Gain and Breakdown Voltage Measurements

Similar documents
Tutors Dominik Dannheim, Thibault Frisson (CERN, Geneva, Switzerland)

Silicon Photo Multiplier SiPM. Lecture 13

Characterisation of SiPM Index :

Characterization of a prototype matrix of Silicon PhotoMultipliers (SiPM s)

CALICE AHCAL overview

FACTOR: first results on SiPM characterization

arxiv: v1 [physics.ins-det] 29 Feb 2016

A new single channel readout for a hadronic calorimeter for ILC

The CMS Outer HCAL SiPM Upgrade.

J-Series High PDE and Timing Resolution, TSV Package

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

IRST SiPM characterizations and Application Studies

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

Recent Development and Study of Silicon Solid State Photomultiplier (MRS Avalanche Photodetector)

arxiv: v2 [physics.ins-det] 17 Oct 2015

arxiv: v3 [astro-ph.im] 17 Jan 2017

Status of the LED calibration system

Calibration of Scintillator Tiles with SiPM Readout

KLauS4: A Multi-Channel SiPM Charge Readout ASIC in 0.18 µm UMC CMOS Technology

Contents. The AMADEUS experiment at the DAFNE collider. The AMADEUS trigger. SiPM characterization and lab tests

Test and Simulation of Plastic Scintillator Strips readout by Silicon Photomultipliers

SiPM Module PRELIMINARY

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

High granularity scintillating fiber trackers based on Silicon Photomultiplier

PRELIMINARY RESULTS OF PLASTIC SCINTILLATORS DETECTOR READOUT WITH SILICON PHOTOMULTIPLIERS FOR COSMIC RAYS STUDIES *

A tracking detector to study O(1 GeV) ν μ CC interactions

Silicon Carbide Solid-State Photomultiplier for UV Light Detection

CHAPTER 11 HPD (Hybrid Photo-Detector)

arxiv: v1 [physics.ins-det] 5 Sep 2011

Application of avalanche photodiodes as a readout for scintillator tile-fiber systems

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Milestone Report

Characterizing a single photon detector

The PERDaix Detector. Thomas Kirn I. Physikalisches Institut B. July 5 th 2011, 6 th International Conference on New Developments In Photodetection

Timing Measurement in the CALICE Analogue Hadronic Calorimeter.

arxiv: v2 [physics.ins-det] 14 Jan 2009

Results on the LED Pulser System for the Hall A DVCS Experiment

Development of LYSO detector modules for a charge-particle EDM polarimeter

Studies of Scintillator Tile Geometries for direct SiPM Readout of Imaging Calorimeters

Andrea WILMS GSI, Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany

Introduction to silicon photomultipliers (SiPMs) White paper

AFBR-S4N44P163-DS102. Data Sheet. 4 4 NUV-HD Silicon Photo Multiplier Array. Description. Features. Applications

RAPSODI RAdiation Protection with Silicon Optoelectronic Devices and Instruments

PoS(PhotoDet 2012)058

Review of Solidstate Photomultiplier. Developments by CPTA & Photonique SA

Properties of a Detector

InGaAs SPAD freerunning

Concept and status of the LED calibration system

Nuclear Instruments and Methods in Physics Research A

MAROC: Multi-Anode ReadOut Chip for MaPMTs

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration

R & D for Aerogel RICH

FBK SiPM test with a charge integration FE

Scintillator/WLS Fiber Readout with Geiger-mode APD Arrays

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

AFBR-S4N44C013-DS100. Data Sheet. NUV-HD Silicon Photo Multiplier. Features. Description. Applications

Characteristics of a prototype matrix of Silicon PhotoMultipliers (SiPM)

Total Absorption Dual Readout Calorimetry R&D

SiPMs for solar neutrino detector? J. Kaspar, 6/10/14

ILC Prototype Muon Scintillation Counter Tests

The Calice Analog Scintillator-Tile Hadronic Calorimeter Prototype

arxiv: v2 [physics.ins-det] 10 Jan 2014

Red, Green, Blue (RGB) SiPMs

CAEN. Electronic Instrumentation. CAEN Silicon Photomultiplier Kit

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

Understanding the Properties of Gallium Implanted LGAD Timing Detectors

Near Ultraviolet (NUV) SiPMs

AN ADVANCED STUDY OF SILICON PHOTOMULTIPLIER

Low Dark Count UV-SiPM: Development and Performance Measurements P. Bérard, M. Couture, P. Deschamps, F. Laforce H. Dautet and A.

