MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Similar documents
Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

MY-GS CSM_MY-GS_DS_E_2_1

CSM_G7S-_-E_DS_E_7_1

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

E3X-DRT21/SRT21/CIF11

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Alternate Operation Relay 61F-AN/-APN2

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Model Number Structure

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

E6F-CWZ5C (1000P/R) 2M

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

OMRON MK-I / -S RELAY

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

Model Number Structure

Fluoro plastic housing for highest chemical and detergent resistance

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Model Number Structure

Model Number Structure

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Phase-sequence Phase-loss Relay

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

General-purpose Relay

Switch Mode Power Supply

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Relays with Forcibly Guided Contacts G7SA

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

E8EB-N0C2B E8EB-N0B2B

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Classification Enclosure rating Contact form Contact material

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

General-purpose Relay

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Switch Mode Power Supply

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

E6B2-C. General-purpose Encoder with External Diameter of 40 mm. Incremental 40-mm-dia. Rotary Encoder. Ordering Information

SPST-NO SPDT DPST-NO DPDT

For Momentary Operation

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Phase-sequence Phase-loss Relay

Model Number Structure

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

Ordering Information. Ratchet Relay G4Q. Model Number Legend

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

General-purpose Relay

Details on the New G2RS

Safety Monitoring Relays

Model Number Structure

SPST-NO SPDT DPST-NO DPDT

Single-phase Voltage Relay

Single-phase Current Relay

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

20 Series Power Relays

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Model Number Structure

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Sensing method Sensing distance Model

Model Number Structure

G2RL-1A G2RL-1 G2RL-2A G2RL-2

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

3. Contact Form A: SPST-NO

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Single-phase Current Relay

Transcription:

Compact Power Relays MK CSM_MK_DS_E A Wide Variation of Octal Pin Power Relays Encased Relays unified to an AC rating (/ VAC at /Hz and / VAC at / Hz). Easy to install, wire, and use. Highly durable with a life of over,, mechanical operations. Extensive product lineup: Standard models, encased models, special contact models, bifurcated contact models, double-winding latching models, and more. Refer to the Common Relay Precautions. Refer to the standards certifications and compliance section of your OMRON website for the latest information on certified models. Model Number Structure Configuration (Models certified for safety standards are included. Refer to page ) Classification Standard models Bifurcated contacts Models with built-in mechanical operation indicators Models with built-in operation indicator lights Special internal connection models Models with built-in arc barriers Models with built-in diodes Models certified for safety standards Structure Number of poles MKP MKP MKZP MKZP MKPA MKPA MKPN MKPN Encased models Relays with Plug-in Terminals MKP- and MKZP- MKP-, MKZP-, MKP-, and MKZP- MKLP MKP-DO MKP-DO MKP-US and MKP-US MKP-US, MKP-US, and MKP-US Note:. Refer to the MKK Electromagnetic Latching Relays.. If an AC rated voltage is specified for models with built-in diodes, the diode will act as a varistor.

Ordering Information List of Models Encased Models and Models with Plug-in Terminals Number of poles poles poles Classification Model Rated voltage (V) Model Rated voltage (V) Standard models MKP,,,, /, or / VAC,,,, /, or / VAC MKP,,, 8, or VDC,,, 8, or / VDC Bifurcated contacts MKZP, /, or / VAC,,,, /, or / VAC MKZP,, 8, or VDC,,, 8, or VDC Models with built-in diodes MKP-DO,,, 8, or VDC MKP-DO,, 8, or VDC Models with built-in operation indicators, 8, or VDC, 8, or VDC / or / VAC, /, or / VAC MKPA MKPA Models with built-in operation indicators,,, 8, or VDC,, 8, or VDC,,,, /, or / VAC,,,, /, or / VAC MKPN MKPN Models with built-in arc barriers, 8, or VDC,, /, or / VAC --- --- MKLP,,, /, or / VAC,,, /, or / VAC MKP- MKP- Single-contacts,,, 8, or VDC,, 8, or VDC,, /, or / VAC Special internal connec- --- --- MKP-,,, 8, or VDC, /, or / VAC, / or / VAC tion models MKZP- MKZP- Bifurcated or VDC,,, 8, or VDC contacts, /, or / VAC --- --- MKZP- VDC Models certified for safety standards Encased Models and Models with Plug-in Terminals Number of poles poles poles Classification Model Rated voltage (V) Model Rated voltage (V) Standard models or VAC MKP-US (Ag contacts) VDC MKP-US VAC /() VAC MKP-US Special internal connection VDC MKP-US VDC models (Ag contacts) or /() VAC MKP-US VDC Ratings and Specifications Ratings (Refer to page for models certified for safety standards.) Operating Coil MK(P or P-), MK(P, P-, or P-), MKZP(-), MK@PA, and MK@P-DO Item Rated current (ma) Coil inductance (H) Must-operate voltage lease voltsumption Must-re- Power con- Coil resistance (Ω) Armature ON voltage (V) Maximum Armature Rated voltage (V) Hz Hz OFF (V) age (V) (VA, W)..8. Approx..9 to 8... Approx.. (at 98 88 9..78 AC % min. Hz). 9.9. */./.7 9/, 9.. Approx..9 to */.7/.9 / 7,.9 9. 8% max. %. (at Hz)... 9..87 DC.8. % min. Approx.. 8 9.,.99..7,8..

