WIND VANE THIES COMPACT

Similar documents
WIND VANE THIES COMPACT TMR

WIND VANE THIES FIRST CLASS 2014 TMR

WIND MONITOR ANEMO / WIND VANE YOUNG ALPINE

ANEMOMETER VECTOR A100L2 & VECTOR A100LK & VECTOR A100LM

ANEMOMETER WINDSENSOR P2546C-OPR

VERTICAL ANEMOMETER YOUNG GILL PROPELLER 27105T & 27106T

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter - compact

Wind Direction Transmitter - compact - with serial output x0.x00

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Wind Transmitter First Class

Wind Transmitter compact xx

Wind Transmitter First Class / 141 / / 141 / 161

Wind Transmitter compact xx

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Transmitter - compact

Wind Transmitter - with frequency output xx.xxx

User Manual CTP4/8/16

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

A-LAS Series A-LAS-F12. Design. A-LAS Series Analog Laser Light Barriers. Product name: Accessories: (cf. page 5) A-LAS-F12-(aperture)*-(fork size)**

5-step-switch for adjustment of sensitivity (switching threshold) LED (super-bright, yellow) for switching state indication.

Combined Wind Transmitter - with analogue output xxx

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

5-pole M12 connector. Connecting cable: cab-m12/5-g-2m. LED (red) for dirt accumulation indication

Hygro-ThermoTransmitter-compact xxx

Manual Wind Monitor Instrument Model 6533A

Wind Transmitter - with analogue output xxx

OPERATING INSTRUCTIONS

The transducer component converts the measured signal and displays the actual value.

Telemetrie-Messtechnik Schnorrenberg

Torque Sensor. Torque. with Dual-Range-Option. Type 4503A...

Technical data. General specifications. Measurement range min max. 360

Technical data. Your advantages

Torque Sensor Series 3000 and Series 4000

ABSOLUTE ROTARY ENCODER SSI

Telemetrie-Messtechnik Schnorrenberg

Assembly Instructions

ph or ORP Transmitter

Series 7000 Torque Sensor for PTO-shafts

KMT - Kraus Messtechnik GmbH

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

LINEAR POTENTIOMETER. LZW Series. Key-Features:

Torque Sensor. Torque. Dual-Range Sensor with Brushless Transmission. Type 4503A...

DA DA 26 Technical Specification. Page 1/27. Volz Servos GmbH & Co. KG servos.com

ID/HX-EP SERIES DIGITAL OUTPUT

HX-EP SERIES DIGITAL OUTPUT

DAVIS ANEMOMETER MODBUS INTERFACE MODULE DA485. Manual. Pages 10

Sensor PAR xxx

KMT - Kraus Messtechnik GmbH

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

ABSOLUTE ROTARY ENCODER MULTI-TURN BIT PARALLEL

RoHS. Versatile. X d. XXXX a. XXXX e. c Output circuit depends on the encoder used. d Type of connection depends on the encoder used

ABSOLUTE ROTARY ENCODER CAN-BUS

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

IXARC Incremental Encoder UCD-IPT M100-PRD. Interface Programmable Incremental. Configuration Tool UBIFAST Configuration Tool (Version 1.6.

DA 30 High Torque Technical Specification

Data Sheet for Angle Sensors

WIND T H E W O R L D O F W E A T H E R D A T A

Digital flow transmitter for continuous flow measurement

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

Inductive Linear Position Sensor LI800P0-Q25LM0-LIU5X3-H1151

Actuator ID12. Product Data Sheet Feature

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Digital flow ELEMENT transmitter for continuous flow measurement

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

F T 742 NEW TOUGHEST WIND SENSORS THE WORLD S

ULTRASTAB I U Precision

This kind of information is useful to make reliable automatic control diagnostic and supervision systems. IS VS. Diameter of cylindrical types

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

FT702LT HEAVY DUTY WIND SPEED AND WIND DIRECTION IN ONE TOUGH PACKAGE FT702LT. series

PolyGard Digital Transmitter DGC DT-02

4-20mA, 0-10V and general process measuring bargraph displays

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

n Measurable displacements between n Linearity: max. ± 0.05 % n Housing diameter 12.9 mm n Service life: 10 8 movements

Technical data. General specifications. Linearity error ± 0.1 Electrical specifications Operating voltage U B

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Incremental Encoder Model: FOI58

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

DA DA

Digital inductive conductivity transmitter

WS12EX Position Sensor with Analog output Dust explosion-proof

A Revolution in Profile Measurement

Model 25B-F/S/L Solid Shaft Low Line Incremental Optical Rotary Encoder

2/2 way Proportional Valve (motordriven)

Transcription:

WIND VANE THIES COMPACT

ORDER - N O ELECTRICAL OUTPUT ELECTRICAL SUPPLY HEATING SUPPLY MODEL IN EOL MANAGER 4.3129.00.712 Pot: 2 kω 4.3129.10.712 Pot: 2 kω 4.3129.00.012A 4.3129.10.012A Pot: 2 kω Pot: 2 kω 0 24 VDC <1 ma 0 24 VDC <1 ma 0 24 VDC <1 ma 0 24 VDC <1 ma 24 V DC/AC 20 W No heating 24 V DC/AC 20 W No heating THIES 2K THIES 2K THIES 2K THIES 2K APPLICATION The wind direction transmitter (wind vane) is designed for the acquisition of the horizontal wind direction. The measuring value is output proportionally to wind direction as analogue voltage in case the potentiometer is supplied by a constant voltage. The measuring data available are ideally adapted to the supply in display instruments, recording instruments, data logger, as well as process control systems. For winter time use, the instrument is optionally equipped with an electronically regulated heating, in order to guarantee a smooth-running of the ball bearing and to prevent a blocking of the gap between the external rotation parts by ice aggregation. CONSTRUCTION AND MODE OF OPERATION The outer parts of the instrument are made of corrosion-resistant material (aluminum, stainless steel, plastic). The aluminum parts are additionally protected by means of an anodic coat. Labyrinth sealing protects sensitive parts inside the instrument against humidity. The wind direction is acquired by an inertia-free wind vane. The axis of the wind vane is held in ball bearings. A magnetic coupling connects the axis with the potentiometer in contact-free mode, thus providing for a smooth starting of the instrument.

