Performance Of Distributed Power Flow Controller (DPFC) Under Fault Condition

Similar documents
MITIGATION OF VOLTAGE SAG AND SWELL FOR POWER QUALITY IMPROVEMENT USING DISTRIBUTED POWER FLOW CONTROLLER

Designing Of Distributed Power-Flow Controller

Enhancement of Power Quality in Multi Feeders by using MC-DPFC

Modeling and Analysis of DPFC to Improve Power Quality

Mitigation of Voltage Sag and Swell by Ant Colony Optimization Technique using DPFC

Designing and Control of Converters used in DPFC for Mitigation of Voltage Sag and Swell In Transmission Line

Comparison of Dynamic Stability Response of A SMIB with PI and Fuzzy Controlled DPFC

Improvement of System Reliability & Power Transfer Capability using Distributed Power- Flow Controller (DPFC)

Power Flow Control by Using DPFC

Power Quality Enhancement and Mitigation of Voltage Sag using DPFC

Power Quality Improvement And Mitigation Of Voltage Sag And Current Swell Using Distributed Power Flow Controller

Mitigation of Voltage Sag and Swell Using Distributed Power Flow Controller

A COMPARATIVE STUDY ON UPFC AND DPFC TOWARDS LOW HARMONIC DISTORTION

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

International Journal of Advance Engineering and Research Development

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

Power Quality enhancement of a distribution line with DSTATCOM

Power Quality Improvement in Distribution System Using D-STATCOM

SIMULATION OF DISTRIBUTED POWER FLOW CONTROLLER FACTS DEVICE IN VOLTAGE SAG AND SWELL MITIGATION

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Application of Fuzzy Logic Controller in UPFC to Mitigate THD in Power System

Compensation of Unbalanced Three Phase Currents in a Transmission line using Distributed Power Flow Controller

A Fuzzy based MC-DPFC for Enhancement of Power Quality in Transmission Line

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Mitigation of Flicker Sources & Power Quality Improvement by Using Cascaded Multi-Level Converter Based DSTATCOM

Performance Evaluation of Mho and Quadrilateral Characteristic Relays on UPFC Incorporated Transmission Line

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

Modified Approach for Harmonic Reduction in Transmission System Using 48-pulse UPFC Employing Series Zig-Zag Primary and Y-Y Secondary Transformer

Investigation of D-Statcom Operation in Electric Distribution System

Enhancement of Power Quality in Distribution System Using D-Statcom for Different Faults

A RELATIVE STUDY ON UPFC AND DPFC ON THE BASIS OF TOTAL HARMONICS DISTORTION

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Comparison of Simulation Results of D-Facts & UPFC Used for Power Quality Improvement

Manjeet Baniwal 1, U.Venkata Reddy 2, Gaurav Kumar Jha 3

DESIGN A D STATCOM FOR VOLTAGE HARMONIC SUPPRESSION IN DISTRIBUTION SYSTEM

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

A VOLTAGE SAG/SWELL ALONG WITH LOAD REACTIVE POWER COMPENSATION BY USING SERIES INVERTER of UPQC-S

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

Mitigation of Voltage Sag/Swell Using UPQC

Modeling and Simulation of STATCOM

Power Quality and the Need for Compensation

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Investigation of negative sequence injection capability in H-bridge Multilevel STATCOM

Transient Stability Improvement of Multi Machine Power Systems using Matrix Converter Based UPFC with ANN

Comparison and Simulation of Open Loop System and Closed Loop System Based UPFC used for Power Quality Improvement

Performance of DVR under various Fault conditions in Electrical Distribution System

Improvement of Power Quality Using a Hybrid Interline UPQC

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

A Novel Approach to Simultaneous Voltage Sag/Swell and Load Reactive Power Compensations Using UPQC

FACTS devices in Distributed Generation

POWER FLOW CONTROL WITH UPFC IN POWER TRANSMISSION SYSTEM

A Specialized UPQC for Combined Simultaneous Voltage Sag/ Swell Problems in Distribution System

