electrode (W31) Radiowave Technology Radiowave Technology RAUP Electrode (H81A1) Bipolar Bayonet Turbinate (IEC-I6D) Mini Mono Stan RF Forceps (IEC-MJ11/M, 4.9" Length) ACe-Tip Non-Stick Forceps (ACBF-010, 3.5" Length) Shown with Surgitron Dual RF, Surg-e-Vac and Cart Hundreds of electrodes & accessories are available for most medical specialties. Clinical Citations 1. Ericsson, E et al, The Laryngoscope (2007); vol 117, p654 2. Botero, G.E.S, J Otol Head Neck Surgery (1996); vol 24 (1), p69 3. Silverman, E.B etal, Veterinary Surgery (2007); vol 36, p50-56 4. Bridenstine, J.B., Derm Surgery (1998); vol 24, p397-400 5. Aferzon, M, Derm Surgery (2002); vol 28, p735-738 (See Product Catalog for full listing) ellman International, Inc. 3333 Royal Avenue, Oceanside, N.Y. 11572-3625 U.S.A. (800) 835-5355 (516) 594-3333 Fax: (516) 569-0054 www.ellman.com Note: Do not copy or distribute without written authorization from Ellman International, Inc. A 2010 Ellman International, Inc. All Rights Reserved. CC10057 Rev A 0413