System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Similar documents
SX (400V) System configuration

SX (400 V) System configuration

SX (690 V) System configuration

Emotron FDU 2.0 Variable Speed Drive

Emotron FDU 2.0 Variable Speed Drive

ACH550 HVAC Drive Submittal

Dynamic drives for low power AC motors

S11 Adjustable Speed Drive Engineering Specification

VFB40 Frequency inverters 004 to 016 (B1) VFX40 Frequency inverters 018 to 037 (S2)

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

VF-nC1 Adjustable Speed Drive Engineering Specification

vacon nxs robust drive for heavy use

Inverter Drive /Vector Drive Motors & Controls

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Fan and Pump AC Inverter

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

TECHNICAL CATALOGUE EMOTRON FLOWDRIVE EMOTRON FLOWDRIVE KW, V IP20, IP21 AND IP54

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

E3 Adjustable Speed Drive Engineering Specification

General Purpose Drives

Integrated servo motor

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Manual Overview...1 2

ADJUSTABLE SPEED DRIVES. AS1 Drive

WJ200 series Pursuing the Ideal Compact Inverter

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Emotron VFX 2.0 Variable Speed Drive

PowerFlex 400 Submittal

High power Direct Torque Control Inverters Model: SX-F 400 V Class Three-Phase Input 90 kw to 800 kw 690 V Class Three-Phase Input 90 kw to 1000 kw

NX series Constant and variable torque Variable Speed Drives for induction motors

FUJI Inverter. Standard Specifications

EN 50178, IEC

VEMoDRIVE Frequency Converter VSI2.0

ADJUSTABLE SPEED DRIVES FS1

The new Yaskawa Varispeed G7 Inverter

SX-F INSTRUCTION MANUAL

General Specifications FECA-TE /2010. Phone: Fax: Web:

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Altivar 28 drive Altivar 28 enclosed drive

Frequency Inverters. VF-nC3 VF-S11 VF-FS1 VF-PS1 VF-AS1

Phoenix DX Clean Power (18 Pulse) AC Drive

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1.0HP 350HP V Single & 3 Phase Input

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

FLOWDRIVE FDU. Valid for the following inverter Models: FDU to FDU40-1k1 FDU to FDU50-1k1 FDU to FDU69-1k1 Software version: 3.

AF91 Adjustable Frequency Drives Series B

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

TECO V33 Variable Speed Drive

SJ series P1 High performance inverter with innovative ease-of-use and excellent driving performance

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

Design Characteristics. FlexDrive II. Series

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Design Specifications Operator Keypad Environmental and Operating Conditions

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

This Chapter contains:

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ABB and Baldor Drives. CA769 Effective Date: June, 2015

vacon nx all in one application manual ac drives Phone: Fax: Web: -

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

MV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

Product description. At a glance. Customer benefits

TOSVERT TM VF-nC3 Parameter List

GS1 Parameter Summary Detailed Parameter Listings...4 9

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Analog Servo Drive 25A20DD

EFC 3600 Frequency converter for higher energy efficiency and improved process control

Emotron VFX size C Variable Speed Drive

02/11/2015

Specifications of ASDA A2-E_220V Series

High on efficiency big on reliability AC Drive for Fans & Pumps

Power Regenerative Converter, THYFREC CV240S

TDE MACNO Spa. AC&DC Drives, Servos and Drive System. AFE converters for Renewable Energies Regenerative (active) power supply (Active Front End)

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

NX Series Inverters. HVAC Pocket Programming Guide

Transcription:

~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards Load curve control HCB technology (Half controlling Bridge) Logic programmability Pre-maintenance alarms Options flexibitity (I/O s, Fieldbus, PTC/PT100, Multiple Pump control, Encoder, Crane control) Communications options (Modbus, Dnet, Profibus) 24 VDC control board supply Liquid cooling drive version 12-pulse rectifier option. Flexible cable connections & User Friendly wiring connection CE, UL, RoHS, DNV Frequency inverters Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw System configuration Power supply Panel kit I/O option board SX-D Communication option board Feedback speed option card PTC/PT100 option card Output coils Brake resistor Motor Overshoot clamp Ground SX 167