MKZP(- and -) and MKLP Item MK@PN Note:. The rated current and coil resistance are measured at a coil temperature of C with tolerances of +%/ % for the AC rated current and ±% for the DC coil resistance.. The AC coil resistance and coil inductance values are reference values only.. Operating characteristics were measured at a coil temperature of C.. The maximum allowable voltage is the maximum value of the allowable voltage fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of C. There is no continuous allowance. * These are for a rating specification. Contact Ratings Rated current (ma) Rated voltage (V) Hz Hz AC DC Coil resistance (Ω).8 8. 8 Power consumption (VA, W) Approx..8 (at Hz) */ 7./9.8./., Approx.. to */./.9./.7,9.8 (at Hz) 9.9 77 79 Approx..9 8 9, 8.9, Model MKP(-), MKPN, MKPA, and MKP-DO Item Rated current (ma) Rated voltage (V) Hz Hz AC DC MKP(- and -), MKPN, MKPA, and MKP-DO Coil resistance (Ω) 7. 9. 9 Power consumption (VA, W) Approx.. to.7 (at Hz) */./.7 9/, Approx..9 to */.7/.9 / 7,. (at Hz) 7. 9 Approx.. to 7. (at Hz) 8 8,.7,8 Approx.. MKZP(-) and MKZP(- and -) Load Inductive load Inductive load Inductive load Inductive load Item Resistive load cos φ =., Resistive load cos φ =., Resistive load cos φ =., Resistive load cos φ =., L/R = 7 ms L/R = 7 ms L/R = 7 ms L/R = 7 ms Contact structure Single Bifurcated Single Contact materials Ag AgNi Ag Rated load A at VAC A at VDC A at VAC.A at VDC A at VAC A at VDC. A at VAC. A at VDC A at VAC A at VDC. A at VAC. A at VDC A at VAC A at VDC Rated carry current A A A A Maximum contact voltage Maximum contact current Maximum switching capacity (reference value) VAC VDC VAC VDC VAC VDC MKLP VAC VDC A at VAC.8 A at VDC A A A A A A A A, VA 7 W VA W VA 8 W VA W VA 8 W VA W, VA 7 W VA W Ambient operating temperature Ambient operating humidity Characteristics to C (with no icing or condensation) % to 8% Item Classification Bifurcated contacts Encased models Contact resistance * mω max. mω max. Operation time * AC: ms max., DC: ms max. Release time * ms max., ( * ms max.) Maximum operating Mechanical 8, operations/h frequency Rated load,8 operations/h Insulation resistance * MΩ min. Between coil and contacts, VAC at / Hz for min. poles Between contacts of different polarity Dielectric Between contacts of the same polarity VAC at / Hz for min. strength Between coil and contacts, VAC at / Hz for min. poles Between contacts of different polarity Between contacts of the same polarity VAC at / Hz for min. Vibration resistance Destruction Malfunction to to Hz,.7-mm single amplitude (.-mm double amplitude) to to Hz,.-mm single amplitude (-mm double amplitude) Models certified for safety standards UL and CSA-certified models are also available. The ratings for these models are not the same as our standard models for Japan. UL-certified Models (File No. E) CSA-certified Models (File No. LR) Model MK Shock resistance Malfunction m/s Destruction m/s,, operations min. (operating Mechanical frequency: 8, operations/hr) Endurance Electrical *, operations min. (rated load, switching frequency:,8 operations/h) Failure rate P level (reference value * ) μa at VDC ma at VDC Weight Approx. 8 g Note: The above values are initial values. *. Measurement conditions: A at VDC using the voltage drop method *. Measurement conditions: With rated operating power applied, not including contact bounce. Ambient temperature condition: C *. Measurement conditions: For VDC applied to the same location as for dielectric strength measurement. *. This value is for models with built-in diodes. *. Ambient temperature condition: C *. This value was measured at a switching frequency of operations per minute. Number of poles Coil ratings to VAC to VDC Contacts Ag Contact ratings A VAC Resistive A 8 VDC Resistive Number of test operations, operations

