Assembly instructions

Similar documents
Assembly instructions

Assembly instructions

Specification Tapped holes f. coupl Scope Allocation of the JED Numbers General...

CLAMPEX KTR 401 Operating/Assembly instructions. 1 Technical data 2

REPUTE tube fittings are manufactured to stringent quality control program and internal standards which

ADDUCO Hydraulic Clamping Nut

The object of these Operating Instructions is to assist you in the correct safe and economical use of the TORSIOMAX torque screwdriver.

HMZ Locknuts simple and reliable locking devices

ISO INTERNATIONAL STANDARD. Fasteners Torque/clamp force testing. Éléments de fixation Essais couple/tension. First edition

SPIETH Locknuts. Series MSW. Works Standard SN 04.03

KBS 40 Locking Device is a frictionally engaged detachable shaft-hub connection for cylindrical shafts and bores without keyway.

Operator's manual. TruTool N 200 (1A1) english

Technical Manual. ETP-CLASSIC incl type R. Content

Operator's manual. TruTool N 1000 (1B1) english

Installation and Operational Instructions for ROBA -DX Couplings Type 931.3

HEICO FASTENING SYSTEMS. Simple Fast Reliable HEICO-TEC TENSION NUT

25 TONNE HYDRAULIC PRESS MODEL NO: AHP 26

SAFETY PRECAUTIONS GENERAL INFORMATION

Magnetic Inductive Flow Sensor induq

Operating manual. TruTool N 500 (1A1) english

Check valve type RK and RB

USER MANUAL Nord-Lock X-series washers

Hydraulic Adapters (080201/ MS# 51820) (080202/ MS# 51815) (071502) (081602) (080203/MS# 51813)

Clamping bolts Eccentrical cams clamping units

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

Specification

Limited Warranty And Exclusive Remedy

FMG90 Series Electromagnetic Flow Meter

SCREW THREADS. = minor diameter. d 3. d 2. = pitch diameter

Design Guide. Original version of the design guide

Instruction manual for STA 1 sectional door operator

Installation and Operating Instructions for Shrink Discs RLK 608 and RLK 608 E E e

ISO INTERNATIONAL STANDARD. Fasteners Torque/clamp force testing. Éléments de fixation Essais couple/tension. First edition

RoAd And MineRAl technologies

INSTRUCTION MANUAL Q-HYDRAULIC

5000 Series Single Impeller Firefighter

Thread and End Connection

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

Instruction manual for STA 1 sectional door operator

Technical description

DODGE Grease Lubricated SPLIT-SPHER Roller Bearings and Pillow Blocks

WATERFLUX 3000 Quick Start

Operating Manual Riveting Tool R1. For installing blind rivet nuts

Gear racks. Standard and customised. Mounting instructions. Mounting instructions 2017

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

Powersafe Termination Guide

Manufacturing Instructions

LPK1550 Hydraulic Crimping Tool 15-ton

A cut above the rest The VOSSRingM cutting ring system

No November, Char-Lynn. Hydraulic Motor. Repair Information. R Series General Purpose Geroler Motor

Self-Centering Vise. Owner s Manual. Operating Instructions. Care & Maintenance. Warranty Information

Technical features. Positive Taper Lock System for manual tool clamping. Technical features:

HBS-AP ASSEMBLING INSTRUCTIONS

CENTAFLEX-A Assembly and operating instructions 008A GN, -GZ, -GB.. M EN Rev. 7

Visual Testing of Pipe Threads

TURBICUBE 1000 INSTRUCTIONS MANUAL. In-line turbidity transmitter TURBICUBE 1000 MES. From 0.1 to 1000 FNU. In-line turbidity transmitter /1

WATERFLUX 3000 Quick Start

TYPE 3740XL EXTRA LARGE WET RUNNING CARTRIDGE SPLIT SEAL

Page 1. SureMotion Quick-Start Guide: LACPACC_QS 1st Edition - Revision A 03/15/16

ASSEMBLY INSTRUCTIONS. Construction type approved Reg. no S819 F ENERGY AND SANITARY SYSTEMS

Product Information. AK ERM 2xx0 TTR ERM 2x00 Modular Angle Encoders with Magnetic Scanning and Mechanical Fault Exclusion

Form No Assembly & Operating Instructions for: SAFETY PRECAUTIONS

printed pages will not be updated

Chapter 20. Standard Practices - Airframe

HMP-200 BENDER INSTRUCTION SET

Maintenance Information

Table of contents. 2 Safety E517EN_03.DOC. 1. Safety Description Correct use Technical data F Lock seams...

BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE

CoroChuck 970 SynchroFlex Benefits

TYPE 3740/3740D WET/DRY RUNNING CARTRIDGE SPLIT SEAL

The Ensat self-tapping threaded insert...

Magnetic Inductive Flow Sensor

CENTAFLEX-A Assembly and operating instructions 008A N/S.. M EN Rev. 2

G01 through G10 Series Hydraulic Actuators Double-Acting with M11 Hydraulic Override Disassembly and Reassembly

Motor spindle Operating Instructions. Ref

linear/swivel clamp CLR Operating instructions e [ ]

FMG70B Series Magnetic Inductive Flow Sensor

PF 3000 Face Milling Cutter

Fasteners. Bolts. NAPA FastTrack Counter Sales Training Fasteners Page 1. Figure 1. Typical Measurements for a Bolt or Hex Head Cap Screw

Bolt Tensioning. This document is a summary of...

I-W07/W77. Couplings DETAIL A WARNING. Photo Showing Pipe with Weld Seam Ground 6 inches/152 mm Back from Pipe End and an AGS Groove

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

Chiltern Model Steam Engines

T Pac2 standard for prevailing torque threadlocker Dri-Loc Plastic. Introduction. Contents. 1 Scope and field of application

Threadlocking Adhesives

MTS-ACB. RENOGY Photovoltaic Module Adjustable Curved Bracket E Philadelphia St, Ontario, CA Version: 1.

MB-105 BENDER INSTRUCTION SET PRO-TOOLS 7616 INDUSTRIAL LANE TAMPA, FLORIDA PHONE FAX

Installation and operating instructions for Brake disc with clamping element RLK 608 E Schaberweg Telefon

Installation and Operational Instructions for ROBA -DS couplings. _ (disk pack HF) Sizes

The Lecture Gyroscope

12 TON HYDRAULIC SHOP PRESS. Instruction Manual. Please read this instruction manual carefully before use.

Operating instruction for the quick-change tap holders type:

Operating instruction for the quick-change adapters type:

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

flexible couplings for pipe connections with axial restraint

Notes. Modifications and constructional corrections arising particularly from technological development excepted.

Translation of the original operating instructions Version: 11/2017

UNIT 9b: SCREW FASTENERS Introduction Functions Screw Features Elements Terms of a Thread Profile

SCREW DRIVES. trapezoidal, S, ACME. KULIČKOVÉ ŠROUBY KUŘIM, a.s. We always have a solution!

Transcription:

Assembly instructions

Important notes on VOSS assembly instructions In order to ensure maximum performance and functional reliability of VOSS products, the respective assembly instructions, operating conditions and tube recommendations have to be adhered to. We recommend that you use VOSS pre-assembly devices at all times. It is absolutely essential to follow the operating instructions for the respective pre-assembly device used. Do not start with assembly until you are absolutely sure that you have understood the operating and assembly instructions for each VOSS pre-assembly device or machine, tool and product. Incorrect handling leads to risks regarding safety and leak-tightness and can result in failure of the entire connection. It is impossible for the manufacturer to monitor whether the user is adhering to the operating and assembly instructions for individual pre-assembly devices or machines, tools and products, as well as what conditions prevail and what methods are used for installation, operation, application and maintenance of the individual products. Improper workmanship can lead to material damage, which in turn may pose a danger to life and limb. This means that VOSS Fluid GmbH can accept no responsibility or liability for loss, damage or costs incurred due to faulty installation, improper operation or incorrect application and maintenance or from any related issue. Failure to heed this warning will lead to loss of guarantee. VOSS Fluid GmbH reserves the right to make changes or additions to the information provided without prior notification. Customers can obtain the latest version of the operating and assembly instructions upon request, or from our download area at: www.voss.net