Specifications Type designation S X-D6160-EF-OPTIONS sx series Protection Class: D: IP54 Voltage: 4: 400 / 480 VAC 6: 690 VAC Rated Power: 090: 90 kw ~ 1k0: 1000 kw Check below table Control type: V: V/Hz F: Direct Torque Control Market: E: Europe Options available Options Letter (? means no character) Options Letter (? means no character) Control panel? = Standard control panel (Std.PPU) A = Blank control panel (Blank PPU) Option board position 2? = No option I = Encoder J = PTC/PT100 K = Extended I/O Built-in EMC filter? = Standard EMC inside (Category C3) B = IT-Net (filter disconnected from ground) Built-in brake chopper Standby power supply Safe stop Coated boards Option board position 1 400 V class Motor kw 1 Output characteristics Power supply 600 V class? = No brake chopper or DC-connection included C = Brake chopper & DC-connection included D = Only DC-connection included? = Not included E = Standby power supply included? = Not included F = Safe stop included? = No coating G = Coated boards? = No option H = Crane I/O I = Encoder J = PTC/PT100 K = Extended I/O Option board position 3 Option board Fieldbus position 4 Liquid Cooling Standard Cabinet input options Cabinet output options? = No option I = Encoder J = PTC/PT100 K = Extended I/O? = No option L = DeviceNet M = Profibus-DP N = RS232/485 O = EtherNet Modbus TCP? = No Liquid Cooling P = Liquid Cooling? = IEC Q = UL? = No cabinet input options S = Main switch included T = Main contactor included U = Main switch + contactor included? = No cabinet output options included V = dv/dt filter included W = dv/dt filter + Overshoot clamp included X = Sinusfilter included Three-phase: SX-D4@@-EF 090 110 132 160 200 220 250 315 355 400 450 500 630 800 For HD setting 75 90 110 132 160 200 220 250 315 355 400 450 500 630 For ND setting 90 110 132 160 200 220 250 315 355 400 450 500 630 800 Max output current (A) 210 252 300 360 450 516 600 720 780 900 1032 1200 1440 1800 Rated output current (A) at HD 140 168 200 240 300 344 400 480 520 600 688 800 960 1200 Rated output current (A) at ND 175 210 250 300 375 430 500 600 650 750 860 1000 1200 1500 Output voltage 0 to Mains supply voltage Max. output frequency 400 Hz Rated input voltage and frequency 3-phase 230..480 V 50/60 Hz Allowable voltage fluctuation +10%..-15% (-10% at 230V) Allowable frequency fluctuation 45 to 65 Hz 1. Based on a standard 4-pole motor for maximum applicable motor output Motor kw Output characteristics Power supply Three-phase: SX-D6@@-EF 090 110 132 160 200 250 315 355 450 500 600 630 710 800 900 1K0 For HD setting 75 90 110 132 160 200 250 315 315 355 450 500 600 650 710 800 For ND setting 90 110 132 160 200 250 315 355 450 500 600 630 710 800 900 1000 Max output current (A) 108 131 175 210 252 300 360 450 516 600 720 780 900 1032 1080 1200 Rated output current (A) at HD 72 87 117 140 168 200 240 300 344 400 480 520 600 688 720 800 Rated output current (A) at ND 90 109 146 175 210 250 300 375 430 500 600 650 750 860 900 1000 Output voltage Max. output frequency Rated input voltage and frequency 0 to Mains supply voltage 400 Hz 3-phase 500..690V, 50/60 Hz Allowable voltage fluctuation +10%..-15% Allowable frequency fluctuation 45 to 65 Hz 168 Frequency inverters

