Application Guide & Release Notes

Similar documents
IR/SR TrueFISP. Works-in-Progress package Version 1.2. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B.

WU-Minn HCP 1200 Subjects Release: Reference Manual

SIEMENS MAGNETOM Skyra syngo MR D13

Pulse Sequence Design and Image Procedures

Background (~EE369B)

Works-in-Progress package Version 1.0. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B. January 22, 2003

TimTX TrueShape. The parallel transmit architecture of the future. Answers for life.

Applications Guide. Spectral Editing with SVS. (Works-in-Progress) MAGNETOM TaTs and Verio Systems (3T)

Diff Ganzkörper ep2d_diff_stir_b50_800_tra

Noninvasive Blood Flow Mapping with Arterial Spin Labeling (ASL) Paul Kyu Han and Sung-Hong Park

3T Unlimited. ipat on MAGNETOM Allegra The Importance of ipat at 3T. medical

Advanced MSK MRI Protocols at 3.0T. Garry E. Gold, M.D. Associate Professor Department of Radiology Stanford University

Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

Pulse Sequence Design Made Easier

Pulse Sequences: Rapid Gradient Echo

MRI Metal Artifact Reduction

Diffusion and Functional MRI of the Spinal Cord Methods and Clinical Applications

ISSN X CODEN (USA): PCHHAX. The role of dual spin echo in increasing resolution in diffusion weighted imaging of brain

Simultaneous Multi-Slice (Slice Accelerated) Diffusion EPI

Hadamard Slice Encoding for Reduced-FOV Diffusion- Weighted Imaging

H 2 O and fat imaging

Encoding of inductively measured k-space trajectories in MR raw data

Liver imaging beyond expectations with Ingenia

Module 2. Artefacts and Imaging Optimisation for single shot methods. Content: Introduction. Phase error. Phase bandwidth. Chemical shift review

High Field MRI: Technology, Applications, Safety, and Limitations

(N)MR Imaging. Lab Course Script. FMP PhD Autumn School. Location: C81, MRI Lab B0.03 (basement) Instructor: Leif Schröder. Date: November 3rd, 2010

Page 1 of 9. Protocol: adult_other_adni3_study_human_ge_3t_25w_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

RAD 229: MRI Signals and Sequences

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2010 July 21.

The SENSE Ghost: Field-of-View Restrictions for SENSE Imaging

MRI Summer Course Lab 2: Gradient Echo T1 & T2* Curves

System/Imaging Imperfections

Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging

Annual Ceiling Amount: $

Gradient Spoiling. Average balanced SSFP magnetization Reduce sensitivity to off-resonance. FFE, FISP, GRASS, GRE, FAST, Field Echo

MR Basics: Module 8 Image Quality

Half-Pulse Excitation Pulse Design and the Artifact Evaluation

2014 M.S. Cohen all rights reserved

MR in RTP. MR Data for Treatment Planning: Spatial Accuracy Issues, Protocol Optimization, and Applications (Preview of TG117 Report) Acknowledgements

Research Article Implementation and Application of PSF-Based EPI Distortion Correction to High Field Animal Imaging

Downloaded from by on 02/07/18 from IP address Copyright ARRS. For personal use only; all rights reserved

Experience in implementing continuous arterial spin labeling on a commercial MR scanner

MR Basics: Module 6 Pulse Sequences

NIH Public Access Author Manuscript Int J Cardiovasc Imaging. Author manuscript; available in PMC 2008 May 26.

1 Introduction. 2 The basic principles of NMR

10. Phase Cycling and Pulsed Field Gradients Introduction to Phase Cycling - Quadrature images

Image Quality/Artifacts Frequency (MHz)

The Usefulness of Simultaneously Excited Magnetic Resonance Signals from Diffusion Tensor Image

Improving high-field MRI using parallel excitation

BOLD fmri: signal source, data acquisition, and interpretation

Principles of MRI EE225E / BIO265. Lecture 21. Instructor: Miki Lustig UC Berkeley, EECS. M. Lustig, EECS UC Berkeley

The promise of high-field MRI. High Field MRI Technology, Applications, Safety, and Limitations. High-field Scanners

MR in Tx Planning. Acknowledgements. Outline. Overview MR in RTP

Hardware. MRI System. MRI system Multicoil Microstrip. Part1

Magnetic Resonance Imaging Principles, Methods, and Techniques

Clear delineation of optic radiation and very small vessels using phase difference enhanced imaging (PADRE)

Magnetic Resonance Imaging

GE Healthcare. Discovery MR T. Simply powerful. Powerfully simple.