TECHNICAL DATA CHARACTERISTIC Measuring range Resolution 0.5 DESCRIPTION / VALUE 0...360 (0 Ω in the North point) Starting threshold 1 m/s acc. to ASTM Standards D 5366-96 0.4 m/s acc. to VDI Directive 3786 Part 2 Delay distance <2.5 m acc. to ASTM Standards D 5366-96 Accuracy ±2 Measuring principle Potentiometer output Electrical supply for potentiometer Operating voltage heating Potentiometer 2 kω Ambient temperature -40...+70 C Survival speed Connection 4.3129.X0.712 4.3129.X0.012A Protection IP 55 Weight 4.3129.X0.712 4.3129.X0.012A Material: Housing Vane Bottom Voltage Us : 0...24 VDC The supply must guarantee a current limiting to maximum 1 ma short cut at the North point 24 V DC/AC, maximum 20 W 80 m/s, 30 minutes 7 pol. plug 3 wires, 0.25 mm 2, 100 mm long ca. 1.10 kg ca. 0.4 kg Aluminum (AlMgSi1) Synthetic with fiber glass (PC-GF10) Synthetic (POM H2320)

INSTRUCTIONS Use the following input channels on the logger to connect this sensor. See highligted input channels marked here below. The wire colors used in the connection diagram below only applies in case the cable is supplied by Kintech Engineering. For additional wiring & shielding information see the chapter IMPORTANT at the end of this dataheet. BAT ANEMOMETER INPUTS OUT DIGITAL INPUT 1 1 5V 2 3 4 5V 5 6 7 5V 8 9 10 3 2 1 8 7 6 5 4 3 2 1 SIG SIG 1 2 3 4 5 2 5 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 DIR 1 DIR 2 ANALOG INPUTS EXTRA ANALOG INPUTS DIGITAL INPUT 2 *See the chapter IMPORTANT WIND VANE Thies Compact (with heating) Signal cable Base sensor view / Soldering connector view Heating cable DATA LOGGER EOL Zenith HEATING SUPPLY SENSOR PIN DESCRIPTION (4.3129.X0.712) DATA LOGGER INPUT CHANNEL KINTECH COLOR CODES MANUFACTURER COLOR CODES (4.3129.X0.012A) 1 Do not connect! 3 4 2 7 5 1 6 2 GND DIR 1 (-) Brown Red 3 SIG DIR 1 SIG White Yellow 4 Us (+) DIR 1 (+) Green Blue 5 Do not connect! - Shield BAT GND Yellow - Green Yellow - Green 6 Heating (+) Heating Supply (+) Brown Green 7 Heating (-) Heating Supply (-) Blue Green Signal cable Heating cable

HOW TO CONNECT MORE THAN ONE OF THIS SENSOR WIND VANE 1 Thies Compact (with heating) Signal cable 1 WIND VANE 2 Thies Compact (with heating) Heating cable 1 Heating cable 3 Signal cable 2 Signal cable 3 Heating cable 2 WIND VANE 3 Thies Compact (with heating) DATA LOGGER EOL Zenith HEATING SUPPLY

SENSOR DIMENSIONS

HOW TO CONFIGURE THIS SENSOR IN EOL MANAGER Open EOL Manager and go to the data logger you are working on. Open the inputs tab and select the following type and model: Section: Wind Vanes Type: Windvane Model: THIES 2K Offset value: Tick the Std Cal if the north marking on the wind vane is aligned exactly towards North (in this case the offset is zero (0)). Otherwise the angle (in degrees) must be typed in the offset. SENSOR SELECTION MODEL SELECTION DATASHEET DOWNLOAD STANDARD CALIBRATION IMPORTANT After configuring the sensor in EOL Manager make sure to upload the configuration file to your EOL Zenith data logger. See the Quick User Guide how to upload configuration files to the data logger. All sensor wire shields must be connected to the data logger GND terminal. The data logger should always be connected to a separated ground rod. Not to the lightning rod of the tower. There are two exclusive inputs in the logger for the wind vanes (DIR1 & DIR2). Connecting the 3 rd 7 th wind vane use ANALOG INPUTS of the logger. Wind vanes connected to the ANALOG INPUTS of the logger must be connected to exclusive (+) and (-) terminals. The terminals (+) and (-) can consequently not be shared between wind vanes. Wind vanes cannot be connected to the EXTRA ANA- LOG channels of the logger. To store data such as Std Dev, Max and Min you should tick the corresponding boxes next to each anemometer channel when setting up your site file. Otherwise these parameters will not be stored. Connecting recommendation sensor-shield: Metallic measurement mast, grounded Metallic measurement mast, grounded Drawing of wind vane incl. isolator Drawing of wind vane without isolator Cable recommendation (up to 100 m cable): The shield should be connected to both the anemometer side and the data logger side Data logger should always be connected to ground The shield should only be connected on the data logger side Not on the sensor Data logger should always be connected to ground Sensor no heating Signal cable 3x0.5 mm 2 Sensor with heating Signal cable 3x0.5 mm 2 Heating cable 2x2.5 mm 2 Last modified: 24.05.2017

KINTECH ENGINEERING Tel. +34 976 221 789