Specifications Commom specifications Control functions Model number SX- Control methods Output frequency range Frequency tolerance Resolution of frequency set value Resolution of output frequency Frequency set value Starting Torque Torque static accuracy Torque response Speed Control Accuracy Speed Response Torque Limit Accel/Decel Time Specifications V/f control for V type V/f control, Vector control with or without feedback for the F type 0.0..400 Hz Analogue set value: 1% + 1.5 LSB fsd Digital set value: 0.1 Hz Analogue set value: 0.03 Hz / 60 Hz (11 bit + sign) 0.1 Hz -10..+10 V (20 kω), 0..20 ma (250 Ω), frequency setting value (selectable) 150% for Heavy duty, 120% for Normal duty <3% in Vector control with feedback <3% in vector control without feedback if speed between 10 and 100%, <10% at 0 Hz 1 ms for 0-90% speed 5 ms for 90-100% speed (Close and open loop) V/f control 1% Vector control without feedback 0.1% Vector control with feedback 0.01% 0.4% without encoder feedback 0.2% with encoder feedback From Analog input 0.0 to 3600.0 s Braking torque 5-10% (100% with external braking resistor) Frequency inverters Functionality Protection functions Ambient conditions Main Control Functions Motor protection Momentary overcurrent Protection Overload Protection Overvoltage Protection Undervoltage Protection Momentary power loss Ride-Thru Heatsink Overheat Protection Braking Resistance Overheat Protection Stall prevention Power charge indication Ambient Temperature Ambient humidity Storage temperature PID, sleep function, brake control, torque control (Direct torque control model), Pump/Fan control, Logic functions, virtual connections, overvoltage control, undervoltage override, autoreset, two motor support, Lim Switch, External trip, Preset Speeds, MotPot Up Down, Pump Feedback, Timer, Mot PreMag, Jog, Ext Mot Temp, Loc/Rem, AnIn select, Brk Ackn. Motor overheat protection based on output current or PTC by option board Drive stops when ouput current exceeds 200% of peak current Drive stops after 1 min at 150% of rated output current (Heavy Duty Rating) Drive stops after 1 min at 120% of rated output current (Normal Duty Rating) (1min every 10min) Line Overvoltage: 760 VDC during more than 10s for 400 V class; 1120 VDC during more than 10 s for 690 V class Fast Overvoltage: 850 VDC for 400 V class; 1220 for 690 VDC 400 VDC for 400 V class; 500 for 690 V class (Adjustable by input power supply parameter) Low voltage override function Protected by thermister Hardware short circuit protection Current limit function Power LED remains lit while capacitors are charged 0ºC..+40ºC, up to 45ºC with derating 90% RH or less (without condensation) -20ºC..+60ºC (short-term temperature during transportation) Altitude Up to 1000 meters (output derating of 1% per 100 m above 1000 m, max. 2000 m) Vibration / Shock According to IEC 600068-2-6, Sinusodial vibrations: 10<f<57 Hz, 0.075 mm, 57<f<150 Hz, 1g Contamination, according to IEC 60721-3-3 No electrically conductive dust allowed. Cooling air must be clean and free from corrosive materials. Chemical gases, class 3C2. Solid particles, class 3S2 Protection Design IP54 enclosure according to the EN 60529 SX 169

Dimensions Standard dimensions (IP54) SX-4090 SX-4110 to 4132 SX-6090 to 6160 22,50 240 120 Ø9(6x) 284,50 275 10 22.50 300 150 Ø9(x6) 30 344,5 335 400V 925 400V 952,50 400V 922,50 925 952,50 922,50 600V 1065 600V 1092,50 600V 1062,50 10 Ø16(3)x) 30 Ø16(3x) 314 314 SX-4160 to 4250 SX-6200 to 6355 2330 SX-4315 to 4400 SX-6450 to 6500 2330 600 600 1000 600 170 Frequency inverters

SX-4450 to 4500 SX-6600 to 6630 SX-4630 to 4800 SX-6710 to 61K0 2330 2330 Frequency inverters 1200 600 2000 600 LCD operator SX 171