Octal ASD Certification Tests at Michigan

Time Resolution Studies with Timepix3 Assemblies with Thin Silicon Pixel Sensors

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

Study of Resistive Plate Chambers Scintillation detectors and Reconstruction of muon tracks in RPCs

SensL B-Series Silicon Photomultipliers for TOF- PET. NDIP2014 Kevin O Neill 4 th July, 2014

Arrays of digital Silicon Photomultipliers Intrinsic performance and Application to Scintillator Readout

A Survey of Power Supply Techniques for Silicon Photo-Multiplier Biasing

CATIROC a multichannel front-end ASIC to read out the SPMT system of the JUNO experiment

Reminder on the TOB electronics architecture Test of the first SS rod prototype

arxiv: v5 [physics.ins-det] 28 Dec 2017

TPC Readout with GEMs & Pixels

Time of Flight Measurement System using Time to Digital Converter (TDC7200)

Application Notes: Discrete Amplification Photon Detector 5x5 Array Including Pre- Amplifiers Board

MAROC: Multi-Anode ReadOut Chip for MaPMTs

Type Features Applications. Enhanced sensitivity in the UV to visible region

InGaAs SPAD BIOMEDICAL APPLICATION INDUSTRIAL APPLICATION ASTRONOMY APPLICATION QUANTUM APPLICATION

Geiger-mode APDs (2)

Characterization Test of SensL MicroFJ Device: SMTPA S/N. 1 Lot #150925

Photon Count. for Brainies.

Production of HPDs for the LHCb RICH Detectors

event physics experiments

Characterization of Silicon Photomultipliers and their Application to Positron Emission Tomography. Zhiwei Yang. Abstract

Silicon Photomultiplier

Experiment 10. The Speed of Light c Introduction Apparatus

Fast Timing for Collider Detectors

arxiv: v1 [astro-ph.im] 19 Nov 2014

Testing the Electronics for the MicroBooNE Light Collection System

The optimal cosmic ray detector for High-Schools. By Floris Keizer

SiPMs as detectors of Cherenkov photons

P ILC A. Calcaterra (Resp.), L. Daniello (Tecn.), R. de Sangro, G. Finocchiaro, P. Patteri, M. Piccolo, M. Rama

March 31, 2003 Single-photon Detection at 1.55 µm with InGaAs APDs and via Frequency Upconversion Marius A. Albota and Franco N.C.

Polarimetry Concept Based on Heavy Crystal Hadron Calorimeter

Transcription:

Gain and Breakdown Voltage Measurements CLICdp: ECAL Lab Meeting (CERN) Magdalena Munker March 2, 215

Setup for study of Scintillator tiles with SiPM Readout Setup in cooled dark room ( temperature about 2 C): elektron source (strontium 9) elektron gun B ca..2 T Electron source strontium 9 Sr: Sr Y (e 2 + νe) + e 1 + νe Selectable electron energy Opening: ( X, Y) = (1.2 mm, 1.2 mm) opening of electron gun scintillator tile SiPM Scintillators covered by reflecting foil: Trigger fibres: 1 mm x 1 mm x 2 mm Scintillator tile: 15 mm x 15 mm x 1 mm scintillating fibre = movable direction SiPM scintillating fibre SiPM SiPMs from Hamamatsu: area of 1 mm, 4 pixel (5 µm) direct coupling to the scintillator This talk: About characterization of the SiPM which is used to readout signal in scintillator tile ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 2

Setup for Characterization of SiPM ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. Same setup, but: Replace scintillator tile by optical fibre, connected to LED pulser Do not use trigger and electron gun Simplified schematic of the setup for the characterization of the SiPM: V(bias) LED pulser optical fibre SiPM pulse generator trigger signal PCB SiPM readout data readout

Observable to Measure Signal in SiPM Amplitude [ mv ] Observable to measure signal in SiPM = charge in SiPM: Q = pulses dt F amplification R picoscope (R picoscope = 5 Ω, F amplification = 9) Pedestal correction: Temperature correction: Q(MPV) [pc] 7.5 8 dq / dt = ( -.562 ±.1 ) pc / C 7 Pedestal Time [.8 ns ] Signal 6.5 18 19 2 21 22 Temperature [ C] Pedestal and temperature correction of the charge: ) Q corrected = (Q signal Nsignal 1 Qpedestal Npedestal 1 + α r (T T) α r = dq dt 1 Q(T ) ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 4

Measured Charge Spectrum ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 5 Gain = ( 978 ± 8 ) x 1 Temperature [ C] = 19; V(bias) [ V ] = 71.5 # Trigger 6 4 2.5 1 1.5 Q [pc] ( Pedestal & temperature corrections applied ) Peaks from different number of photoelectrons clearly visibly Underlying noise spectrum from afterpulses?