Further Customization of Dot Engines: AutoCoverage

Slice profile optimization in arterial spin labeling using presaturation and optimized RF pulses

Siemens AG, Healthcare Sector. syngo MR D Operator Manual - Breast 0.0.

Image quality evaluation of turbo-spin echo diffusion weighted image (TSE-DWI) : A phantom study

SIGNA Explorer Lift revives our MR

MRI Anatomy and Positioning Series Module 12: Fat Suppression Techniques

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

Improvement of the Image Quality of Black-blood Magnetic Resonance Imaging with the Subtraction Double Inversion Recovery Technique

Alae Tracker: Tracking of the Nasal Walls in MR-Imaging

MR Advance Techniques. Flow Phenomena. Class II

Field Simulation Software to Improve Magnetic Resonance Imaging

Human Subjects in fmri Research

2015 Spin echoes and projection imaging

HETERONUCLEAR IMAGING. Topics to be Discussed:

Saturated Double-Angle Method for Rapid B 1 Mapping

MRI AT HIGH MAGNETIC FIELDS. Kâmil Uğurbil. University of Minnesota

NIH Public Access Author Manuscript Magn Reson Med. Author manuscript; available in PMC 2014 May 16.

Pulse Sequence for Multislice T 1 -Weighted MRI

The ACR magnetic resonance accreditation phantom (ACR MRAP) has been designed to examine a broad range of instrument parameters.

TITLE: Prostate Cancer Detection Using High-Spatial Resolution MRI at 7.0 Tesla: Correlation with Histopathologic Findings at Radical Prostatectomy

Magnetic Resonance in Medicine. Root-flipped multiband radiofrequency pulse design. For Peer Review. Journal: Magnetic Resonance in Medicine

Optimizing the Magnetization-Prepared Rapid Gradient-Echo (MP-RAGE) Sequence

The development of the RF-pulse for the low level SAR used by the MRI.

Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil

Spiral MRI on a 9.4T Vertical-bore Superconducting Magnet Using Unshielded and Self-shielded Gradient Coils

EE225E/BIOE265 Spring 2011 Principles of MRI. Assignment 6 Solutions. (y 0 + vt) dt. 2 y 0T + 3 )

Challenges of Field Inhomogeneities and a Method for Compensation. Angela Lynn Styczynski Snyder. Michael Garwood, Ph.D., Adviser

functional MRI: A primer

Numerical Evaluation of an 8-element Phased Array Torso Coil for Magnetic Resonance Imaging

6.S02 MRI Lab Acquire MR signals. 2.1 Free Induction decay (FID)

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

Magnetic Resonance Research Facility (MRRF) Resources

磁振影像學 MRI 磁振假影與磁振安全 磁振假影. 本週課程內容 Hardware-related Artifacts 盧家鋒助理教授 磁振假影 磁振安全

EE469B: Assignment 1 Solutions

Multi-channel SQUID-based Ultra-Low Field Magnetic Resonance Imaging in Unshielded Environment

SNR and functional sensitivity of BOLD and perfusion-based fmri using arterial spin labeling with spiral SENSE at 3 T

MARP. MR Accreditation Program Quality Control Beyond Just the Scans and Measurements July 2005

Functional MRI with variable echo time acquisition

EE225E/BIOE265 Spring 2012 Principles of MRI. Assignment 7. Due March 16, 2012

Inherent Insensitivity to RF Inhomogeneity in FLASH Imaging

Jordan Journal of Physics

Lab 8 6.S02 Spring 2013 MRI Projection Imaging

Transcription:

Application Guide & Release Notes Inner-volume-imaging (IVI) EPI C2P Release 002a 1 September 2015 TMII Translational and Molecular Imaging Institute

Conditions of Use This package is provided to support collaborative research projects between the Icahn School of Medicine at Mount Sinai (ISMMS) and University of Minnesota and users of Siemens MRI equipment, in accordance with a current C2P agreement. Authors Junqian Xu, Ph.D. Translational and Molecular Imaging Institute Icahn School of Medicine at Mount Sinai Edward J. Auerbach, Ph.D. Center for Magnetic Resonance Research University of Minnesota 1

Table of Contents Overview... 3 Sequence Description... 4 Hardware and Software Requirements... 5 Installation Procedure... 6 Usage... 7 Important Issues (not bugs)... 12 Known Bugs... 13 Version Changes... 14 Acknowledgment... 15 2

Overview Inner-volume-imaging (IVI) uses orthogonal excitation and refocusing RF pulses to selectively refocus the magnetization from a limited field of view (reduced FOV). In single shot spin echo EPI diffusion imaging, it has the advantage of reducing the EPI readout, hence reducing susceptibility related distortions, when imaging small anatomical structures, such as optic nerve, spinal cord, or prostate. To improve the signal-to-noise (SNR) efficiency, a pair of refocusing/inversion pulses can be applied in the phase-encoding direction in a driven equilibrium fashion. Experimental Combining multiband RF excitation with IVI has not been fully tested. More detailed information about the multiband pulse sequence and image reconstruction implementation can be found at the CMRR multiband C2P download page: www.cmrr.umn.edu/multiband 3

Sequence Description The pulse sequences in this package are based on the product ep2d_diff sequences from Siemens. More detailed information about the IVI EPI diffusion pulse sequence implementation can be found in the following references: 1. Jeong EK, Kim SE, Guo JY, Kholmovski EG, Parker DL. High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rfov-dwepi) Magn. Reson. Med., 54, 1575 1579, 2005 [PubMed] 2. Xu J, Shimony JS, Klawiter EC, Snyder AZ, Trinkaus K, Naismith RT, Benzinger TLS, Cross AH, Song SK. Improved in vivo diffusion tensor imaging of human cervical spinal cord. NeuroImage, 67, 64-76, 2013 [PubMed] The accompanying spinal cord DTI post-processing scripts can be downloaded from: http://sourceforge.net/projects/spinedti More detailed information about multiband pulse sequence can be found at the CMRR multiband C2P download page. 4

Hardware and Software Requirements Versions of the inner-volume-imaging EPI sequences will be available for three Siemens software versions, supporting several system types. It may be possible to use the sequences with other scanners not listed with below (e.g. 1.5T systems), but compatibility has not been tested. VB17A: MAGNETOM Trio (TQ-engine), MAGNETOM Verio 3T (VQengine), and MAGNETOM 7T. (Released) VD13A-SP4: MAGNETOM Skyra 3T (Skyra-XQ). (To be released) VD13D: MAGNETOM Prisma 3T. (To be released) 5

Installation Procedure Important: please install the CMRR Multiband C2P (development release) first! 1. Please skip this step unless errors are encountered in step 8: Restart the system (reboot host and MRIR, or restart image calculation and the syngo Exam task card). This is necessary to unload possibly locked shared objects. 2. Login as Advanced User. 3. Extract the.zip file to a temporary directory 4. Open a command window from Windows start menu -> run -> cmd. 5. Open ideacmdtool from the command window. 6. Choose 2 PAS unload, then type q to quit 7. Run the installer.bat file 8. If the installer reports any error, please restart the system and try again. 9. If a sample protocol is available for your system, it will appear at the end of the USER tree in the Exam Explorer. If a sample protocol is not available, create a default protocol in Exam Explorer by selecting Insert Sequence, USER, then tmii_ep2d_diff_ivi for the desired sequence variant. 6