Output coils Type Fig a b c n2 n1 Fix Weight Connection 473169 00 1 190 120 235 170 66 M6 8.4 kg 35 mm 2 473170 00 190 140 260 170 77 M6 10.2 kg 35 mm 2 473171 00 2 210 160 180 175 97 M6 13.4 kg M10 473172 00 230 170 200 175 95 M6 18.4 kg M10 Specifications Model Rated current Inductance Rated voltage Max carrier Max output frequency Max temp 473169 00 90A 0.1 mh 473170 00 146A 0.05 mh 6 khz 200Hz 800V 473171 00 175A 0.05 mh 473172 00 275A 0.032 mh 1.5 khz 100Hz 40ºC 172 Frequency inverters

Installation Standard connections L1 L2 RFIfilter U V Motor L3 W PE Alternative for potentiometer control** Optional DC+ R 1 +10 VDC DC - 2 3 4 5 6 AnIn 1: Reference AnIn 2 AnIn 3 AnIn 4-10 VDC Common AnOut 1 AnOut 2 12 13 14 Frequency inverters 7 Common DigOut 1 20 8 DigIn 1:RunL* DigOut 2 21 9 DigIn 2:RunR* 10 11 15 16 DigIn3 +24 VDC Common DigIn 4 Relay 1 31 32 33 17 18 19 22 DigIn 5 DigIn 6 DigIn 7 DigIn 8:Reset* Relay 2 41 42 43 Relay 3 51 52 Other options Fieldbus option or PC Option board NG_06-F27 SX 173

Main circuit Terminal Name Function (signal level) L1, L2, L3 Main circuit power supply input Used to connect line power to the drive. U, V, W Inverter output Used to connect the motor DC-, DC+, R DC link connections, Brake resistor The brake resistor must be connected terminals DC+ and R (Terminals are only fitted if the Brake Chopper Option is built-in) PE Safety earth Protected earth Grounding Motor earth Control Circuit Type No. Signal name Function Signal level 8 DigIn 1 RunL (reverse) 9 DigIn 2 RunR (forward) Digital input signals 10 DigIn 3 Off 16 DigIn 4 Off 17 DigIn 5 Off 18 DigIn 6 Off 19 DigIn 7 Off 22 DigIn 8 RESET High > 9 VDC Low < 4 VDC Max 30 VDC Impedance 4.7 kω for < 3.3 VDC 3.6 kω for > 3.3 VDC 11 +24 V +24 VDC supply voltage 15 Common Signal ground 1 +10 V +10 VDC supply voltage Max 100mA Analog input signals 2 AnIn 1 Process Ref 3 AnIn 2 Off 4 AnIn 3 Off 5 AnIn 4 Off 6-10 V -10 VDC supply voltage -10 to 10 VDC 0 to 20mA Max 30V/30mA Impedance 20 kω Voltage 250 Ω Current Digital output signals 7 Common Signal ground 20 DigOut 1 Ready 21 DigOut 2 Brake 12 Common Signal ground 31 N/C 1 32 COM 1 33 N/O 1 41 N/C 2 42 COM 2 43 N/O 2 Relay 1 output Trip, active when the VSD is in a TRIP condition. Relay 2 output Run, active when the VSD is started. High > 20VDC @50mA > 23VDC open Low <1 VDC @ 50mA 100 ma max togheter with +24VDC 0.1 to 2A 250 VAC or 42 VDC 51 COM 3 52 N/O 3 Relay 3 output Off Analog output signals 12 Common Signal ground 13 AnOut1 Min speed to max speed 14 AnOut2 0 to max torque 0-10V / 0-20mA Max -15V @ 5mA Impedance: 10 Ω (Voltage) 174 Frequency inverters