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

ISSN Vol.07,Issue.21, December-2015, Pages:

Modeling and Simulation of SRF and P-Q based Control DSTATCOM

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Simulation of Multi Converter Unified Power Quality Conditioner for Two Feeder Distribution System

Comparison of Simulation and Experimental Results of UPFC used for Power Quality Improvement

Enhancement of Power Quality in Distribution System Using D-Statcom

Development and Simulation of Dynamic Voltage Restorer for Voltage SAG Mitigation using Matrix Converter

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

Control of grid connected inverter system for sinusoidal current injection with improved performance

Interline Power Flow Controller: Review Paper

SIMULATION OF DSTATCOM FOR POWER FACTOR IMPROVEMENT

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Comparison of FACTS Devices for Power System Stability Enhancement

Improving the Electric Power Quality by UPFC Systems in Electrical Networks

Harmonics Elimination Using Shunt Active Filter

Multiconverter Unified Power-Quality Conditioning System: MC-UPQC T.Charan Singh, L.Kishore, T.Sripal Reddy

Mitigation of Voltage Sag and Swell using Distribution Static Synchronous Compensator (DSTATCOM)

Volume I Issue VI 2012 September-2012 ISSN

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Voltage Flicker Compensation using STATCOM to Improve Power Quality

Harmonics Reduction and Power Quality Improvement by using Multilevel DPFC

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Power Quality Improvement using Hysteresis Voltage Control of DVR

Level Shifted Pulse Width Modulation in Three Phase Multilevel Inverter for Power Quality Improvement

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

SIMULATION OF D-STATCOM AND DVR IN POWER SYSTEMS

Analysis of Power System Oscillation Damping & Voltage Stability Improvement Using SSSC in A Multimachine System

Multilevel Inverter Based Statcom For Power System Load Balancing System

Improvement of Voltage Profile using D- STATCOM Simulation under sag and swell condition

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Transcription:

RESEARCH ARTICLE OPEN CESS Performance Of Distributed Power Flow Controller (DPFC) Under Fault Condition Santosh Kumar Gupta M.Tech. Student, Department of Electrical Engineering National Institute of Technology Kurukshetra, Haryana-136119, India Santoshgupta1990@gmail.com Shelly Vadhera Associate Professor, Department of Electrical Engineering National Institute of Technology Kurukshetra, Haryana-136119, India Shelly_vadhera@rediffmail.com Abstract : In this paper power quality issues are improved using Distributed Power Flow Controller (DPFC). The DPFC is basically derived from the unified power-flow ler (UPFC) and DPFC has the same capability as the UPFC. The UPFC can be replaced by the DPFC with elimination of common dc link. In the DPFC active power takes place between the shunt and series converters through the transmission lines at the 3 rd harmonic frequency. The DPFC employs the distributed FTS (D-FTS) idea, which is to use multiple small-size single phase converters instead of the one large-size three-phase as in UPFC. So the cost of the DPFC system is lower than the UPFC. The dynamic performance of the DPFC has been studied in this paper by considering symmetrical three phase fault near to the load end. Finally MATLAB/SIMULINK results indicate improved performance in voltage sag mitigation, notable reduction in harmonic of load voltage and enhance power flow. Keywords- DPFC, sag mitigation, load voltage harmonic reduction, power flow. I. Introduction The emphasise of high quality electrical power is owing to increase in electricity requirements and also due to increase in non linear loads increase in electricity requirement and in number of non-linear loads in power grids [1]. Flexible alternating current transmission system (FTS) and custom power devices, improves power quality improvement progressively [2]. The effective FTS device is one which can simultaneously all system parameters: the bus voltage, the transmission angle and the line impedance. The unified power-flow ler (UPFC) is the most powerful FTS device, which can simultaneously all the above system parameters [3]. The UPFC is the combination of a static synchronous compensator (STATCOM) and a static synchronous series compensator (SSSC), both are linked via a common dc link, to permit bidirectional flow of active power between output terminals of the SSSC and the STATCOM as shown in Fig. 1. The UPFC converters can independently generate or absorb reactive power at its own ac terminal. The two converters are operated from a dc link provided by a dc storage capacitor. But in practice the UPFC is not widely applied, because firstly the components of the UPFC handle the currents and voltages of high rating; so, the total cost of the system becomes very high and secondly due to the common dc-link which is an interconnection between series and shunt s therefore on any failure that happens at one converter will influence the whole system. Fig. 1 Block representation of a UPFC. The UPFC can be considered as a DPFC with an elimination of common dc link between series and shunt as shown in Fig. 2. And the active power exchange between the shunt and the series converter is now through the transmission line at the 3 rd harmonic frequency [4]. 76 P a g e