Usage The sequence is based on the Siemens product ep2d_diff sequence; most of the protocol parameters are the same. The most important changes appear on the following measurement cards: Routine Card FoV phase: This parameter determines the IVI slab thickness in the phase encoding direction. The Phase oversampling parameter increases the slab thickness by the input percentage. Slice group: multiple slice groups are allowed for multi-slicemulti-angle (MSMA). (see Important Issues) Multi-band accel. factor: Ref. CMRR multiband C2P release note 7

Contrast/Common Card Magn. preparation: Slice-sel. IR and Non-sel. IR can be selective with monopolar diffusion scheme to provide double inversion for magnetization outside of the excited slice for efficient multi-slice imaging. The order of the IR and fatsat module is switched from the Siemens default to place IR after fatsat to minimize delays between the two refocusing/inversion pulses. Grad rev. fat suppr.: If enabled, the polarity of the slice select gradients will be reversed between the pair of refocusing/inversion pulses in the phase-encoding direction. This can provide effective fat suppression at no cost in time or SAR. However, it can also result in signal losses in areas of B0 inhomogeneity. 8

Physio/Signal1 Card Minimum TR is recommended to fit the protocol into the acquisition window. However, the actual TR = # slices * cardiac cycle * Trigger pulse. Acquisition window is typically chosen to be smaller than the average cardiac cycle. Trigger pulse is typically chosen to be one, unless the cardiac cycle is very fast (PP interval < 800 ms), in which case one may choose to skip every other pulse (Trigger pulse = 2) for SNR consideration. 9

Sequence/Part 1 Card Flow comp.: A flow compensated gradient wave form for the excitation slice selective gradient can be selected to reduce motion artifacts in b 0 image (spoilers in slice direction for refocusing pulse are also removed) and diffusion weighted images without b-vector in slice direction. Multi-slice mode: when physiological triggering is on, single-shot provides slice-by-slice triggering, while interleaved only triggers on the first slice. 10

Sequence/Special Card (Ref. CMRR multiband C2P release note) To enable experimental options, please create a text file C:\MedCom\MriCustomer\seq\MBAdvancedSettings.ini with the following contents: [MultiBand] RFPulseShape = 1 11

Important Issues (not bugs) This release will expire on 1 December 2014! Multi-slice-multi-angle (MSMA) is not compatible with Siemens DTI post-processing and mosaic functor. Disable Average ADC maps, Individual ADC maps, FA maps, Mosaic, and Tensor when MSMA is used. Only diffusion modes MDDW and Free are compatible with multi- band. The other modes have been disabled (diffusion vector in the PRS coordinates can be specified in the external DiffusionVectors file). The MDDW license is therefore required to insert the MB diffusion sequence. 12

Known Bugs When slice-selective IR or non-selective IR is selected with fat saturation (fatsat), the order of the IR and fatsat module is switched from the Siemens default to place IR after fatsat. However the displayed TI does not reflect this change. 13

Version Changes Release 002a, 1 September 2015 (jgx: vb17a/73410c6 multiband C2P R012b) Same as R002 with extended expiration date Release 002, 3 June 2014 (jgx: vb17a/d2af6b9 multiband C2P R011) UI: RF pulse shape and refocus pulse duration Release 001, 28 March 2014 (jgx: vb17a/37ca1d6 multiband C2P R010b) Initial public release 14

Acknowledgment Niels Oesingmann, Ph.D. Siemens collaboration manager Icahn School of Medicine at Mount Sinai product source code, MRA addendum, C2P management Agus Priatna, Ph.D. Siemens collaboration manager Washington University School of Medicine product source code, MRA addendum Funding Department of Defense (DOD):PC050667 National Multiple Sclerosis Society (NMSS): FG1782A1 initial IVI implementation NIH Human Connectome Project: U54MH091657-01 NIH NCRR: P41 RR008079 NIH NIBIB: P41 EB015894 multiband development Radiological Society of North America (RSNA): RSCH1328 TMII and Department of Radiology: Icahn School of Medicine Capital Campaign integration of multiband with IVI/rFOV techniques 15