~ ~ Ordering information Power supply A Panel kit SX-D B I/O option board C Communication option board G Output coils Motor H D E F Overshoot clamp Feedback speed option card PTC/PT100 option card Brake resistor Frequency inverters Ground SX-D Specifications Model Voltage Heavy Duty Normal Duty Direct torque control V/F 75 kw 140 A 90 kw 175 A SX-D4090-EF SX-D4090-EV 90 kw 168 A 110 kw 210 A SX-D4110-EF SX-D4110-EV 110 kw 200 A 132 kw 250 A SX-D4132-EF SX-D4132-EV 132 kw 240 A 160 kw 300 A SX-D4160-EF SX-D4160-EV 160 kw 300 A 200 kw 375 A SX-D4200-EF SX-D4200-EV 200 kw 344 A 220 kw 430 A SX-D4220-EF SX-D4220-EV 400 V 220 kw 400 A 250 kw 500 A SX-D4250-EF SX-D4250-EV 250 kw 480 A 315 kw 600 A SX-D4315-EF SX-D4315-EV 315 kw 520 A 355 kw 650 A SX-D4355-EF SX-D4355-EV 355 kw 600 A 400 kw 750 A SX-D4400-EF SX-D4400-EV 400 kw 688 A 450 kw 680 A SX-D4450-EF SX-D4450-EV 450 kw 800 A 500 kw 1000 A SX-D4500-EF SX-D4500-EV 500 kw 960 A 630 kw 1200 A SX-D4630-EF SX-D4630-EV 630 kw 1200 A 800 kw 1500 A SX-D4800-EF SX-D4800-EV 690 V 75 kw 72 A 90 kw 90 A SX-D6090-EF SX-D6090-EV 90 kw 87 A 110 kw 109 A SX-D6110-EF SX-D6110-EV 110 kw 117 A 132 kw 146 A SX-D6132-EF SX-D6132-EV 132 kw 140 A 160 kw 175 A SX-D6160-EF SX-D6160-EV 160 kw 168 A 200 kw 210 A SX-D6200-EF SX-D6200-EV 200 kw 200 A 250 kw 250 A SX-D6250-EF SX-D6250-EV 250 kw 240 A 315 kw 300 A SX-D6315-EF SX-D6315-EV 315 kw 300 A 355 kw 375 A SX-D6355-EF SX-D6355-EV 315 kw 344 A 450 kw 430 A SX-D6450-EF SX-D6450-EV 355 kw 400 A 500 kw 500 A SX-D6500-EF SX-D6500-EV 450 kw 480 A 600 kw 600 A SX-D6600-EF SX-D6600-EV 500 kw 520 A 630 kw 650 A SX-D6630-EF SX-D6630-EV 600 kw 600 A 710 kw 750 A SX-D6710-EF SX-D6710-EV 650 kw 688 A 800 kw 860 A SX-D6800-EF SX-D6800-EV 710 kw 720 A 900 kw 900 A SX-D6900-EF SX-D6900-EV 800 kw 800 A 1000 kw 1000 A SX-D61K0-EF SX-D61K0-EV SX 175