UPFC Elimination of common dc link Distributed series s DPFC (1) P V i I i cos i 1 Fig. 2 Conversion from UPFC to DPFC. The DPFC has two major advantages over the UPFC: 1) low cost because of the low voltage isolation and the low component rating of the series converter and 2) high reliability because of the redundancy of the distributed series converters. The structure of the DPFC is derived from the UPFC structure that which includes one shunt converter and number of small independent series converters, as shown in Fig. 3. In this paper a symmetrical fault is considered near the load end. By taking appropriate ling parameters of DPFC, DPFC mitigates the load voltage sag as well as reduces the load voltage harmonics in seconds. Further the dynamic performance of DPFC is studied and results indicate improvement power quality and enhanced power flow. Transmission line Shunt ---- Series s Fig. 3 Simplified DPFC structure. II. Operating Principle Of Dpfc There are two approaches that applied to the UPFC for modelling of DPFC A. Elimination of Link In case of DPFC, the transmission line is used as a connection between the dc terminal of shunt converter and the ac terminal of series converters, instead of direct connection using dc-link for power exchange between converters. The method of power exchange in DPFC is based on power theory of nonsinusoidal components [4]. Based on Fourier series, a non-sinusoidal voltage or current can be presented as the sum of sinusoidal components at different frequencies. The product of voltage and current components provides the active power, since the integral of some terms with different frequencies are zero. Mathematically the active power equation is as follow: High pass From equation (1) the active power at different frequencies are independent from each other and the voltage or current at one frequency has no influence on the active power at other frequencies. After applying the above concept to the DPFC, the shunt converter can take active power from the grid at the fundamental frequency and inject the power back to grid at a harmonic frequency as shown in Fig. 4. The transmission line carries dual power one at fundamental frequency and other at 3 rd harmonic frequency, using Superposition theorem both power can be attained. The high-pass in the DPFC structure blocks the fundamental frequency components and allows the harmonic components to pass in ground, thereby providing a return path for the harmonic components. The series and shunt converters, the ground, and the high-pass form the closed loop for the harmonic current. Due to the unique characters of 3 rd harmonic frequency components, it is selected to exchange the active power between series and shunt s in the DPFC. The reasons to select 3 rd harmonic for exchange of active power between shunt and series s are as following: Higher transmission frequencies will cause high impedance and lead to an increase of voltage level of converters. The third harmonic in each phase is identical in a three-phase system. The third harmonic is same as the zero-sequence. The zero sequence current can be naturally blocked by Y Δ transformers there is no any requirement of costly to block of harmonic current from receiving end. B. Distributed Series Converters Concept For a lower cost and higher reliability, the distributed FTS was invented [5]. Distributed FTS device (D-FTS) is the concept to use multiple low-power converters attached to the transmission line by single turn transformers [6]. The converters are hanging on the line so that no costly high voltage isolation is required. The distributed series s take the active power at 3 rd harmonic frequency from transmission line and inject it back into the line at fundamental frequency as per disturbances. 77 P a g e