MK Engineering Data Standard Models, MK@(P) AC resistive load AC resistive load DC resistive load DC resistive load AC inductive load (cos ϕ =.) Ambient Temperature vs. Must-operate and Must-release Voltage MKP AC ( Hz) Must-operate/must-release voltage (%) MKP Maximum Switching Capacity MKP Maximum Switching Capacity VAC inductive load (cos φ =.) DC inductive load.. Number of Relays: 8 DC inductive load.. Endurance Curve Number of operations ( operations) VAC resistive load VDC resistive load VDC inductive load VAC inductive load (cos φ =.) VAC resistive load VDC resistive load VDC inductive load VAC inductive load (cos φ =.) Number of Relays: 8 MKP DC Ambient temperature ( C) Endurance Curve Contact voltage (V) Contact voltage (V) Must-operate/must-release voltage (%) Number of operations ( operations) Must-operate voltage Must-release voltage Must-operate voltage Must-release voltage 8 7 8 9 8 Ambient temperature ( C) Ambient Temperature vs. Coil Temperature Rise MKP ACV ( Hz) AC resistive load DC resistive load AC inductive load (cos φ =.). DC inductive load AC resistive load AC inductive load (cos φ =.) DC resistive load. Coil temperature rise ( C) MKLP Maximum Switching Capacity MKZP and MKZP Maximum Switching Capacity 8 Number of Relays: Contact carry current. A. A A DC inductive load.... Contact voltage (V) Endurance Curve VAC resistive load VDC resistive load VDC inductive load VAC inductive load (cos φ =.) VAC resistive load VDC resistive load VAC inductive load (cos φ =.) 8 Ambient temperature ( C) 8 Contact carry current. A. A A Number of Relays: VDC inductive load MKP DC Contact voltage (V) Number of operations ( operations) Number of operations ( operations) Endurance Curve Coil temperature rise ( C) 7 8 9 8 Ambient temperature ( C)

Malfunctioning Shock MKP AC Unit: m/s X Y Z N = Measurement: Shock was applied times each in directions along axes with the Relay energized and not energized to check the shock values that cause the Relay to malfunction. Criteria: m/s Z X NC contacts NO contacts Y Shock direction Contact Reliability (JIS C Allen Bradley Circuit) Encased Models, MKP and MKP VAC Encased Models, MKP and MKP VDC Cumulative number of stops λ =. per operation Cumulative number of stops λ =. per operation 8 8 stops stops Number of operations ( operations) Number of operations ( operations) Contact Reliability (Modified Allen Bradley Circuit) MKP VDC MKP / VAC,, N = average value Load: ma at VDC,, NO contacts NC contacts N = average value No-load contacts N = Failure rate: λ =. per operation Open contacts Self-latching contacts Closed contacts Current-carrying contact Open contacts Number of operations ( operations) Number of operations ( operations) Contact Reliability (Modified Allen Bradley Circuit) MKZP and MKZP Non-open contacts, Number of operations ( operations),, N = average value Load: ma at VDC,, N = average value No-load contacts NO contacts Self-latching contacts Closed contacts Open contacts Current-carrying contact Number of operations ( operations) NC contacts Number of operations ( operations)

Dimensions List of Models Encased models (Unit: mm) Relays with Plug-in Terminals MK(Z)P(-) MKP-DO MKPN MKPA Terminal Arrangement/Internal Connections (Bottom View) MKP, MKZP, and MKP- and MKZP- MKPA. max. MKPN *,, or VAC,, or VDC MKPN * VAC 8 VDC MKPN * / or / VAC VDC. max.. max. The above figure is for the MKP. MKP-DO Note: Only the MKP-DO has coil polarity. *. The operation indicators are pilot indicators. *. The operation indicators are neon indicators. MK(Z)P(-, -) MKPA MKLP MKP-DO MKPN MK(Z)P and MKPA MKLP MKP- MKZP- MKP- MKZP-. max. MKPN *,, or VAC,, or VDC MKPN * VAC 8 VDC MKPN * / or / VAC VDC. max.. max. The above figure is for the MKZP. MKP-DO Note: Only the MKP-DO has coil polarity. *. The operation indicators are pilot indicators. *. The operation indicators are neon indicators.

Connection Sockets Refer to Common Socket and DIN Track Products for external dimensions and pricing information. Sockets Front-mounting Sockets Back-mounting Sockets Relay Track or screw mounting Solder terminals Wrapping terminals Relays with PCB Terminals poles PF8A PF8A-E PL8 PL8-Q PLE8- PFA PFA-E PL PL-Q PLE- poles Mounting Height with Sockets Front-mounting Sockets Back-mounting Sockets *77 poles *9 7. poles 87 8. 7. or poles PF8A PFA Note: The PF8A and PFA can be mounted on a track or with screws. * When a PFC-A is used. PL@ Relay Hold-down Clips Refer to Common Socket and DIN Track Products for external dimensions and pricing information. Secure the Relay with the Hold-down Clips to prevent the Relay from falling out due to vibration or shock. PFC-A PLC Type Sockets Front-mounting Sockets Back-mounting Sockets Track or screw mounting Track or screw mounting Solder terminals and wrapping terminals Applicable Relay MK(Z)P MKP MKKP MKZP MKLP PF8A PFC-A --- --- PFA --- PFC-A PFC-A PL8(-Q) PLC --- --- PL(-Q) --- PLC PLC- PLE8- PLC- --- --- Relays with PCB Terminals PLE- --- PLC- --- Safety Precautions Refer to the Common Relay Precautions for precautions that apply to all Relays. Precautions for Correct Use Installation Orientation There is no specified installation orientation. About the Built-in Diodes* The diodes that are built into the Relays are designed to absorb reverse voltage from the Relay s coil. If a large surge in voltage is applied to the diode from an external source, the element will be destroyed. If there is the possibility of large voltage surges that could be applied to the elements from an external source, take any necessary surge absorption measures. * The MK Series does not have any models with a built-in CR circuit. 7

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation All Right Reserved.