A Panel Kit Model Description Function 01-3957-00 Panel kit Panel kit complete including panel 01-3957-01 Blank panel kit Panel kit complete including blank panel B I/O option board Model Description Function 01-3876-01 Additional I/O option Provides 3 extra relay outputs and 3 additional digital inputs 01-3876-07 Crane option Dedicated option board for crane application, including additional I/O and functions C Communication option board Type Model Description Function 01-3876-04 RS232/485 MODBUS RTU serial communication by RS232 or RS485 interface with galvanic isolation 01-3876-05 PROFIBUS-DP option card Used for operating the inverter through PROFIBUS-DP communication with the host controller. 01-3876-06 DeviceNet option card Used for operating the inverter through DeviceNet communication with the host controller. Communication option board 01-3876-09 Modbus/TCP, Ethernet Used for operating the inverter through Modbus/TCP communication with the host controller. D Encoder feedback option card Model Description Function 01-3876-03 Encoder option Used for connection of the actual motor speed via encoder. Up to 100kHz with TTL and HTL incremental encoders with 5/24 V power supply E PTC/PT100 option card Model Description Function 01-3876-08 Thermal protection Allows to conect a motor thermistor to the inverter F Braking chooper and braking resistor All inverter sizes could be fitted with an optional built-in brake chopper from factory but is not possible to install it later. The choice of the resistor depends on the application switch-on duration and duty-cycle Following tables describes the activation level of the built-in braking chopper and the minimum resistor that could be used depending on the input voltage. 400 V 600 V Type R for different input voltage (Ω) R for different input votlage (Ω) Type 220-240 VAC 380-415 VAC 440-480 VAC 500-525 VAC 550-600 VAC 660-690 VAC SX-D4090-EF 3.8 3.8 4.4 SX-D6090-EF 4.9 5.7 6.5 SX-D4110-EF 2.7 2.7 3.1 SX-D6110-EF 4.9 5.7 6.5 SX-D4132-EF 2.7 2.7 3.1 SX-D6132-EF 4.9 5.7 6.5 SX-D4160-EF 2 x 3.8 2 x 3.8 2 x 4.4 SX-D6160-EF 4.9 5.7 6.5 SX-D4200-EF 2 x 3.8 2 x 3.8 2 x 4.4 SX-D6200-EF 2 x 4.9 2 x 5.7 2 x 6.5 SX-D4220-EF 2 x 2.7 2 x 2.7 2 x 3.1 SX-D6250-EF 2 x 4.9 2 x 5.7 2 x 6.5 SX-D4250-EF 2 x 2.7 2 x 2.7 2 x 3.1 SX-D6315-EF 2 x 4.9 2 x 5.7 2 x 6.5 SX-D4315-EF 3 x 2.7 3 x 2.7 3 x 3.1 SX-D6355-EF 2 x 4.9 2 x 5.7 2 x 6.5 SX-D4355-EF 3 x 2.7 3 x 2.7 3 x 3.1 SX-D6450-EF 3 x 4.9 3 x 5.7 3 x 5.7 SX-D4400-EF 3 x 2.7 3 x 2.7 3 x 3.1 SX-D6500-EF 3 x 4.9 3 x 5.7 3 x 5.7 SX-D4450-EF 4 x 2.7 4 x 2.7 4 x 3.1 SX-D6600-EF 4 x 4.9 4 x 5.7 4 x 5.7 SX-D4500-EF 4 x 2.7 4 x 2.7 4 x 3.1 SX-D6630-EF 4 x 4.9 4 x 5.7 4 x 5.7 SX-D4630-EF 6 x 2.7 6 x 2.7 6 x 3.1 SX-D6710-EF 6 x 4.9 6 x 5.7 6 x 5.7 SX-D4800-EF 6 x 2.7 6 x 2.7 6 x 3.1 SX-D6800-EF 6 x 4.9 6 x 5.7 6 x 5.7 - SX-D6900-EF 6 x 4.9 6 x 5.7 6 x 5.7 SX-D61K0-EF 6 x 4.9 6 x 5.7 6 x 5.7 Supply voltage (VAC)l Built-in brake chopper trigger level (VDC) 220-240 380 380-415 660 440-480 780 500-525 860 550-600 1000 660-690 1150 176 Frequency inverters

G Output coils Output coils above SX-D4132-EF for the 400V and SX-D6160-EF should be order from factory as they should be installed inside of the cabinet Voltage Inverter model Model Rated current Inductance Rated Voltage Max carrier Max output frequency SX-D4090-EF 473171 00 175A 0.05 mh 6 KHz 200 Hz 400V SX-D4110-EF SX-D4132-EF 473172 00 275A 0.032 mh 1.5 khz 100 Hz SX-D6090-EF 473169 00 90A 0.1 mh 800V 6 khz 200 Hz 690V SX-D6110-EF SX-D6132-EF 473170 00 146A 0.05 mh 6 khz 200 Hz SX-D6160-EF 473171 00 175A 0.05 mh 6 khz 200 Hz Max temp 40ºC H Overshoot clamp Only two types of overshoot clamps could be order for after mounting Model Inverter Function 52163 52220 SX-4090 to SX-4132 SX-6090 to SX-6160 SX-4160 to SX-4800 SX-6200 to SX-61K0 Together with the output coils, the overshoot clamp restricts the voltage and the dv/dt on the motor winding. Inverters must be ordered including the option DC+/DC- connectors. Together with the output coils, the overshoot clamp restricts the voltage and the dv/dt on the motor winding. Doesn t require the DC+/DC- option. Frequency inverters SX 177

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I125E-EN-01B In the interest of product improvement, specifications are subject to change without notice. 178 Frequency inverters