Shunt Active power at fundamental frequency Active power at hormonic frequency - - - - Series s High pass Fig. 4 Active power exchange between converters of DPFC. C. The DPFC Advantages The DPFC has some advantages over UPFC, as follows: High Control Capability The DPFC alike UPFC, can all parameters of transmission network, such as line impedance, bus voltage magnitude and transmission angle. High Reliability The distributed series converters redundancy increases the DPFC reliability during these converters operation. It means, if one of distributed series converters fails, the other converters can continue to work. Low Cost The single-phase distributed series converters rating are less than one three-phase converter. Furthermore, the series converters do not need any high voltage isolation in transmission line connecting in the DPFC; single-turn transformers can be used to floating the series converters. III. CONTROL Of DPFC The DPFC consists of three types of lers to the converters: A. Central Control The central generates the reference signals for both the shunt and series converters of the DPFC as shown in Fig. 5. Its function depends on the specifics of the DPFC application at the power system level. By using concept of single phase to d-q transformation, according to the system requirements, the central provides corresponding current signal for the shunt converter and voltage reference signals for the series converters [7]. All the reference signals for series and shunt generated by the central concern the fundamental frequency components. Central Transmission line Shunt Ish ref 1 Series Vse ref 1 ---- Series Series High pass Fig. 5 DPFC central block diagram. B. Series Control Every series converter has its own series. The ler is used to maintain the dc capacitor voltage of its own converters, by using 3 rd harmonic frequency components, in order to generate series voltage at the fundamental frequency as need by the central The ler inputs are line current, series voltage reference in the d-q frame, and series capacitor voltages. The 3 rd harmonic frequency is the main loop with the DPFC series converter as Fig. 6. Vector principle is used for the dc voltage [7]. V dc,se From local measurement i V dc,se,ref 3rd pass 3 rd homonicfrequency loop dc ler i 3 0 Single phasepll 1 3 3 Single phase inverse dq From central ler V se,ref,3 V se,ref,1 V se,ref PWM Gen. Fig. 6 DPFC series converter. C. Shunt Control The main objective of the shunt is in order to inject a constant 3 rd harmonic current into the transformer neutral to supply active power for the series converters. At the same time, shunt maintains the dc capacitor voltage of the shunt converter at a constant value by taking active power from the grid at the fundamental frequency and injecting the required reactive current at the fundamental frequency into the grid [8]. The fundamental frequency components has two cascaded lers to generate 3 rd harmonic current. The current is the inner loop, which modulates the shunt current at the fundamental frequency. And dc ler loop is used to maintain constant dc capacitor voltage. To 78 P a g e

3 rd frequency loop Vsh,3,d From central ler From Vs measurement Ish,3,ref Current PLL Vsh,3,q 1 3 3 Single phase inverse dq 1 st frequency loop PWM Gen. To Vdc,sh dc From central ler From local measurement Ish,ref,1,d Vsh,1,d Ish,ref,1,q Current Vsh,1,q Vs PLL 1 Inverse dq. Fig. 7 shunt converter IV. Power Quality Improvement The whole model of system under study is shown in Fig. 8 and Fig 9. This system contains two three-phase identical sources at two buses and a nonlinear RLC load is connected at bus 2 and transmission line of 100km length. The DPFC is placed in transmission line, which the shunt converter is connected to the transmission line in parallel through a - Y three-phase transformer, and series converters is distributed among the line. The system parameters are listed in appendix Table I. To simulate the dynamic performance of DPFC, a three-phase fault is considered near the load end. The time duration of the fault is from 0.2 seconds to 0.3 seconds. As shown in Fig. 10, significant voltage sag is observable during the fault, without any compensation (without DPFC). The voltage sag value is about 0.5 per unit. After adding a DPFC, load voltage sag can be mitigated effectively, as shown in Fig. 11..] [ p. u V load Fig. 9 Simulation model of system with the DPFC V. Study Of Simulation Results Voltage sag during fault Time(sec.) Fig. 10 Three-phase load voltage sag waveform during fault. V load [ p. u.] Mitigation of voltage sag Time(sec.) Fig. 8 Simulation model of system without the DPFC. Fig. 11 Mitigation of three-phase load voltage sag with DPFC. The load voltage harmonic analysis without presence of DPFC is illustrated in Fig. 12. It can be seen, after DPFC implementation in system, the even harmonics are eliminated, the odd harmonics are reduced within acceptable limits, and total harmonic distortion (THD) of load voltage is minimized from 79 P a g e