General notes on VOSS assembly instructions Make sure that all components, including the tubes, are clean before assembly is started and that they remain clean during the entire assembly process. Soiled components may lead to failure of the system. Before starting assembly, make sure that you have carried out all preparatory work in accordance with the respective instructions. Specifications concerning permissible steel tubes: seamless, cold-drawn and normalized precision steel tubes as specified in DIN EN 10305-4, material E235+N, mat. no. 1.0308+N or E355, mat. no. 1.0580. The tubes must be ordered by specifying the outer diameter and the inner diameter. Specifications concerning permissible stainless steel tubes: seamless, cold-drawn and solution-annealed, scale-free stainless steel tubes in CFA or CFD delivery condition of dimensions and tolerances according to DIN EN 10305-1 and all other delivery conditions as specified in DIN EN 10216-5, material X6CrNiMoTi17-12-2, mat. no. 1.4571. The tubes must be ordered by specifying the outer diameter and the inner diameter. The tubes should be prepared with the same thoroughness as preassembly and final assembly of the connection. Especially when using long tubes, check the end sections for damage or distortion. We recommend that pre-assembled tubes which are not to be finally assembled yet should be fitted with protective caps. Marking a stroke on the union nut and the tube makes it easier to achieve the correct number of turns when tightening the coupling. Before starting to assemble VOSS components with elastomer seals, always check that: the nut and the seal surfaces are clean and undamaged and/or the elastomer sealing is clean and undamaged Determining the tightening torque for screw couplings The tightening torques specified in the catalogue apply under the following conditions: steel fittings with VOSS coat surface coating the specified nominal pressure ranges assume that the mating material has a tensile strength of 600 N/mm² our recommendations on lubrication of the threaded studs are observed If other values for strength, modulus of elasticity and friction-surface combinations are used, the user has to adapt the tightening torque empirically. The recommended tightening torques have to be adhered to if the pressure range is to be fully utilized and the appropriate safety level is to be maintained. The recommended tightening torques for the threads are given in the tables for the respective type of thread. Explanation of symbols and other notes Visual inspection Turn until hand-tight or carry out another manual activity Use the tool to tighten the coupling according to the instructions Oil and lubricate at the point marked with an arrow All dimensions in millimetres [mm]

Assembly instructions for adjustable elbow couplings with lock nut 1 Notes Before starting the assembly work, read and observe the general notes in the up-to-date VOSS catalogue and check that your assembly instructions are up to date. These assembly instructions apply to adjustable couplings with lock nuts to be screwed into threaded holes as specified in: ISO 9974-1 metric fine thread, cylindrical ISO 1179-1 Whitworth pipe thread, cylindrical Union nut Attention! Before installing the coupling, check the thread and the soft seal. PEFLEX moulded seal 2 Assembly procedure Lubricate the O-ring and threads lightly (e.g. using mineral-oil based hydraulic fluid HLP32). Screw the coupling into the threaded hole manually until the lock nut (with the PEFLEX moulded seal) is in contact with the mating surface. Turn the coupling (by not more than one turn in the opposite direction) until it points in the desired direction. Hold the stud with a spanner and tighten up the lock nut, taking care not to exceed the specified torque.

Elbow couplings 3 Tightening torques Series Thread Tightening torque Nm -10 % L G 1/8 20 L G 1/4 50 L G 3/8 80 L G 1/2 105 L G 3/4 190 L G 1 250 L G 1 1/4 400 L G 1 1/2 500 Series Thread Tightening torque Nm -10 % S G 1/4 50 S G 3/8 80 S G 1/2 110 S G 3/4 220 S G 1 280 S G 1 1/4 400 S G 1 1/2 500