Gain Calculation Check linear dependence of Q(MPV) Q(µ) for different photoelectron peaks to validate calibration of charge to number of photoelectrons ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 6 # Trigger 5 4 2 Temperature [ C ] = 19; V(bias) [ V ] = 71.5 Gain = ( 99 ± 2 ) x 1 Gain calculation: g i,j = Q i Q j /e {i, j} = peaks in charge distribution with i j = 1 e = elementary charge 1.5 1 1.5 2 Q [pc] weighted mean: Gain = i,j w i,j g i,j W First peak corresponds to pedestal Fit Gauss function to pedestal peak Q(µ) Other peaks correspond to signal of 1 photoelectron Fit Landau Gauss functions to each other peak Q(MPV) weights of uncertainties: w i,j = 1 σ 2 g i,j, W = i,j w i,j

Cross Check of the Gain Calculation ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 7 Identify peaks in charge spectrum with different numbers of photoelectrons # p.e. Calculate for each # p.e. difference in charge to pedestal peak Q Q [ pc ].6 V(bias) = 71.5 V.4.2 1 2 4 # p.e. Can calibrate measured charge to # p.e. with the measured gain: # p.e. = Q/(Gain e) (e = electron charge)

Uncertainties of the Gain Calculation ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 8 Motivation: Breakdown voltage calculation by linear fit of gain values for different bias voltages Composition of uncertainties in gain measurement: 1.) Propagate uncertainties of Q(MPV) and Q(µ) ( in the order of 1 % ) 2.) Uncertainties from the temperature correction: Temperature [ C ] = 19; V(bias) [ V ] = 71.5 6 Gain = ( 989 ± 2 ) x 1 4 2 Temperature correction (+) 5 4 2 1 Temperature [ C ] = 19; V(bias) [ V ] = 71.5 Gain = ( 14 ± 2 ) x 1 Temperature correction (-).5 1 1.5 2.5 1 1.5 2 Additional uncertainty of.75 % from the temperature correction

Breakdown Voltage Calculation ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 9 Motivation: Currently used bias voltage of V(bias) = 71.5 V is optimal value for T = 25 C Temperature in the dark room is in the range of T = (18 22) C Calculate breakdown voltage to check if V(bias) = 71.5 V is optimal Measurement of breakdown voltage corrected to T = 19 C: Repeat gain calculation for different bias voltages Gain ( V(bias) V(bd) ) ( V bd = breakdown voltage ) Linear fit of Gain vs. bias voltage Gain / 1 15 V(bd) = ( 7. ±.2 ) V 1 5 Χ2 / ndof = 1.6 Determine V bd from intersect of linear fit function with x-axis 7 7.5 71 71.5 72 V(bias) [ V ]

Temperature Dependence of the Breakdown Voltage Expectations: Higher temperature leads to higher thermal vibrations of silicon lattice Smaller path length of the electron Higher breakdown voltage Correct measurement of breakdown voltage for different temperatures: Gain / 1 15 1 V(bd) = ( 7. ±.2 ) V Χ2 / ndof = 2 Gain / 1 14 12 1 8 6 V(bd) = ( 7.1 ±.2 ) V Χ2 / ndof = 1. 5 Corrected to T = 18.6 C 7 7.5 71 71.5 72 V(bias) [ V ] 4 2 Corrected to T = 21. C 7 7.5 71 71.5 72 V(bias) [ V ] Value of breakdown voltage is stable in considered temperature range of the measurements Is V(bias) = 71.5 V the optimal value of the bias voltage? ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 1

Breakdown Voltage / Interpretation of Results ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 11 Is V(bias) = 71.5 V the optimal value of the bias voltage? : Bias voltage should be safely above breakdown voltage But the signal to noise ratio might get worse with higher bias voltage Measure signal in scintillator tile for different bias voltages: Use the initial setup ( see page 2 ) Measure charge in center of the scintillator tile for different bias voltages of the SiPM at the scintillator tile / Q(MPV) σ Q(MPV).8.6.4.2 7 7.5 71 71.5 72 V Bias [ V ] Used bias voltage of V(bias) = 71.5 V seems to be in a good range

Summary and Outlook ECAL Lab Meeting M. Munker Gain and Breakdown Voltage Measurement for the used SiPM p. 12 Measurement of gain: Conversion of charge into number of photoelectrons Comparison to other studies Measurement of breakdown voltage: Confirmation that used bias voltage is in a good range To do: Characterisation of new SiPMs Application of new SiPMs for uniformity studies