0.12 to 0.01 percentage (Fig. 13), i.e., the standard THD is less than 5 percent in IEEE standard. The shunt voltage is almost constant as shown in Fig. 14 which provides the active power for series s. Fig. 13(b) Fig. 13 (a). Load voltage signal selected for calculating THD (b). Total harmonic distortion in Fig. 13(a), with DPFC. Vdc(volts) Fig. 12(a) Time(sec.) Fig. 14 Voltage across the capacitor of shunt converter. Fig. 12(b) Fig. 12 (a). Load voltage signal selected for calculating THD b). Total harmonic distortion in Fig. 12(a), without DPFC. IV. CONCLUSION This paper presents, the voltage sag mitigation using a new FTS device called distributed power flow ler (DPFC). The structure of DPFC is similar to unified power flow ler (UPFC) and has a same capability to balance the line parameters, i.e., the bus voltage, the transmission angle and the line impedance. However, the DPFC offers some advantages, in comparison with UPFC, such as high capability, high reliability, and low cost. The DPFC is modelled using three loops. The system under study is a two machine infinite-bus system, with and without DPFC. To simulate the dynamic performance of DPFC, a three-phase fault is considered near the load end. It is shown that the DPFC has an acceptable performance in power quality improvement and for power flow. APPENDIX TABLE I. The Simulated System Parameters Fig. 13(a) 80 P a g e

Symbols Descriptions Value Unit f Rated frequency 60 Hz V s Nominal voltage of 230 KV sending end bus s V r Nominal voltage receiving 230 KV end bus r Transmission angle 1 degree between buses s and r Line length 100 km L Line inductance 6 mh Shunt nominal 50 KVA power V dc Shunt capacitor 100 V voltage link capacitor 1800 μf Series coupling 5:25 transformer turns ratio Three phase fault type ABC Fault resistance.111 Ohm Phase Systems to Compensate Harmonic Distortion And Reactive Power, IEEE Power Electronics Specialists Conference, pp. 177-182, Oct. 2004. [8] K. Ramya and C. Christober Asir Rajan, Analysis And Regulation of System Parameters Using DPFC, IEEE International Conference on Advances in Engineering, Science And Management (ICAESM), pp. 505-509, March 2012. References [1] Y. H. Song and A. Johns, Flexible Transmission Systems (FTS) (IEE Power and Energy Series), vol. 30, London, U.K.: Institution of Electrical Engineers, 1999. [2] N. G. Hingorani and L. Gyugyi, Understanding FTS : Concepts And Technology of Flexible Transmission Systems. New York: IEEE Press, 2000. [3] L. Gyugyi, C. D. Schauder, S. L. Williams, T. R. Rietman, D. R. Torgerson, and A. Edris, The Unified Power Flow Controller: A New Approach to Power Transmission Control, IEEE Trans. Power Del., vol. 10, no. 2, pp. 1085 1097, Apr. 1995. [4] Zhihui Yuan, Sjoerd W.H de Haan, Braham Frreira and Dalibor Cevoric A FTS Device: Distributed Power Flow Controller (DPFC), IEEE Trans. on Power Electronics, vol. 25, no. 10, Oct. 2010. [5] Deepak Divan and Harjeet Johal, Distributed FTS A New Concept For Realizing Power Flow Control, IEEE Power Electronics Specialists Conference, pp. 8-14, June 2005. [6] M. D. Deepak, E. B. William, S. S. Robert, K. Bill, W. G. Randal, T. B. Dale, R. I. Michael, and S. G. Ian, A Distributed Static Series Compensator System For Realizing Active Power Flow Control on Existing Power Lines, IEEE Trans. Power Del., vol. 22, pp. 642-649, Jan. 2007. [7] Salaet, J. Alepuz, S. Gilabert and A. Bordonau, DQ Transformation Development For Single 81 P a g e